HEALTH PHYSICS LABORATORY Report for 2003-2004 Activities: 5.9 TL dosimetry in medicin and radiation protection 5.10 Radiation protection 6.2 Development of therapeutic stand for proton therapy
Health Physics Laboratory 2004: 16 persons RESEARCH RADIATION PROTECTION OFFICER LABORATORY FOR CALIBRATION OF THE DOSEMETERS LABORATORY FOR PERSONNAL AND ENVIRONMENTAL DOSIMETRY
2003 KBN parameters: 2004
International projects: person title program total duration Paweł Olko Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology (MAESTRO) 6PR 1 200 000 2004-2009 Barbara Marczewska Diamond Research on Interfaces for Versatile Electronics (DRIVE) 6PR Marie Curie RTN Action 760 000 2004-2008 Paweł Olko Assessment of Environmental Risk for Use of Radioactively Contaminated Industrial Tailings (INTAILRISK) 6PR 20 000 2004-2007 Total budget: 1 980 000 PLN
KBN grants 2003-2008 Person Title Project number budget zł Duration B. Marczewska Development of the Thermoluminescent Method of Dose Distribution Measurement Using the CCD Camera and Large-are Detectors Based on LiF and CVD Diamonds for Radio- and Brachytherapy 4 T11E 011 23 136 000 2003-2005 P. Bilski Development of the Method of Dose Equivalent Measurement in Mixed Radiation Fields Using Thermoluminescent Detectors 4 T10C 038 24 118 000 2003-2005 M. Budzanowski A Method of Identification of Static X-ray Radiation Exposure of Thermoluminescent Dosemeter Used in Radiation Protection 3 P05D 059 25 110 700 2003-2005 P. Olko Ocena dozymetrycznych i mikrodozymetrycznych parametrów wiązki protonowej o energii 60 MeV stosowanej do celów klinicznych 3 T11E 036 26 170 000 2004-2006 SPUB: 780 000 PLN SPUB: 780 000 PLN Total budget: 534 700 PLN
MAESTRO Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology - integrated project - 2004-2008 - 2- and 3-D dosimetry - 20 partners - budget 7 ml Euro
MAESTRO WP3.1: Diamond detectors dr B. Marczewska mgr T. Nowak 1.80E-008 1.60E-008 1.40E-008 X-rays, 250kV, 10mA natural diamond C2 SYN4a ionisation chamber 6 I (det), A 1.20E-008 1.00E-008 8.00E-009 6.00E-009 4.00E-009 2.00E-009 0.00E+000 Detektor diamentowy 2 0 0 100 200 300 400 500 time, s 4 D, Gy/min
MAESTRO WP3.6: 2-D planar TL dosimetry - prototype of TL reader with CCD camera - TL detectors of 30cm 2 mgr Ł. Czopyk LiF polymer mixed detectors: Thin and flexible, Diameter upto 70m m, Prototype ofreader and detector up to 200m m.
DISTINGUSIHING BETWEEN STATIC AND DYNAMIC EXPOSURE dr M. Budzanowski Dyn 28 Static kev amic V Xexposure rays, 20 mgy, Al Pb Cu filter r Standard New
Project MATROSHKA Measurement of organ radiation doses with a human phantom - over 3000 TLDs from IFJ Kraków launched in January 2004 planned return October 2005 dr P. Bilski organized by European Space Agency
Radiation protection at the IFJ 2004: mgr inż. K. Zbroja mgr inż. T. Nowak - training for 14 newly hired workers and students -individual dosimetric service for: 35 workers (A) and 138 workers (B) - 51 control points at the IFJ - 46 dosimetric controls, 42 - cyclotron
Laboratory for Personnal and Environmental Dosimetry, LADIS LADIS team No of dosmeters [pcs] 5000 4500 4000 3500 3000 2500 2000 1500 1000 4375 Total: 5425 dosemeters 31.12.2004 500 0 713 359 73 Individual Envrironment Finger-ring ALBEDO Dosemeter type Incomes 2004: 316 000,- zł (in 2003 109 000,- zł)
Laboratory for Calibration of Radiation Protection Instruments, LWPD 2004 - calibration of 800 radiation protection instruments 900 800 700 dr P. Bilski dr B. Marczewska calibrations 600 500 400 300 200 I. Lipeńska 100 0 1999 2000 2001 2002 2003 2004 2005 year mgr inż. mgr K. Zbroja T. Horwacik incomes IFJ: 150,000 PLN/year
Development of the proton therapy stand for eye melanoma treatment New equipment mgr T. Nowak dr Janusz Swakoń Program for therapy planning - EYEPLAN T. Kajdrowicz
PhD students: mgr inż. Renata Kopeć TL method in medical application mgr inż. Marta Ptaszkiewicz Dosimetry of ionising radiation in mixed field using TLD mgr inż. Tomasz Horwacik The use of track detectors in detremination dosimetric parameters of charged partcile fields mgr inż. Monika Puchalska Estimation of cosmic dose radiation for cosmonauts during the extravehicular activity mgr inż. Łukasz Czopyk Microdosimetric modelling of planar TLD detectors for heavy ionizing radiation + 5 MSc students/year
Cooperation Health Physics Laboratory: - mgr J. Bogacz - TL + radon - dr A. Czermak - proton therapy - mgr inż. J. Kotuła - proton therapy - dr K. Kozak - radon - dr W.J. Mietelski - DU (Serbia) - dr B. Ochab - TL - dr B. Petelenz - dosimetry - dr B. Rajchel - diamonds - mgr inż. E. Tałach - proton therapy - doc. U. Woźnicka - Boron Neutron Capture Therapy
Cooperation 2003-2004: Sacley, France, Program Polonium Univ. Diepenback, Belgium Novosybirsk, Russia DLR, Kolonia, Germany Dubna, Russia KAERI, Korea IAEA AGH Technical Univ. Warsaw IEA Świerk Warsaw CVD diamond CVD diamond HPHT diamond cosmic radiadion dosimetry proton therapy ultra sensitive detectors calibration proton therapy proton therapy BNCT
Health Physics Laboratory Conclusions: - 2 accredited laboratories - 4 KBN grants till 2006-2 6 PR grants till 2008