HIGH PERFORMANCE FLOW SENSORS Cable 7.6 m (25') FP-2541 Starts at $ 490 Rugged 316 Stainless Steel Construction Flow Rates as Low as 0.3 fps Installs in a Variety of Pipe Sizes No Magnets in Process Fluid Hot-Tap Version Removable Without Shutdown Uses Standard Pipe Connections The FP-2541 and FP-3-1500 Series offer the added strength and corrosion resistance of stainless steel for applications requiring low velocity measurement. Unique internal circuitry eliminates the need for magnets in the process fluid, enabling lower flow measurement while maintaining the advantages of insertion-type sensor design. The sensor s unique rotor/bearing design offers low flow measuring capability with increased reliability. FP-3-1500-2B Hot-Tap 64 (2.5) 457 (18) SPECIFICATIONS Output Signal: Open collector, sinking Output Frequency: 15 Hz per fps Operating Range: 0.3 to 20 fps Pressure/Temperature: With standard FKM O-rings: 250 psi @ 82 C (180 F) Power Requirements: 5 to 24 Vdc Pipe Size Range: FP-2541: 1.5 to 24" FP-3-1500-2B: 1.5 to 36" Repeatability: ±0.5% of full range Linearity: ±1% of full range MATERIALS Sensor Fitting: 316SS O-rings: FKM Rotor: CD4MCu Rotor Bearings: PEEK TM Cable Type: Twisted pair with foil shield Cable Length: 7.6 m (25') 305 m (1000') max : High Performance Flow Sensor 7.5 m (25') Integral cable Adjustable length O-ring seal (1) 64 (2.5) Dimensions: mm (in) 127 (5.0) Sensor fitting: 1.5 in. NPT or ISO 7/1-R 1.5 thread 24 (0.94) FP-2541 flow sensor, $490, shown with 152 mm (6") installation ruler, included. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model Number) Model No. Price Description FP-2541 $490 High performance flow sensor with 1.5 NPT thread F O-ring seals (2) Adjustable length Dimensions: mm (in) Accessories Bleed valve Model No. Price Description Sensor fitting: FP-3-1500-302 $440 Hot-tap installation tool 1.5 in. NPT or FP-3-1500-2B 735 Hot-tap flow sensor with 1.5 NPT Compatible Meters: ISO 7/1-R 1.5 thread DPF700 (page M-5), thread FP-3-2540-321 70 Replacement rotor and pin for FPM-5500 (page F-43), units with serial numbers with A FPM-9020A (page F-42) 24 (0.94) Comes complete with 152 mm (6") installation ruler and operator s manual Ordering Examples: FP-2541, high performance flow sensor with 1.5 NPT thread, $490. F-38
MEASUREMENT SYSTEMS NUFLO Liquid Turbine Flowmeters Accurate Flow Measurement In 1957, this flowmeter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of the oil field. Over the years, it has earned an unsurpassed reputation for withstanding severe punishment while maintaining operational and measurement integrity. Today, it remains a bestseller among Cameron s NuFlo liquid measurement products. NuFlo turbine flowmeters indicate flow rate and measure total throughput of a liquid line. As liquid flows through the meter and over the rotor, the rotor turns at a speed that is directly proportional to the flow rate. A magnetic pickup senses the rotor blades as they pass and generates an electrical (sine wave) signal. These electrical pulses are then transmitted to the flow measurement readout equipment.
First Class Design Delivers First Class Performance 4 2 1 3 5 6 8 7 1. Permanent conduit connection is standard. 2. ROTOR is pitched and pre-calibrated to determine accuracy. 3. END CONNECTIONS available, flanged or threaded, standard or special. 4. FLOW VANES increase performance at low rates. 5. FLOW VANE HUB supports rotor assembly. 6. ROTOR SHAFT, BEARINGS, AND THRUST BALL are made of tungsten carbide for long service without lubrication other than by the liquid being measured. 7. RETAINING RINGS make disassembly easy. 8. FLOWMETER BODY is sturdy, one-piece construction, precision finished. Applications Cameron offers turbine flowmeters in a variety of end connections and accuracy levels. Typical applications are: Water-injection measurement Heater treaters Test and production separators Disposal wells CO2 injection Steam generator fuel and feed water Metering liquid fertilizer Water, fuel, and chemical measurement in plant settings Chemical tank loading and unloading Measuring liquid propane Insitu mining and leaching Accuracy NuFlo meters are classified as Standard Grade and Industrial Grade, based on the linearity of the meter. The Standard Grade meter provides a cost-effective measurement solution for applications where higher accuracy is not required. For higher accuracy applications, an Industrial Grade meter can be used. Such meters can achieve even greater accuracy if the range of the flow through the meter is specified. Meter Grade Linearity Repeatability Standard* ± 1% of reading ± 0.05% Industrial* ± 0.5% of reading ± 0.02% Enhanced accuracy Consult factory Consult factory * For 3/8 in. meters, linearity is ± 2% of reading (standard) and ± 1% of reading (industrial). Temperature Range (magnetic pickup) Temperature Range Flowmeter Size Standard -67 to 225 F -55 to 107 C 3/8 in. through 3/4 in. Standard -67 to 250 F -55 to 121 C 7/8 in. through 8 in. Medium -67 to 450 F -55 to 232 C all sizes Note: Consult Cameron's Measurement Systems division for any use of turbine flowmeters above 450 F (232 C). 2
WMX-SERIES Flanged Magmeter 9 001:2008 ISO CERTIFIED COMPANY APPLICATIONS Municipal water/wastewater Industrial water/wastewater Cooling tower water treatment Well usage reporting FEATURES Simple and economical as a mechanical meter No moving parts Built-in pulse output Minimal straight pipe required Continuous battery or external power Data logger compatible Telemetry-ready WMX101 WMX104 Unobstructed Flow GENERAL INFORMATION The WMX-Series are flanged electromagnetic flowmeters for use in 4 to 10 pipe in municipal or industrial water and wastewater applications where propeller meters have typically been used in the past. Because the WMX has no moving parts and has electrodes designed to discourage fouling, this magmeter performs well and requires much less frequent maintenance in applications where debris would impede propeller meters. There is no rotor to stop turning or bearings to wear out. Minimal straight pipe requirements allow WMX-Series meters to be used in piping configurations where there is little space between the meter and an elbow. In chemical injection applications, the meter should be placed upstream of the injection line or far enough downstream for thorough mixing to occur before the meter. Rate and total indication are standard on both models. Units are customer-selected and factory-set. No set-up is required. The WMX101 is externally powered with 7-32 Vdc at 30 ma max (see NOTE in Specifications). Two Lithium 3.6V AA batteries provide auxiliary power during power failures, allowing the meter to continue recording flow rate and total without interruption for the duration of the outage. Where external power loss is infrequent, battery life should exceed 10 years. The 20-foot power cable also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. High frequency pulse rate (required for use with 4-20 ma converters) is standard; additional pulse rates are optional. The WMX104 is a battery-operated unit for use when pulse output is not required. The Lithium 3.6V D batteries are replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. An optional input/ output cable can be installed post-factory if needed for changing applications.
WMX-SERIES Flanged Magmeter FEATURES Rate and total indicator Powder-coated diecast-aluminum electronics housing Cross-drilled screws (2) for tamper-evidence Tamper-evident security seal Internal Data Logger (Optional) Power/Output cable port access, tamper-sealed (NOTE: WMX101 comes with standard 20 cable installed) Equalization lug Welded steel epoxy-coated flow tube 316SS electrodes Dual durometer rubber liner Flanges, ANSI 150 lb. drilling SPECIFICATIONS* Pipe Sizes Fittings Pressure Temperature Accuracy Operating Non-Operating 4, 6, 8, 10 ANSI 150 lb. drilling 150 psi (10.3 bar) working pressure 10 to 130 F (-12 to 54 C) -40 to 158 F (-40 to 70 C) +/- 1% of reading for flow between 10% to 100% of max flow Materials Display Power Pulse Output Conductivity Body Liner Electronics Housing Electrodes Digits Units Empty Pipe Detection Environmental Signal Pulse Rates High Frequency (pulse/gal) +/- 2% of reading for flow from cutoff to 10% of max flow Welded steel, epoxy-coated Dual durometer rubber Diecast aluminum, powder-coated 316 stainless steel Rate 5 8 Gallon/Minute, Liter/Minute, Liter/Second, Gallon, Gallon x 1000, Liter, Liter x 1000, Mega Liter, Cubic Feet/Minute, Cubic Meter/Hour, Cubic Meters, Cubic Meter x 1000, Cubic Feet, Million Gallon/Day, Mega Liter/Day Cubic Feet x 1000 WMX101: 7-32 Vdc at 30 ma max, with auxiliary battery for continuous operation during power failures NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation Total WMX104: 2 Lithium 3.6V D batteries, replaceable, 1 year life under continuous use. WMX101: Current sinking pulse, opto-isolated, 30 Vdc at 10 ma max WMX104: Pulse output available only with addition of post-factory output cable High Frequency (default); 10 units/pulse; 100 units/pulse; 1000 units/pulse 4 6 8 10 16.362 6.307 3.344 2.150 >20 microsiemens/cm Hardware/software, conductivity-based NEMA 4X Standard *Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).
s Operating Manual Edition 01/2007 - Revision 08 SITRANS F M Electromagnetic water meter type MAG 8000 [ ] Technical Documentation (handbooks, instructions, manuals etc.) for the complete product range SITRANS F can be found on the internet/intranet via the following link: English: http://www4.ad.siemens.de/ww/view/en/10806951/133300 Order no.: FDK:521H1193 SFIDK.PS.026.D8.02 *083R9174*