FIRE PREVENTION STANDARD #20 NFPA PLACARDS

Similar documents
Hazard Warning Signage Guidelines

A placard provides the viewer with a variety of information through several different methods. First is the color of the placard.

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

Hazardous materials can be silent killers. Almost every household and workplace has varying amounts of chemicals that, if spilled or combined, will

FDNY C14 Certificate of Fitness Quiz

Model Plan for Auto Repair / Maintenance Facilities

Hazardous materials can be silent killers. Almost every household and workplace has varying amounts of chemicals that, if spilled or combined, will

DOT 126F Hazardous Material Awareness. Oregon State University Environmental Health and Safety

Hazmat Materials Training Fact Sheet Module 2 Classification. The classification of hazardous materials is based on three key factors:

Facility Operations Physical Safety Guidance Document

Department of Transportation Hazardous Material Regulations General Awareness, Safety & Security Training. For: University of Dayton Hazmat Employees

Section A - 3 IDENTIFYING HAZARDOUS MATERIALS

Globally Harmonized System Pictogram Reference Table

Mechanical Systems Competency 1.20

Dangerous Goods Hidden Dangerous Goods

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

2002 E D I T I O N INSTRUCTOR

Section 1. WHMIS Classes and Symbols

Requirements for Hydrogen Storage and Use

Hazardous Material Waller County ARES training material used with permission from Christine Smith, N5CAS.

UCLA - Compressed Gas Cylinder Storage and Handling

Handling and Storage of Flammable Materials at the Work Site

Certain specific properties of compressed gases make them highly useful in various research activities.

CHEMICAL INVENTORY WORKSHEET INSTRUCTIONS

Environmental Safety Division University of Georgia Right to Know Training

Safe Storage of Chemicals

HAZARDOUS MATERIALS. Transportation Regulations at Tunnel and Bridge Facilities GEORGE WASHINGTON BRIDGE LINCOLN TUNNEL HOLLAND TUNNEL BAYONNE BRIDGE

Health and Safety Guidance

Handling and Storage of Flammable Materials at the Work Site

Section III Hazardous Materials Management

Color Coded Labeling System for Storing Chemicals in your Laboratory

BUSINESS LICENSE (2014) CHARTER TOWNSHIP OF FLINT 1490 S. DYE ROAD, FLINT Ml (810) OR FAX (810)

EACH CLASS of fire A, B, C, or D has a different source. Some

York County Department of Emergency Services Communications Division

Compressed Gas Cylinder Program

Hazardous Substance Class Definitions & Labels

HAZARD COMMUNICATION PROGRAM. Raul F. Garcia-Casariego CSP, CHMM Industrial Hygienist

ENVIRONMENT, SAFETY, HEALTH, AND QUALITY DIVISION

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

Code Compliance Guideline: Swimming Pool Chemicals

Compressed Gas Cylinder Safety

Any other time call the SFASU Police at Emergencies 911 Non-emergencies

Hazard Communication/Globally Harmonized System (GHS) Program

Process Safety Management of Highly Hazardous & Explosive Chemicals. Application, Exclusions & Definitions

FACT SHEET. The following information is available from OSHA s Hazard Communication website, located at OSHA s Website. Hazard Communication Standard

Presented by: Rich Perry Marsh Risk Consulting

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

HAZARDOUS CHEMICAL WASTE DISPOSAL SECTION 7

Compressed Gases The Dangers

Flammable and Combustible Liquids. Slide 1 (of 23)

PRODUCT IDENTIFICATION SYSTEM FOR TERMINALS / DEPOTS IN SOUTH AFRICA

Training Requirements for the Revised Hazard Communication Standard

Section 1: Identification. GLO GERM POWDER All colors

Use, Handling and Storage of Compressed Gases and Cryogenic Liquids

Laboratory Safety Manual

LPG, Flammable Liquids, Toxic and Corrosive Substances

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Proper chemical storage is required to minimize the hazards associated leaks, spills, and accidental mixing of incompatible chemicals.

Gas Cylinder Safety.

IB Chemistry. DP Chemistry Review

Chapter XIV OCCUPATIONAL SAFETY AND HEALTH ACT. The Occupational Safety and Health Act (the Act ), 29 U.S.C. 651, et seq., is

Hazardous Waste Procedures. Faculty of Science University of Ottawa

Color Coding and Signs

CHAPTER 3 OCCUPANCY CLASSIFICATION

Fire Alarm System Accessories

User Guide for. Hazardous Material Awareness Training

Agenda. Overview of changes to the Hazard Communication Standard (Haz Com) Labeling requirements Safety Data Sheets (SDS) format 16 sections

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Compressed Gas Cylinder Storage and Handling Guide

University of Tennessee Safety Guidelines

HazCom 2012: Overview of OSHA s Revised Hazard Communication Standard

Temple College Compliance with the Environmental Protection Agency Requirements

University of Pittsburgh Safety Manual Subject: COMBUSTIBLE METALS. EH&S Guideline Number: Effective Date 09/10/13.

UNIVERSITY OF TOLEDO

Work Health and Safety Regulations: Classification and labelling for workplace hazardous chemicals

Hazardous Waste Determination and Management Plan

Packing for Transportation

WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

MaxCell Technical Manual Design Parameters

Vacuum and Compressor Systems for the Chemical Process Industry

MATERIAL SAFETY DATA SHEET

13. How many containers are typically shipped per waste pickup per location? a. The City of Frisco typically has containers per pickup.

Material Safety Data Sheet

Transport of Dangerous Goods by Road

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

BCGA LEAFLET L1. Guidance for Carriage of Gas Cylinders on Vehicles. Rev 2 : 2009

Guide to Certification for Retail Hardware Stores

Safe Operating Procedure

HAZARDOUS AREA TECHNICAL GUIDE

Safety Data Sheet. Document Group: Version Number: Issue Date: 05/26/15 Supercedes Date: 10/09/14

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS)

Storage and Handling of Gas Cylinders Guidelines

sara 312 & 313 emergency planning & community right-to-know act

A Guide to the Transportation of Dangerous Goods Regulations

OSHA 2012 Revised Hazard Communication Standard. USC Upstate OSHA Employee Training September 2013

Pollution Liability Exposure: Adjustments your automotive business should consider to maintain compliance

Environmental. and. Health Chemical Safety CHEMICAL WASTE DISPOSAL

Material Safety Data Sheet

1. IDENTIFICATION. US IVD HCCA, portioned BD Bruker US IVD HCCA, Portioned

Transcription:

Livermore-Pleasanton Fire Dep artment FIRE PREVENTION STANDARD #20 NFPA PLACARDS The Livermore-Pleasanton Fire Department uses the NFPA placarding system to warn firefighters responding to emergencies that a facility contains hazardous materials and to inform them of the general type and severity of hazards associated with those materials. When Required NFPA placards are required where the presence of the placards would be of assistance to firefighters. The attached document Threshold Quantities requiring NFPA placards provides guidelines for determining when to require NFPA placards. However, facilities that meet one or more of the criteria below generally do not need to be placarded: Facilities with such small amounts of hazardous materials that the presence of placards would be or no value or would imply as level of hazard that does not exist (for example, a print shop with 20 gallons of flammable liquid). The presence and nature of the hazardous material(s) is well known (for example, a gasoline station). In some cases a part of the facility may be placarded while another not (for example, a hardware store where the sales area is not placarded but the back room containing a diesel generator is placarded). Where Posted Placards may be required on any of the following areas when the area contains hazardous materials indicating placards would be useful 1) Outside areas on gates or fences. 2) Aboveground tanks (generally when the material is not a common material, such as diesel or LPG). 3) Doors to rooms or areas. 4) Buildings (generally the upper right-hand corner of each wall) for multi-tenant buildings a placard is placed on the front door or window near the door, and on or over every other exterior door. Design Criteria The placards are designed to warn of health, flammability, reactivity and special hazards. A ranking of 0 to 4 is used, with 4 being the most severe. Below is an example of an NFPA placard design. Page 1 of 7

SAMPLE Flammability (red) Health (blue) 1 3 Y 2 Reactivity (yellow) Special Hazard (white) NFPA Standard 704 contains specific information concerning this system. However, the following summary information is commonly useful: Placards on buildings and outside areas must be 16-18 inches square [character color - black, character minimum size: height - 6", stroke - 15/16"] Placards on rooms inside must be 8-12 inches square [character color - black, character minimum size: height - 3.5", stroke - 11/2"]. When possible, placards should be placed over doors or on the side of the door not covered when the door is open, not on doors or on the side covered by the door when it is open. The goal is that the sign be readily visible to a firefighter wearing self-contained breathing apparatus.. Placards can be made of variety of materials but the colors must be clear, the writing legible and the signs durable. NFPA Standard 704 contains more detailed information Placards are to be located as required by the Fire Department. Placards are placed so as to be visible from the approaches that may be used by the Fire Department The ranking for some common materials are provided on the next page. More detailed guidelines on ranking materials are available from the Fire Prevention Bureau. For assistance call Danielle Stefani at (925) 454-2338 or Julie Wyman at (925) 454-2336. Placards can be obtained from a variety of sources including many safety supply companies and firms that carry labels and signs. The following companies are listed for your convenience - there are many others. Lab Safety Supply 1-800-356-0783 Label Master 1-800-621-5808 HCL Labels 1-800-421-6710 Industrial Safety 1-800-537-9721 Page 2 of 7

HAZARD DESIGNATIONS FOR COMMON MATERIAL Chemical Name Health Flammability Reactivity Special Acetone 2 3 0 Acetylene 1 4 2 Acetylene Argon (compressed) 1 0 0 Aromatic hydrocarbon solvent (paint thinner) 2 3 0 Carbon dioxide (compressed) 1 0 0 Chlorine gas 3 0 0 Y Diesel Fuel 0 2 0 Ethylene glycol (antifreeze) 1 0 0 Freon Refridgerant 2 0 0 Gasoline 1 3 0 Helium (compressed) 1 0 0 Hydrogen (compressed) 1 4 0 Isopropyl alcohol 2 3 0 Kerosene 1 2 0 Lead Acid Batteries 2 0 0 (20% Acid) Muriatic Acid (hydrochloric 3 0 0 acid) Nitrogen (compressed) 1 0 0 Nitrous Oxide 1 0 2 Y Oil 0 1 0 Oxygen (compressed) 1 0 0 Y Oxygen (cryogenic) 3 0 0 Y Propane (LPG) 2 4 0 Safety Kleen Parts Cleaner 1 2 0 Sodium Hydroxide 3 0 1 Stoddard solvent (parts cleaner) 2 2 0 Sulfuric Acid 3 0 2 W Page 3 of 7

Placard Designations Based on Hazard Classification Categories The placard warning system numbers for each hazard category will be selected according to the following criteria: HAZARD CATEGORY Combustible Liquid II Combustible Liquid IIIA Combustible Liquid IIIB Combustible Dust Combustible Fiber Cryogenic Flammable Cryogenic Oxidizing Explosive Flammable Solid Flammable Gas (Gaseous) Flammable Gas (Liquefied) Flammable Liquid 1A Flammable Liquid 1B Flammable Liquid 1C Organic Peroxide, UD Organic Peroxide I Organic Peroxide II Organic Peroxide III Organic Peroxide IV Organic Peroxide V Oxidizing Gas (Gaseous) Oxidizing Gas (liquefied) Oxidizer 4 Oxidizer 3 Oxidizer 2 Oxidizer 1 Pyrophoric Gases Pyrophoric Solids, Liquids Unstable Reactive 4D Unstable Reactive 3D Unstable Reactive 3N Unstable Reactive 2 Unstable Reactive 1 Water Reactive 3 Water Reactive 2 Water Reactive 1 Corrosive Toxic Highly Toxic Page 4 of 7 F2 F2 F1, H3, H3 F2, R3, R3 F2, R2 F1, R1 Nonhazard R3 R2 R1 W, R3 W, R2 W, R1 H3 H3 H4 DESIGNATION

Irritant H2 Sensitizer H1 Radioactive H4, RAD Carcinogen H4, 3, 2, or 1 Other Health Hazards H3, 2 or 1 F - Flammable category R - Reactive category H - Health category W - Special hazard: water reactive - Special hazard: oxidizing properties RAD - Special hazard: radioactivity (symbol used) UD - Unclassified detonable material 4D - Class 4 detonable material 3D - Class 3 detonable material 3N - Class 3 nondetonable material THRESHOLD QUANTITIES REQUIRING NFPA PLACARDS Hazard Rating Amount requiring outside placarding on Category Number a building or exterior area HEALTH 4 More than 100 lbs. or 10 gals. or 50 cu. ft. 3 More than 100 lbs. or 10 gals. or 50 cu. ft. 2 More than 500 lbs. or 55 gals. or 1,000 cu. ft. 1 More than 1,000 lbs. or 110 gals. or 2,000 cu. ft. FLAMMABILITY 4 More than 500 lbs. or 55 gals. or 1,000 cu. ft. 3 More than 500 lbs. or 55 gals. or 1,000 cu. ft. Page 5 of 7

2 More than 1,000 lbs. or 110 gals. or 2,000 cu. ft. 1 More than 2,000 lbs. or 220 gals. or 4,000 cu. ft. REACTIVITY 4 More than 100 lbs. or 10 gals. or 50 cu. ft. SUBDIVISION PLACARDS 3 More than 100 lbs. or 10 gals. or 50 cu. ft. 2 More than 500 lbs. or 55 gals. or 1,000 cu. ft. 1 More than 500 lbs. or 55 gals. or 1,000 cu. ft. Subdivisions (rooms or compartments) of buildings or areas within a facility will be placarded to indicate the greatest possible hazards within those subdivisions. Placards that are placed to identify hazards in building or area subdivisions due to storage or process shall be affixed next to access points into the subdivisions. These placards must be visible when doors into subdivisions are open or closed. Placards will be required when the following amounts of materials are stored or used in a subdivision. Hazard Rating Amount requiring outside placarding on a Category Number building or area within a facility HEALTH 4 Any amount 3 Any amount 2 More than 100 lbs. or 10 gals. or 50 cu. ft. 1 More than 500 lbs. or 55 gals. or 1,000 cu. ft. FLAMMABILITY 4 More than 100 lbs. or 10 gals. or 50 cu. ft. 3 More than 100 lbs. or 10 gals. or 50 cu. ft. 2 More than 500 lbs. or 55 gals. or 1,000 cu. ft. Page 6 of 7

REACTIVITY 4 Any amount 1 More than 1,000 lbs. or 110 gals. or 2,000 cu. ft. 3 Any amount 2 Any amount 1 Any amount NOTE: Placards will not be required for underground storage of motor fuels. For further information contact: The Livermore-Pleasanton Fire Prevention Bureau 4550 East Avenue Livermore, CA 94550 Phone: (925) 454-2362 Fax: (925) 454-2367 Page 7 of 7