3D seismic analysis of multi-storey wood frame construction

Similar documents
SEISMIC RETROFITTING OF STRUCTURES

A NEW DESIGN METHOD FOR INDUSTRIAL PORTAL FRAMES IN FIRE

VERIFICATION OF THE METHOD FOR IMPROVING ACCURACY OF SIMPLIFIED SEISMIC RESPONSE ANALYSIS OF STEEL RIGID FRAME VIADUCTS

G. Michele Calvi IUSS Pavia

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND

Hybrid simulation evaluation of the suspended zipper braced frame

Seismic Isolation Retrofitting of Japanese Wooden Buildings

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

CONTRASTING DISPLACEMENT DEMANDS OF DUCTILE STRUCTURES FROM TOHOKU SUBDUCTION TO CRUSTAL EARTHQUAKE RECORDS. Peter Dusicka 1 and Sarah Knoles 2

REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

SEISMIC ANALYSIS OF RC FRAMED STRUCTURES RETROFITTED WITH STEEL BRACES

EARTHQUAKE DISASTER MITIGATION USING INNOVATIVE RETROFITTING METHOD

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

SEISMIC DESIGN OF MULTI-STORY BUILDINGS WITH METALLIC STRUCTURAL FUSES. R. Vargas 1 and M. Bruneau 2 ABSTRACT

Seismic Risk Prioritization of RC Public Buildings

Seismic analysis of a 2-storey log house Jorge M. Branco a, Paulo B. Lourenço b, Chrysl A. Aranha c

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

SIESMIC SLOSHING IN CYLINDRICAL TANKS WITH FLEXIBLE BAFFLES

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

bi directional loading). Prototype ten story

MODELLING OF AN INFILL WALL FOR THE ANALYSIS OF A BUILDING FRAME SUBJECTED TO LATERAL FORCE

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE

SEISMIC APPROACH DESIGN COMPARISON BETWEEN

Specification for Structures to be Built in Disaster Areas

Optimum proportions for the design of suspension bridge

Behaviour of Prefabricated Timber Wall Elements Under Static and Cyclic Loading

INTRODUCTION TO LIMIT STATES

2016 IDEERS Rules for Graduate Teams. The List of Rule Revisions

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Current Status of Seismic Retrofitting Technology

HPF Hollow Shaft Unit Type

Seismic performance evaluation of an existing school building in Turkey

Structural Dynamics of Linear Elastic Single-Degree-of-Freedom (SDOF) Systems

Earthquakes and Data Centers

Methods for Seismic Retrofitting of Structures

EXPERIMENTAL OBSERVATIONS FROM SHAKING-TABLE TESTS ON SELECTIVE TECHNIQUES FOR REPAIR AND STRENGTHENING OF RC WALLS

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

TRAVELING WAVE EFFECTS ON NONLINEAR SEISMIC BEHAVIOR OF CONCRETE GRAVITY DAMS

SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY

AN IMPROVED SEISMIC DESIGN APPROACH FOR TWO-COLUMN REINFORCED CONCRETE BENTS OVER FLEXIBLE FOUNDATIONS WITH PREDEFINED DAMAGE LEVELS

Blast Proof Occupied Buildings

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

MONOTONIC AND CYCLIC LOAD TESTING OF PARTIALLY AND FULLY ANCHORED WOOD-FRAME SHEAR WALLS. Peter Seaders. Rakesh Gupta{ Thomas H.

NUMERICAL ANALYSIS OF A HORIZONTALLY CURVED BRIDGE MODEL

! # # % % & () +, & +,,. / 0 % % ) () 3

LINKED COLUMN FRAME STEEL SYSTEM PERFORMANCE VALIDATION USING HYBRID SIMULATION

SEISMIC RETROFIT DESIGN CRITERIA

Blast Resistant Building BP Refinery Rotterdam

Metodologie di valutazione del rischio sismico per grandi impianti industriali

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Nonlinear Structural Analysis For Seismic Design

Rehabilitation of a 1985 Steel Moment- Frame Building

CH. 2 LOADS ON BUILDINGS

BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS

SEISMIC RETROFITTING OF REINFORCED CONCRETE BUILDINGS USING TRADITIONAL AND INNOVATIVE TECHNIQUES

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE

EARTHQUAKE DESIGN OF BUILDINGS

SEISMIC TESTING OF NON-STRUCTURAL COMPONENTS AND ASSESSMENT OF THE PRESCRIBED RESPONSE SPECTRUM

Seismic Analysis and Design of Steel Liquid Storage Tanks

PARAMETRIC STUDY OF THE STRUCTURES (INFLUENCE OF THE SHELLS)

SEISMIC DESIGN OF HIGHWAY BRIDGES

RECOMMENDATIONS FOR THE DESIGN AND CONSTRUCTION OF BASE ISOLATED STRUCTURES

Chapter 6 ROOF-CEILING SYSTEMS

PERFORMANCE BASED SEISMIC ASSESSMENT OF UNREINFORCED MASONRY BUILDINGS IN NEW YORK CITY

Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift

List of Graduate Level Courses in Civil Engineering

Introduction to Beam. Area Moments of Inertia, Deflection, and Volumes of Beams

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

NUMERICAL ANALYSIS OF THE SEISMIC PERFORMANCE OF STEEL FRAMES INFILLED WITH COMPOSITE PANELS

Nonlinear numerical analysis of SRC-RC transfer columns based on OpenSEES

EARTHQUAKE INDUCED AMPLIFIED LOADS IN STEEL INVERTED V- TYPE CONCENTRICALLY BRACED FRAMES

PROHITECH WP3 (Leader A. IBEN BRAHIM) A short Note on the Seismic Hazard in Israel

Page & Turnbull imagining change in historic environments through design, research, and technology

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

THREE DIMENSIONAL NONLINEAR DYNAMIC MODELING OF A VERTICALLY ISOLATED ANCIENT STATUE DISPLAYED IN A BASE ISOLATED MUSEUM BUILDING

SOUTH AFRICAN NATIONAL INSTITUTE OF ROCK MECHANICS CHAMBER OF MINES OF SOUTH AFRICA CERTIFICATE IN ROCK MECHANICS PART 1 ROCK MECHANICS THEORY

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Development of Seismic-induced Fire Risk Assessment Method for a Building

Timber the material of choice for four soccer stadiums in Québec

INFLUENCE OF ENERGY DISSIPATING SYSTEMS ON THE SEISMIC RESPONSE OF CABLE SUPPORTED BRIDGES

Tall buildings. Florea Dinu. Lecture 13: 25/02/2014

Reinforced Concrete Design

CLASSIFICATION BOUNDARIES FOR STIFFNESS OF BEAM-TO- COLUMN JOINTS AND COLUMN BASES

Loads and Load Combinations for NBCC. Outline

CE591 Lecture 8: Shear Walls

REPAIR AND SEISMIC RETROFITTING OF HOSPITAL AND SCHOOL BUILDINGS IN PERU

Seismically retrofitting reinforced concrete moment resisting frames by using expanded metal panels

Seismic Retrofitting of Existing Structures

Chapter. Earthquake Damage: Types, Process, Categories

NONLINEAR BEHAVIOR AND FRAGILITY ASSESSMENT OF MULTI-STORY CONFINED MASONRY WALLS UNDER CYCLIC LOADS

OUTPUT-ONLY MODAL ANALYSIS FOR A 50 YEARS OLD CONCRETE BRIDGE

Transcription:

3D seismic analysis of multi-storey wood frame construction Ceccotti, Ario 1, Follesa, Maurizio 2, Karacabeyli, Erol 3 ABSTRACT In seismic design of multi-storey wood frame buildings, force reduction factors have been mainly evaluated through twodimensional (2D) dynamic analysis on the basis of "rigid floors - symmetric behavior" assumption. In this paper, results from a 3D non-linear time-history dynamic analysis are presented for a sample wood-frame building, symmetric. The building has been designed in Vancouver (B.C., Canada) according to the provisions of the Canadian Building Code, and then analyzed using a 3D dynamic analysis program which included a pinching hysteresis model fitted to the test data obtained on full-size nailed shear wall specimens. The analyses are performed for several Vancouver area based accelerograms and several historical quakes and repeated for flexible and rigid floors to study the effect of diaphragm flexibility on seismic performance. For each building and each accelerogram, the Peak Ground Acceleration (PGAu) producing the "near collapse" ultimate state has been determined. The influence of flexibility of floor diaphragms has been then quantified in terms of reduction of PGA u in respect to the reference "rigid/symmetric" case. INTRODUCTION Most seismic design codes contain action reduction factors (ARF) to be used to evaluate the forces to be accounted for when designing the structure using a simple elastic global analysis. ARF then reflects the capability of a structure to dissipate energy through inelastic behavior, and survive even exceptional earthquakes without complete collapse. In fact any code's objective is the building to resist the foreseen quake for that area. It is evident that behind this idea there is an assumption of acceptable risk for the community. Because resistance against earthquakes results from a combination of hazard and vulnerability, to take into account the relevant uncertainties (according to semi-probabilistic approach philosophy), appropriate safety coefficients are considered in the codes both for the design action and the design resistance. Therefore under these assumptions the easiest way to assess the appropriateness of an ARF value for a particular building type is just to refer to the definition of ARF: "ARF is the factor to be used in calculating design inertia forces so that a structure designed linearly elastic using the code strength values can survive the design quake intensity, even if heavily damaged, but without its compete collapse.", and apply the following procedure. Design the structure using the ARF according to the seismic code, and the resistant system according to the relevant codes (seismic and static codes). At the end of this step the resistant system will be completely anticipated. Model the building mechanical behaviour on the base of its mechanical characteristic (obtained by tests, and scaled to 5% percentile based on COV and test mean value, using additional safety coefficients eventually provided by the code for the earthquake load combination). Using a suitable non-linear analysis programme capable of following the displacement history of the building under a quake in the time domain, determine the PGAu that the building will survive without exceeding a given near collapse failure limit (for example based on a maximum inter-storey drift, or a rupture in joints or in timber elements). 1 Professor, Dept. of Civil Engineering, Florence University, S. Marta 3 I-50139 Florence ario@dicea.unifi.it 2 Research Fellow, Dept. of Civil Engineering, Florence University, S. Marta 3 I-50139 Florence mfollesa@tiscalinet.it 3 Group Leader, Wood Engineering Department, Forintek Canada Corp., 2665 East Mall, B.C. Canada V6T 1W5 erolk@van.forintek.ca

Compare this PGAu against PGAcode prescribed by the code. Finally, if PGAu > PGAcode the previously chosen design ARF value is adequate. This procedure must be repeated for a series of earthquakes suitable for the design site, in order to have a global picture according to different possible inputs. Note that this metodology does not need a definition of yielding limit, but uses only the definition of ultimate inter-storey drift limit. A lower yelding limit may be introduced to control damage in moderate earthquakes. If the design code values for materials strength are artificially low, the structure will be over-designed and consequently it will resist a greater PGA resulting in a greater margin between PGAu and PGAcode. Therefore this margin itself involves some kind of calibration of acceptable risk and becomes a matter for code writers (Ceccotti & Foschi, 1998). Using this methodology for multistory wood frame shear walls, these factors have been previously evaluated through two-dimensional (2D) dynamic analysis on the basis of "rigid floors - symmetric behavior" assumption (Ceccotti &Karacabeyli, 2000). The possible dynamic interaction between the floor deformability and the walls deformability has not be taken into account: under quake exitation a long building can deform along its length and some walls are more deformed than others, so that some walls can reach the near-collapse inter-storey drift while others not. Accordingly, the PGA producing the near-collapse state in a long building with deformable floors can be different from the PGA that produces the same effect in a building with rigid floors, where all walls are deforming in the same way. This is even more likely to happen in the case of non-simmetric buildings. MATERIALS AND METHODS Modeling joints The pinching hysteresis model was previously developed at the University of Florence (Ceccotti& Vignoli, 1989) for the semirigid connections. This is a fitting model as shown in figure 1a & b. The model needs to be calibrated to test data. It is a piece-linear model and therefore is not extremely precise. From an energy point of view however, the representation obtained with the model is reasonable (fig 2, max error 15%). Figure 2: Differences in energy dissipation according to Figure 1. Figure 1a,b: Florence hysteresis model fitting plywood shear-walls test. Preliminary test results on shaking table, figure 3a,b,c,&d) validated its ability in detecting the PGA u that is the most important parameter to be determined using this model.

Figure 3a,b: Shaking table test performed at NIED in Tsukuba, Japan (El Centro 0.35 g, 0.45 g) 2,50E+04 6,00E+01 1 st Floor 2,00E+04 1,50E+04 5,00E+01 4,00E+01 Tsukuba test Drain 2d Model Force (N) -4,00E+0 1-3,00E+0 1-2,00E+0 1 1,00E+04 5,00E+03 0,00E+00-1,00E+0 0,00E+00 1,00E+01 2,00E+01 3,00E+01 4,00E+01 5,00E+01 6,00E+01 1-5,00E+03-1,00E+04-1,50E+04 Tsukuba test Drain 2d model Displacement (mm) 3,00E+01 2,00E+01 1,00E+01 0,00E+00 0,00E+00 5,00E+00 1,00E+01 1,50E+01 2,00E+01 2,50E+01-1,00E+01-2,00E+01-3,00E+01-2,00E+04 Displacement (mm) -4,00E+01 Time (sec) Figure 3c: Force-displacement history under El Centro 0.35 g. Figure 3d: Displacement-time history under El Centro 0.35 g.

Building design A symmetric reference building has been designed in Vancouver (B.C., Canada) according to the provisions of the Canadian Building Code. It is a four storey building with 67.2 m length and 32.3 meter width. Shear walls are spaced at 9.6 m in short direction. Building was designed with ARF=3 where nailed plywood shear walls were the only lateral load resistant elements. The strength of gypsum walls was neglected. The fundamental period of vibration of the structure (To) calculated by using the Canadian Building Code was To= 0.2 seconds, that is much less than those found by dynamic analysis (see next). In determining the design shear force, however, To= 0.2 seconds was used. Modeling the building The building model is shown in figure 4, where timber equivalent frames with semi-rigid joints are used to simulate the behaviour of the actual walls. Figure 4: DRAIN 3D scheme for studied building Floors were considered both rigid and deformable. The second feature was simulated by considering cross bracing having the equivalent deformability of a plywood floor. Though the bracing is able to plasticize, an all-elastic behaviour was forced (so deliberately neglecting the further contribution to resist the quake action given by the dissipation of energy provided by the floors themselves). Bracing is working only in tension. The effective elastic periods of the whole building with deformable floors was found to be 0.53, 0.48 and 0.43 seconds for first, second and third mode of vibration respectively (fig 5 a,b & c), while for the case with rigid floors the correspondent periods were found to be 0.51, 0.23 and 0.19 seconds for the first, second and third mode of vibration rispectively. Raleigh damping of 5% was assumed, in order to consider the contribution to dissipation of energy provided by the gypsum walls.

Figure 5a: 1 st mode of vibration with deformable floors (T=0.531 s) Figure 5b: 2 nd mode of vibration with deformable floors (T=0.486 s) Figure 5c: 3 rd mode of vibration with deformable floors (T=0.431 s) Dynamic analysis A non-linear time-history dynamic analysis has been performed in one direction (parallel to the short dimension of the building) for the selected wood-frame building, using 3D version of DRAIN (Follesa, 1998) which included the Florence hysteresis model fitted to the test data obtained from cyclic tests on full-size nailed plywood shear wall specimens at Forintek Canada Corp. Western Laboratory in Vancouver (Karacabeyli & Ceccotti, 1996).

force Fmax 0.80 Fmax The analysis was performed for several historical quakes and some Vancouver area based accelerograms, and repeated for flexible and rigid floors to study the effect of diaphragm flexibility on seismic response of the building (12 accelerograms in total). δ2 δ1 δ 1 δ 2 δ max displacement The ultimate displacement, δ max, used as the "near-collapse" criterion, is defined as the displacement at 80 percent of the maximum load on the descending portion of the skeleton curve (Figure 6 ). Figure 6: Near-collapse criterion (δ max ) curves obtained in cyclic tests. No further adjustments were used. In the analysis, the skeleton curve for the hysteresis model is selected based on the 5th percentile (determined by assuming a 10 percent coefficient of variation and a normal distribution) of the first envelope Each accelerogram was scaled until the Peak Ground Acceleration (PGA u ) value producing the "near collapse" interstorey drift was reached in the most stressed wall (Figure 7 a&b) for both cases, rigid and deformable floors. Figure 7a: Deformed shape at the near-collapse interstorey drift Figure 7b: Deformed shape at the near-collapse interstorey drift Finally the influence of floor flexibility has been quantified in terms of a reduction in PGA u with respect to the reference "rigid/symmetric" case. RESULTS The results of non-linear dynamic analysis are shown in Figure 8 where the reduction of the peak ground accelerations causing the inter-storey drift to reach the shear wall's ultimate displacement δ max are shown for flexible floors versus rigid floor case according to the 12 accelerograms. These results lead to the following conclusions: deformability of floors reduced the achievable PGAu up to 15% maximum in most cases. Only in one case a 30% reduction was obtained.

0,9 94,6% 0,8 0,7 0,6 92,6% 93,7% 94,5% 0,5 0,4 90,7% 86,4% 93,5% RIGID FLOORS DEFORMABLE FLOORS 0,3 90,0% 0,2 89.1% 70,7% 90,6% 85,2% 0,1 0 NOEW ELCE JOSH KOBE LPEW TURK VN21 VN29 VN33 VN57 VN77 VN83 Figure 8: Loss in PGAu for deformable floors versus rigid floors. DISCUSSION ARF values previously found with a 2D analysis, given the unavoidable uncertainties in this problem, may be considered appropriate for symmetric buildings. Moreover the contribution of dissipation of energy has been neglected in the analysis, therefore one can expect even better behaviour in real life applications. Authors have not found any evidence of dramatic reduction of performance in buildings with deformable floors such the one found by Stiemer and Tremblay (1996) for steel buildings. This is probably due to the differences in building configurations. In platform frame timber buildings, in general, shear walls are regularly and closely-spaced while in the steel buildings studied by Stiemer and Tremblay, shear walls were very distant from each other (30, 60 and 120m) in respect to the width of buildings (15, 30 and 60m respectively). This leads to the conclusion that further research must be undertaken for industrial timber buildings, as the present results may be not applicable to them. In addition it is important to remember that regularities in plan and height are very important in order to assure an adequate behaviour under earthquakes. Buildings prone to torsion may be affected in a worst manner than symmetric buildings with deformable floor diaphragms. REFERENCES Ceccotti, A., and Foschi R.O. 1998. Reliability assessment of wood shear walls under earthquake excitation. Proc. Conference on Stochastic Mechanics, Santorini, Greece, 311-317. Ceccotti, A., Karacabeyli, E. 2000. Dynamic analysis of nailed wood-frame shear walls. 12 th World Conference on Earthquake Engineering, Auckland, New Zealand, 720, 1-8. Ceccotti, A., and Vignoli, A. 1989. "A Pinching Hysteretic Model for Semirigid Joints" European Earthquake Engineering Journal, Bologna, Italy, V3, 3-9.

Follesa, M. 1998. Seismic behaviour of wooden multi-storey buildings. Master Degree thesis (in Italian). Dept. of Civil Engineering, University of Florence, Italy. Karacabeyli, E. and Ceccotti, A. 1996. "Test Results on the Lateral Resistance of Nailed Shear Walls". International Wood Engineering Conference, New Orleans, USA, pp:v2,179-186. Tremblay, R.,Stiemer, S.F. 1996. Seismic Behavior of Single-Storey Steel Structures with a Flexible Roof Diaphragm. Canadian J. Of Civil Engrg., 23, 49-62