SENATOR CH. Condensing Central Heating Boilers 400 & 550 kw

Similar documents
High-efficient gas boiler CompactGas

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

UDSA - UDSBD unit heater

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

HAPERO BALANCE / FLASH. 15 kw / 25 kw / 35 kw. Basement Floor Living room ENERGIETECHNIK GMBH PLUG INSTITUT FÜR BRANDSCHUTZTECHNIK

A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

HEAVY DUTY STORAGE GAS

E-gas Instant Gas Water Heaters

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Daikin Altherma Hybrid Heat Pump

ELECTRIC CENTRAL HEATING FLOW BOILER

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Electric Flow Boiler

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Screw Compressors ESM Fixed Speed & VS Variable Speed

Heating with wood chips and pellets

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Heating Controller. Building Technologies HVAC Products

Aludesign K A T A L O G

Heating, air-conditioning, cooling

Commercial Gas Furnace Upflow

Rotary screw compressors kw 5,5 7, , bar MODULO

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

United Kingdom en. ErP information. Gas fired condensing boiler Gas 210 ECO PRO

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

The natural ombination

Unico Inverter. Unique and efficient.

Natural geothermal energy.

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

york air-conditioning products Residential & VRF News 2015

Brochure EX

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

User's Instructions. Alpha HE CB25/33 and HE SY25

Screw Compressors 11-22kW

FULL DC INVERTER SYSTEMS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Laddomat Charging unit

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

Hot Water. Heat pump water heaters. Residential and Commercial R410a

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

Boiler efficiency for community heating in SAP

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

The Concept of Condensing Boilers

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Daikin Altherma hybrid heat pump. The natural combination

HIGH QUALITY COMPONENTS

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -


Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Conlift1, Conlift2, Conlift2 ph+

EcoDesign & Labelling Directive (ErP)

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Versati Air to Water Heat Pump

Apartment and Communal Heating Solutions

How to choose a heat pump and use it wisely

AMTRON E-30 Compact heat and cooling meter

IV. Rear Mount System

The compact unit series

1 DESCRIPTION OF THE APPLIANCE

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

LG Electronics AE Company, Commercial Air Conditioning

Split units TH with hermetic compressors

Refrigeration Compressed Air Dryer Buran Ultrapulse

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Description of functions

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Clearly Hybrid system

Half the cost Half the carbon

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet.

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Electronic Control Devices The European Product Catalogue 2007

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Material test chamber with mechanical convection

Printing and Publishing Energy Savings Guide

ECOplus Solar Cylinder

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

industry revolves around

ECOCIAT. Domestic hot water heat recovery unit

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Gas Boilers - Commercial

Aerona Air Source Heat Pumps

ROTARY SCREW COMPRESSOR. RMD kw

High Efficiency Boiler Range Technical Guide

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ROTEX gas hybrid heat pump. A strong team.

Transcription:

SENATOR CH Condensing Central Heating Boilers 400 & 550 kw

Compact, robust and reliable The ultimate commercial boiler Senator is the ultimate commercial boiler from Eco Heating Systems. This range consists two types of condensing floor standing boilers with capacities of 400kW and 550kW. In a cascade set up with 6 Senators it is easy to generate a capacity of 3.3mW in an area of around 6,5m². High efficiency The Senator boiler is an high efficient product with two special pre-mix burners which result in a great modulation ratio of 1:8. When combined with appropriate regulation equipment, it results in great savings in the energy consumption without any effect on the ambient temperature. Reliable Advantages at a glance High Unique capacities: 400 and 550kW Operates on both natural and propane gas Robust, reliable and durable Space-saving dimensions: 3.3mW in 6,5m Modulation range 1:8 Double premix burner Built-in cascade controller for up to 6 boilers Built-in weather dependant temperature control Built-in 0-10V DC control connection Built-in Open-Therm connection Quick and easy installation Remote boiler status signal for Operating & Fault indication due to its 2 potential free contacts Suitable for Building Management Systems via 0-10V connection (BMS) Easy maintenance State-of-the-art boiler design and use of high quality components make Senator very reliable. However, by integrating a two-chambered heat-exchanger, Eco Heating Systems offers more extra comfort and reliability. Unique flue diameters Senator is equipped with two strong ventilators which make it possible to integrate a flue outlet of 180mm in diameter on the boiler. Due to this flue diameter, Senator excellently finds its place in the renovation projects. Possibility of installing the new flue piping into the existing flue-gas channels ensures savings from the renovation cost.

Your partner in central heating You can rely on us Built-in c ascade controller The Senator range is fitted with an integrated cascade control unit, which can sequence up to four boilers to their optimum efficiency without utilizing an external controller. For this reason, it is possible to set up an installation of 2.2 mw in an area of around 4,5m². Easy installation Senator is designed to be installed easily. Due to its space-saving design, it can be moved through standard doors without any problem. Furthermore, with two small wheels mounted under the boiler casing, Senator is very easy to relocate and fit in different spaces which makes it an optimal solution for renovation projects where space is limited. Low noise level Senator is a very silent boiler with its acoustic level limited to 46 dba. OEM solutions Having a great experience in manufacturing and development of highefficiency commercial boilers, Eco Heating Systems offers the possibility of private labelling to its partners. It is either possible to take one specific range or the whole assortment of boilers and name it your own brand. Besides private labelling, it is also possible for our partners to play an active role during the product deve lopment. Technical departments of our current partners have close contacts with our R&D department. Because of this very precious input from all our partners worldwide, we can always ensure that our boilers maintain the highest quality stan dards.

Controllers Controllers & thermostats In general, different zones of large commercial buildings have different heating requirements. The sunny party of the building requires less heat compared to those in shade or the production area should be cooler than the offices. Eco Heating Systems offers the EBC controller to tackle this problem. Equipped with the feature of giving each group a possibility to connect its own thermostat, this controller can be regulated/set according to the ambient heat required by the user. Spaces that do not require heat demand, will not be heated unnecessarily which dramatically reduces the amount of fuel used and provides considerable energy savings. Outside temperature control With an optional outside temperature sensor, Eco Heating Systems boilers can also be regulated depending on the outside temperature. When the temperature changes outside, this information is sent to the boiler through the outside temperature sensor. Then accordingly, the boiler makes necessary adjustments in the room temperature, preventing extra fuel consumption. Building management systems Eco Heating Systems boilers can completely be integrated into Building Management Systems (BMS) via the integrated 0-10V control connection.

Dimensions Dimensions Senator 400 & 550 kw 736 1096 644 476 263 111 C 70 D 1687 150 135 A E 70 B F G 568 225 258 135 1200 689 814 Connection Function Diameter connection in inch/mm. Senator 400 CH Senator 550 CH A Flow G 2½" G 2½" B Return G 2½" G 2½" C Cable feed Ø 22.5 Ø 22.5 D Supply air connection Ø 180 Ø 180 E Flue terminal Ø 180 Ø 180 F Gas connection G 2" G 2" G Condensate discharge hose Ø 25 Ø 25

Dimensions (h x w x d) mm 1685 x 736 x 1225 II2L3P Gas Appliance Type B23; C13X; C23X; C33X; C43X; C53X; C63X; C83X Type Boiler S 400 S 550 CH-Water content Liter 30 43 Weight (empty) Kg 400 450 mm 180/180 180/180 Central Heating Nominal input min kw 50-400 68-550 Nominal input max. kw 55,5-444,2 75,5-610,8 Nominal output at 100% 80/60ºC kw 48,3-386,4 66,1-535,2 Nominal output at 100% 50/30ºC kw 52,2-417,6 71,2-576,4 Nominal output at 30% 36/30ºC kw 54,1-432,5 73,7-596,8 % 109,5% Technical Data Available pressure for the Flue system Pa 200 200 ºC 90 Pressure CH-system min./max. Bar 1-4 Standard components Cascade manager for 6 boilers Standard Open Therm connection Standard 0-10 Volt connection Standard Weatherdependant temperature controller** Standard ** Outside temperature sensor is an ancillary and must be purchased seperately Eco Heating Systems B.V. Postbus 5145 Rigaweg 10 Nederland 9700 GC Groningen 9723 TH Groningen T: +31 (0)50 547 0470 F: +31 (0)50 547 0498 I : www.ecohs.nl E: office@ecohs.nl Eco Heating Systems is a dynamic company, focusing on development and production of commercial condensing boilers and direct-fired commercial condensing gas water heaters. Combining our significant experience in the commercial heating field with the requirements of our partners, we have been producing superior quality products suitable for any commercial installation. Our equipment, systems and services are dedicated to helping our partners to optimize the performance of their processes Version : EN 2010-S0001