LAARS COMBI HEAT. Combination Water Heaters with Heating Coils

Similar documents
Commercial Gas Water Heaters

Commercial Gas Water Heater

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Commercial Gas Water Heaters

Commercial Gas Water Heaters

Electric & Gas Water Heaters

High efficiency, cast-iron gas boiler

Gas-Fired, Residential Storage Type Water Heaters

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

PLBG/GAS SAFETY Information Bulletin

Light Duty Commercial Electric Water Heater

SPIDERfire: Delivers high efficiency and real savings for today s businesses

CHAPTER 9: WATER HEATING

Commercial Electric Water Heater

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

Cooling Capacity CFM in. w.c. (125 Pa)

ASME Packaged Indirect Fired Water Heater

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

NAVIEN AMERICA INC FITCH AVENUE

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

2010 Residential Water Heater Replacement Check List

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Commercial Gas Furnace Upflow

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Better Boilers.

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

Selecting a New Water Heater

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Using Water Heaters for Radiant Heat

Installation & Operation Manual Models: STU

SOLI TANKLESS PRODUCT GUIDE

Originators of the Flexible Water Tube design

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Commercial Electric Water Heater

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

TANKLESS DURABILITY Tankless Product Guide


GALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger

HEAVY DUTY STORAGE GAS

Hot Water Heating: Technologies and Use

Explosion-Proof Electric Unit Heaters

STATE-RES-GAS-State Residential Gas Water Heaters RW List Prices - Page T-1

F9MXE. Product Specifications

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

Tankless water heaters

G9MXE. Product Specifications

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

G234X-55 Conventional Gas Boiler

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

REGULATORS 175/153 Series

Techtanium Solar Indirect Water Heater Instruction Manual

WATER HEATERS. If your water heater tank is leaking, then your course is clear: buy a new unit. But if it isn t, your answer is less obvious.

Morrison Bros. Co. General Product Specifications

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

Operators manual Basic water heater

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

In-Line Air Separators

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Commercial Storage Tanks

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Domestic Hot Water Systems and Plumbing Products

CONDENSING TANKLESS WATER HEATERS

Residential Gas and Electric Water Heaters

RECON WATER HEATER INSTALLATION FORM

SOLID. STATE. StateWaterHeaters.com

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Trin & Stor Model Numbers: ST Series Version Date:

ECOplus Solar Cylinder

1 DESCRIPTION OF THE APPLIANCE

Technical Data Manual Model Nos. and pricing: see Price List

AMX300 DirectConnect Mixing Valve Kits

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

CARING FOR YOUR WATER HEATER

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

FLASH TANK ECONOMIZER PRODUCT GUIDE

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

NFPA31FuelOilPiping 1 Revised

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

Residential 30, 38, 40, 50 and 60 Gallon

Solar Skies Stainless Tank Series Water Heater

Installation Operation Maintenance

SunMor SM-V30 Solar Water Heater Installation Manual

Steam System Best Practices Condensate System Piping

Water Heater Safety Tips

Transcription:

LAARS COMBI HEAT Combination Water Heaters with Heating Coils

Dual-Purpose Performance Water Heaters from Laars Heating Systems Company Get the Laars Combi Heat water heaters for combined space and water heating. These models heat the potable water in the tank. Heat from the hot water is efficiently transferred through the heat exchanger to the fluid within the coil for use in radiant heating or other heating applications. Laars combination water heaters provide space heating and plenty of potable hot water. These energy efficient water heaters save both money and valuable interior space. COMBINATION SPACE AND WATER HEATING SYSTEMS Combination space and water heating systems consist of a storage water heater, a heat delivery system (for example, radiant panels, a fan coil or hydronic baseboards) and associated pumps and controls. The water heater is installed and operated as a conventional water heater. When there is a demand for domestic hot water, water enters the bottom of the tank and hot water from the top of the tank is delivered to the load. When there is a demand for space heating, a pump circulates water through the coil inside the tank, and out to the heat emitters. The storage tank is maintained at the desired temperature for domestic hot water. Because this temperature is cooler than conventional hydronic systems, the space heating delivery system needs to be slightly larger than typical. Alternatively, the storage tank can be operated at a higher water temperature; this requires tempering valves to prevent scalding at the taps. HYDRONIC HEATING SYSTEMS Hydronic heating systems use circulating water to distribute heat energy to the space. They typically use baseboard convectors, fan coils or radiant panels (such as ceilings, floors or walls) to transfer heat throughout the room.

Combination vs Conventional HEATING SYSTEMS Combination ENERGY USE & EMISSIONS: Reduced energy use and emissions by 15% or more Conventional ENERGY USE & EMISSIONS: Typically meets code for energy use and emissions SPACE: Reduced space requirements due to elimination of separate boiler and vent or chimney stack chase SPACE: Requires 2 to 4 square feet per unit for separate boiler and vent stack chase INSTALLED COST: Units cost more, but installation costs are reduced due to elimination of separate boiler INSTALLED COST: Cheaper units, but higher installation costs O&M COST: Replacement costs are reduced due to elimination of separate boiler to maintain or replace O&M COST: Maintenance costs are higher UTILITY COSTS: Reduced by 15% or more INSTALLATION Water heaters with space heating capacity require sophisticated controls, so installation requires specialized skills with each particular system. These systems are appropriate for both new construction or retrofit applications. BENEFITS/COSTS Some state and local jurisdictions offer rebates and tax credit programs that could help lower costs. Also, fewer moving parts allow easier maintenance and less service. Since only one source of heat is required, multiple utility hook-ups are not required.

LAARS COMBI HEAT WATER HEATERS Laars Heating Systems Combi Heat water heaters featuring a glass-coated, double-wall heat exchanger coil are the next generation of combination water and space heating products. The Laars Combi Heat is the perfect system to provide home space heating and potable hot water from a single energy-saving source. Laars Combi Heat conventional water and space heaters are available in capacities of 50 and 75-gallons. The 50-gallon model comes equipped with an extremely safe, reliable and maintenancefree Flammable Vapor Ignition Resistance (FVIR) system. The Laars Combi Heat FVIR Flammable Ignition Resistant Models Feature (50 gallon model only): Advanced Flame Arrestor Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. Resettable Thermal Switch Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow. Pedestal Base Rugged and durable base allows easy transport and positioning, and provides corrosion resistant contact with floor. Maintenance Free Regular cleaning of air inlet openings or flame arrestor is not required under normal conditions. Sight Window Offers a view into the combustion chamber to observe the operation of the pilot and burner. Piezo Igniter Easy and quick lighting of the pilot burner by push button. All Laars Combi Heat Models Feature: Heat Exchanger Double wall 1 1 2" O.D. glass-coated steel coil ensures separation of potable water and heating fluid. Low Heat Exchanger Head Loss Up to 10 GPM flow, with less than 5 ft. of head loss. Greatly reduces the required pump size for heat exchange. Glass Lined Tank Laars Heating Systems water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. Fully Automatic Controls Builtin energy cut-off switch prevents abnormally high water temperature for extra safety. Builtin gas pressure regulation. Steel Tank Heavy gauge steel automatically formed, rolled and welded to assure a continuous seam for glass lining. Thermostatic Mixing Valve Supplied with unit to help prevent injury due to scalding. Protective Aluminum Anode Rod Provides added protection against corrosion for long trouble-free service. Flue Baffle Designed to maximize the amount of heat absorbed in the lower portion of tank. Reduces air movement in the heater during standby periods to retard heat loss up the flue. Factory Installed Sediment Reduction System Cold water inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build-up at top of tank. Water Connections 3 4" NPT factory installed true dielectric fittings. Extends water heater life and eases installation. 2" Non-CFC Foam Insulation Surrounds the tank surface, saving energy by retarding loss of heat. T&P Relief Valve Installed. Brass Drain Valve. Design Certified by CSA International (formerly AGA/CGA).

LAARS COMBI HEAT WATER HEATERS C A D & G K J H E F B Note: LCH-75T will not have a pedestal base LCH-504T10 LCH-75T10 Model Number FBN FCX BN CX Water Heating FHD 105 100 CA EF Space Heating CA AFUE % Max. Heating Capacity.55.55.52.52 80.0 80.0 82.0 82.0 55,000 (16.1 kw) 55,000 (16.1 kw) Heat Exchanger Head Loss GPM Ft. of Hd. Loss 2 trace 5 0.4 8 2.3 10 4.6 12 6.9 Residential Laars Combi Heat DELUXE ENERGY SAVER MODELS NATURAL GAS AND LIQUID PROPANE GAS Model Number LCH-504T10FBN LCH-75T10BN Gal. 38 61 Capacity Input Recovery Recovery 90 F Rise 50 C Rise Gal. 45 72 Liters 170 272 65,000 76,000 61,000 76,000 Based on ANSI Z-21.10.1 and 10.3 and DOE Test Methods. Based on ANSI/ASHRAE 124 Standard. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change. kw 19.1 22.3 kw 17.9 22.3 70 81 59 70 66 81 55 70 Liters/ Hour 265 317 Liters/ Hour 250 317 Model Number LCH-504T10FBN LCH-75T10BN A Flue Conn. 59 1 /4 140 63 1 /4 153 22 26 B Jacket Diameter 56 66 C Vent Dia. 4 4 10 10 D T&P Conn. 50 53 127 E Gas Conn. 13 16 33 41 F Exchanger Inlet 27 7 /8 30 7 /8 150 162 G Exchanger Outlet 50 53 150 162 H Top of Heater 56 3 /8 60 1 /4 143 162 J Top Water Conn. 57 61 1 /4 145 156 24 1 /2 28 1 /2 K Depth All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix BN to CX. *Based on manufacturers rated recovery efficiency. Meets or exceeds the insulating standards established under ASHRAE Standard 90.1b (current edition). 62 72 Approx. Shipping Weight Lbs. Kg. 238 328 108 149 All natural gas models meet SCAQMD Requirements. Meets NAECA Requirements General: All gas water heaters are certified at 300 PSI test pressure (2068 kpa) and 150 PSI working pressure (1034 kpa). All potable water and heat exchanger connections are 3 4" NPT (19mm) on 11" (203mm) centers. All gas connections 1 2" (13mm). All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and or 10.3 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.

LAARS COMBI HEAT PV WATER HEATERS Laars Heating Systems Combi Heat PV (power-vented) water heaters also feature a glass-coated, double-wall heat exchanger coil. These combination water and space heating products provide home space heating and potable hot water from a single energy-saving source. The Laars Combi Heat PV models are available in capacities of 50 and 75-gallons. The 50-gallon model comes equipped with an extremely safe, reliable and maintenance-free Flammable Vapor Ignition System. The Laars Combi Heat PV FVIR Flammable Ignition Resistant Models Feature (50 gallon model, only): Advanced Flame Arrestor Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. Flammable Vapor Sensor Electronic sensor prevents burner operation if flammable vapors are detected. The sensor will also prevent operation if there is ongoing flammable vapor burn inside the combustion chamber. Maintenance Free Regular cleaning of air inlet openings or flame arrestor is not required under normal conditions. Sight Window Offers a view of the pilot and burner operation. Pedestal Base Rugged and durable base allows easy transport and positioning, and provides corrosion resistant contact with floor. Stainless Steel Flue Baffle Designed to maximize the amount of heat absorbed in the lower portion of tank. All Laars Combi Heat PV Models Feature Horizontal and Vertical Venting With 3" or 4" PVC, ABS OR CPVC (maximum equivalent vent length on reverse side). Powerful Blower Motor Our design has higher torque for greater resistance to outside winds and the power to eliminate problems with difficult venting situations. This significantly quieter motor runs cooler for a considerably longer operational life. Heat Exchanger Double wall 1 1 2" O.D. glass-coated steel coil ensures separation of potable water and heating fluid. Low Heat Exchanger Head Loss Up to 10 GPM flow, with less than 5 ft. of head loss. Greatly reduces the required pump size for heat exchange. Spark to Pilot Ignition System Eliminates the constant burning pilot used on other water heaters. Electronic Gas Control Valve The integrated, immersion gas control valve offers more precise temperature control for higher first hour delivery and also allows water temperature adjustment without removing the cover. The control is equipped with an LED display to aid in start-up and diagnostics. Glass Lined Tank Laars Heating Systems water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. Steel Tank Heavy gauge steel automatically formed, rolled and welded to assure a continuous seam for glass lining. Thermostatic Mixing Valve Supplied to help prevent injury due to scalding. Protective Aluminum Anode Rod Provides added protection against corrosion for long trouble-free service. Factory Installed Sediment Reduction System Cold water inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up at top of tank. Water Connections 3 4" NPT factory installed true dielectric fittings. 2" Non-CFC Foam Insulation Covers the sides and top of tank to save energy by retarding loss of heat. Also increases jacket rigidity. T&P Relief Valve Installed. Brass Drain Valve. Design Certified by CSA International (formerly AGA/CGA).

LAARS COMBI HEAT PV WATER HEATERS C A D & G K J H F B E Note: LCH-TW75 will not have a pedestal base LCH-TW50T10 LCH-TW75T10 Model Number FBN FCX BN CX Water Heating FHD 105 98 133 CA EF Space Heating CA AFUE % Max. Heating Capacity.65.65.64.64 82.0 82.0 82.0 82.0 55,000 (16.1 kw) 55,000 (16.1 kw) Heat Exchanger Head Loss GPM Ft. of Hd. Loss 2 trace 5 0.4 8 2.3 10 4.6 12 6.9 Residential Laars Combi Heat PV DELUXE ENERGY SAVER MODELS NATURAL GAS AND LIQUID PROPANE GAS Model Number LCH-TW50T10FBN LCH-TW75T10BN Gal. 38 61 Capacity Input Recovery Recovery 90 F Rise 50 C Rise Gal. 45 72 Liters 170 272 67,000 76,000 Based on ANSI Z-21.10.1 and 10.3 and DOE Test Methods. Based on ANSI/ASHRAE 124 Standard. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change. 60,000 75,500 kw 19.6 22.3 kw 17.5 22.1 72 82 60 69 LCH-TW50 LCH-TW75 Max. Equivalent Length Min. Equivalent Length Number 1 of 2 90 Elbows 3 65 81 54 67 3" Vent Pipe 60 ft. 7 ft. 55 ft. 50 ft. 45 ft. Liters/ Hour 272 310 4" Vent Pipe 180 ft. 15 ft. 175 ft. 170 ft. 165 ft. For high altitude installations, consult the installation instructions. Liters/ Hour 246 306 A B C D E F G H J K Model Number LCH-TW50T10FBN LCH-TW75T10BN Vent Conn. 65 7 /8 167 69 3 /4 177 Jacket Diameter 22 26 56 66 Vent Dia. 3 3 8 8 T&P Conn. 50 1 /8 53 127 Gas Conn. 11 3 /4 15 30 39 Exchanger Inlet 28 30 7 /8 71 78 Exchanger Outlet 50 1 /8 53 127 155 Top Top of Heater Water Conn. 56 3 /8 60 1 /4 143 153 57 3 /4 61 1 /2 147 156 Depth 26 3 /4 68 31 79 Approx. Shipping Weight Lbs. Kg. 245 335 111 152 All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix BN to CX. *Based on manufacturers rated recovery efficiency. Meets or exceeds the insulating standards established under ASHRAE Standard 90.1b (current edition). All natural gas models meet SCAQMD Requirements. Meets NAECA Requirements General: All gas water heaters are certified at 300 PSI test pressure (2068 kpa) and 150 PSI working pressure (1034 kpa). All potable water and heat exchanger connections are 3 4" NPT (19mm) on 11" (203mm) centers. All gas connections 1 2" (13mm). All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and or 10.3 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.

20 Industrial Way, Rochester, NH 03867 603.335.6300 FAX 603.335.3355 (Headquarters) 5 Kuehner Drive, Simi Valley, CA 93063 800.900.9276 FAX 800.559.1583 (Sales, Service) 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 905.238.0100 FAX 905.366.0130 www.laars.com Litho in A. Laars Heating Systems Co. 0704 Document 11025