Flow Divider and Flow Divider/Combiner Valves

Similar documents
Pressure Relief and Regulating Valves

Example. Fluid Power. Circuits

Check Valves, Flow Control and Priority Flow Control Valves

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

Unit 24: Applications of Pneumatics and Hydraulics

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

PART 2 FORKLIFT HYDRAULIC SYSTEM

ROTARY GEAR FLOW DIVIDERS

COUNTERBALANCE VALVES

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Flow divider (flow distributor), type TQ

Hydraulic Flow Control Valves

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Unit 24: Applications of Pneumatics and Hydraulics

Quiz On Information Learned From Chapter 1

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Series Hose Reels

SIMPLIFIED VALVE CIRCUIT GUIDE

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Series TMM Axial Piston Motor. Technical Information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

SIMPLIFIED VALVE CIRCUIT GUIDE

Real Time Simulation for Off-Road Vehicle Analysis. Dr. Pasi Korkealaakso Mevea Ltd., May 2015

HYDRAULICS AND HWH SYSTEMS

The Secret of Hydraulic Schematics. BTPHydraulics

Why and How we Use Capacity Control

Rexroth Hydraulic Pump A10VO Series User Manual

Unit 24: Applications of Pneumatics and Hydraulics

Uniquely designed and engineered specifically for the pulp and paper industry.

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

scx-180 Control focused technology driven SCX valve series SSL-1000 REV 04/09 - SUPERCEDES REV 01/08

Belt Drives and Chain Drives. Power Train. Power Train

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Hydraulic Trouble Shooting

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Series PVP Variable Volume Piston Pumps

Control block EDD Modular Directional Valve

Pump Ratio and Performance Charts

Variable Displacement Pump AA10VSO

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Check Valves Valve locator

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

STANDARD INTEGRATED POWER STEERING

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

MAXIMIZING THE OUTPUT OF YOUR BRAKES Getting Your Pedal Geometry Right

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

C. starting positive displacement pumps with the discharge valve closed.

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Chapter 5: Flow Valves

Oil and Coolant Circulating Heating System. Model - OCSM

Hydraulic Troubleshooting PRESENTED BY

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T

Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Unit 24: Applications of Pneumatics and Hydraulics

Troubleshooting Guide for Jacks Down LED Lights

A Descriptive Summary of Vickers Inline Pumps and their Applications

Gas Custody Transfer Calibration

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

High Torque Vane Motors MV015, MV037, MV057, MV125

NITROUS TRANSFER PUMP INSTRUCTIONS

SUPER 600. Tracked Paver SUPER 600. Pave Widths 0.5m 2.7m. Maximum Laydown Rate 200 tonnes/h. Clearance Width 1.2m

1. SYSTEM OVERVIEW. 1) Basic Theory of ABS Function

LINEAR ACTUATORS. Linear Actuators. Linear Actuators. Linear Actuators are Actuators that creates motion in a straight line, as contrasted

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

DOUBLE DRUM TRACTION WINCH SYSTEMS FOR OCEANOGRAPHIC RESEARCH 1.0 TRACTION WINCH SYSTEM ADVANTAGES 11-2

Industrial Steam System Process Control Schemes

Manufacturing Equipment Modeling

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

Class 5 to 7 Truck and Bus Hydraulic Brake System

BRUSHHOLDERS AND THE PERFORMANCE OF CARBON BRUSHES

Selecting and Sizing Ball Screw Drives

VEHICLE SPEED CONTROL SYSTEM

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

Automatic Transmission Basics

General Background. Closed Circuit Hydraulic Systems. Closed Circuit Hoisting. Safety Problems with Closed Circuit Hoisting

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Pump Shaft Sleeves - Stratford Engineering

Choosing Between Electromechanical and Fluid Power Linear Actuators in Industrial Systems Design

Trouble Shooting Tech Tips Operation

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Transcription:

Flow Divider and Flow Valves Applications There are two types of flow dividers and flow divider/combiners: Sliding spool Rotary (usually gear) Each type has its own set of performance characteristics: Flow range Pressure capability Accuracy Unique application parameters Sun offers sliding spool, pressure-compensated flow dividers and flow divider/combiners which can be used to split or combine flow in a variety of applications. These cartridges are simple devices, both in appearance and operation. The flow dividers incorporate just one moving part, while flow divider/combiners have up to three moving parts. Be aware that simplicity of design and construction does not necessarily lead to application simplicity when it comes to specifying these devices. When using Sun spool type flow dividers and flow divider/ combiners, several areas of application sensitivity must be taken into consideration. Flows below the designated operating range, entrapped air, and/or contamination can cause these devices to produce inaccuracies larger than the individual cartridge-specified tolerance limits. In all flow divider and flow divider/combiner applications, inaccuracies are cumulative. Although two or more devices in series will perform within the stated accuracy limits, the cumulative effect on accuracy must be considered as to how it will affect overall system performance. Two of the most common application areas include multiple cylinder circuits and hydraulic motor circuits. Cylinder Applications In the dividing mode, pressure-compensated flow dividers (or flow divider/combiners) split flow within the valve s accuracy limits. Inherent design characteristics will cause the path with the highest load pressure to receive a higher percentage of the flow. If a rigid mechanism ties the cylinders together, the lead cylinder can pull the lagging cylinder and cause it to cavitate. In the combining mode, these devices will combine flow within the stated accuracy limits. However, the compensating characteristics will cause the leg with the lowest load pressure to receive a higher percentage of the flow. Synchronization at the end of the cylinder stroke is a must, or an additive accuracy error can be expected with each stroke. In applications where the mechanisms between the two cylinders turn out to be too rigid, operating inaccuracy will cause the eventual lock-up of the system, with potential damage to the mechanical structure. Hydraulic Motor Applications Hydraulic motor drive systems will be affected by the compensating characteristics in the same manner as cylinders. Rigid frames or mechanisms tying the motors together (mechanically synchronized motion of the motor s output shafts; e.g. wheels to the pavement, or sprockets to conveyers) will contribute to cavitation, lock-up, and pressure intensification. Variations in speed and/or possible lock-up can also be caused by differences in motor displacement, motor leakage, differences in wheel diameter, plus variations in the coefficient of friction between the wheels and driving surface. On multiple wheel drive vehicles, extreme pressure intensification can occur. For example, a four wheel drive vehicle going down a grade has all wheels gripping. Deceleration then induces a 3000 psi (210 bar) load on all four wheel motors. At this point, three of the four motors loose traction, causing the fourth motor to see a theoretical deceleration pressure of 12,000 psi (840 bar). Adding relief valves at the cylinder or motor ports will minimize the potential for pressure intensification along with its resulting system damage. Installing make-up (anti-cavitation) check valves at the cylinder or motor ports can help with the cavitation problem. Properly sized slip orifices in a tractive motor drive circuit can alleviate lock-up and allow for terrain variations or articulated steering. The bottom line is: Each flow divider and flow divider/combiner application must be thoroughly analyzed. Every consideration must be given to expected system performance under all possible operating conditions. Precautions must be taken in order to insure that none of the problems previously discussed can occur and affect the satisfactory performance of the entire system. Design Concepts and Features Sun offers seven sliding spool, pressure compensated flow dividers and flow divider/combiners, four standard accuracy higher flow versions, and three high accuracy lower flow versions. Input flows range from 0.3 gpm (1 L/min) to 80 gpm (320 L/min) with operating pressures up to 5000 psi (350 bar). (Be aware that with all versions there will be no dividing or combining when flows are below the minimum rated input flow. If flow starts at zero, the cartridge will essentially be a tee until the minimum flow rating is reached.) All seven versions are available in four frame sizes, with each frame size featuring a wider flow range than is typically found in other cartridge type flow dividers and flow divider/combiners. (The high accuracy versions are rated at approximately half the capacity of the standard accuracy units for a given frame size.) 1 Tech Tips:Web# 999-901-372 Rev. 06MAR09 2009 Sun Hydraulics Corporation

Flow Divider (Only) Cartridges FS*D, FSBD and FS*C Sun standard accuracy FS*D, plus high accuracy FSBD and FS*C flow divider cartridges, are suited for applications that use hydraulic motors or cylinders where flow division control is required in only one direction. (If reversal of the actuator direction is desired, a reverse flow check valve would be required.) In addition, they can be used where multiple circuits are serviced from one pump supply. (See Figures 1 and 2) Optimized performance Standard accuracy divisional tolerances range from +/- 3.5% at maximum rated input flow down to +/- 6.5% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. High accuracy divisional tolerances range from +/- 2.5% at maximum rated input flow down to +/- 4.5% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. Multiple flow split options (except for FS*C versions) 50:50, 40:60, and 33:67. (Regardless of split ratio, port 2 [outlet] always produces lower flow than port 4 [outlet].) Reverse flow path is unpredictable as these flow divider (only) cartridges are not designed to combine flow from the opposite direction. Closed Center Flow Cartridges FS*A, FSAA, FSBA and FS*G Sun standard accuracy FS*A and high accuracy FSAA, FSBA, and FS*G closed center flow divider/combiner cartridges can be used in applications that use hydraulic motors or cylinders where bi-directional flow division control is required. (See Figures 3 and 4) Optimized performance A unique closed center feature that will block flow when port 3 (inlet) is closed. Although the limited spool leakage between ports does not provide zero leak load holding capability, this feature can be helpful in minimizing crossport flow and drift. Standard accuracy divisional and combining tolerances range from +/- 3.5% of 50% at maximum rated input flow down to +/- 6.5% of 50% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. High accuracy divisional and combining tolerances range from +/- 2.5% of 50% at maximum rated input flow down to +/- 4.5% of 50% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. Figure 1. Use flow divider (only) cartridges to provide flow to two separate systems from one supply. Secondary systems can be tailored to three proportional flow requirements (i.e. 50:50, 40:60, or 33:67). Figure 2. Use flow divider (only) cartridges for two parallel hydraulic motors being driven only in one direction. Unequal speeds can be accomplished with motors of equal displacement using the 40:60 or 33:67 ratios. Motors with unequal displacement ratios that match either the 40:60 or 33:67 flow divider ratios, can be operated at the same speed, within the accuracy limits of the flow divider and the motors volumetric efficiency. Figure 3. For two hydraulic motors rotating at the same speed and in both directions, flow divider/combiner cartridges are the correct choice. However, if the application allows the motors to become mechanically linked during operation, it is recommended that relief valves, anti-cavitation check valves, or slip orifices be added to the circuit. 2 Tech Tips:Web# 999-901-372 Rev. 06MAR09 2009 Sun Hydraulics Corporation

Synchronizing Flow Cartridges FS*S, FSCS, FSDS and FS*R Figure 4. Closed center flow divider/ combiner cartridges will accurately split the flow into two cylinders in both directions and will provide limited load holding capability (cross-port leakage is limited to spool clearances). Synchronization at the end of stroke can be accomplished by adding cross-port relief valves. Cylinders must not be rigidly connected together! Sun standard accuracy FS*S, plus high accuracy FSCS, FSDS, and FS*R synchronizing flow divider/combiner cartridges allow synchronization of two hydraulic cylinders. After the first cylinder has reached the end of its stroke, a pressure-compensated reduced flow is metered to/from the second cylinder until it also reaches the end of its stroke. (See Figure 6) Optimized performance Bi-directional static error correction. Standard accuracy divisional and combining tolerances range from +/- 2.5% of 50% at maximum rated input flow down to +/- 4.5% of 50% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. High accuracy divisional and combining tolerances range from +/- 2.0% of 50% at maximum rated input flow down to +/- 3.5% of 50% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. Synchronization flow is equal to approximately 15% of minimum rated flow. Closed Center, High Capacity, Flow Cartridges FS*H Sun high capacity FS*H flow divider/combiner cartridges are primarily for use in tractive drive circuits. (See Figure 5) Performance High flow capacity. (30% greater than equivalent frame size standard flow divider/combiners.) Slightly lower accuracy than standard accuracy divider/ combiners. (Divisional and combining tolerances range from +/ - 4% of 50% at maximum rated input flow down to +/- 6.5% of 50% at minimum rated input flow, with 5000 psi (350 bar) differential between legs. A unique closed center feature that will block flow when port 3 (inlet) is closed. Differential slip for tractive drive systems must be created by adding orifices in the body/manifold. Use FS*H flow divider/ combiner cartridges, plus external slip orifices, in hydraulic motor tractive drive circuits. (Sun YG*B manifold assemblies include selectable slip orifices.) Motor port relief valves and anticavitation check valves should also be included in the final circuitry. Figure 6. Synchronizing flow divider/combiner cartridges will not only accurately split the flow to two cylinders in both directions, but will allow synchronizing at the end of stroke. However, Cylinders must not be rigidly connected together! Figure 5. 3 Tech Tips:Web# 999-901-372 Rev. 06MAR09 2009 Sun Hydraulics Corporation

Note: When using flow controls in conjunction with flow dividers, care must be taken with the orientation and position of the flow controls. See Figure 7 for further details. How to Use Flow Controls with Flow Dividers Figure 7. Allowable Flow control positions for bi-directional control of cylinder speed. In all cases, both flow controls must be either meter-in or meter-out, and have reverse free flow capability. 4 Tech Tips:Web# 999-901-372 Rev. 06MAR09 2009 Sun Hydraulics Corporation

Flow Divider and Flow Valves Overview Function Description Nominal Capacity Model Cavity Symbol Divider Divide Only FSCD FSDD FSED FSFD Divider Divide Only FSBD FSDC FSEC FSFC Closed Center FSCA FSDA FSEA FSFA Closed Center 0.3-1.5 gpm (1-6 L/min.) FSAA FSBA FSDG FSEG FSFG Closed Center High Capacity 2-10 gpm (8-40 L/min.) 4-20 gpm (15-80 L/min.) 8-40 gpm (32-160 L/min.) 15-80 gpm (60-320 L/min.) FSCH FSDH FSEH FSFH Synchronizing FSCS FSDS FSES FSFS Synchronizing 0.3-1.5 gpm (1-6 L/min.) FSAS FSBS FSDR FSER FSFR. 5 Tech Tips:Web# 999-901-372 Rev. 06MAR09 2009 Sun Hydraulics Corporation