100 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit!

Similar documents
Wear Resistant Tubing

Socket case Socket. Easy insertion of tube by the floating mechanism to adjust to the case hole. Clamp bolt. Possible to clamp with one bolt at once.

Table of Contents - Tubing

3 Port Solenoid Valve

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

LCD Readout Digital Pressure Switch

Flushing and Cleaning the A/C System

PBX Series Quick Fit Connector Bimetallic Steam Traps

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

SunMaxx Solar Filling Station Operating Instructions

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

15GAL STEEL OIL DRAIN WITH 110V PUMP

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

IMPORTANT DOCUMENTATION DO NOT DISCARD!

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Operating Instructions Drill rig DRU160

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

HYDRAULIC LIFT TABLE CART 2200-LB.

Procenter Delivery System* Troubleshooting Charts

Trouble Shooting. Pump

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)

Float and Thermostatic Traps Series H, C and X

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

SELECTION, APPLICATION & MAINTENANCE

UV100A Ultraviolet Air Treatment System

National- Spencer Inc.

This instruction is valid for all ACD pump models shown on page 2

CARING FOR YOUR WATER HEATER

Installation Instructions S

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Cooling system components, removing and installing

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Round Housing with Side Ports

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

12 Volt 30 Amp Digital Solar Charge Controller

Portable Air Conditioner

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie

Assembly instructions VOSS quick connect system 246 NX

Model 43AP Pneumatic Controller, Style B

Morini CM 162EI. Technical Data

GenStore Archive Cabinet

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

SMD Rework Station TABLE OF CONTENTS

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

USER S MANUAL HSC-24A

BOWIE PUMPS OPERATION - MAINTENANCE

M A N U A L

CHROME FRONT BRAKE MASTER CYLINDER KIT

In-Line Filters and Coalescers with Automatic Drains

PORTABLE AIR CONDITIONER

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

3/4 PIPE CLAMP WITH STAND

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Single Phase Soft Starter

Series Hose Reels

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Reverse Cycle Inverter Split System Air Conditioner

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

High-Purity Fluoropolymer Fittings

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Submersion/Insertion Toroidal Sensor

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

Hydraulic control unit series

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Step-by-step instructions:

3 configurations provide design solutions based on the operating conditions. Male Connector Type. Can be mounted directly onto equipment

TYPE E Main Valve Sizes 3 /8 through 12

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

INSTALLATION & OPERATING INSTRUCTIONS

Transcription:

In-line Air Filter Series For tubing sizes ø2 and ø3.2, refer to Air Suction Filter/Series on SMC website. Operating pressure range kpa to 1. MPa Both positive pressure and vacuum pressure can be used with one unit! Positive pressure 1. MPa e.g.) Protection of solenoid valves Series Variations 5 7 Series Positive pressure to 1 MPa OUT Vacuum pressure kpa Filtration 5 µm Vacuum pressure to kpa Workpiece Maximum flow rate under positive pressure [] Metric size Inch size ø4 ø5/32" 45 ø1/4" ø1/4" 1 ø5/16" 25 ø ø3/8" ø12 Pad Protection of equipment under dust environment RoHS OUT 35 Flow rate (positive pressure)conditions: Supply pressure.1 MPa, Differential pressure kpa F D H E F AD Metric size: 5 sizes Inch size: 4 sizes Light gray Orange 261

With lock mechanism During positive pressure, prevents components from being scattered when they are loosened. 2 types of transparent case materials are available. Polycarbonate (Standard) Possible to degrease with alcohol. 2 element colors are available. No adhesion of foreign matter Nylon (Made to Order) Resistant to coolant oil Blue element (Made to Order) White element (Standard) With One-touch fitting Metric size: ø4 to ø12 Inch size: ø5/32" to ø3/8" Adhesion of foreign matter 2 levels of filtration rating are available. 5 µm µm/made to Order Easy to visually check white foreign matter Available with different bores on and OUT sides side < OUT side side port size OUT port size ø4 side > OUT side port size OUT port size side ø ø12 ø Made to Order OUT side OUT side Application examples Improvement of air quality for air blow Flexible mounting orientation Allow a sufficient margin of tube length when piping, in order to prevent twisting, tensile, moment loads, vibration or impact being applied to the tubes and filter body. 262

Filter Variations Flow rate under vacuum condition Flow rate under positive pressure In-line Air Filter For positive pressure For vacuum pressure Spacesaving Series AF to 77 to 54 AF Easy to install to the line to to ZFB AF to 35 to 35 Flexible mounting orientation F D H E F AD to ZFA Flow rate (positive pressure) conditions: Supply pressure.1 MPa, Differential pressure kpa 263

In-line Air Filter Series RoHS How to Order 5 4 B 5 7 3 4 5 6 7 B D E F Body size L/min L/min Body size Filtration area 75 mm 2 126 mm 2 Metric size ø4 ø ø12 ø5/32" ø1/4" ø5/16" ø3/8" 5 7 Inch size X1 X2 X3 X4 X5 X6 Option Nil None B With bracket Made to Order Refer to page 268 for details. Specifications Different diameters ( side < OUT side) Different diameters ( side > OUT side) Blue element Filtration: µm FKM/Oil free (Seal) Nylon Specifications Max. Operating Pressure and Operating Temperature Model Port size Metric size () Inch size Fluid Operating pressure Flow rate (Positive pressure) L/min Note) Flow rate (Vacuum pressure) L/min Proof pressure MPa Operating and ambient temperature range C Filtration µm Element replacement differential pressure MPa Filtration area mm 2 Applicable tubing material Weight g Internal capacity cm3 Total length mm Total width mm Bracket total length mm Case material ø4 ø5/32" 45 5 75.5 4.5 53.9 19. 23. ø1/4" ø1/4" 7 Air, Nitrogen kpa to 1. MPa 1 ø5/16" 25 7 1.5 to 6 5 (Filtration efficiency 95%).1 (Vacuum pressure kpa) 126 Nylon, Soft nylon, Polyurethane. 6. 68.4 23.6 27.3 Polycarbonate ø ø3/8" 8 25. 7. 79.7 ø12 35 Note) Flow rate (positive pressure)conditions: Supply pressure.1 MPa, Differential pressure kpa Max. operating pressure [MPa] 1..8.6.4.2. 4 5 6 Operating temperature [ C] 264

In-line Air Filter Series Flow Characteristics 53ø4 4 6 8 74 76 ø.1 MPa.3 MPa Flow rate [] 5 15 25 Flow rate [].7 MPa.1 MPa.3 MPa.5 MPa.1 MPa.3 MPa.7 MPa.5 MPa.7 MPa.5 MPa 54 75 77 ø12.1 MPa.3 MPa.5 MPa.7 MPa 5 15 Flow rate [].1 MPa.3 MPa.5 MPa.7 MPa 4 5 Flow rate [].1 MPa.3 MPa.5 MPa.7 MPa F D H E F AD 4 6 Flow rate [] 4 6 Flow rate [] 265

Construction Component Parts No. Description Material Quantity 1 2 3 4 5 Case Cover Element Seal Bracket PC ResinPBT Sintered resin HNBR ResinPBT 1 2 1 2 1 One-touch fittings w OUT Replacement Element Part No. Part no. Applicable filter model Element size Set description -EL-3 5 ø12 x x L Spare element: pcs. -EL-4 7 ø16 x ø12 x L25 Spare element: pcs. e q r t Element Replacement Procedure 1. Stop operation and reduce the filter s internal pressure to atmosphere. 2. Slide the lock mechanism in the direction of the arrow to release the lock. 3. Rotate the cover counterclockwise at least 9 degrees. 4. Pull the cover out of the case to remove the element. Remove dust and other debris remaining inside the case by blowing it out with air, etc. (Also, confirm that the O-ring is not damaged.) 5. Install a new element on cover and insert it into the case. 6. Align the raised part of the cover with the model no. display of the body, and push the cover to the end of the body and rotate it clockwise until it stops. 7. Set the lock mechanism and check that the cover is locked completely. Unlocked state Locked state Procedure 2 Rotating Procedure 3 Product no. display Procedure 7 Procedure 6 Case Element Cover Procedure 4 Protrusion on the cover Procedure 5 266

In-line Air Filter Series Dimensions 5 (ø4, ) (ø4, ) 33.4 ø19 53.9 18 23 F 4.5 6.4 15.7 13.5 24.7 ø23.6 7 (,, ø1/4", ø5/16") (,, ø1/4", ø5/16") 39.8 24 34 68.4 27.3 D H E 4.5 F 8.7.7 19.2 28.5 ø23.6 24 7 (ø, ø12, ø3/8") (ø, ø12, ø3/8") 39.8 AD 34 79.7 27.3 4.5 8.7 26.7 19.2 33.8 267

Made to Order Please contact SMC for detailed specifications, dimensions and delivery. 1 Different diameters ( side < OUT side) side applicable tubing O.D. (Metric size): ø4 OUT side applicable tubing O.D. (Metric size): 5 3 3 port ø4 OUT port side X1 -X1 side < OUT side Option Nil None B With bracket OUT side 3 Blue element -X3 Easy to recognize white foreign matter on the element by coloring the element. Standard product 4 Filtration: µm Standard product X3 X4 Blue element -X4 Filtration: µm 2 Different diameters ( side > OUT side) side applicable tubing O.D. (Metric size): to ø12 OUT side applicable tubing O.D. (Metric size): to ø 7 5 5 6 7 side ø ø12 OUT side ø X2 -X2 side > OUT side Option Nil None B With bracket 5 6 Seal material: FKM Oil free: Seal Standard product X5 Case material: Nylon Standard product X6 Case material: Nylon -X5 -X6 side OUT side 268

Specific Product Precautions 1 Be sure to read before handling. Refer to front matter 43 for Safety Instructions. For Vacuum Equipment Precautions, refer to Best Pneumatics No.4 and the Operation Manual. Please download it via our website, http://www.smcworld.com Caution Mounting 1. Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. 2. Maintenance space Allow sufficient space for maintenance and inspection. 3. Observe the tightening torque for screws. Tighten the screws to the recommended torque for mounting the product. 4. Connect tubing to the and OUT One-touch fittings in accordance with the precautions for Onetouch fittings. 1. Connect the piping after checking the arrow indication showing the flow direction on the body. If the piping is connected the other way around, it is not possible to seal the element. 2. Positive and negative pressures cannot be used together in the same circuit. 3. Allow a sufficient margin of tube length when piping, in order to prevent twisting, tensile, moment loads, vibration or impact being applied to the tubes and filter body. Maintenance 1. Perform maintenance inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction and damage of machinery or equipment may occur. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling, repair and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person. 3. Drain flushing Remove drainage regularly from the air filters, etc. 4. Removal of equipment, and supply/exhaust of compressed air When components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function. When machinery is restarted after remounting or replacement, confirm that the equipment is operating normally. Caution Maintenance 5. The performance of an ejector will deteriorate due to clogged suction filters and silencers. High flow filters should be used, especially in dusty locations. Vacuum release valve Speed controller for release flow adjustment If a filter is required on the release pressure side, a different filter should be prepared. Not possible to use vacuum pressure and positive pressure together in the same line. 6. When the element becomes clogged, stop operation and adjust the internal pressure of the filter to atmospheric pressure before replacing the element. 1. Element should be replaced in either of the two cases below. 1) When pressure drop reaches.1 MPa in a positive pressure or kpa in a vacuum pressure. 2) When the set values (flow rate, vacuum reaching time) change. 2. During disassembly and assembly, confirm that there are no scratches or damage, etc, on the O-ring. 3. Before using, confirm there is no leakage after replacing elements. Pad Vacuum pump Vacuum switch valve Air suction filter Vacuum pressure switch F D H E F AD 269

Specific Product Precautions 2 Be sure to read before handling. Refer to front matter 43 for Safety Instructions. For Vacuum Equipment Precautions, refer to Best Pneumatics No.4 and the Operation Manual. Please download it via our website, http://www.smcworld.com Recommended Piping Conditions 1. When connecting piping to the One-touch fitting, use pipe length with sufficient margin, in accordance with the piping conditions shown in Figure 1. Also, when using a tying band, etc., to bind the piping together, make sure that external force does not come to bear on the fitting. (see Figure 2) Tubing size ø4, 5/32" ø1/4", 5/16" ø ø3/8" ø12 Straight line Mounting pitch A Figure 1 Recommended piping Mounting pitch A Nylon tube Soft nylon tube Polyurethane tube 56 or more or more 26 or more 84 or more 39 or more 39 or more 89 or more 56 or more 57 or more 112 or more 58 or more 52 or more 14 or more 7 or more 69 or more 134 or more 76 or more 69 or more 168 or more 82 or more 88 or more Recommended No good Figure 2 When using a tying band to bind the piping together Unit: mm Straight-line pipe length or more or more 32 or more 4 or more 5 or more 48 or more 6 or more Handling of One-touch Fittings Caution 1. Tubing attachment/detachment for One-touch fittings 1) Installing of tubing (1) Use tubing with no flaws on its periphery and cut it off at a right angle. When cutting the tubing, use a tube cutter, TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. If cutting is done with tools other than tube cutters, the tubing may be cut diagonally or become flattened, etc. This can make a secure installation impossible, and cause problems such as the tubing pulling out after installation or air leakage. Allow some extra length in the tubing. (2) The outside diameter of the polyurethane tubing swells when internal pressure is applied to it. Therefore, it may not be possible that the tubing can be re-inserted into the One-touch fitting. Confirm the tubing outside diameter, and when the accuracy of the outside diameter is +.15 or larger, re-insert the tubing into the One-touch fitting without cutting it. When the tubing is re-inserted into the One-touch fitting, confirm that the tubing goes through the release button smoothly. (3) Grasp the tubing and push it in slowly, inserting it securely all the way into the fitting. (4) After inserting the tubing, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, this can cause problems such as air leakage or the tubing pulling out. 2) Removal of tubing (1) Push in the release button sufficiently. When doing this, push the collar evenly. (2) Pull out the tubing while holding down the release button so that it does not come out. If the release button is not pressed down sufficiently, there will be increased bite on the tubing and it will become more difficult to pull it out. (3) When the removed tubing is to be used again, cut off the portion which has been chewed before reusing it. If the chewed portion of the tubing is used as it is, this can cause trouble such as air leakage or difficulty in removing the tubing. 2. Do not install the SMC s KQ One-touch fitting series with a metal rod into the 5 series fittings. The metal rod will not be held and the fitting will shoot out. 27

Specific Product Precautions 3 Be sure to read before handling. Refer to front matter 43 for Safety Instructions. For Vacuum Equipment Precautions, refer to Best Pneumatics No.4 and the Operation Manual. Please download it via our website, http://www.smcworld.com Caution Other Tube Brands 1. When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; 1) Nylon tubing : Within ±.1 mm 2) Soft nylon tubing : Within ±.1 mm 3) Polyurethane tubing : Within +.15 mm, Within.2 mm Do not use tubing which does not meet these outside diameter tolerances. It may not be possible to connect them, or they may cause other trouble, such as air leakage or the tube pulling out after connection. 2. Connecting products with metal rods After connecting the products with metal rods (Series KC, etc.) to the One-touch fittings, do not use tubes, resin plugs or reducers, etc. These may come off the fittings. Design 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 2. Modification prohibited Do not make any modifications, including additional machining. It may cause human injury and/or an accident and will void the warranty. Air Supply 1. Type of fluids Please consult with SMC when using the product in applications other than compressed air. 2. When there is a large amount of drainage. Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment. An air dryer or water droplet separator should be installed upstream from filters. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the condensate will overflow and allow it to enter the compressed air lines. This will cause a malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, installation of a drain bowl with an auto drain option is recommended. Refer to SMC Air Preparation System for further details on compressed air quality. 4. Use clean air. Do not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction. Operating Environment 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in a place subject to heavy vibration and/or shock. 3. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 4. The valve should not be exposed to prolonged sunlight. Use a protective cover. 5. Remove any sources of excessive heat. 6. In locations where there is contact with spatter from water, oil, solder, etc., take suitable protective measures. F D H E F AD 271