ADJ1000 Smart Skimmer and 5000ES Programmable Controller 8 Skimmers Operations Manual

Similar documents
Line to Refrigerator Ice/Water Dispenser

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTANT HOT WATER RECIRCULATING SYSTEM

Thermo Top - Troubleshooting Tree

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Advantium 2 Plus Alarm

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

INSTALLATION MANUAL MODEL RP-100

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

SETTING UP YOUR 6000 SERIES TIME RECORDER

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Water Tec of Tucson Water Systems

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

430 Power/Electronics Replacement

ROUGHNECK II Pumpless Drain

Utility Distribution Systems

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

Technical Guide 08/15/14

Sport Ice Elektro 124

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

MAC FAUCETS. Owner s Manual. Models: FA444

Single Station Remote Alarm

INSTALLATION AND OPERATING INSTRUCTIONS

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Mobile Data Power Model: MDP-25

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Installation Guide 2010 BMW S1000RR Full Exhaust System

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Universal Wireless Effects Controller USER S GUIDE SA115

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

Oil and Coolant Circulating Heating System. Model - OCSM

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

with installation dynafact boost GAUGE this manual is for use with systems

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

MODEL # Introduction

Please also see 10 golden rules for correct Saniflo installation on

INSTALLATION MANUAL MODEL RP-150

Troubleshooting Guide for Jacks Down LED Lights

1998½-2007 Dodge Ram 5.9L Cummins

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

MCR1900 Media Converter 19-Slot Chassis

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

GenStore Archive Cabinet

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

PNEUMATIC PLANISHING HAMMER

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

INSTALLATION AND OPERATION MANUAL

Installation and Operation Guide PD4600 Series Converter Replacement

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Temperature, Humidity & Dew Point Chart Recorder

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Geyser-R Heat pump water heater Installation manual

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Global Water Instrumentation, Inc.

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Compressor Service & Maintenance Manual

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

CT-001, CT-001-Solar Owner s Manual

Keypad Locks User Guide

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

Digital Photo Picture Frame. Operation Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Wireless Indoor/ Outdoor Thermometer

INSTALLATION INSTRUCTIONS

DC400 Dispensing Cutoff System

VOYAGER 570G. 744A Sprayer Control

SELECTION, APPLICATION AND MAINTENANCE

Streaming Potential System (SPT1000, SPD1000)

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Model 349KLX Remote Display Digital Scale User Instructions

Transcription:

ADJ1000 Smart Skimmer and 5000ES Programmable Controller 8 Skimmers Operations Manual Caution: Read rules for safe operation and instructions carefully. 3 YEAR WARRANTY This product is warranted to the original purchaser to be free from defective materials and workmanship. Under this warranty the product will be repaired or replaced at our option, without charge for parts or labor. This warranty does not apply to the skimmer hydrophobic filter, air logic valve or diaphragm. The period of this warranty covers 3 years on parts and labor from date of original purchase. This warranty entitles the original purchaser to have the warranted parts and labor rendered at no cost for the period of the warranty described above when the instrument is carried or shipped, prepaid, to our factory, together with proof of purchase. Copyright 1997 REV 07/2010 X ITEC H Instruments, Inc. 06 Camino De Los Desmontes, Placitas, New Mexico 87043 Phone: 505-867-0008 Fax: 505-867-0212 Web site: www.xitechinc.com E-mail: xitechinc@xitechinc.com RULES FOR SAFE OPERATION 1. Please review carefully and abide by the maximum limits placed on each type of equipment. 2. Please follow standard electrical practices and safety precautions when installing AC or DC power to our products.

Page 1 Xitech Product Recovery System Xitech Product Recovery System Page 2 Product Recovery System Installation The system (Figure 1) relates to floating hydrocarbon recovery in wells four inches in diameter and larger. This system includes: an intrinsically safe ADJ1000 pneumatic Smart Skimmer (Figure 2) which removes only the product to a sheen down to 200 feet deep; and a programmable Controller Model 5000ES which operates up to 8 skimmers intermittently, records run time, and has a high level tank shutoff assembly. STEP 1. Mount programmable Controller Model 5000ES (Figure 3) in a vertical position near the air source, power source, and holding tank if possible. CAUTION: The Model 5000ES is NOT intrinsically safe. If this controller must operate in a CLASS I area, use the XITECH Model 2550ES CLASS I Controller instead. Air supply needs to be free of WATER and OIL to have minimum maintenance. STEP 2. Install holding tank shutoff assembly into holding tank ( a 2 standard pipe inlet will be required in the holding tank). The level of product in the holding tank can be set by raising or lowering the liquid level float switch rod. Wire the shutoff switch cable into the controller (Figure 3). NOTE: If additional signal cable is needed to position the holding tank assembly further away from the controller, use 18 gauge 2-conductor wire. STEP 3. Attach power line from the AC or DC power source to the controller (Figure 3). Turn on the controller power switch. If the red Product Tank Full light stays on, you have a problem with tank shutoff wiring. Turn off the power switch and re-check the tank shutoff wiring. If the light continues to stay on, call the factory. If you plan to operate this controller for a long period of time on a DC power source, we suggest you use a solar panel (see page 13 for installation) to maintain power in the battery. ADJ1000 Smart Skimmer and 5000ES Controller with Tank Shutoff Shutoff Product Tank Product Air Source AC/DC Power Source ADJ1000 Skimmer Product/Water Interface Figure 1 5000ES Controller Quick Connect Union Filter Union Exhaust Valve Exhaust

Page 3 Xitech Product Recovery System Xitech Product Recovery System Page 4 Air Logic Valve Diaphragm Hydrophobic Filter Exhaust Product Flow Product Air Supply Figure 2 E G P Air Logic Valve Adjustment Port STEP 4. Install 1/2 OD air supply tubing from the main air source to the INLET of the Controller. Do NOT apply air pressure YET. STEP 5. Install horizontal air supply lines to each well. Use 3/8 OD tubing for horizontal runs. CAUTION: Please keep dirt from getting into these lines! Attach a filter union onto the end of this line at the well vault. STEP 6. Install horizontal product return lines to each well. For INDIVID- UAL product return lines use 1/2 OD tubing for horizontal runs. For a COMMON product return line, use 3/4 OD hose for all horizontal runs. Attach a quick connect union onto the end of this line at the well vault. STEP 7. Position the skimmer and well cap on the ground near the well. NOTE: If the skimmer is over 60 feet deep, use a vented design skimmer. Cut a length of 3/8 OD air supply tubing to cover the distance from the top of the well down to water/product interface, plus 5 feet. Slide enough tubing through the well cap and attach the end of the tubing to the top of the skimmer tube fitting labeled G (Figure 2). If the product thickness is greater than 1 foot, position the skimmer s Black Reference Line on skimmer well screen 1 foot below top of product. If the product thickness is less than 1 foot, position the skimmer s Black Reference Line on skimmer well screen at the water/product interface. STEP 8. Cut a length of 1/2 OD product tubing same length as the air supply line. Install 1/2 OD product tubing through the well cap tube fitting labeled P (Figure 2). Slide enough tubing through the well cap and attach the end of the tubing to the top of the skimmer tube fitting labeled P. CAUTION: Do not kink the tubing. STEP 9. Cut another length of 3/8 OD air exhaust tubing same length as air supply line. Install 3/8 OD air exhaust tubing through the well cap tube fitting labeled E. Slide enough tubing through the well cap and attach the end of the tubing to the top of the skimmer tube fitting labeled E.

Page 5 Xitech Product Recovery System Xitech Product Recovery System Page 6 5000ES Controller STEP 10. Cut a length of safety rope same length as air supply line. Attach the safety rope from inside the well cap to the top of the skimmer head. The tubing will carry the weight of the skimmer. Rain Tight Housing Computer Display and Keypad STEP 11. Attach the 3/8 filter union onto the 3/8 air supply line coming out of the well cap. STEP 12. Attach the 1/2 product line coming from the well cap into the inlet of the quick connect union. STEP 13. Attach the exhaust check valve onto the end of the 3/8 air exhaust line coming out of the well cap. STEP 14. Set operating air supply pressure. Air Inlet AC Fuse (1 amp) DC Fuse (2 amp, resettable) AC Line White: Neutral Black: Hot Green: Ground 12V DC Line Red: + Black: - Figure 3 Holding Tank Switch Cable Power Switch Tank Full Indicator Junction Box AIR PRESSURE = 35 + Total Vertical Lift 2.85 Minimum operating pressure is 35 PSI Maximum operating pressure is 125 PSI STEP 15. Manual operation of skimmer. Go to the Manual Control Window within the DIRECT MODE program (refer to pages 7-12 for instructions). Turn on station #1. Observe that the skimmer is making a pumping noise. The exhaust check valve should have an intermittent pulsing sound about once every second. STEP 16. While the skimmer is running at the desired operating air pressure above ground, confirm or adjust skimmer pulse rate. To adjust skimmer pulse rate, remove small plug at the top of the skimmer pump head and insert a small flat-head screwdriver into the air logic valve located inside the pump head. Turn clockwise to decrease pulse rate. NOTE: Factory sets skimmer pulse rate to 60 pulses per minute at 50 psi operating pressure. Maximum recommended pulse rate is 80 pulses per minute. Lower pulse rates will consume less air.

Page 7 Xitech Product Recovery System Xitech Product Recovery System Page 8 STEP 17. You are now ready to install skimmer in the well. CAUTION: Please remove skimmer float shipping tie wraps before placing skimmer in well. Perform STEPS 15 & 16 for each additional skimmer. Explanation of the 5000ES Software Windows SET UP MODE: This is were you set the actual time and date for the computer. DIRECT MODE: This is were you program each of the 8 outlet stations. STATUS WINDOW: This is the first window in the Direct Mode. Here you can observe the state of each of the 8 outlet stations and the elapsed run of each outlet station. This window is also where you can reset the elapsed time of any station. PROGRAM WINDOW #1: This is the second window in the Direct Mode. This is where you program each station s START DATE, START TIME, and DURATION or pump run time. PROGRAM WINDOW #2: This is the third window in the Direct Mode. This is where you program each station s CYCLES per day, PERIODS or days delay between run times, and LEVEL SENSOR test mode. CAUTION: When the Level Sensor is OFF the 5000ES will NOT look for a High Product Tank signal. MANUAL CONTROL WINDOW: This is the fourth window in the Direct Mode. This window is used to temporary override any of the 8 stations present states. The P means that the manual control will be overridden by the program. The M means manual control only. OFF means that this station is not running. ON means this station will stay running until you leave this window. Operation of the Product Recovery System Determine how long it takes for each skimmer to remove all product from the well by using the Manual Control Mode Window. If your skimmer is less than 30 feet deep, product should show up above ground in about 2 minutes. Observe the product being discharged by the skimmer. Be sure no water is being pumped. If water does appear, pull the skimmer out of the well and check to see if the shipping tie wraps have been removed from the skimmer well screen area. If there are no tie wraps, give Xitech a call toll free at 888-867-9483. Record the amount of time it takes to empty the well of product. When the well is empty of product, turn off the skimmer. If you found it took 10 minutes to pump the product off, set the pumping time to 5 minutes (Xitech s 1/2 Rule). You now have to guess how many times a day to empty the well. A good guess would be once a day for slow recovering product and 3-6 times a day for fast recovering product. For ease of system observation we suggest that you run only one well at a time and that you have the nearest well run first, the next nearest well run next and so on. PLEASE CALL XITECH FROM THE FIELD IF YOU HAVE ANY TROUBLE WITH YOUR INSTALLATION. FINAL NOTE: Keep in mind that you are trying to empty the formation of free product over a long period of time. To do this, you must always try to keep some free product thickness in your recovery well at all time while removing free product daily.

Page 9 Xitech Product Recovery System Xitech Product Recovery System Page 10 To Set Up The Program STEP 1. Press the DEL key to reset the computer. You will end up at the SET UP MODE window. STEP 2. Press the MENU KEY one time to move to the SET TIME window. Press the right or left arrow keys to move from field to field. Press the up or down arrow keys to change the values. STEP 3. Press the menu key to move to the DATE window. Press the right or left arrow keys to move from field to field. Press the up or down arrow keys to change the values. STEP 4. Press the DEL key one time. STEP 5. Press the UP arrow key one time to get to the DIRECT MODE. STEP 6. Press the MENU key one time to get to the status window. STEP 7. Clear the elapsed run times for all stations by pressing the TIME RESET button at every station. VERY IMPORTANT! STEP 8. Press the MENU key two times to get to the 1st programming window. You should see station #, date, time, and duration in this window. STEP 9. Enter the start date, start time, and duration (NOTE: If you found it took 10 minutes to pump the product off, set the pumping time to 5 minutes (Xitech s 1/2 Rule)) for all stations that have a skimmer. SUGGESTION: Choose start times that do not overlap. DATE: MM-DD-YY TIME: HH:MM DURATION: HH:MM STEP 10. Press the MENU key one time to move to the last programming window. You should be at the CYCLES/PERIODS window. STEP 11. Enter the number of times a day you want each skimmer to operate. EXAMPLE: If you would like the skimmer to run every eight hours, you would enter 03 Cycles (three times a day). If you would like the skimmer to run every other day. You would move the curser under the C in Cycles, press the UP arrow key one time, and enter 02 Periods. You must first set Cycles to 00 before changing to Periods. NOTE: A good guess would be once a day for slow recovering product and 3-6 times a day for fast recovering product. NOTE: Keep in mind that you are always trying to match the recovery rate of product coming into the well from the formation. It is not good practice to operate skimmers faster than the formation recovery rate. NOTE: The LEVEL should always be on if you are pumping to a holding tank. STEP 12. Press the MENU KEY three times to get back to the STA- TUS window. You should see the word ACTIVE for all stations that have a program and the word INACTIVE for all stations that do not have a program. If you see the word INACTIVE on a station that you created a program for, then you have left something out in the programming. Try again or call Xitech for assistance, toll free at 888-867-9483. NOTE: You always want to be in the STATUS window when you leave the site. Status Window Conditions: INACTIVE Station inactive or OFF ACTIVE Station has program but not running RUNNING Station active, elapsed time started HIGH TANK Stations are turned OFF

Page 11 Xitech Product Recovery System Xitech Product Recovery System Page 12 Computer Data Windows For The SET UP & DIRECT Modes SET UP MODE: System Time and Date 1. Mode Selection Window CONTROL MODE SETUP 2. Set Current Time Window SET TIME: HH:MM:SS USE 24 HOUR TIME 3. Set Current Date Window SET DATE: MM-DD-YY DIRECT MODE: Stations Set Up, Level Sensor, and Manual Control 1. Mode Selection Window CONTROL MODE DIRECT 2. Station Status Window STATION 1 INACTIVE TOTAL TIME = 00000:00 3. Station Set Up Window 1 START MM-DD-YY HH:MM DURATION HH:MM 4. Station Cycles & Level Sensor Window 1 CYCLES 00 (00-99) LEVEL SENSOR ON 5. Station Manual Control Window 1 STATION P OFF Key Pad Descriptions MENU: This Key changes windows. The left & right Keys move the cursor to the next programmable field. : This Key increases the value in the field the cursor is on. : This Key decreases the value in the field the cursor is on. TIME RESET: This Key will reset the elapsed run time of a station when you are in the STATUS WINDOW. REV: This Key is to show you what software version is currently being used by your computer. DEL: This Key will replace all programmed values with preset default values. This Key will NOT delete the elapsed run time in the STATUS WINDOW.

Page 13 Xitech Product Recovery System Xitech Product Recovery System Page 14 Solar Panel Installation STEP 1. Attach solar panel to the solar panel bracket and then to pole above the controller. STEP 2. Disconnect controller power cord from battery. STEP 3. Remove the lower junction box plate from the controller. Take the solar panel cable and insert through opening in bottom of the controller junction box. Attach red wires from the solar panel cable, battery cable, and the controller together. Attach black wires from the solar panel cable, battery cable, and the controller together. STEP 4. Attach the red power cable battery clip to the positive terminal on the battery and the black power cable battery clip to the negative terminal on the battery. Removing The Skimmer Assembly From The Pump 1. Remove the two bolts that secure the skimming housing to the pump. Remove the lower tubing strap at the bottom of the skimmer. 2. Separate the skimming housing from the pump by feeding the black product tubing that runs along the outside of the well screen up into the well screen. 3. Loosen the tubing fitting to free the product tubing from the fitting. Solar Panel Controller Black Red Red + - Battery Black

Page 15 Xitech Product Recovery System Xitech Product Recovery System Page 16 Replacing The Skimmer Filter 1. Remove the stop bolt at the bottom of the well screen housing. 2. Remove the skimming assembly from the well screen housing. 3. Remove the skimming filter from the float assembly. No tools required. 4. Push on a new skimming filter onto the float assembly and return skimming assembly to the well screen housing. 5. Secure the stop bolt to the well screen housing. Replacing The Skimmer Diaphragm 1. Loosen all bolts until bottom can be detached. Do not separate pump head, valve housing or diaphragm from the six bolts at this time. 2. Lay pump on its side on the table and remove the diaphragm from all six bolts. 3. Place new diaphragm onto the six bolts and reattach upper pump parts with the pump bottom. Pump Head Well Screen Housing Skimming Filter Float Assembly Valve Housing Diaphragm Pump Bottom Stop Bolt

XITECH MODEL 5000ES CONTROLLER MOUNTING 1.00" 10.00" 9/32" Diameter 14.750" 0.375" 0.00 0.00 0.524" 1/2" NPT 0.700" C/L 0.700"