Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004]



Similar documents
Building Codes Update: The 2009 International Fire Code and the Apartment Industry

BUILDING PERMIT SPECIFICATIONS

IECC Compliance Guide for Homes in Virginia


Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

The replacement or modification of existing windows shall comply with the following requirements:

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

2009 IECC Update. Scope. Content. International Energy Conservation Code

New York City Department of Buildings

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

City of Riverside Building & Safety Division Phone: (951)

Current as of 11/10/08 1 of 1

Building Control Guidance Note

Automatic Door Selection Guide

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

MEANS OF EGRESS CHAPTER 10

Excerpts from the Canadian National Building Code (NBC)

Building Code Clarifications - 7. Fire Resistance

FIRE-RESISTANCE-RATED CONSTRUCTION

Code Requirements for Existing Buildings

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Walking and Working Surface Checklist:

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

FIRE-RESISTANCE-RATED CONSTRUCTION

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

MEANS OF EGRESS CHAPTER 10

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

City of Douglas Commercial Building Permit Site Application

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Healthcare Engineering. Code Summary Report

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Number of Sides Required to Have a Handrail

CHAPTER 4 VENTILATION

MEANS OF EGRESS CHAPTER 10

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

This notice sets forth interim guidance, pending the issuance of regulations,

Comparison of Standard and the 2012 IECC with Respect to Commercial Buildings

BUILDING SAFETY UNIT

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

Charter Township of Shelby Harry Reese Building Director

Indiana Building Rehabilitation Standard

New York City Department of Buildings

2014 British Columbia Building Code Changes

MEANS OF EGRESS CHAPTER 10

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Certification: Building Plans Examiner. Exam ID: B3

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

INDIANA COMMERCAL ENERGY CODE BASELINE STUDY

Continuous Insulation Using Polyiso Wall Sheathing

Heating Load Calculation

Single Family Residential Basement Finish

FIRE SAFETY INSPECTION REPORT

Commercial Building Valuation Report

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

- 5 - Table1. Maximum Compartment Volumes

Compliance Software COMcheck 2 and ENVSTD 3

Civil Engineering and Architecture (CEA) Detailed Outline

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

CHILD CARE CENTER INFORMATION SHEET

THERMAL LOSSES Thermal Losses Calculations

Fire Alarm Systems Requirements by Occupancy Type

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

How To Protect A Swimming Pool

Guidance on loft conversions in two-storey houses

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

2012 IECC Commercial Electrical Power and Lighting Systems July 2011

MEANS OF EGRESS CHAPTER 10

FIRE AND SMOKE PROTECTION FEATURES

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

A Code Review for Emergency Generators and Indoor Use of Portable Generators

REQUIREMENT 3. Usable Doors

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Classroom Door Security & Locking Hardware

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Overview of Hotel Fire Safety Requirements

Control filling, grading, dredging, and other development which may increase erosion or flood damage; and

Transcription:

Vestibule Case Study [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14

The primary intent behind the requirement for a vestibule is to reduce infiltration into a space that includes doors with high volume of pedestrian traffic. These doors are typically used by the general public to access public areas and have a higher usage rate than a door classified for personnel use. Vestibules reduce the infiltration losses (or gains) from wind and stack effect by creating an air lock entry. The stack effect caused by naturally occurring warm air rising, is greater in taller buildings than in low rise construction but under the provisions of the 2003 and 2006 IECC no allowance is made for building height or number of stories. Wind exposure is dependant on the orientation of the building and greater infiltration driver in low-rise commercial buildings verses stack effect. When Is A Vestibule Required? Vestibules are required in Chapter 8 of the 2003 IECC (Section 802.3.6), Chapter 5 of the 2006 IECC (Section 502.4.6), ANSI/ASHRAE/IESNA Standard 90.1-2001 (Section 5.5.3.4), and Standard 90.1-2004 (Section 5.4.3.4). Essentially a vestibule is required on the primary entrance doors leading from spaces in a building greater than or equal to 3000 ft². Both the IECC and 90.1 have similar requirements for when a vestibule is required and the configuration of the vestibule. However, 90.1-2001 and 90.1-2004 exempt vestibules in buildings less than four stories. Page 2 of 14

A lobby surrounded by floor-to-ceiling partitions, a roof/ceiling assembly and floor assembly could be considered a space. The lobby walls can contain operable windows and doors that isolate the space from the adjoining spaces or the exterior. The IECC, 90.1-2001 and 90.1-2004 [1] require vestibules for "spaces" that are 3000 ft² or greater. This is not the building area but a space within a building. For example, an entrance to a 2000 ft² retail store with a 1,500 ft² storage area, closed off by doors, would not require a vestibule. However, a 4000 ft² retail space with an entrance door to a sales area of 3000 ft² would be required to have a vestibule. In some circumstances, it is difficult to define where one space ends and another begins for the purposes of calculating whether the size of the space with an outside entrance door requires a vestibule. An example of this is a 2000 ft² lobby with one wall substantially open to a larger adjacent lounge. In such a case, the two areas should probably be considered a single space, and a vestibule should be required. The following definition is offered by 90.1-2001 and 90.1-2004 and provides some guidance: Space. The following definition is offered by 90.1-2001 and 90.1-2004: "A volume substantially surrounded by solid surfaces such as walls, floors, roofs and openable devices such as doors and operable windows." Page 3 of 14

The word "substantially" must be interpreted for the purpose of determining the need for a vestibule. Unfortunately, the IECC has no such definition. Doors. Based on the exceptions that apply to the IECC, 90.1-2001 Standard and Users Manual, and 90.1-2004 Standard and Users Manual, the doors that are affected by this requirement are doors intended as entrances to the building that receive pedestrian traffic from both the general public and building occupants. For example, the doors leading into a public lobby would be required to have a vestibule where doors leading to service areas, mechanical rooms, electrical rooms or exits from fire stairways would be exempt. Personnel doors adjacent to doors used to facilitate vehicular movement or material handling are exempt. For example, a door adjacent to a loading dock would be exempt. Page 4 of 14

Page 5 of 14

If the building has more than one entrance into a space 3000 ft² or greater, each of the doors must have a vestibule. For example, a gas station/convenience store may include two entrances into the open store area. If the space is 3000 ft² or greater each of the entrances would be required to have a vestibule. Page 6 of 14

Page 7 of 14

The 2003 and 2006 IECC, and the 90.1-2001 and 90.1-2004 provide an exemption from the vestibule requirement in entrances that use revolving doors as they provide adequate protection against infiltration into the space. If a revolving door is used in place of a vestibule, the 2003 and 2006 IBC Section 1008.1.3.1 require that a side-hinged swinging door must also be installed within 10 feet of the revolving door. Doors are also required to have self closing devices. A door closure system on a swinging door would meet the intent of the requirement as would a power operated door -- such as a door with a motion-actuated mechanism to open the door upon the approach of a person. Page 8 of 14

Vestibule Dimensions. The IECC provides guidance to determine the minimum depth of the vestibule by requiring that the vestibule must be designed so that it is not necessary to open doors leading into and out of the vestibule at the same time in order to pass through. This requirement allows a person to enter the vestibule, have the door shut behind them and then exit the vestibule while maintaining an air lock to reduce infiltration. The requirements in 90.1-2001 and 90.1-2004 are identical except that a minimum of seven feet is also required between the doors leading out of the vestibule when the doors are in the closed position. Page 9 of 14

ICC/ANSI A117.1-98 Accessible and Usable Buildings and Facilities (A117.1-98), referenced in the 2003 IBC (see Code Reference section), provides a requirement for minimum distances between two doors in a series, such as in a vestibule configuration. A117.1-98 requires that the distance between the two hinged or pivoted doors that are in series must have a minimum distance of 48" between them plus the width of the door swinging into the space. For example, if the door swing into the space is 34" the minimum distance that would be required would be 82". In addition to the minimum depth of the vestibule, A117.1-98 also places requirements on the minimum width that a vestibule can be. A minimum of a 60" turning diameter is required to be able to turn a wheelchair in the vestibule. Compliance with the Code The first step in determining compliance with the envelope requirements of the IECC is to determine the boundary of the building envelope. The vestibule requirement specifies that a door that separates conditioned space from the exterior is to have a vestibule. Because the door is specified as an exterior door, the wall assembly that contains the door is considered part of the building envelope and therefore must comply with the IECC. Page 10 of 14

Two common vestibule configurations are provided as examples on defining the building envelope. A common vestibule installation example is to have the vestibule protruding from the exterior of the building to protect the exterior doors. In this example the items associated with the red walls are considered to be part of the building envelope and therefore must comply with the IECC. Because the vestibule now forms an unconditioned space, the wall, window and door assemblies that separate the conditioned space from the vestibule can meet the interior wall requirement. The walls must meet the R-value requirements based on construction type. In addition, the windows and doors must meet the maximum U-factor and SHGC requirements based on the 0 10% glazing percentage. The glazing, doors and opaque surfaces associated with the vestibule itself are not covered under the provisions of the IECC. Page 11 of 14

Another example of a vestibule configuration is to have the vestibule come into the conditioned space instead of protruding from the building. In this scenario, the walls and glazing assemblies that surround the vestibule (see red assemblies) must meet the interior wall requirements (Chapter 8 of the 2003 IECC and Chapter 5 of the 2006 IECC). The door and wall assemblies that form the wall between the vestibule and the exterior (see grey assemblies) would be exempt. Compliance with the International Building Code In addition to meeting the requirements of the IECC or 90.1-2001/90.1-2004, vestibules must also be designed to meet the requirements of the International Building Code for means of egress and accessibility. Code Citations* IECC 2003 Section 802.3.6 and IECC 2006 Section 502.4.6 Vestibules A door that separates conditioned space from the exterior shall be protected with an enclosed vestibule, with all doors opening into and out of the vestibule equipped with self-closing devices. Vestibules shall be designed so that in passing through the vestibule it is not necessary for the interior and exterior doors to open at the same time. Exceptions: 1. Buildings in Climate Zones 1a through 4b as indicated in Table 302.1 (See Energy Code Climate Zones ) [2003 IECC]; Buildings in Climate Zones 1 and 2 as indicated in Table 301.1 [2006 Page 12 of 14

IECC]. 2. Doors not intended to be used as a building entrance door, such as doors to mechanical or electrical equipment rooms. 3. Doors opening directly from a guestroom or dwelling unit [2003 IECC]; Doors opening directly from a sleeping unit or dwelling unit [2006 IECC]. 4. Doors that open directly from a space less than 3,000 square feet (298 m²) in area. 5. Revolving doors. 6. Doors used primarily to facilitate vehicular movement or material handling and adjacent personnel doors. ANSI/ASHRAE/IESNA Standard 90.1-2001 Section 5.5.3.4 and 90.1-2004 Section 5.4.3.4 Vestibules A door that separates conditioned space from the exterior shall be protected with an enclosed vestibule, with all doors opening into and out of the vestibule equipped with self-closing devices. Vestibules shall be designed so that in passing through the vestibule it is not necessary for the interior and exterior doors to open at the same time. Interior and exterior doors shall have a minimum distance between them of not less than 7 ft when in the closed position. Exceptions: 1. Doors in buildings in climates that have less than 1800 HDD65 [90.1-2001]; Buildings in Climate Zones 1 and 2 [90.1-2004]. 2. Doors in buildings less than four stories above grade 3. Doors not intended to be used as a building entrance door, such as mechanical or electrical equipment rooms 4. Doors opening directly from a dwelling unit 5. Doors that open directly from a space less than 3000 ft² in area 6. Doors in building entrances with revolving doors 7. Doors used primarily to facilitate vehicular movement or material handling and adjacent personnel doors. 2003 and 2006 IBC Section 1203.4.1.1 Adjoining spaces. Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the opening to the adjoining rooms shall be unobstructed and shall have an area not less than 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.3 m²). The minimum openable area to the outdoors shall be based on the total floor area being ventilated. ICC/ANSI A117.1-2003 Two Doors In Series Distance between two hinged or pivoted doors in series shall be 48 inches minimum plus the width of any door swinging into the space. The space between the doors shall provide a turning space complying with Section 304. Page 13 of 14

2003 and 2006 IBC Section 1008.1.3.1 Revolving doors Revolving doors shall comply with the following: Each revolving door shall have a side-hinged swinging door which complies with Section 1008.1 in the same wall and within 10 feet (3048 mm) of the revolving door. 2003 IBC Section 1023.1 and 2006 IBC Section 1024.1 General Exception 2. A maximum of 50 percent of the number and capacity of the exit enclosures is permitted through a vestibule provided all of the following are met: 1. The entire area of the vestibule is separated from the areas below by construction conforming to the fire-resistance rating for the exit enclosure. 2. The depth from the exterior of the building is not greater than 10 feet (3048 mm) and the length is not greater than 30 feet (9144 mm). 3. The area is separated from the remainder of the level of exit discharge by construction providing protection at least the equivalent of approved wired glass in steel frames. 4. The area is used only for means of egress and exits directly to the outside. Note: [1] ASHRAE 90.1-2001 and 90.1-2004 have an exemption for the number of floors in the building. See Section 5.5.3.4 and Section 5.4.3.4. * 2003 IECC Reference and link *Copyright, 2003, International Code Council, Inc. Falls Church, Virginia. Reproduced with permission. All rights reserved. 2003 International Energy Conservation Code 2003 International Energy Conservation Code ; 2006 IECC Reference and link *Copyright, 2006, International Code Council, Inc. Falls Church, Virginia. All rights reserved. 2006 International Energy Conservation Code. 2006 International Energy Conservation Code ; 2003 IECC Reference and link *Copyright, 2003, International Code Council, Inc. Falls Church, Virginia. Reproduced with permission. All rights reserved. 2003 International Energy Conservation Code 2003 International Building Code ; 2006 IECC Reference and link *Copyright, 2006, International Code Council, Inc. Falls Church, Virginia. All rights reserved. 2006 International Energy Conservation Code. 2006 International Building Code ; ASHRAE 90.1-2001 Reference and link Copyright, 2001, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA. ASHRAE Standard 90.1-2001. Reproduced with permission. All rights reserved. ; ASHRAE 90.1-2004 Reference and link Copyright, 2004, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA. ASHRAE Standard 90.1-2004. Reproduced with permission. All rights reserved.. Page 14 of 14