Electrical Actuators

Similar documents
Thermostatic Actuators

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators

Digital input modules

Actuator for modulating control AME 435

RRV934. Multi-controller. Synco living

HERZ-Thermal Actuators

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Adjustable room thermostat for heating only or cooling only systems

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TX OPEN RS232/485 module

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Butterfly Valves PN 6/10/16 for flanged connection

Electric Rotary Actuator - On/Off or programmable control actuator

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

2- and 3-port valves with flanged connections, PN 10

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Product and functional description

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Emergency lighting units EM powerled

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

ACS-30-EU-EMDR-10-MOD

Heating Controller. Building Technologies HVAC Products

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Flush-mounted room thermostats

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

3/2-way Solenoid Valve, direct-acting, NC or NO

Proportional pressure regulators VPPE

Assisted lift operated 2/2-way solenoid valves Type EV250B

IO-RM3 3-Stage Relay Module

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Infrarot-Bewegungsmelder IP44

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT Features

IO-DIM6 6-Channel, Digital to Analogue Converters

Series 71, 72, and 76 Modutrol IV Motors

Quick Connect. quick - simple - efficient.

Series 7500 Torque Sensor

Combi switchbox with integrated 3/2 way pilot valve

Electronic Control Devices The European Product Catalogue 2007

WE-350 Series ¼ Turn Electric Actuator

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

4/2-Way Pneumatic Solenoid Valve

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Electronic Pressure Switch EDS 3000

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Duct Humidity Transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Pressure Switch EDS 300

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

MasterINTERFACE 39 Series - Relay interface modules

Cable Plug acc. to DIN EN , Form A

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Drayton Digistat +2RF/+3RF

BITMAIN. APW PSU Series User Guide

650W Single Output Power Supply

Room Temperature Sensors

Digital display DA 48

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

User Manual for CH-PFC76810

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Single sub-base valve

Redundancy Module QUINT-DIODE/40

VAV compact controller KNX / PL-Link

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

EFC Frequency converters

Operating Manual UWAPS-TINY Series

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Voltage Regulator SPAU 341 C. Product Guide

Modular I/O System Analog and Digital Interface Modules

J TB/TW Temperature limiter, temperature monitor

EGSTON Standard E2xFxWx 12W

Digital inductive conductivity transmitter

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

38 Series - Relay interface modules A

Problem / Solution. The problem:

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Transcription:

4 893 SSA without auxiliary switch SSA1 with auxiliary switch Electrical Actuators for radiator valves VD, VE, VU, VPD, VPE SSA31 SSA81 SSA61 SSA31 operating voltage AC 230 V 3-position control signal SSA81 operating voltage AC 24 V 3-position control signal SSA61 operating voltage AC/DC 24 V DC 0 10 V control signal ominal force 100 Automatic identification of valve stroke Direct mounting with coupling nut, no tools required Basic types complete with plug-in connecting cable, length 15 m Extra types for special cable lengths Manual override and position indication Parallel connection of multiple actuators possible Auxiliary switch AC 250 V / 1(05) A integrated in SSA311 and SSA811 actuators Optional tamper-proof fitting to prevent dismantling Use For Siemens radiator valves VD, VE and VU For Siemens-MiniCombiValves (MCV) types VPD and VPE For radiator valves supplied by Heimeier, Cazzaniga, Oventrop M30 x 15, Honeywell-Braukmann, M and TA-Type TBV-C (all without adapter) For radiator valves with actuators fixed with a M30 x 15 union nut, nominal closing dimensions 116 ± 03 mm and nominal stroke 25 mm (without adapter) With the appropriate adapter types AV, the actuators can also be used with valves from other manufacturers (refer to «Type summary / accessories») CE14893en 23022005 Building Technologies HVAC Products

Type summary Type reference Operating voltage Run time at 50 Hz Control signal Connecting cable Auxiliary switch SSA31 1) 15 m o SSA31/00 2) AC 230 V no cable o SSA311 1) 15 m es 150 s 3-position SSA81 1) 15 m o SSA81/00 3) AC 24 V no cable o SSA811 1) 15 m es SSA61 1) 15 m o AC / DC 24 V 34 s DC 010 V SSA61/00 3) no cable o 1) 2) 3) Basic types complete with cable Alternatively, actuators can also be ordered without cable (types SSA/00), refer to 2), 3) and «Accessories» Extra type for other cable lengths (refer to «Accessories») and as a replacement Extra types for other cable lengths or terminal block connectors (refer to «Accessories») and as a replacement Accessories Type reference 1) AS3L15 AS3L25 AS3L45 AS8L15 AS8L25 AS8L45 AS6L15 AS6L25 AS6L45 AS98 AS99 AS100 AL40 Description Operating voltage Control signal Connecting cable 15 m Connecting cable 25 m Connecting cable 45 m Connecting cable 15 m Connecting cable 25 m Connecting cable 45 m Connecting cable 15 m Connecting cable 25 m Connecting cable 45 m Retaining screw for terminal block connectors AC 230 V AC 24 V AC / DC 24 V Terminal block connector for 3-position actuators SSA81 3-position DC 010 V Terminal block connector for DC 0 10 V modulating actuators SSA61/00 Tamper-proof fitting to prevent dismantling of actuators Adapter type for third-party valves Adapter type for third-party valves AV51 Beulco old (M30x10) AV56 iacomini AV52 Comap AV57 Herz AV53 Danfoss RA- (RA2000) AV58 Oventrop old (M30x10) AV54 Danfoss RAVL AV59 Vaillant AV55 Danfoss RAV AV60 TA 1) o adapter required for type TBV-C AV61 Markaryd Ordering Example When ordering, please give quantity, product name and type reference 2 actuators SSA81/00 without cable and 2 connecting cables AS8L45 Delivery Equipment combinations 2/8 Actuators, valves and accessories are packed separately Type reference Valve type k vs [m 3 /h] P class Data sheet VD, VE, VU Radiator valves 009141 2105, 2106 P 10 VPD, VPE MCV radiator valves 002048 2185 For other radiator valves with type AV adapters refer to «Type summary / accessories» Radiator valves (M30 x 15) from other manufacturers, without adapter: Heimeier M Cazzaniga TA type TBV-C Oventrop M30 x 15 (from 2001) Junkers Honeywell-Braukmann k vs = nominal flow rate of cold water (530 C) through the fully open valve (H 100 ) at a differential pressure of 100 kpa (1 bar) Building Technologies Electrical Actuators CE14893en HVAC Products 23022005

Valves from other manufacturers To ensure trouble-free operation of third-party valves with the SSA actuator, the valves must satisfy the following requirements: F x 90187 y Threaded connections with coupling nut M30 x 15 ominal force 100 Dimension x (with valve fully closed) > 90 mm Dimension y (with valve fully open) 145 mm A M30 x15 AB Function / mechanical design When the actuator is driven by DC 0 10 V control voltage or by a 3-position signal, it produces a stroke which is transmitted to the valve stem The description of operation in this document applies to the valve versions which are fully open when deenergized (O) 3-position control signal SSA31 / SSA81 Voltage at 1: Stem retracts Valve opens Voltage at 2: Stem extends Valve closes o voltage at 1 and 2: Actuator maintains its current position DC 010 V control signal SSA61 Features and advantages The valve opens / closes in proportion to the control signal at At DC 0 V, the valve is fully closed (A AB) When power supply is removed, the actuator maintains its current position Locking-proof, maintenance-free gear train Reduced power consumption in the holding positions Load-dependent switch-off in the event of overload and in stroke limit positions Terminal block connectors for special cable lengths available (only for use with AC 24 V and AC / DC 24 V actuators) Connecting cables with AC 24 V and AC 230 V connectors cannot be mixed up 4893Z16 Accessories Adapter type AV for third-party valves Adapter types AV51 to AV61 are available for mounting the SSA actuators on thirdparty radiator valves as shown under «Type summary / accessories» Tamper-proof fitting AL40 01422 4893Z15 01417 01414 1x 1x a b a b tighten gently Building Technologies Electrical Actuators CE14893en HVAC Products 23022005 3/8

Retaining screw AS98 4864Z02 Type AS98 to secure the cable connector b c d The cable connector snaps into position, but can be additionally secured with the retaining screw 4864Z03 Terminal block connectors AS99 AS100 4864Z04 For special cable lengths of the AC / DC 24 V actuators Typ AS99 for 3-position actuators SSA81/00 Typ AS100 for DC 0 10 V modulating actuators SSA61/00 The terminal block connectors are supplied complete with Mounting Instructions (74 319 0385 0) otes Engineering Mounting Caution The actuators must be electrically connected in accordance with local regulations (refer to «Connection diagrams») Regulations and requirements to ensure the safety of people and property must be observed at all times! The permissible temperatures (refer to «Technical data») must be observed The connecting cable of the actuator may come into contact with the hot valve body, provided the temperature of the valve body does not exceed 80 C Actuator types SSA 311 and SSA811 have a built-in auxiliary switch The switch cannot be fitted in other actuators later The Mounting Instructions 74 319 0446 0 are enclosed in the product packaging Assembly is made with the coupling nut; no tools or adjustments are required The actuator must be fitted in position 1 (also refer to «Manual override»): Position the actuator and tighten the coupling nut manually Do not use any tools such as wrenches Avoid lateral pressure or (cable) tension on the mounted actuator! In the case of actuators without connecting cable (SSA/00), the separately ordered terminal block connector and connecting cable must be fitted Orientation 90 90 4362Z01 Commissioning When commissioning, check the wiring and the functioning of the actuator and auxiliary switch, if fitted Actuator stem extends (from position 1 to 0): Valve closes Actuator stem retracts (from position 0 to 1): Valve opens 4/8 Building Technologies Electrical Actuators CE14893en HVAC Products 23022005

Self-calibration Caution During commissioning and every time power is applied to the SSA61, the actuator carries out a self-calibration (valve stroke 0 max setpoint) o manual interventions are permitted during calibration Correct calibration cannot be guaranteed if the SSA is operated without a valve The second calibration attempt is started automatically after a pause of 8 min After three calibration attempts, the valve stem remains extended Before fitting the actuator to the valve, power supply must be turned off and the valve stem brought to position 0 via manual control After the actuator is fitted and power supply switched on again, self-calibration will be repeated To ensure calibration can be performed, the valve used must have a minimum stroke of 15 mm If the valve s stroke is < 1,5 mm, the actuator/valve combination remains blocked after three calibration attempts (valve stem extended) When the Siemens VD, VE, VU, VPD and VPE radiator valves are combined with SSA61 actuators, the flow rate preadjustment must be set to 15 mm valve stroke If the valve travel is less than 15 mm, self-calibration is not possible and the valve with the acturator remains blocked The new Siemens valves VD, VE and VU have 15mm stroke at every preadjustment Operation ote A 3 mm hexagonal socket wrench can be used to move the actuator to any position between 0 and 1 However, if a control signal from the controller is present, then this takes priority in determining the position To retain the manually set position, unplug the connecting cable or switch off the operating voltage and the control signal Manual override 3 mm B A 1 3 mm 0 1 0 3 mm 4893Z09 4893Z10 (, 1) A 4893Z08 B (, 2) Position indicator in position 1: Valve open Position indicator in position 0: Valve closed Maintenance Repair Disposal! The actuators are maintenance-free When carrying out service work on the plant, following must be noted: Turn power off (eg remove the plug) If necessary, disconnect electrical connections from the terminals The actuator must be commissioned only with a correctly mounted valve in place! SSA actuators cannot be repaired; the complete unit must be replaced The device must not be disposed of together with domestic waste This applies in particular to the PCB Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view Current local legislation must be observed Warranty The technical data given for these applications is valid only when the actuators are used with the Siemens valves listed under «Equipment combinations» If the SSA actuators are used with other valves, then the user is responsible for ensuring correct functioning 5/8 Building Technologies Electrical Actuators CE14893en HVAC Products 23022005

Technical data Power supply Operating voltage Voltage tolerance Frequency SSA31 SSA81 SSA61 AC 230 V ± 15% AC 24 V ± 20% 50 / 60 Hz AC 24 V or DC 24 V ± 20% ± 25% Max power consumption 6 VA 08 VA 25 VA Fuse for incoming cable (fast) Control Control signal 3-position DC 010 V Input impedance for DC 010 V > 100 kohm Positioning accuracy for DC 010 V < 2 % of nominal stroke Parallel operation max 6 max 24 max 10 (number of actuators) 1) Functional data Run time for 25 mm stroke at 50 Hz 150 s 34 s ominal stroke ominal force Perm temperature of medium in the connected valve 2 A 25 mm (max 55 mm) 100 1110 C (190 C for MCV-radiator valves) Electrical connections Connecting cable of basic types 15 m 3-core to E 60320 / IEC 60227 Industry standards Meets the requirements for CE marking: EMC directive Low-voltage directive 89/336/EEC Emissions E 61000-6-3 Immunity E 61000-6-2 73/23/EEC E 60730-1 Protection class to E 60730 II III Housing protection standard IP40 to E 60529 Dimensions / weight Dimensions refer to «Dimensions» Housing colors Auxiliary switch eneral ambient conditions Connecting cable Coupling thread to valve coupling nut M30 x 15 Weight without auxiliary switch with auxiliary switch Base Cover Mounted in SSA311 and SSA811 Switching point adjustable Factory setting 50% Switching capacity 1) Provided the controllers output is sufficient 03 kg 04 kg max AC 250 V, 1 A (05 A) RAL 7035 light gray 03 kg RAL 9003 signal white 1 change-over switch 0100 % Operation IEC 721-3-3 Transport IEC 721-3-2 Storage IEC 721-3-1 Environmental conditions Class 3K3 Class 2K3 Class 1K3 Temperature +1+50 C 25+70 C 5+50 C Humidity 585 % rh < 95 % rh 595 % rh SSA31 4864Z12en 7 6 4 white black blue 2 1 Control signal CLOSE (AC 230 V) Control signal OPE (AC 230 V) eutral SSA81 4864Z13en 7 6 1 orange violet red 2 1 Control signal CLOSE (AC 24 V) Control signal OPE (AC 24 V) System potential (AC 24 V) SSA61 4864Z14en 8 2 1 grey black red 0 Control signal DC 010 V (AC 24 V) System neutral System potential (AC/DC 24 V) 6/8 Building Technologies Electrical Actuators CE14893en HVAC Products 23022005

Connection terminals AS99 for SSA81 2 1 4864Z15 Control signal CLOSE Control signal OPE System potential AC 24 V AS100 for SSA61 0 4864Z16 System neutral Control signal DC 010 V System potential AC/DC 24 V Terminals for auxiliary switches SSA311, SSA811 Q14 Q12 Q11 80125 Factory setting: 050 % Q11 Q12 50 %1 Q11 Q14 The switching point can be adjusted by turning the switching cam with a screwdriver (see Mounting Instructions) Connection diagrams SSA31 L () Q1 (1) 2AF (L) Q2 (2) 4864A01 Controller Actuator L System potential AC 230 V System neutral Q1, Q2 Controller contacts AC 230 V 1 2 SSA81 SP 2AF () Q1 (0) (1) Q2 (2) 4864A02 Controller Actuator SP System potential AC 24 V S System neutral Q1, Q2 Controller contacts AC 24 V 1 2 S Building Technologies Electrical Actuators CE14893en HVAC Products 23022005 7/8

SSA61 SP (+) AC 24 V (DC 24 V) 2AF () () (0) 4864A03 SP S Controller Actuator System potential AC 24 V System neutral 0 S (-) Dimensions Actuator without auxiliary switch SSA31 SSA81 SSA61 Dimensions in mm 77 M30 x 1,5 83 725 9 48 4893M01 Actuator with auxiliary switch SSA311 SSA811 985 895 48 M30 x 1,5 9 83 4893M02 8/8 2005 Siemens Switzerland Ltd Subject to alteration Building Technologies Electrical Actuators CE14893en HVAC Products 23022005