DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF BENFOTIAMINE IN BULK AND DOSAGE FORM

Similar documents
Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

PVV Satyanaryana et al., IJSID, 2012, 2 (1), International Journal of Science Innovations and Discoveries

A NEW METHOD DEVELOPMENT AND VALIDATION FOR ANALYSIS OF RIVAROXABAN IN FORMULATION BY RP HPLC

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

High performance thin layer chromatographic method for estimation of deflazacort in tablet

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

Research Article. Development and validation of a HPLC analytical assay method for dapoxetine tablets: A medicine for premature ejaculation

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

International Journal of Pharma and Bio Sciences V1(2)2010

Journal of Chemical and Pharmaceutical Research

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHIC METHOD FOR DETERMINATION OF TADALAFIL IN TABLET DOSAGE FORM

Guidance for Industry

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

UV-VIS SPECTROPHOTOMETRIC METHOD FOR ESTIMATION OF GABAPENTIN AND METHYLCOBALAMIN IN BULK AND TABLET

Research Article. Stress study and estimation of a potent anticoagulant drug rivaroxaban by a validated HPLC method: Technology transfer to UPLC

By T.Sudha, T.Raghupathi

SUCRALOSE. White to off-white, practically odourless crystalline powder

Analytical Method Development and Validation of Caffeine in Tablet Dosage Form By Using UV- Spectroscopy

Scholars Research Library. A validated RP-HPLC method for estimation of Rivastigmine in pharmaceutical formulations

ERDOSTEINE - MONOGRAPH.

Development and Validation of RP-HPLC Method for the determination of Methylphenidate Hydrochloride in API

Analytical Test Report

Analytical Test Method Validation Report Template

UV Spectrophotometric estimation of Paracetamol and Lornoxicam in Bulk drug and Tablet dosage form using Multiwavelength

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Quantitative estimation of gallic acid and tannic acid in bhuvnesvara vati by RP-HPLC

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Venkata S Rao Somisetty 1 *, D Dhachinamoorthi 1, S A Rahaman 2, CH M M Prasada Rao 1

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Hiral N. Davea, Ashlesha G. Makwanab,*, and Bhanubhai N. Suhagiac

Analysis of Various Vitamins in Multivitamin Tablets

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Photolytic-Thermal Degradation Study And Method Development Of Rivaroxaban By RP-HPLC

International Journal of Research and Reviews in Pharmacy and Applied science.

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Journal of Chemical and Pharmaceutical Research, 2012, 4(7): Research Article

Tamsulosin Hydrochloride Capsules

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Journal of Chemical and Pharmaceutical Research

A practical and novel standard addition strategy to screen. pharmacodynamic components in traditional Chinese medicine using

Overview. Purpose. Methods. Results

Received: 19 Jun2010, Revised and Accepted: 20 July 2010

Rao, et al., Int J Res Pharm Sci 2015, 5(2) ; Available online at Research Article

Determination of Caffeine in Beverages HPLC-1

Vitamin C quantification using reversed-phase ion-pairing HPLC

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

How To Test For Contamination In Large Volume Water

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

The Theory of HPLC. Gradient HPLC

Quality by Design Approach for the Separation of Naproxcinod and its Related Substances by Fused Core Particle Technology Column

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

ETHYL LAUROYL ARGINATE

A Complete Solution for Method Linearity in HPLC and UHPLC

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Determination of Letrozole in Tablet Formulations by Reversed Phase High Performance Liquid Chromatography

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

ß-CYCLODEXTRIN SYNONYMS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Purification of reaction mixtures using flash chromatography.

Dissolved and precipitated oxalate

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CORESTA RECOMMENDED METHOD Nº 80

Determination of caffeine and vitamin B6 in energy drinks by high-performance liquid chromatography (HPLC)

Spectrophotometric Determination And Validation Of Acyclovir In Tablet Dosage Form

Liquid Chromatographic Method for the estimation of Donepezil Hydrochloride in a Pharmaceutical Formulation

Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Estimation and Stress Study of a Potent Anticoagulant Drug Rivaroxaban by a Validated HPLC Method

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

+++#,# & %!"#$%& '"#()*

RP-HPLC-PDA method development and validation for the analysis of Tadalafil in bulk, pharmaceutical dosage forms and in-vitro dissolution samples

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

ORIENTAL JOURNAL OF CHEMISTRY An International Open Free Access, Peer Reviewed Research Journal.

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Assay Development and Method Validation Essentials

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Implementing New USP Chapters for Analytical Method Validation

DEVELOPMENT AND VALIDATION OF A STABILITY INDICATING HPLC METHOD FOR ANALYSIS OF PEFLOXACIN IN BULK DRUG AND TABLET DOSAGE FORM

Transcription:

INTERNATIONAL JOURNAL OF PHARMACEUTICAL, CHEMICAL AND BIOLOGICAL SCIENCES Available online at www.ijpcbs.com Research Article DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF BENFOTIAMINE IN BULK AND DOSAGE FORM B. Pavan Adithya * and M. Vijayalakshmi 1Department of Pharmaceutical Analysis & Quality Assurance, Bapatla College of Pharmacy, Bapatla, Andhra Pradesh, India. ABSTRACT A new simple, precise, sensitive and validated RP-HPLC method was developed for the estimation of Benfotiamine in bulk and pharmaceutical dosage form. The chromatographic conditions used for the separation was Phenomenex Luna C18 (4.6x250mm,5μ) and mobile phase comprised of acetonitrile : methanol : water: 0.1% OPA (40:20:35:5 v/v). The flow rate was 1.0 ml/min with detection at 249 nm. The retention time was found to be 3.84 min. The linearity was found to be in the range of 5-35 µg/ml for benfotiamine with correlation coefficient of 0.9999. The proposed method is accurate with 99.278% - 100.791 % recovery and precise (%RSD of repeatability, intra-day and inter-day variations were 0.53, 0.45-0.67, 0.58-0.79).The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.1448 and 0.4388 µg/ml respectively. The method was successfully applied to pharmaceutical formulation because no chromatographic interferences from tablet excipients were found. Key words: Benfotiamine, RP-HPLC, Validation,Acetonitrile, Methanol.. INTRODUCTION Benfotiamine (S-benzoylthiamine O- monophosphate) is a synthetic S-acyl derivative of thiamine (vitamin B1) belonging to the family of compounds known as allithiamines. It is a lipid-soluble form of the Vitamin B-1 (1).. It may ease pain from neuropathy, retinopathy,nephropathy. By blocking AGEs (advanced glycation end products), it prevent some complications due to diabetes, such as blood vessel damage and atherosclerosis (2). Fig. 1: Structure of benfotiamine 354

Literature survey reveals that few HPLC (4,5) methods have been reported for the estimation of benfotiamine individually and combination with other drugs. Till now, there is no simple RP-Hplc method has been reported using simple solvents. The main objective of the present study is to develop simple, sensitive, accurate and precise RP- HPLC method for estimation of benfotiamine in bulk and tablet dosage forms. The validation has been carried out as per ICH guidelines. MATERIALS & METHODS Apparatus The chromatography was performed on a Waters HPLC instrument equipped with UV detector and Peak LC 7000 software, Phenomenex Luna C18 (4.6 x 250 mm, 5 μ particle size) was used as stationary phase. Shimadzu Ax200 analytical balance and Sonicator Pci Ultrasonic 3.5L100H were used in the study. Reagents and materials The reference sample of benfotiamine was supplied by Gulf exports, Mumbai. The formulation was procured from the local market. HPLC grade methanol, acetonitrile, OPA were purchased from Merck specialities private ltd, Mumbai. Selection of mobile phase Based on sample solubility, stability and suitability various mobile phase compositions were tried to get a good resolution and sharp peaks. The standard solution was run in different mobile phases. From the various mobile phases, acetonitrile: methanol : water : 0.1% OPA [40 :20: 35: 5 % v/v] was chosen with detection wavelength 249 nm, since it gave sharp peak with good symmetry within limits. Chromatographic conditions The optimized parameters which were used as a final method for the estimation of benfotiamine represented in the Table 1. Preparation of standard stock solution An accurately weighed quantity of benfotiamine (5 mg) was transferred to a 50 ml volumetric flask, dissolved and diluted to the mark with mobile phase to obtain standard stock solution of 100μg/ml. Preparation of calibration curve Aliquots of 0.5, 1, 1.5, 2, 2.5, 3, 3.5ml standard stock solution (100 μg/ml) was transferred to 10 ml of volumetric flasks and made up to the mark with mobile phase to get concentration of 5,10,15,20,25,30,35µg/ml. An aliquot (20 µl) of each solution was injected under the operating chromatographic conditions and responses were recorded. Calibration curve was constructed by plotting the peak areas versus the concentration and the regression equation was calculated. The standard solution was prepared by transferring 1.5 ml of 100µg/ml to the 10 ml of volumetric flask and made up to the mark with mobile phase to get 15µg/ml. Sample preparation Tablet powder equivalent to 15mg of benfotiamine is weighed and transferred to 100ml standard flask. Small amount of mobile phase is added to dissolve and then the volume is made up to the mark. Then it is filtered with 0.45 micron filter and sonicated. From this stock solution 1ml is transferred to the 10 ml volumetric flask and volume is made up to mark to prepare 15μg/ml concentration. Prepared sample solution was analysed. (Table 7) Method validation The optimized Chromatographic method was completely validated according to the procedures described in ICH guidelines Q2 (R1) for the validation of analytical methods (ICH, 2005) (5). System suitability test 20 µl of the standard solution was injected under optimized chromatographic conditions to evaluate the suitability of system. The values of system suitability parameters were shown in Table 2. Specificity Specificity of the HPLC method was demonstrated by the separation of the analytes from other potential components such as impurities, degradants or 355

excipients. A volume of 20µl of working placebo sample solution was injected and the chromatogram was recorded. No peaks were found at retention time of 3.84 min. Hence, the proposed method was specific for benfotiamine. Linearity The linearity of calibration curve in pure solution, over the concentration range of 5-35 µg/ml through proposed HPLC method. The data was represented in Table 3. Precision The precision of the method was determined by repeatability and intermediate precision (intra-day and interday). Repeatability The repeatability of the proposed method was ascertained by injecting six replicates of fixed concentration within the Beer s range and finding out the peak area by the proposed method. From this peak area %RSD was calculated. (Table 4) Intra-day precision Intra day precision was determined by injecting three different concentrations (90 %, 100% and 110%) for three times in the same day. Peak area was measured and %RSD was calculated. (Table 4) Inter-day precision Inter-day precision was determined by injecting three different concentrations (90 %, 100% and 110%) for three days in a week. Peak area was measured and %RSD was calculated. (Table 4) Accuracy For the accuracy of proposed method, recovery studies were performed by standard addition method at three different levels (50%, 100% and 150% of final concentration).a known amount of standard pure drug was added to preanalyzed tablet powder and the sample was then analyzed by proposed method. Results of recovery studies were found to be satisfactory and reported in Table 5. Robustness The robustness of the HPLC method was evaluated by analyzing the system suitability parameters after varying the ph of the mobile phase (± 0.2), organic solvent content (± 5%),wave length(±5nm) None of these alterations caused a significant change in peak area RSD, tailing factor and theoretical plates. Although the changes in the retention time were significant, yet quantitation was possible. The results were represented in Table 6. Limit of detection and Limit of quantification Limit of detection (LOD) and Limit of Quantification (LOQ) were determined by using the formula based on the standard deviation of the response and the slope.lod and LOQ were calculated by using equations, LOD=3.3 x /s and LOQ=10 x /s, where = standard deviation, S= slope of the calibration curve.(table 4) Results and discussions To develop simple and economical RP-HPLC method, several mobile phase compositions were tried. A satisfactory separation and good peak symmetry was obtained with Phenomenex Luna C18 (4.6 x 250 mm, 5μ) column and mobile phase comprising of acetonitrile : methanol : water : 0.1% OPA (40:20:35:5 v/v) at a flow rate of 1.0 ml/min to get better reproducibility and repeatability. Quantification was achieved with UV detection at 249 nm based on peak area. The retention time was found to be 3.84 min. The optimised method was validated as per ICH guidelines. The system suitability parameters observed by using this optimised conditions were reported in Table2. A linearity range of 5-35 g/ml with correlation coefficient 0.9999 was established. The result of recovery study by standard addition method ranging from 99.278 % to 100.791 % suggested the good accuracy. The precision of the proposed method was carried in terms of the repeatability, inter-day and intra-day time periods. The low % RSD values of repeatability (0.53%), inter-day (0.58% - 0.79% ) and intra-day (0.45 % 0.67 % ) variations reveal that the proposed method is precise. The LOD, LOQ values were found 356

to be 0.1448µg/ml and 0.4388µg/ml respectively. The absence of interference peak, indicates that method can be used for routine analysis of benfotiamine in pharmaceutical dosage form. CONCLUSION A specific, precise, accurate, rapid and reliable RP-HPLC method has been developed and validated. It has short runtime 10 min and retention time 3.84 allows analysis of large number of samples in a short period of time. In this method, there was no interference from tablet excipients. So this RP-HPLC method can be used in the quality control department. Table 1: Optimised chromatographic conditions Mobile phase Acetonitrile: methanol: water : 0.1% OPA[40 :20: 35: 5 % v/v] Stationary phase Phenomenex Luna C18 (4.6 x 250 mm,5 μ particle size) Wavelength 249nm Run time 10 min ph of the mobile phase 4.6 Flow rate 1 ml/min Injection volume 20 μl Temperature Ambient Mode of operation Isocratic elution Table 2: System Suitability Test Parameters System suitability parameters Results Retention time 3.84 Area 178135.1 Theoretical plate number 30976 Tailing factor 1.92 Table 3: Linearity data for benfotiamine Concentration (µg/ml) Peak area 5 55915.8 10 118024.5 15 178292.4 20 242973.3 25 307853.6 30 368942.2 35 434392.6 Table 4: Validation parameters of the proposed method Parameter Results Linearity (µg/ml) 5-35 Slope(b) 12620.19 Intercept(a) -8633.22 Correlation co efficient (r) 0.9999 Regression equation(y=mx+c) Y=12620.19x-8633.22 Precision Repeatability(%RSD, n=6) 0.53 Intraday precision(%rsd n=6) 0.45-0.67 Interday precision(%rsd,n=6) 0.58-0.79 % Recovery 99.278 100.791 Robustness Robustted LOD(µg/ml) 0.1448 LOQ(µg/ml) 0.4388 357

Drug name Benfotiamine Table 5: Recovery data Levels Amount Amount recovered added( g/ml) ( g/ml) %Recovery 50 % 7.5 7.485 99.8 Mean 100% 15 14.891 99.278 %Recovery 150% 22.5 22.677 100.79 99.956 SD 0.7685 Table 6: Results for robustness test of Benfotiamine Parameters Changes % Recovery Organic phase variation 60% 99.6 55% 99.1 ph of the Mobile phase variation 4.8 98.3 4.4 98.9 Wavelength variation 244 98.2 254 98.4 Table 7: Analysis of formulation Brand Name Drug Amount labelled (mg) Amount found (mg) %recovery %RSD Benforce Benfotiamine 150 149.97 99.97 0.47 Fig. 2: Benfotiamine API peak 358

Fig. 3: Benfotiamine formulation peak Peak area 500000 450000 400000 350000 300000 250000 200000 150000 100000 50000 0 Calibration curve of Benfotiamine y = 12620x - 8633. R² = 0.999 0 10 20 30 40 Concentration mcg/ml Fig. 4: Calibration curve of benfotiamine 359

REFERENCES 1. www.en.wikipedia.org/wiki/benfoti amine. 2. www.ehow.com/about_5645670_us es-benfotiamine. 3. Vinodhini C, Kalidoss SA and Srinivasan M. Development of high performance liquid chromatographic method for the estimation of Benfotiamine in tablets, Indian drugs. 2007;44(4). 4. Poongothai S, Ilavarasan R, arrunakarancmk. Simultaneous and accurate determination of vitamins B 1,B 6,B 12 and Alpha-lipoic acid in multivitamin capsule by Reverse- Phase High performance liquid chromatographic method, International journal of pharmacy and pharmaceutical sciences. 2010;2(4):133-139. 5. ICH, Q2 (R1) Validation of Analytical Procedures: text and methodology; 2005. 360