TGA-IR Analysis Using the OMNIC Mercury TGA Software

Similar documents
Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Introduction to Fourier Transform Infrared Spectrometry

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

FT-IR Microspectroscopy in Forensic and Crime Lab Analysis

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Thermo Scientific SIEVE Software for Differential Expression Analysis

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

LIFECYCLE. Thermo Scientific. Enterprise Solutions

FT-NIR for Online Analysis in Polyol Production

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Pesticide Analysis by Mass Spectrometry

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

INTRODUCTION. The principles of which are to:

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Characterization of Polymers Using TGA

Updating the QIAcube operating software

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Guidance for Industry

Image Lab Software for the GS-900 Densitometer

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Thermo Scientific ExactFinder Software

INFRARED SPECTROSCOPY (IR)

Generating Heat. Part 1: Breathing Earth. Part 2: The Growth of Carbon Emitters. Introduction: Materials:

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

How To Control A Record System

Bridging the analytical gap

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Molecular Spectroscopy

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Gas Chromatography Liner Selection Guide

Mass Frontier 7.0 Quick Start Guide

FTIR Instrumentation

Background Information

Agilent Automotive Power Window Regulator Testing. Application Note

A Complete Solution for Method Linearity in HPLC and UHPLC

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Thermo Scientific ConFlo IV Universal Interface

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Agilent Television Power Consumption Testing. Application Note

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

The photoionization detector (PID) utilizes ultraviolet

Features Rich Detectors for Every Laboratory and Application

Wireless network traffic worldwide: forecasts and analysis

Telephone: (U.S.A.) or (worldwide) Fax: (worldwide) techsupport.analyze@thermo.

Analyze IQ Spectra Manager Version 1.2

Waves: Recording Sound Waves and Sound Wave Interference (Teacher s Guide)

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Setting up a Quantitative Analysis MS ChemStation

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Analysis of Liquid Samples on the Agilent GC-MS

ForensicDB: A Web-accessible Spectral Database

Getting Answers at the Source Requires a New Way of Thinking About Software

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

COMPLEXITY RISING: FROM HUMAN BEINGS TO HUMAN CIVILIZATION, A COMPLEXITY PROFILE. Y. Bar-Yam New England Complex Systems Institute, Cambridge, MA, USA

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Chapter 1: Chemistry: Measurements and Methods

Oxford University Chemistry Practical Course. X.3 Kinetics

IR READY TOGO. Spectrum Two FT-IR Spectroscopy

Testing Theories of Policy-Making: Educational Funding MICAH MCFADDEN

Annex 5A Trends in international carbon dioxide emissions

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Energy Efficiency Indicators for Public Electricity Production from Fossil Fuels

ENHANCING INTELLIGENCE SUCCESS: DATA CHARACTERIZATION Francine Forney, Senior Management Consultant, Fuel Consulting, LLC May 2013

Uses of Derivative Spectroscopy

[ Care and Use Manual ]

Flow Injection Analysis

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

ITS Training Class Charts and PivotTables Using Excel 2007

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

NFV and its Implications on Network Fault Management Abhinav Anand

QIAsymphony RGQ Protocol Sheet

White Paper. 10 Reasons to Choose Image-based Barcode Readers

Integrate, validate & implement. Human Identification Professional Services

In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Signal to Noise Instrumental Excel Assignment

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

Name Date Class STATES OF MATTER. SECTION 13.1 THE NATURE OF GASES (pages )

High-Speed Inter Connect (HSIC) Solution

The Limitations of Hand-held XRF Analyzers as a Quantitative Tool for Measuring Heavy Metal Pesticides on Art Objects. By Özge Gençay Üstün

Transcription:

TGA-IR Analysis Using the OMNIC Mercury TGA Software Michael S. Bradley, Ph.D., Thermo Fisher Scientific, Madison, WI, USA White Paper 52352 Key Words Nicolet is50, OMNIC Series, Mercury TGA, TGA-IR, Deformulation Abstract Procedures like failure analysis, process validation and competitive investigations often require that a sample be deformulated to identify components and to understand processing differences. TGA-IR provides tools for just this purpose. This White Paper describes the TGA-IR experiment and then focuses on the infrared data analysis, starting with manual tools and then describing the function of the Thermo Scientific OMNIC Mercury TGA software. This algorithm provides speed, thoroughness and consistency to the analysis while enabling any level of user to extract useful information from TGA-IR data sets. Introduction Operators working with materials like rubbers, plastics, resins, pharmaceuticals, adhesives and packaging need to understand differences between competitive products, causes of failures or the origin of odors or potentially toxic off-gassing. Standard analytical procedures are often incapable of distinguishing subtle differences like the presence of low-concentration additives or contaminants. Further, the same components may be present in two different materials, but the process used to make the products such as the processing temperature may vary, causing the interactions between components in the material to differ. This can lead to poor performance, such as early material fatigue or complete material failure. A complete analysis requires these materials to be deformulated essentially torn apart to expose their underlying nature. Thermal Gravimetric Analysis (TGA) is a common tool for doing this. A temperature ramp is applied to the sample and the breakdown tracked through weight loss as components vaporize. While providing quantitative information through weight loss, this process does not give insights into the chemical identity of the off-gassing materials.

In TGA-IR, the off-gassing materials are directed through a transfer line to a gas cell, where the infrared light interacts with the gases. The spectra can be used to identify the materials. The output of such an experiment is shown in Figure 1, from the analysis of a wood sample. At the top are the temperature ramp and first derivative weight loss information from the TGA and a Gram-Schmidt (GS) profile; the GS profile essentially shows the total change in the IR signal relative to the initial state (similar to a chromatogram). The bottom pane contains the spectrum collected at the time indicated. In most cases, the GS and the derivative weight loss will be similar in shape, although the intensity of the two can differ. The next step involves the extraction of useful information from this data set. main target. However, the profile conveys considerable information about how the material was produced. For instance, a shift of 30 C in the evolution temperature for a component in a carbon black rubber may relate directly to the thermal robustness of that rubber and hence to the lifetime expectation when used in tire manufacture. There are three complications: First, the quantity of spectra makes a complete manual analysis impractical, so the analyst is forced to select time regions to analyze. Second, the selection of those regions inherently risks missing information, which may or may not be critical to the analysis. Third, and most perplexing, much of the time multiple gases are being evolved simultaneously. This means the resulting spectra are complex, intertwined combinations, not single components. The need for skilled analysts to perform this task, who can ensure both completeness and correctness of the results, has led to an underutilization of this important tool. The OMNIC Mercury TGA software surmounts all three of the complications, giving fast, consistent and thorough results to operators of any skill level. The following discussion begins with simple cases and manual analysis and then shows the tremendous power of the Mercury TGA tool. Figure 1: TGA-IR results for wood sample. The top section includes the temperature ramp and the first derivative of the weight loss (from the TGA), along with the Gram-Schmidt profile for the FT-IR data. The bottom is a spectrum at a single time point. The inset shows the 3-dimensional nature of the data. Data Analysis: Information Overload The FT-IR data set from the TGA-IR experiment is three dimensional frequency versus intensity (the spectrum) versus time which is clearly evident in the 3D View inset to Figure 1. To get an estimate of the size of the data file, consider that a typical TGA experiment ramps at 15 C/minute from ambient to 900 C then holds at 900 C for 2 minutes. This results in a run time of approximately one hour. In parallel, the typical FT-IR experiment collects 4 scans at 4 wavenumber resolution, resulting in one spectrum being collected about every 5 seconds. For a one hour run, this could result in around 720 spectra being acquired. Manual analysis of all these spectra would be overwhelming and highly inefficient. There are two critical pieces of information desired from the FT-IR data: the identity of the off-gassing materials and the time dependence of the gas evolution (called the profile) for each component. The former identifies what comes off the sample; the latter tracks when the component is released. Most of the time, what is it? is the Getting Started: Basic TGA-IR Profiles Calcium oxalate monohydrate is a standard TGA test sample, which shows three relatively sharp TGA weight losses and, in parallel, three peaks in the Gram-Schmidt profile. Figure 2 shows GS and FT-IR data focusing on just the first two emission peaks. Using the cursor tool, a spectrum within the first peak of the GS profile has been selected (note the crosshair in the upper pane). The spectrum is easily identified as being water vapor due to dehydration (note even here these is a small amount of CO 2 ). The third GS peak is also pure, showing carbon dioxide evolution. Very few materials emit pure gases; much more common are mixtures such as seen in the second GS peak, shown in the inset (CO and CO 2 ). Figure 2: TGA-IR analysis (first two peaks) of Calcium Oxalate Monohydrate. The first peak is water; the second peak (inset) shows both CO and CO 2.

The user has three options to analyze the data shown in Figure 2 (remember, peaks 1 and 3 of the GS are pure while peak 2 is a mixture): Classic workflow: Select time points in peaks 1 or 3 and search. Select a time point in 2, search, subtract the top hit, search again or select spectra regions and selectively search. Multi-component enhanced workflow: Select time points in peaks 1 or 3 and search. Select a time point in 2 and perform a multi-component search, as discussed in the next session. Fully automated workflow: Click on Mercury TGA. The first process is highly manual and requires a skilled user. The second option removes much of the guesswork from the searching of mixture spectra, but still requires time region selection. The third option, as we will show, provides a complete, thorough analysis for any skill level of user. Multi-component Analysis at One Time Point Figure 3 shows a data from a TGA-IR experiment on an epoxy. The spectrum at the bottom appears to be quite complex. However, this is where a major benefit of gas phase spectroscopy comes to the forefront: most gases interact weakly or not at all. This means the mixed gas spectrum is essentially a simple co-addition of the component spectra. Figure 4: Multi-component search result from the OMNIC Specta software. The algorithm has identified four components and is showing the correlation between the actual spectrum and the synthetic spectrum consisting of the four components in appropriate percentages. Complete Analysis: Mercury TGA Ultimately, the process of analyzing narrow time regions even with OMNIC Specta leaves the task unfinished. The ultimate requirements for TGA-IR data analysis are as follows: Identify most or all of the components in the gases evolved from the TGA Use all spectra collected, not just a narrow time region Compute the time evolution of all species identified Visually ensure the results that are meaningful Get consistent answers, regardless of the user Compile the results in a complete report The TGA-IR data from a wood sample, shown in Figure 1, will be used to show the results of the Mercury TGA software. Figure 3: TGA-IR for an epoxy. The spectrum (lower window) shows the typical highly overlapped spectrum for the selected time point. The Thermo Scientific OMNIC Specta software was designed to enable simple and efficient multi-component searching. For single point TGA gas analysis, OMNIC Specta software provides results such as shown in Figure 4. This similarity between the multi-component search result and the original spectrum is striking, even though four components have been found. However, this provides an analysis at only one point or one narrow region. The dialog shown in Figure 5 is used to set up Mercury TGA. The search library is chosen first. Next, an estimate for the number of components present is entered; Mercury TGA provides a tool to estimate this input value. The maximum allowed is eight components. A region selection tool is also present to allow selection of a spectral range to analyze. Figure 5: Set up screen for Mercury TGA. All that is required is for the user to select the library and the number of components. Pressing the Compute button initiates the estimation routine for number of components.

Figure 6: The Mercury TGA result for the wood sample originally shown in Figure 1. See the text for explanation of the various panes of information. Pressing TGA Identify then starts the analysis. The speed of the calculation depends upon the number of data points, number of components, the library selection (bigger or multiple library selections means longer analysis time) and the speed of the computer. The 5-component analysis shown in Figure 6 involved processing 450 spectra in the Series file using the 460 spectra in the High Resolution Nicolet TGA Vapor Phase library. The process took less than 20 seconds. The upper left corner of the display shows the GS Profile. Below that are the calculated time profiles for each of the gases determined to have evolved. Note how the gases evolve at different times during the deformulation, with a complex pattern of overlapping profiles. To the right of the profiles are the spectra of the identified gases from the library. The table at the bottom provides text information about the search results. The last profile and spectrum, labeled Unknown, show what is essentially a residual of the analysis the spectral components of the overall run for which the algorithm has not yet accounted. In this case, the Unknown profile is mostly noise, indicating that the majority of the spectral features are assigned. The upper right window is critical to the user experience. This shows the composite spectrum (in red) created from the library spectra of the identified species compared to the collected spectrum (in blue) at a particular time point. Note this does not include the Unknown component, so it represents the analytical results only. Scrolling the bar in the Gram-Schmidt pane (upper left) allows the user to compare each spectrum in the Series file to the calculated composite at that time essentially playing back the synthetic and actual Series files simultaneously. This display is critical to determining if the algorithm has identified all of the critical components in the file more will be said of this below. As can be seen, with this set of result panes, Mercury TGA has fulfilled the requirements outlined above. The number of components selected and the choice of spectral library are the only variables. The Thermo Scientific Nicolet Vapor Phase Library containing over 8,500 spectra, serves as an excellent basis for analysis. User libraries based on proprietary or product-specific materials can also be constructed and searched simultaneously with the commercial library. Choosing the Number of Components Mercury TGA has three inputs the OMNIC Series data file, the choice of libraries and selection for the number of components. Several high quality vapor phase libraries are available and the user can create libraries specific to their application. Mercury TGA assists with the selection of number of components in two ways. The first, mentioned above, involves an approximation tool used during setup. This performs a quick overview of the data set and estimates the number of factors needed to describe the data. Typically, this algorithm is conservative, underestimating the actual number. However, it provides a starting point for the analysis.

Figure 7: TGA-IR results for a polymer resin analyzed by Mercury TGA using only three components. The comparison in the upper right pane of the synthetic (red) and actual (blue) spectrum shows that several components have been missed. The second tool involves visual review of the results combined with an Add One button. This allows the user to add another component (up to eight may be chosen) and restart the algorithm. The main driver for adding one is the composite versus actual screen in the upper right. This is best shown in an example. Figure 7 shows the Mercury TGA result for a polymer resin. The analysis was started with three components (which was chosen by the estimation tool), so four hits appear (three plus the unknown). Scrolling across the profile revealed a poor agreement of the composite with the actual data, as seen in the upper right box. Figure 8 shows the effect of pressing the Add One button repeatedly until six components were selected. The comparison is very good (only the profiles and identities are shown here for clarity). Isocyanic acid/ethyl isocyanate are very similar and have the same profile, so it is likely this is one component, not two. Since the library spectra and the actual data may be collected under different conditions, some intensity variations in the composite versus actual are to be expected, but the peaks should all be accounted for, as in this case. Since iteration took less than a minute, this visually driven process of refinement is not onerous or complex. Figure 8: Same data as in Figure 7, with the number of components being set to 4 (top), 5 (middle) and 6 (bottom). See text for details.

TGA-IR, Mercury TGA and Kinetics The first step in a TGA-IR analysis is to ensure good quality data. While many options exist, typical collection parameters (with the DLaTGS detector) are 4 cm -1 resolution, 0.4747 mirror velocity and co-adding 4 scans for each spectrum in a purged system. Most spectral libraries search well against 4 cm -1 data. These conditions give about a 5 second data collection time and good signal-to-noise. Faster collection is rarely needed as the gas evolution in the TGA during a slow temperature ramp does not rapidly change. As water and carbon dioxide are very common in TGA-IR, a purge is highly recommended. During the analysis, the actual versus composite spectra in the upper right of the Mercury TGA output provides visual confirmation of the results. This is far more exacting than the numerical metric: poor metrics can result even when the analysis is correct, due to the complexity of the analysis and the huge number of spectra being modeled. Further, inclusion of user libraries containing TGA-IR spectra from proprietary materials can substantially improve the results. A very exciting extension of the Mercury TGA algorithm involves the analysis of data from kinetics experiments. In kinetics, the Series file is an overlapped set of spectra from starting reagents, intermediates and products, plus solvents. Mathematically, this is exactly the same situation as the TGA-IR file. The profiles from analysis of a reaction (materials were proprietary so only profiles are shown) are shown in Figure 9 the evidence of reactants disappearing and product forming is clear, even to the level of a bound and released agent. Figure 9: Profiles showing evolution of reactants and products during a kinetics experiment, as extracted by the Mercury TGA algorithm. Conclusion TGA-IR is a very powerful analytical procedure for deformulation of rubbers, plastics and many types of compounded materials. The traditional roadblocks have been the large number of spectra generated and the over-lapped gas phase evolutions, leading to the need for some skill in the analysis. The OMNIC Mercury TGA algorithm completely overcomes the barriers, making TGA-IR a tool which can be used at any level of expertise. Further, complex, interwoven data sets like those in TGA-IR or kinetics previously required manual selections and analysis of single spectra (or co-added spectra) one-by-one, an inefficient and time consuming process. Mercury TGA software analyzes hundreds of spectra against large libraries, providing the multicomponent information efficiently, often in less than one minute. Now users at any skill level and working in any market can apply TGA-IR to their deformulation problems, confidently and consistently. White Paper 52352 www.thermoscientific.com 2012 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +27 11 822 4120 Australia +61 3 9757 4300 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 WP52352_E 07/12M Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland/Norway/Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS +43 1 333 50 34 0 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752