Lightweight aggregate concrete (LAC) Vertical coring reference bricks (Hlz) ÖNORM B 6124. Autoclaved aerated concrete P2 - P7



Similar documents
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

HUS-HR, CR Screw anchor, stainless steel

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

WATERPROOFING OF WET ROOMS

fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

12.1 Schlüter -KERDI-BOARD

BETONYP building boards. The modern way of living.

Rockwool Flexi Insulation Application Guide

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Discussion on Products under the Scope of EN and proposed CEN/TR to clarify the scope

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Composite Panel Firewall Systems

HORIZONTAL INSTALLATION

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

HVU with HAS/HAS-E rod adhesive anchor

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

European technical approval ETA-12/0208

HUS-HR, CR Screw anchor, stainless steel

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version


European Technical Approval ETA-12/0500

PC-Concrete Injectable Concrete Anchoring and Repair System

RPV - RP - RA air handling units

Scope of EN Clarification Document

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

Product Data Sheet ROCKPANEL Rockclad

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

ICC-ES Evaluation Report

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

How To Make An Oriented Strand Board

ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Saferand easierinstallation

European Technical Approval ETA-10/0200

PART E SPECIFICATIONS

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

Rockwool Cladding Roll

Hilti HIT-HY 200 with rebar

Removable Aluminium posts

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Detailing of Reinforcment in Concrete Structures

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Hanson Building Products. precast basement solutions

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Chapter 3 Pre-Installation, Foundations and Piers

Window Installation Instructions

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

Mandate M/116 MASONRY AND RELATED PRODUCTS

Pipe Clamps and Accessories

Operating Instructions

European Technical Assessment. ETA-02/0020 of 22 September English translation prepared by DIBt - Original version in German language

Material test chamber with mechanical convection

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

MERO Floor Systems - CleanRoom

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

MultiPost-AP anchorage device

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Solid shape molding is not desired in injection molding due to following reasons.

Sealing & Bonding Sika solutions for Window Installation

Flat Roofing Made Simple The EJOT Range includes:- Flat roofing fastening system for fixing thermal insulation and

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Fall Protection Solutions

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

AA Solar and Sun Power Plus

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

building applications copper - redefined

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

PART 1 GENERAL 1.1 SECTION INCLUDES

Hilti HIT-HY 150 MAX with rebar

Asphalt Shingle Application Requirements

High-performance, 2-part epoxy anchoring adhesive

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

How To Buy A Designo Grille

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Machine devices, jig devices

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Important Information

SikaProof A Technology

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Transcription:

Anchor table ejotherm anchors with European Technical Approval (ETA) Fasteners for insulation boards Rail systems ejotherm ejotherm ejotherm ejotherm ejotherm ejotherm STR U STR H NT U NTK U SDK U NK U page 16 page 17 page 20 page 21 page 24 page 25 Normal weight concrete C 12/15 acc. to EN 206-1 Normal weight concrete C 16/20 - C 50/60 EN 206-1 Clay bricks (Mz) acc. to DIN 105 Solid lime sandstone (KS) DIN EN 106 Solid masonry of lightweight concrete (V) DIN 18152 Vertically perforated clay bricks (Hlz) acc. to DIN 105 Sand-lime perforated bricks (KSL) DIN EN 106 Lightweight concrete hollow blocks (HbL) DIN 18151 Lightweight aggregate concrete (LAC) Vertical coring reference bricks (Hlz) ÖNORM B 6124 Autoclaved aerated concrete P2 - P7 Wooden substrates and metal sheets (without ETA) Fastening solutions for special applications with German DIBt approval Clinker systems Specialty solutions EJOT EJOT EJOT EJOT EJOT SDF S plus 8UB SDP S plus 8 SDM T plus 8/60U VSD WSS/KERI page 28 page 29 page 30 page 32 page 33 Normal weight concrete Clay bricks Solid lime sandstone Vertically perforated clay bricks Solid masonry or solid blocks of lightweight concrete Sand-lime perforated bricks Lightweight concrete hollow blocks Weather panels of three layer facade envelope (concrete) Lightweight aggregate concrete Autoclaved aerated concrete acc. to DIN Autoclaved aerated concrete acc. to TGL Application ruled in the approval Proof of qualification through tests on the building no approval

Imprint Publisher: EJOT Baubefestigungen GmbH 57334 Bad Laasphe Germany Layout and execution: conception Werbung & Marketing GmbH, 57072 Siegen EJOT Baubefestigungen GmbH Photos: Title and Underground garage, Niels Otto Bricklayer, Birgid Allig/zefa/Corbis Freiherr-vom-Stein-Gymnasium, Münster, Christian Richters Fotografie Schlossarkaden Braunschweig, ECE Products, Theissen Fotodesign Print: Schlabach GmbH & Co. KG, D 57339 Erndtebrück Legal notes: Our latest sales terms and delivery conditions apply. EJOT products are constantly enhanced. They are subject to technical changes, assortment and price changes. During planning and use of our products please comply with accepted engineering rules, planning laws as well as relevant safety regulations. The national technical approvals granted to our products can be downloaded on the internet at www.ejot.com. by EJOT Baubefestigungen GmbH EJOT is a registered trademark of EJOT GmbH & Co. KG. ejotherm is a registered trademark of EJOT Baubefestigungen GmbH. TORX is a registered trademark of Camcar, Div. of Textron, Rockford, IL.

Content 4 Your strong partner 6 ETICS experience 12 References 13 The ejotherm generation 14 The EJOT STR principle 15 ejotherm plate anchors 16 ejotherm STR U Cap anchor for concrete and masonry 17 ejotherm STR H Cap anchor for wood and metal sheets 18 ejotherm STR accessories 20 ejotherm NT U Universal hammer-in anchor 21 ejotherm NTK U Telescope anchor 22 EJOT additional plates 23 ejotherm anchors for rail fastenings 24 ejotherm SDK U Screw-in anchor for rails 25 ejotherm NK U Hammer-in anchor for rails 26 Accessories for rail fastenings 27 EJOT anchors for clinker systems 28 EJOT SDF S plus 8UB Clinker system anchor for concrete and masonry 29 EJOT SDP S plus 8 Clinker system anchor for gas concrete 30 Solutions for special applications 30 EJOT SDM T plus 8/60U Specialist for problematic substrates 31 EJOT SDF K plus 8U Specialist for rail systems on problematic substrates 32 EJOT VSD Renovation anchor for prewall shells 33 EJOT WSS and Keri Renovation rods for weather shells 34 EJOT special drill for optimum loads in peforated bricks 34 EJOT spiral anchor for fastening of light attachments on ETICS facades 35 Fasteners for ceiling insulation 36 EJOT DDS and DDT Ceiling insulation screw with additional plate 37 EJOT DDA Ceiling insulation anchor 38 EJOT DMH and DMT Metal insulation support with additional plate 39 EJOT anchor basics 3

Your strong partner 4 5 1 3 2 EJOT Building Fasteners: Over 30 years of special knowledge around the building envelope b a 1 2 3 Industrial lightweight construction (ILB) High-quality fastener products for fixing profiled sheets and sandwich panels on industrial steel frame construction External Thermal Insulation Composite Systems (WDVS) Special anchors for fixing insulation on external wall systems a plate anchors for direct fastening of insulation boards on the facade b anchors for fastening of base and profile rails c specialty solutions for rebuilding stability d fastening solutions for ceiling insulations e specialty solutions and accessories Rear ventilated facades (VHF) Fasteners and anchors for fixing brackets to substrate, frame to brackets, insulation to substrate and facade fascias on rear ventilated systems c a 4 5 Flat roofing (FLD) Fasteners, stress plates and installation tools for the efficient attachment of insulation and waterproof membrane to deck Industrial Window and Facades Technique (IFF) Application specific fasteners for UPVC window and door manufacturing and aluminium/glass curtain wall systems 4

Your strong partner EJOT Your strong partner for fastening solutions in the building industry l Expertise and experience With over 30 years of experience and development know-how Made in Germany, we understand the requirements of a fastener and its application on building envelopes very precisely. Our knowledge is the base and source of our products and subsequent solutions which offer our customers real benefits. l Quality and easy installation The quality of our products surpasses planning laws and legal requirements. Our highest aim is to ensure quick and easy assembly. l Customer-friendly service We make a point of building trusting and friendly relationships with our customers. Our personal advisers offer 24-hour customer service. If required our employees deliver technical back-up on the building site. In addition we provide our knowhow through training seminars. l There for you worldwide Our Europe-wide sales and service network with over 25 subsidiaries as well as a worldwide project support team is pleased to help our customers at any time. 5

ETICS competency Your service Our quality: EJOT philosophy sets standards Are you absolutely sure what is behind the old rendering? ETICS are often used in renovation. The major part of the structural fabric is of bad quality or combined masonry was used. The bearing capacity of the old render is reduced through environmental stress. The ejotherm anchor generation provides safety. Especially the ejotherm STR U can be used in any substrate. As the first 8 mm ETICS anchor, it obtained a European Technical Approval for all building material categories. Despite shortest anchorage depths, it reaches the highest characteristic loads. With EJOT quality your service promise will not hang by a thread

ETICS competency I cannot afford a construction site to stagnate due to installation problems. And even worse are customer complaints. Today, everything has to be fast and smooth but without reduction of quality and security. EJOT anchors are great to work with. Especially the STR principle is simply ingenious. 100% setting control and homogeneous insulation surfaces thus I can still relax after many years. 7

ETICS competency Your system Our know-how: over 30 years of ETICS anchors by EJOT Through our close contact to practitioners and developers, we are able to develop ideal fastening solutions for today s and tomorrow s facade insulation systems. Make use of this head start for your system! And experience how decades of know-how reveal in easy and quick installation. Based on this practical experience, in special cases our experts work out individual solutions for you even right on the building site. Some examples of our service: l personal consultants - even on the building site l competent consulting via phone or e-mail l fast and reliable delivery service l anchor pull-out tests on site l trainings in fastening technology l support with bidding processes Your benefits: l custom-designed solutions you can rely on l our decades of know-how l planning security

ETICS competency As consultant of a system owner, I know the daily perfidies and annoyances that make life hard for users and cost them valuable time. With EJOT anchors, the right choice is easy. And I can rely on that they work even when the conditions at the object are not ideal.! EJOT anchors for ETICS are important components of high-grade facade systems. Like all other system components they are exclusively sold to system owners. 9

ETICS competency Your advantage Our programme: anchor choice made easy Which anchor do I need for which substrate? What do I do when faced with mixed masonry? Our ejotherm family with European Technical Approval (ETA) simplifies your choice. Powerful anchors provide for secure fastening in all substrates and with all kinds of insulation materials. Your benefits: l clear product range for all substrates l solutions for all insulation materials l easy anchor choice l reduced stock volume Moreover you have a special programme with cost-efficient special solutions at your hand. Typical applications are: l rebuilding the stability of damaged ETICS l solutions for renovating the renovation l re-establishing the stability of weather shells and prewall shells Use category A Use category B Use category C Use category D Use category E ejotherm STR U competitive product A competitive product B competitive product C Normal weight concrete Solid masonry Hollow or perforated masonry Lightweight aggregate concrete Autoclaved aerated concrete 10

ETICS competency To me as a planer, energy savings and the design of a new ETICS facade are most important. Moreover I am responsible that the facade is secure and immaculate even after years this is what the client expects. That is why we advertise ejotherm STR U. If necessary, EJOT experts already consult me during the bidding process even right on the building site. 11

References Freiherr-vom-Stein-Gymnasium, Munster EJOT The Quality Connection: international customers rely on EJOT During more than three decades, over 500,000,000 sqm of ETICS facades have been fastened with EJOT anchors without even a single incident! This equals an area of more than 70,000 football pitches. Roughly 150 billion liters of heating oil or 440 million tons of CO 2 have been saved a valuable contribution to the environment. And they get more by the day. More and more international customers and principals rely on sophisticated fastening solutions and the competent advice by EJOT. EJOT quality connects also internationally! Ginger & Fred, Prague Estate Blumlägerfeld, Celle Schloss-Arkaden Braunschweig Music Academy, Stuttgart 12

The ejotherm generation Up to 45 mm shorter anchor lengths Short and good quick and economic: performance up, costs down The new ejotherm generation makes it possible. Specially developed expansion zones enable highest characteristic loads with minimum anchorage depths. The result: quick installation and economic total cost. Your benefits: l up to 45 mm shorter anchor lengths *) l valuable safety reserves in doubtful substrates l economic anchor usage l universal expansion zones for maximum use range l universal drill diameter for all substrates (8 mm) *) in comparison with earlier EJOT anchors nominal anchorage depth h nom characteristic load ejotherm STR U ejotherm NT U competitive product A competitive product B cost installation time, anchor length, drill abrasion performance safety, number of anchors/m 2, sensitivity with varying substrate qualities Substrate: Vertically perforated clay bricks (Hlz) Source: specifications of the individual European Technical Approval (ETA) 13

The EJOT STR principle 1 2 3 4 Your guarantee Our STR principle For long-lasting beautiful facades With its STR principle, EJOT has developed a unique fastening system. Without any additional work, the anchor plates are installed countersunk and covered with an insulation cap. This creates a homogenous surface and an even rendering, and helps to avoid anchor marks. For all substrates The ejotherm STR U is the first 8 mm ETICS anchor with European approval for all building materials, including gas concrete (use categories A - E). For fastenings on wooden materials we provide ejotherm STR H. Both anchors are installed with the same ejotherm STR tool. Easy installation: 1 2 3 4 Quick drilling thanks to reduced drill depth Put anchor with pre-mounted screw into the hole until the plate bears on the surface Screw with the STR tool: countersinking happens automatically (no milling, no dust) Insert the STR insulation cap ready! For all insulation materials Both ejotherm STR U and ejotherm STR H can be either installed countersunk according to the STR principle or plain with the surface with the STR plug. This way an adaptation to all commonly used types of insulation is possible. Quality and safety in XXL The EJOT STR princple is available for insulation of up to 360 mm the perfect fastening system for zero- and lowenergy houses. 14

ejotherm plate anchors ejotherm plate anchors anchor choice made easy When fastening an ETICS, insulation boards are usually attached to the facade with adhesive and then fastened with anchors. The bearing load of the system is carried onto the facade via shearing forces. High-quality plate anchors installed through the insulation guarantee additional contact pressure through their stiff plates. This contact pressure supports the permanent frictional bonding between adhesive and substructure. Through a powerful anchoring in the wall and the contact pressure of the plate, the tension of the insulation releases ( screw clamp effect ). ejotherm plate anchors with European Technical Approval offer certified safety even under high wind loads. Through their plates and the expansion element, they redirect the tensile load into the bearing substructure. The plate anchors of the ejotherm generation make things easy for you: Easy anchor choice for safe anchoring in any building material. Together with a minimum anchor depth and maximum performance. Performance up, total cost down! For long-lasting, energy-saving facades. 15

ejotherm STR U Cap anchor for concrete and masonry l approved for all categories of building materials l the EJOT STR principle with STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust l also installable plain with the surface with STR plug l shortest anchorage depths, highest loads for maximum safety and economic anchor usage l permanent contact pressure l optimised thermal bridges l premounted screw for quick installation l 100% setting control: the countersunk installation of the plate signalises safe anchorage Technical data Installation Anchor diameter 8 mm Plate diameter 60 mm Drill hole depth, countersunk installation h 1 >_ 50 mm (90 mm) Drill hole depth, plain with the surface h 2 >_ 35 mm (75 mm) Anchorage depth h ef >_ 25 mm (65 mm) Use categories acc. to ETA A, B, C, D, E European Technical Approval ETA-04/0023 Values in parentheses: anchoring in gas concrete (use category E) Characteristic loads Normal weight concrete C 12/15 acc. to EN 206-1 1.5 kn Normal weight concrete C 16/20 - C 50/60 acc. EN 206-1 1.5 kn Clay bricks (Mz) acc. to DIN 105 1.5 kn Solid lime sandstone (KS) acc. to DIN EN 106 1.5 kn Solid masonry of lightweight concrete (V) acc. DIN 18152 0.6 kn Vertically perforated clay bricks (Hlz) acc. to DIN 105 1.2 kn Vertical coring reference bricks (Hlz) acc. ÖNORM B 6124 0.75 kn Sand-lime perforated bricks (KSL) acc. to DIN EN 106 1.5 kn Lightweight concrete hollow blocks (HbL) acc. DIN 18151 0.6 kn Lightweight aggregate concrete (LAC) 0.9 kn Autoclaved aerated concrete P2 - P7 0.75 kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Countersunk installation acc. STR principle with STR cap Installation plain with the surface with STR plug Product range Use category Use category Product name Use category Use category Product name A D E and A D E and Insulation (mm) Insulation (mm) length (mm) Insulation (mm) Insulation (mm) length (mm) New build. ¹) Renovation ²) New build. ¹) Renovation ²) New build. ¹) Renovation ²) New build. ¹) Renovation ²) 80 60 3) ejotherm STR U 115 240 220 200 180 ejotherm STR U 275 100 80 60 3) ejotherm STR U 135 260 240 220 180 ejotherm STR U 295 120 100 80 60 3) ejotherm STR U 155 280 260 240 200 ejotherm STR U 315 140 120 100 80 ejotherm STR U 175 300 280 260 240 ejotherm STR U 335 160 140 120 100 ejotherm STR U 195 320 300 280 260 ejotherm STR U 355 180 160 140 120 ejotherm STR U 215 340 320 300 280 ejotherm STR U 375 200 180 160 140 ejotherm STR U 235 360 340 320 300 ejotherm STR U 395 220 200 180 160 ejotherm STR U 255 Product code: 8709... 400 (e.g. ejotherm STR U 115: 8709 115 400). ¹ ) 10 mm adhesive ² ) 3) 10 mm adhesive and 20 mm old render to be installed plain with the surface only Note: Always use in combination with STR cap and STR plug respectively. Packaging: 100 pieces each. 16

ejotherm STR H Cap anchor for wood and metal sheets l for wooden substrates as well as metal sheets of up to 0.75 mm l the EJOT STR principle with STR cap for homogenous surfaces and even rendering - quick and easy without milling dust l also installable plain with the surface with STR plug l permanent contact pressure l 100% setting control: the countersunk installation of the plate signalises safe anchorage Installation Technical data Screw diameter Plate diameter Screw-in depth 6 mm 60 mm 30-40 mm Recommended use loads Wood fibreboards (thickness >_ 17,0 mm) Chipboards (thickness >_ 13,0 mm) Gypsum fibreboards (thickness >_ 12,5 mm) OSB plates (thickness >_ 16,0 mm) Solid wood plates (thickness >_ 27 mm) The recommended use loads are calculated with a safety factor of 3. They may differ according to the object. 0.25 kn 0.25 kn 0.15 kn 0.25 kn 0.25 kn Countersunk installation acc. STR principle with STR cap Installation plain with the surface with STR plug Product range Countersunk Installation plain Product name Product code installation with the surface and Insulation (mm) Insulation (mm) length (mm) ) 40 ejotherm STR H 080 8711 080 400 60 ejotherm STR H 100 8711 100 400 80 80 ejotherm STR H 120 8711 120 400 100 100 ejotherm STR H 140 8711 140 400 120 120 ejotherm STR H 160 8711 160 400 140 140 ejotherm STR H 180 8711 180 400 160 160 ejotherm STR H 200 8711 200 400 180 180 ejotherm STR H 220 8711 220 400 Note: Always use in combination with STR cap and STR plug respectively. Further lengths on request. Packaging: 100 pieces each. 17

ejotherm STR accessories ejotherm STR cap EPS l specially developed system cap of polystyrene (EPS) l to be used with ejotherm STR U and ejotherm STR H l colours: white or grey ejotherm STR cap MW l specially developed system cap of mineral wool l to be used with ejotherm STR U and ejotherm STR H ejotherm STR plug l sepcial plug of polystyrene (EPS) l to be used with ejotherm STR U when installed plain with the surface (included with ejotherm STR H) Product range Product name Product code Packaging (pieces/box) ejotherm STR cap EPS white 8593 000 093 100 ejotherm STR cap EPS grey 8593 111 070 100 ejotherm STR cap MW 8593 000 098 100 ejotherm STR plug 8709 033 000 500 18

ejotherm STR accessories ejotherm STR tool l specially developed tool for countersunk installation of ejotherm STR U and ejotherm STR H l sturdy construction for long durability l wear parts are exchanged quickly l set comprises: STR-tool, additional cutting metals, angle screw driver, bits for all applications ejotherm STR tool spare kit l to replace wear parts of the STR tool l set comprises: 3 cutting metals, 3 bits for countersunk installation ejotherm STR renovation cutter l for subsequently securing ETICS facades: cost-efficient re-establishment of the structural stability through subsequent anchoring l avoids the de-installation of the old system in many cases l utilisation of the EJOT STR technology: 1. mill the existent plaster layer, 2. install the ejotherm STR U, 3. insert the STR cap to obtain an even plaster base, 4. plaster a new final rendering Product range Product name Product code Packaging (pieces/box) ejotherm STR tool 9151 900 000 1 ejotherm STR tool spare kit 9151 910 000 1 ejotherm STR renovation cutter 9151 940 000 1 19

ejotherm NT U Universal hammer-in anchor l approved for concrete, solid and perforate masonry l solid steel nail (break-proof) l plastic injection moulding to reduce thermal bridges l installable with additional plate l shortest anchorage depths, minimum drill hole depth l high loads for your security l economic anchor usage l premounted nail for quick installation Technical data Installation Anchor diameter Plate diameter Drilll hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 60 mm 35 mm 25 mm A, B, C ETA-05/0009 Characteristic loads Normal weight concrete C 12/15 acc. to EN 206-1 1.2 kn Normal weight concrete C 16/20 - C 50/60 acc. EN 206-1 1.2 kn Clay bricks (Mz) acc. to DIN 105 1.5 kn Solid lime sandstone (KS) acc. to DIN EN 106 1.5 kn Solid masonry of lightweight concrete (V) acc. DIN 18152 0.5 kn Vertically perforated clay bricks (Hlz) acc. to DIN 105 0.9 kn Sand-lime perforated bricks (KSL) acc. to DIN EN 106 1.5 kn Lightweight concrete hollow blocks (HbL) acc. DIN 18151 0.5 kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Product range Insulation (mm) Product name Product code New build. ¹) Renovation ²) and length (mm) 60 40 ejotherm NT U 095 8796 095 400 80 60 ejotherm NT U 115 8796 115 400 100 80 ejotherm NT U 135 8796 135 400 120 100 ejotherm NT U 155 8796 155 400 140 120 ejotherm NT U 175 8796 175 400 160 140 ejotherm NT U 195 8796 195 400 180 160 ejotherm NT U 215 8796 215 400 200 180 ejotherm NT U 235 8796 235 400 220 200 ejotherm NT U 255 8796 255 400 240 220 ejotherm NT U 275 8796 275 400 260 240 ejotherm NT U 295 8796 295 400 ¹ ) 10 mm adhesive ² ) 10 mm adhesive and 20 mm old render Packaging: 100 pieces each. 20

ejotherm NTK U Telescope anchor l approved for concrete, solid and perforated masonry l defined move-in of the plate through the EJOT telescope effect: with the last blow, the plate decouples and moves on the sleeve while the expansion zone is safely anchored l safe and smooth installation with built-in setting control through the EJOT telescope effect l optimised thermal bridge l minimised risk of breaking nails due to fibre-reinforced composites l premounted expansion nail for quick installation Installation Technical data EJOT Telescope Effect Put the anchor into the borehole until the plate bears on the insulation, hammer the nail into the sleeve Anchor diameter Plate diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 60 mm 50 mm 40 mm A, B, C ETA-07/0026 Characteristic loads With the next blow the plate decouples from the sleeve and moves into the insulation Normal weight concrete C 12/15 acc. to EN 206-1 0.6 kn Normal weight concrete C 16/20 - C 50/60 acc. EN 206-1 0.9 kn Clay bricks (Mz) acc. to DIN 105 0.9 kn Solid lime sandstone (KS) acc. to DIN EN 106 0.9 kn Vertically peforated clay bricks (Hlz) acc. to DIN 105 0.6 kn Sand-lime perforated bricks (KSL) acc. to DIN EN 106 0.9 kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Product range Insulation (mm) Product name Product Code and length (mm) New build. ¹) Renovation ²) 40 ejotherm NTK U 090 8777 090 100 60 40 ejotherm NTK U 110 8777 110 100 80 60 ejotherm NTK U 130 8777 130 100 100 80 ejotherm NTK U 150 8777 150 100 120 100 ejotherm NTK U 170 8777 170 100 140 120 ejotherm NTK U 190 8777 190 100 160 140 ejotherm NTK U 210 8777 210 100 ¹ ) 10 mm adhesive ² ) 10 mm adhesive and 20 mm old render Packaging: lengths 090-150: 200, otherwise 100 pieces each. ejotherm NTK U length 230 available from mid-2008. Please contact your EJOT team. 21

EJOT additional plates Additional plates The plate diameter is enlarged through specially matched additional plates. In this way the EJOT plate anchor is perfectly fitted to the demands of different insulation materials. Which additional plates are used in a specific case, depends on the specifications of the ETIC system owner. EJOT VT 90 l plate diameter: 90 mm l high plate solidness for smooth move-in of the plate l smooth installation EJOT SBL 140 plus l plate diameter: 140 mm l specially for mineral wool lamella boards l high plate solidness for smooth installation l high buckling loads thanks to additional plaster bonding Product range Product name Product code Packaging (pieces) EJOT VT 90 8781 090 008 100 EJOT SBL 140 plus 8716 140 008 100 When using additional plates the STR principle cannot be applied. When combining our additional plates with ejotherm STR U or ejotherm STR H, the special STR closing plugs have to be mounted. 22

ejotherm anchors for rail fastenings ejotherm anchors for rail-fixed ETICS A special kind of External Thermal Insulation Composite Systems is the mechanical fixing of the insulation boards with the help of holding rails. These systems are preferably used on old facades with large tolerances (unevenness of the old render) or significantly damaged old render (lose parts, partially missing old render). Holding rails of plastic or aluminium are directly fastened on the substrate with special collar head anchors. Our spacers EJOT AS balance tolerances and bridge missing parts. Simply clip the chosen thickness onto the anchor between wall and holding rail ready! System-specific insulation boards are put into the profiles of holding rails through incorporated grooves. For additional anchoring of the insulation in the centre of the board, we recommend our cap anchor ejotherm STR U (see page 16). For problematic substrates we offer our special anchor EJOT SDF-K plus 8 U (page 31). 23

ejotherm SDK U Screw-in anchor for rails l for installing holding and base rails l approved for all categories of building materials l shortest anchorage depths, minimum drill hole depths l highest loads for maximum safety l economic anchor usage l premounted screw for quick installation l to compensate facade tolerances use spacers EJOT AS Technical data Installation Anchor diameter 8 mm Collar diameter 16 mm Drill hole depth h 1 >_ 35 mm (75 mm) Anchorage depth h ef >_ 25 mm (65 mm) Screw drive TORX T30 Use categories acc. to ETA A, B, C, D, E European Technical Approval (ETA) ETA-04/0023 Values in parentheses: anchoring in gas concrete (use category E) Characteristic loads Normal weight concrete C 12/15 acc. to EN 206-1 1.5 kn Normal weight concrete C 16/20 - C 50/60 acc. EN 206-1 1.5 kn Clay bricks (Mz) acc. to DIN 105 1.5 kn Solid lime sandstone (KS) acc. to DIN EN 106 1.5 kn Solid masonry of lightweight concrete (V) acc. DIN 18152 0.6 kn Vertically perforated clay bricks (Hlz) acc. to DIN 105 1.2 kn Vertical coring reference bricks (Hlz) acc. ÖNORM B 6124 0.75 kn Sand-lime perforated bricks (KSL) acc. to DIN EN 106 1.5 kn Lightweight concrete hollow blocks (HbL) acc. DIN 18151 0.6 kn Lightweight aggregate concrete (LAC) 0.9 kn Autoclaved aerated concrete P2 - P7 0.75 kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. To compensate facade tolerances use spacers EJOT AS (p. 26). Product range Max. tolerance Product name Product code compensation (mm) and length (mm) 20 ejotherm SDK U 045 8798 045 400 40 ejotherm SDK U 065 8798 065 400 60 ejotherm SDK U 085 8798 085 400 80 ejotherm SDK U 105 8798 105 400 Packaging: 100 pieces each, in box per 1,000 pieces. 24

ejotherm NK U Hammer-in anchor for rails l for installing holding and base rails l approved for concrete, solid and perforated masonry l shortest anchorage depths, minimum drill hole depths l high loads for high security l premounted nail for quick installation l to compensate facade tolerances use spacers EJOT AS Installation Technical data Anchor diameter Collar diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 16 mm 35 mm 25 mm A, B, C ETA-05/0009 Characteristic loads Normal weight concrete C 12/15 acc. to EN 206-1 1.2 kn Normal weight concrete C 16/20 - C 50/60 acc. EN 206-1 1.2 kn Clay bricks (Mz) acc. to DIN 105 1.5 kn Solid lime sandstone (KS) acc. to DIN EN 106 1.5 kn Solid masonry of lightweight concrete (V) acc. DIN 18152 0.5 kn Vertically perforated clay bricks (Hlz) acc. to DIN 105 0.9 kn Sand-lime perforated bricks (KSL) acc. to DIN EN 106 1.5 kn Lightweight concrete hollow blocks (HbL) acc. DIN 18151 0.5 kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. To compensate facade tolerances use spacers EJOT AS (p. 26). Product range Max. tolerance Product name Product code compensation (mm) and length (mm) 20 ejotherm NK U 045 8797 045 400 40 ejotherm NK U 065 8797 065 400 60 ejotherm NK U 085 8797 085 400 Packaging: 100 pieces each, in box per 1,000 pieces. 25

Accessories for rail fastenings EJOT spacers AS l for levelling out facade tolerances: lengths can be combined individually (3, 5, 8, 10, 15 and 30 mm) l simply clip onto the anchor between wall and rail l for anchor diameters 6 mm, 8 mm and 10 mm l sorted by colour EJOT profile connector PV l for connecting profile rails l simply clip onto the rail elements to be connected l facilitates the precise adjustment of base rails l length: 30 mm each EJOT nail anchors ND K 6 x 60 and 8 x 75 l premounted nail anchor to mount base rails l diameters: 6 mm and 8 mm l drill hole depth: >_ 40 mm l anchorage depth: >_ 30 mm EJOT installation set l special composition of frequently used accessories for installing base rails l set comprises: 75 nail anchors ND-K 6 x 60, 10 profile connectors PV, 50 spacers AS 3 Product range Product name Product code Packaging (pieces) EJOT AS 3 8600 725 700 100 (box: 3.000) EJOT AS 5 8601 189 710 100 (box: 2.500) EJOT AS 8 8601 233 720 100 EJOT AS 10 8601 232 750 100 EJOT AS 15 8601 187 730 100 EJOT AS 30 8601 188 750 100 EJOT profile connector PV 8792 030 770 2.500 EJOT ND-K 6 x 60 8561 660 400 100 (box: 1.000) EJOT ND-K 8 x 75 8561 875 400 100 (box: 1.000) EJOT installation set 8500 000 030 1 set (box: 10 sets) 26