CN-1231 with Relay Base 9V DC CARBON MONOXIDE (CO) ALARM WITH ALARM RELAY OUPUT OWNER S MANUAL

Similar documents
Having a gas appliance installed or serviced? Doing home improvements?

Alarms. State of Wisconsin Rules ss (2) and (3) Comm Comm

Carbon Monoxide Alarm User s Guide

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

OWNER S MANUAL for Models:

CO-220 Carbon Monoxide Meter

Carbon Monoxide Alarm User s Guide

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

CO-9B User Manual CARBON MONOXIDE POISONOUS GAS ALARM

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Natural Gas Safety What You Need To Know

120 VAC, 60 Hz, 100 ma Maximum Single Station Carbon Monoxide Alarm Also suitable as a Residential Gas Detector

INTRODUCTION USER S MANUAL

Carbon Monoxide Alarm User s Guide

2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR. Model: EL-4703 INSTALLATION INSTRUCTIONS

Carbon monoxide. General information

Macurco CM-E1 Carbon Monoxide Detector

Fire Facts Carbon Monoxide

10 YEAR LIFE SMOKE ALARM

LOUTH COUNTY COUNCIL STATEMENT OF POLICY ON DOMESTIC FIRE DETECTION AND ALARM SYSTEMS

Upstate NY Recovery assistance information

San josé OWNER S MANUAL

Smoke Alarm User s Manual

Smoke and Carbon Monoxide Alarm

Smoke & Carbon Monoxide

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Fire safety for landlords

Fire Damage. To Help Prevent. a Guide

Sounding the Call Carbon Monoxide What You Need to Know

User Guide for the Kidde RemoteLync. Remote Notification Device

Carbon Monoxide and Explosive Gas Alarm User s Guide

WFS-627 User Manual. Wi-Safe Strobe Alert System Part of the Wi-Safe Home Safety System

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

User s Guide. Security Systems D220

CERTIFICATE OF COMPLIANCE

READ ALL INSTRUCTIONS

Fire Standards & Regulations Are you confused?

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EzFlex Combustible Gas Leak Detector Model EZ40

Smoke Alarm User s Guide

Carbon Monoxide Alarm User s Guide

Ionisation Smoke Alarm

SL280UHV SERIES GAS FURNACE WARNING

Environmental Asthma Triggers Kit

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

orlando OWNER S MANUAL

Smoke Alarm 120V AC. Smoke Alarm. Back-up. with 9V Battery IONIZATION MODELS AD, ADC PHOTOELECTRIC MODEL PAD

Natural Gas Safety. What You Need to Know

INSTRUCTION MANUAL PC255O

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

TWO BURNER PROPANE CAMPING STOVE

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

Wireless Indoor/ Outdoor Thermometer

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants)

Model Ei 225EN. Model Ei 220EN

Carbon Monoxide. Alarm. User s Guide U L. Kidde CO Alarm with Digital Display and Peak Level Memory Model: KN-COPP-3

INSTALLATION AND OPERATION MANUAL

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

Visit Us on the Web! MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL

User s Guide. Security Systems

User s Guide. Security Systems

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL

el-720 Carbon Dioxide Gas Leak Detector User s Guide

TX Carbon Monoxide Alarm Manual

INSTALLATION BASIC SAFETY INFORMATION USER S MANUAL PLUG-IN EXPLOSIVE GAS AND CARBON MONOXIDE ALARM WITH BATTERY BACK-UP AND SILENCE FEATURE

TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1

healthy homes assessment

System-Connected Carbon Monoxide Detectors

Safe Method: Gas Safety in Catering Establishments

INFRARED QUARTZ WALL HEATER

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels

Home Electrical Safety Challenge

INTRODUCTION BASIC SAFETY INFORMATION USER S MANUAL

TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2

Combination Smoke & Carbon Monoxide Alarm

The client organisation that was best at meeting residents needs in the provision of a maintenance service

Gas appliances. Get them checked Keep them safe. The problem

SMOKE/CARBON MONOXIDE ALARM MODEL FADCQ

How to Reduce Your Exposure to Chemicals at Home, Work, and Play

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

User Guide for the DS7060 Control/Communicator

cairn HMO Tenant Information Property Address: Letting: Maintenance:

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

TWO BURNER PROPANE CAMPING STOVE

SMOKE ALARM MAINTENANCE PROGRAM

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

AD-01 Slave Auto Dialer. Owner s Manual

Utilities (Natural Gas & Electricity)

READ AND SAVE THESE INSTRUCTIONS

120V AC Smoke Alarm with 9V Battery. Back-up IONIZATION MODEL ADC

MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

120V AC Smoke Alarm with 9V Battery Back-up

Indoor Air Quality. 2. Test and identify sources that contribute to poor indoor air quality.

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Transcription:

CN-1231 with Relay Base 9V DC CARBON MONOXIDE (CO) ALARM WITH ALARM RELAY OUPUT OWNER S MANUAL CAUTION : READ THESE INSTRUCTIONS CAREFULLY BEFORE OP- ERATING OR SERVICING. PLEASE LEAVE A COPY TO THE END USER. CARBON MONOXIDE ALARM Alarm Fault Power T e s t & H u s h IMPORTANT! THIS IS NOT A SMOKE ALARM! This CO alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas. WARNING! This product is intended for use in ordinary indoor locations of family living units. Do not expose to rain or moisture. The detector will not protect against risk of carbon monoxide poisoning when the battery is flat. Do cover the alarm when decorating. REMEMBER to uncover the unit when decoration is finished (excessive fumes from paints, solvents, cleaning agents, etc. may damage or deteriorate sensor). The CO alarm shall not be seen as a substitute for proper servicing of fuel-burning appliances, or the sweeping of chimneys. WARNING! THIS ALARM CONFORMES TO BSEN50291:2001 MAY NOT PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CAR- BON MONOXIDE EXPOSURE. IT WILL NOT FULLY SAFEGUARD INDI- VIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN ANY DOUBT, CONSULT A MEDICAL PRACTITIONER. Copyright 2008 Deltronic Security AB

NEVER IGNORE THE CO ALARM CO is called the silent killer because it is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. Electrical appliances typically do not produce CO. Many cases of reported CO poisoning indicate that while victims are aware they are not well, they become so disoriented, that they are unable to save themselves by either exiting the building or calling for assistance. Be aware that CO poisoning may be the cause of flu-like symptoms such as headaches, tightness of chest, dizziness, fatigue, confusion and breathing difficulties. Because CO poisoning often causes a victim s blood pressure to rise, the victim s skin may take on a pink or red cast. Extreme exposure to CO can cause brain damage, death. WARNING: EXPOSURE TO HIGH LEVELS OF CARBON MONOXIDE CAN BE FATAL OR CAUSE PERMANENT DAMAGE AND DISABILI- TIES. COMMON RISKS FOR CO POISONING Technical problems with equipment, depending on faults, lack of service or maintenance. Faulty chimney or ventilation pipe which can have fallen or clogged(e.g. bird nest, snow, etc.) Faulty ventilation direction of air, so called back draught. Faulty installation of burner. In equipment which is used regularly; for shorter periods of time, or by different people. Chimneys of the wrong size etc. Garden grills which are used indoors.

INSTALLATION: CAUTION: DO NOT INSTALL THE ALARM IN NEW OR RENOVATED BUILDINGS UNTIL ALL WORK IS COMPLETED, INCLUDING PAINT- ING AND FINAL CLEANING (EXCESSIVE FUMES FROM PAINTS; SOL- VENTS, MAY CAUSE DAMAGE AND DIRT OR DEBRIS MAY BLOCK THE GAS ENTRY). The CO Alarm is designed for easy installation. It comes completely with mounting kit. All you have to do is attach the mounting bracket to the wall with the fixing screws provided. 1. Loosen the mounting bracket by pushing it upwards and then fasten it onto the ceiling/wall with the enclosed screws. 2. Connect the battery with + ve and ve in the correct position and close the battery cover. 3. Connect snap contact to relay base and all connecting wires through the cable entry. 4. Fix CO alarm to the relay base with the screws provided. 5. Hook the relay base on bracket until it locks in place. Now, test Warning: Wiring should be installed the alarm by pressing in the test only by a qualified electrtian. button for a few seconds until the alarm sounds. LOCATION WHERE TO INSTALL CO ALARM Minimum Protection Added Protection The alarm should be installed in every level of your home, preferably in every room. If this is not possible, install at least one alarm near or within

CARBON MONOXIDE ALARM Alarm Fault Power T e s t & H u s h each separate sleeping area. If more than one sleeping area or the bedroom doors are closed during the night, you may need more than one CO alarm For added protection, install at least one CO alarm in each level of the home and at the top of the basement stairs. Install an additional CO alarm at least 6 meter (20 feet) away from the furnace or fuel burning heat source or appliance. CO alarm is available for boats and recreational vehicles. IMPORTANT: CO alarm should be placed where you will hear it while sleeping. min 1,5 m 15 cm In normal environment, wall mounted at least 1.5 meter (6 feet) from the floor is recommended. If on wall position, at least 150mm (6 inch) below the ceiling. If ceiling position, at least 300mm (12 inch) from any wall. Higher than any door or window frame. WARNING! The unit does not work without power. CO alarm is an early warning device, no more, no less. DO NOT PAINT the alarm. WHERE NOT TO INSTALL CO ALARM Within 1.5m (5 feet) of any gas appliance as furnace. In any high level of dusty, dirty or greasy area In damp or very humid areas, outdoor room or next to bathroom, at least installed the alarm 3 meters (10 feet) away from the bathroom. In very cold or very hot area where the temperature could not be less than -10ºC or greater than 40ºC. Humidity is less than 30% RH or more than 90% RH. In direct sunlight and direct above a sink or cooker. Behind drapes, curtains, furniture or other obstruction. In unheated basements or garages. In location where they are exposed to chemical solvents or cleaners. Near vents, flues and chimneys. Near heating and cooking appliances. In turbulent air, like near ceiling fans, heat vent, air conditioners, fresh air return, or near the open window, because of the blowing air may delay CO from reaching the alarm.

OPERATING AND TESTING CO ALARM When the battery is installed, Green LED will flash once indicating the alarm is powered and wait for about 1 minute to stabilize the sensor before testing the unit. To test the unit, press and hold the button until the repeating series of 4 beeps sound with Red LED flashes. When the button is released, the siren will stop. Check and test the CO alarm after installation. Ensure that you can clearly hear the CO alarm in sleeping area. It should be tested weekly and check after reoccupation following a holiday. Check that Green LED flashes about every minute to ensure the unit is in operating mode. If the Green LED is not flashing once per minute, or the unit does not respond to the test button: 1. 2. 3. 4. Make sure the unit contains the recommended type of battery Ensure the battery is installed correctly. Make sure the unit has been cleaned adequately. Check for obvious damage. If the alarm still fails to work, it must be replaced immediately. Do not attempt to repair it yourself, warranty will be void. Note: The test push button is independent function with hush button. During the normal testing mode, the silence feature will not active. ADDITIONAL FEATURES The CO alarm comes with the following friendly additional features for use. Silence feature - This feature can be used to silence nuisance alarms. Press test/silence button during alarm condition will silence the alarm signal for 4 minutes. If the CO surrounding level reaches 200 ppm, the alarm will reactivate. Observe that the Red LED repeatedly series 4 flashes during hush model last for 4 minutes. The unit will automatically return to normal mode after 4 minutes. If the concentration is increased, the silencer (hush) feature is by pass and the unit will alarm. CAUTION : If the CO concentration at 200 ppm the silence feature does not activate. The user must be aware that if the alarms continually after push the silence button, the CO concentration surrounding the alarm could be 200 ppm or greater. Always determine why the alarm has been trigged before using the silence feature. If the case of alarm is not clear, assure that there is an actual CO leakage and evacuate the area.

Relay output The relay wich the CO alarm is mounted on is equipped with a latching relay output for connection with external equipment (N.O. and/or N.C.). Interlink function - This alarm can be interlinked with up to 11 other alarms (12 in all) using the interlink terminal located next to the relay terminal on the relay base. When your CO-alarm receives a signal from other units it will be triggered to alarm as well and red LED will flash continuously. If you wish to silence the incoming alarm, press the silencer button and only the red LED will continue to flash. Pre-alarm warning when the unit detects CO level 40 ppm or greater, the Red LED will flash every 8 seconds until alarm. Memory function - When a unit alarms due to CO or other reasons (not from test button), the memory function will be activated in the unit that has detected the CO and will be held for 12 hours. The indication of an alarm incidence being stored in the memory function consists of a short beep every 8 seconds. During this memory indication period, the normal operating and function of the unit is not affected and the user can reset/deactivate the memory function by pressing the test push button until an alarm sounds. Self diagnostics Automatically check the sensor every 8s to ensure of correct operating of alarm. Low battery warning When the battery power deteriorated, the unit will emit one beep with Yellow LED flash every minute to remind user to replace battery. Fault warning If a fault is detected, the unit will emit 2 beeps with Yellow LED flash every 8 seconds to indicate the sensor is fault or not working properly so CO alarm must be replaced. End of alarm life warning When the CO alarm comes to end of life, the unit will emit 3 beeps with Yellow LED flash every minute. When this happen, the CO alarm must be replaced. Temporary delay warning signal When the time to replace battery or end of life CO alarm warning occurs, the user can push the testbutton to temporarily disable low battery- or end of life- warnings for 12 hours to avoid beeing unnecessarily bothered by the signal especially in the middle of night. This is indicated by 3 flashes with Red LED. User may press test button to alarm again to deactivate function and return to warning mode at any time. CO ALARM SOUNDS 1. If you hear the CO alarm sound or suspect that there is a gas leakage, never ignore it. 2. Move to fresh air immediately. Outdoors or open all windows and doors to allow the CO to disperse.

3. 4. 5. 6. Call the Fire department immediately outside your home or premises/apartment. Do a head count to check all persons are accounted for. Do not re-enter the premises nor move away from the open door/windows until the emergency service responders have arrived, the premises have been aired out, and your alarm remain in its normal condition. Call a qualified technician to examine and investigate for source of CO from fuel burning, equipment and applications, such as water heater, oven, clothes dryer, space heater, furnace or other source of combustion, such as gas log fireplace or kerosene burning stove or heater. Make sure that motor vehicles or truck are not, and have not been, operating in an attached garage or adjacent to the residence. TECHNICAL INFORMATION The CO alarm is calibrated to respond to the following levels of CO in accordance with EN50291 : 2001. CO concentration No alarm before: Alarm before: in Air: 30 ppm 120 min. - 50 ppm 60 min. 90 min. 100 ppm 10 min. 40 min. 300 ppm - 3 min. The battery lasts for over one year. About a month before the battery is completely flat, the alarm emits a short signal with Red LED flashes every minute. This is the signal that the battery needs replacement. The alarm works as normal during this time. Always test the alarm after changing the battery. Replace battery with GP1604A, Duracell MN1604, Energizer 522, Eveready 1222 and Ultralife U9VL-J type. WARNING : Battery replacement should only be done by competent person. HOME SAFETY GUIDE Make a floor plan indicating all doors and windows. Have a family meeting, discuss the escape plan and train them to leave your home when they hear the sound of the alarm. If you are on holiday, turn off appliances switches & the gas control valve. Do not place the bed near gas pipes or gas meter. Do not change the location of gas pipes by yourself. In order to ensure your home safety, please employ registered installers for regular safety inspection of all gas installation & appliances. Out of reach of children. Teach the children not to play with it or remove the battery for other purpose.

ALARM SIGNAL & LED INDICATION Note : represents beep, beep, beep Detector Operation Normal Operation Green Red Yellow Power indication Alarm signal Fault signal Flash once per minute Alarm Condition - 4 beeps + flash - Silence (hush) mode under alarm condition Interlink signal input (slave) To activate silence(hush) unit under interlink signal input Pre-alarm warning CO level (40 ppm or greater level detected) Memory functionindicates the alarm has been activated before(not from test button) due to whatever reason Low Battery Warning Alarmsignal - - - -1s - -1s - - 4 flashes - - - beep + flash -. - Flash - - - Flash once every 8 seconds until alarm - - - - - Sensor Fault - - End of sensor lifetime warning Temporary delay warning signal (Push button to temporarily disable low battery- or end of life- warnings for 12 hours) - - - Flashes 3 times after a push of the button (Push button again to return to warning mode at any time) - - 1 beep + flash every minute 2 beeps + flash every 8 seconds 3 Beeps + flash every minute --8s-- --8s-- 1 beep every 8 seconds last for 12 hours. Press button once to reset to normal mode -1 min- - 1min-. -8s- -8s- - 8s- -1min- - 1min- - -

MAINTENANCE Do not allow water or dust to contaminate the alarm. Test it at least once a week by using the test button. A vacuum cleaner hoes and vacuuming the openings on the alarm. Use a damp cloth to wipe the outside of the alarm. Never use cleaners, aerosol chemicals, solvents or cleaning solutions on your alarm since they may damage the unit. Test the alarm after vacuuming and cleaning. Check the Green LED flashes about once per minute. 3 YEARS LIMITED WARRANTY The CO alarm is warranted for 3 years (excluding battery) to be free from defects in materials and workmanship from the date of purchase. This only applies if the alarms is used in the normal way and is serviced regularly. The obligations of this warranty, at our discretion, shall be limited to the repair or replacement of any part of the alarm and is also conditional on the CO Alarm s not having been tampered with, modified or subject to attempted repairs. Your statutory rights as a customer are in no way compromised by this Warranty. Limitation on Liability: The manufacturer will not be liable for the loss or damage of any kind, such as personal injury, property damage including incidental or consequential damages, resulting directly or indirectly from the failure of this product to activate from gas leakage, fire or explosion. If your Co alarm is faulty, please return with proof of purchase with problem clearly stated and postage prepared to: Importer: