TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

Similar documents
Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Water Treatment & Purification Chemicals

WATER CHEMISTRY AND POOL WATER BALANCE

Stenner Pump Chlorinator Installation & Start Up Guide

Why Hard Water is a Problem

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

Portable Swimming Pool Reverse Osmosis Systems

BASIC WATER TREATMENT OF STEAM BOILERS

Best Practice in Boiler Water Treatment

PRESSURE WATER HARD MINERALS (LIMEROCK) HARD MINERALS IN SOLUTION HARD MINERALS IN SOLUTION HYDROBLEND CORROSION CONTROL

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Watts Family of water quality improvement products and equipment for whole house water treatment.

Owner s Manual / 5600 Econominder

Evaluation of Alternatives to Domestic Ion Exchange Water Softeners. Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR

Drinking Water Problems: Corrosion

Iron and manganese are two similar elements

Water Treatment Solutions for Residential & Light Commercial Applications

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Home Drinking Water Treatment Systems

Chapter 2.2: Boilers

Testing Water for Gardening and Lawn Irrigation

Purolite Water Softening Resin Guide By: Chubb Michaud

Troubleshooting Your RO

Hydrochemistry. Deacidification. Junianti Roslinda Sihombing. Practical Date : Monday, Report Delivery : Monday,

Feasibility study of crystallization process for water softening in a pellet reactor

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

THE ROWA Anti-limescale Unit MANUAL No chemicals No electricity Maintenance-free Catalytic granulate for limescale stabilising

RECON WATER HEATER INSTALLATION FORM

FERTIGATION. Lawrence J. Schwankl

Carbon Dioxide and Dissolved Oxygen Removal From Makeup Water By Gas Transfer Membranes

Ion Exchange Softening

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Corrosivity of Water Supplies

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

Pure Water. Isn t Hard to Find

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Iron and Manganese BACTERIA AND IRON AND MANGANESE

Removing Heavy Metals from Wastewater

THE USE OF OZONE IN COOLING TOWERS

Restoring bore pump performance

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Culligan Exchange Tank Deionization Service

Where does my water come from? Harrisonburg 2013 Hardness Levels

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Dissolved Mineral Radioactivity in Drinking Water

The National Board of Boiler and Pressure Vessel Inspectors 1055 Crupper Avenue Columbus, Ohio

The role of CO 2 in pool water

Water Info. What is Reverse Osmosis?

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Thermo Siphon Solar Systems

Hardness - Multivalent metal ions which will form precipitates with soaps. e.g. Ca 2+ + (soap) Ca(soap) 2 (s)

Drinking Water Treatment Systems

Water Treatment NOTES. Cornell Cooperative Extension, College of Human Ecology. Iron and Manganese in Household Drinking Water

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Copyright 2006 C-1013

Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Nitrate and Nitrite Removal from Municipal Drinking Water Supplies with Electrodialysis Reversal

Improving your water quality and answering questions about your water

Saving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

Calcium Carbonate Scale Formation, Prediction and Treatment (Case Study Gumry Oilfield-PDOC)

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Christopher Harto Argonne National Laboratory

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

FILLING AND PURGING THE SYSTEM

Hydranautics. RO Water Chemistry

Guide to Common Water Quality Concerns

Wastewater Reuse. Typical treated wastewater is:

Electrodeionization (EDI)

ENE 806, Project Report 3 CHEMICAL PRECIPITATION: WATER SOFTENING. Grégoire Seyrig Wenqian Shan

Factors Affecting Precipitation of Calcium Carbonate

A meaningful, cost-effective solution for polishing reverse osmosis permeate

The Use of Phosphates For Potable Water Treatment

Basics of Reverse Osmosis

ION EXCHANGE RESINS INTRODUCTION

Dear Customer: Most sincerely, Steve Gudovic President BIG PARK WATER COMPANY

Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants

Understanding ph management and plant nutrition Part 2: Water quality

ION EXCHANGE FOR DUMMIES. An introduction

Sulfites for Oxygen Control

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

Maintenance Guide For Above Ground Pools

WASTEWATER TREATMENT OBJECTIVES

Environmental Technology March/April 1998

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

Backflow Bulletin #1

How To Water System

How To Use An Akua Magnetic Lime Scale Preventing Device

01 - Plastic Pipe Cements and Primers

SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE FOR THE TRIANGLE TUBE INDIRECT FIRED WATER HEATER

Technical Presentation IMPORTANT TOPICS

GEOL 414/514 CARBONATE CHEMISTRY

Transcription:

TEMPLATE ASSISTED CRYSTALLIZATION Presented By Ryan Lessing 11/13/2014

Different Forms of Hardness in Water Calcium and Magnesium Bicarbonate- This is what is referred to as temporary hardness. Once it is dissolved into water, heating that water can cause it to precipitate and form scale. It has a relatively low solubility. Calcium and Magnesium Sulphate/Calcium and Magnesium Chloride- This is what is referred to as permanent hardness. Once it is dissolved into water, heating that water usually does not cause it to precipitate and form scale. It has a higher solubility than temporary hardness. This means the water can keep more of it in solution.

TAC s Affect on the Different Hardness Types Temporary Hardness- TAC converts dissolved temporary hardness ions into microscopic nano-crystals. This prevents the hardness in the water from sticking to the plumbing components as scale inside the plumbing system. Permanent Hardness- TAC does not react to form nanocrystals with permanent hardness however that is usually not a concern. This is because permanent hardness is: 1- Not driven to form scale when it is heated 2- Much more soluble than temporary hardness so RO membranes are not affected.

Scale Formation- What Causes Scale to Form Heating the Water Causes Calcium and Magnesium Bicarbonate to Precipitate and Form Scale Water Heater Scale Concentrating the Mineral Content of Water to Create A Higher TDS and Higher Hardness Reverse Osmosis System Scale Allowing Water To Evaporate Will Leave a Mineral Residue Behind Sink Aerators and Shower Heads

Langlier Saturation Index (LSI) The Langlier Saturation Index is a calculation that approximates waters ability to dissolve or deposit Calcium Carbonate scale. It takes into account: ph TDS PPM Alkalinity PPM Calcium Hardness Temperature After the formula is worked through a positive or negative number is calculated. + Number = Scale Forming Water - Number = Non Scale Forming Water 0 Number = Equilibrium

Langlier Saturation Index (LSI) Heat Induced Scale Formation

Langlier Saturation Index (LSI) Heat Induced Scale Formation

Scale Formation- What Causes Scale to Form Heating the water causes calcium and magnesium bicarbonate, the temporary hardness, to precipitate and form scale This is why devices that heat water seem to generate scale and ultimately scale up.

Langlier Saturation Index (LSI) Concentration Induced Scale Formation

Langlier Saturation Index (LSI) Concentration Induced Scale Formation

Scale Formation- What Causes Scale to Form Concentrating minerals in the water to a point where the water can not hold that much of that mineral in solution causes scale formation. This is why RO Membranes that that are fed hard water ultimately scale up. Temporary hardness is the first one to precipitate because it is the least soluble.

Scale Formation- What Causes Scale to Form When Water Evaporates from a surface any minerals that were in the water will be left behind on the surface from which the water evaporated. This is why areas that experience wet/dry conditions over and over again ultimately scale up

TAC- How It Works Crystal growth on the bead surface

TAC- How It Works Seed Crystals release when large enough

TAC- How It Works TAC media begins to attract reactive hardness ions Hardness forms nanocrystals on the media s surface

TAC- How It Works Nano-Crystals grow to a certain size Once large enough, the crystals release from the bead as deactivated Nano- Crystals (scale)

Change in Free Ca Ions as a Function of Flow rate

Nano-Crystal Stability After 2 days the water will re-dissolve the crystal back into solution and it is now able to form scale again. This is why TAC medias is not recommended for closed loop applications.

Types Calcium Carbonate of Scale Aragonite- Soft Scale (Treated) Calcite- Hard Scale (Untreated)

Arizona State University Test for Calcium Scale Prevention

Arizona State University Test for Calcium Scale Prevention

ASU Heat Exchanger Pictures from Test Untreated Water 60 deg C TAC Treated Water 60 deg C

TAC Media Certifications Some TAC Medias have been certified to the following NSF/ANSI Standards: NSF/ANSI Standard 61- Drinking Water Component Health Effects NSF/ANSI Standard 372- Lead Free Some TAC medias have been tested by independent agencies based on the test by the German Technical and Scientific Association for Gas and Water for DVGW W-512.

TAC Media Certifications The German Technical and Scientific Association for Gas and Water for DVGW W-512. A water supply is split: treated and untreated. Each is sent across a heating element for a period of time. After the test a calculation is run to determine the effectiveness.

TAC Media Systems Consistent scale control performance No chemicals required Commercial and residential applications Water chemistry is not changed Small space requirements Zero waste or consumables

TAC Systems- Tank and Cartridge Style TAC Systems are currently present in the market as Cartridge Based Systems up to 6 GPM and Tank Based systems 10-75 GPM.

System Cutaway Idle service Service service TAC Media Fluidized Bed of TAC Media feed feed

TAC Systems- Tank and Cartridge Style TAC Medias are generally rated for 4 gallons per minute per liter of media..25 Liter cartridge = 1 GPM 4 Liter Tank System = 16 GPM

Cartridge Type-POU Cartridges TAC Cartridge: 2.5x10 1 GPM 2.5x20 2 GPM 4.5x10 3 GPM 4.5x20 4 GPM 4.5x20 6 GPM

Tank Type POE Residential Systems TANK SIZE (IN.) LITERS OF MEDIA 8x35 2 10 9x35 3 12 10x54 4 15 12x52 5 20 13x54 7.5 25 SERVICE FLOW RATE GPM 8X35-13X54 14X65-16X65

Tank Type POE Commercial Systems TANK SIZE (IN.) LITERS OF MEDIA SERVICE FLOW RATE GPM 7x44 2.5 10 8x44 3 12 9x48 4 16 10x54 5 20 12x52 7.5 30 14x65 12.5 50 16x65 19 75 7X44-12X52 14X65-16X65

High Flow POE Commercial Systems Model 2x 1465 2x 1665 3x 1665 5x 1465 4x 1665 5x 1665 6x 1665 Service Flow 100 GPM 150 GPM 225 GPM 250 GPM 300 GPM 375 GPM 450 GPM Follow the sizing charts and do not oversize

Food Service Applications Convection Steamers and Combi-ovens Water Heaters Ice Machines Proofer Ovens Coffee Brewers Espresso / Coffee Equipment Post Mix Dishwashers

Commercial, Hospitality and Agricultural POE Water Treatment Applications Water Heaters Tankless Water Heaters Boilers (Hot Water Boilers not Steam Boilers) Solar Heating Systems Piping Systems Mixing Valves Humidifiers / Evaporators Irrigation System Spray Heads Misting Systems

Reverse Osmosis Pretreatment There has been a number of successful commercial reverse osmosis installations using TAC media as scale prevention. Guideline- Use city water as make up because it is regulated by the EPA and run at 50% recovery. A Pilot is recommended on any municipal water supply that qualifies as a first time application.

Guidelines- Feed Water Minimum pressure 15 PSI (1.03 bar) Maximum pressure 125 PSI (8.75 bar) Minimum operating temperature 34 F (1.1 C) Maximum operating temperature 120 F (60 C) Water ph range 6.0 to 9.0 Maximum feed water hardness is 25 grains per gallon for residential and 75 grains per gallon for commercial Maximum chlorine < 2 ppm, de-chlorination recommended Maximum copper- None Allowed

TAC Guidelines- Feed Water Maximum iron.3 ppm Maximum manganese.05 ppm Maximum silica 10 ppm Hydrogen Sulfide and phosphates should not be present Oil and grease should not be present

TAC Guidelines TAC is a physical water treatment devise. It does not soften water and it is not a salt free water softener. It does not change the hardness of the water. It does not prevent water spotting or mineral residue build up on areas that are repetitively wet and dry. That is a product of evaporation. Adding chemicals to water that has been treated by TAC may counter its treatment effects. Systems installed on or above a second story should also have a vacuum breaker. If installed in new construction new copper lines should be allowed to passivate for a period of 4 weeks prior to placing the TAC system into service Do not install after copper/zinc redox alloy media

TAC Guidelines It should not be used on a closed loop system. TAC should not be used on steam boilers Multiple tank systems should be installed in parallel with a PVC or CPVC manifold system designed to meet the peak flow requirements. Flex connectors should be put on the inlet and outlet of systems where the hard field piping is rigid and not allowed to flex. Do not oversize the system. It needs to be sized according to flow rate to achieve bed lift. Incoming water should be tested to meet the influent water chemistry requirements Water containing heavy loads of dirt should be prefiltered prior to the system.

Media Life Span Residential media life is 3 years Commercial media life is 3 years Cartridge filter life is 1 year Tankless water heater cartridge products life is 2 years

TAC Systems- Installation Recommendations Flex connectors for 2 systems should be used on commercial 14 and 16 installations where the installation will not allow for piping to flex.

TAC Systems- Installation Recommendations Anytime TAC systems are installed above the ground floor of a building it is recommended that a vacuum breaker also be installed, to protect against tank collapse, in the event the plumbing system is drained. If a vacuum breaker is not used then the system should be placed in bypass anytime the plumbing system is drained.

Thank You QUESTIONS???