Study on the Selection of Representative Pulse Wave

Similar documents
Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

Spurious systolic hypertension 143

An Application of Data Leakage Prevention System based on Biometrics Signals Recognition Technology

Development of Tunnel Electrical Resistivity Prospecting System and its Applicaton

Pulse Reading Mobile Application: Dr. Chi

Project 4.2.1: Heart Rate

OEM MAXNIBP Frequently Asked Questions

Detection of Heart Diseases by Mathematical Artificial Intelligence Algorithm Using Phonocardiogram Signals

Estimation of Sympathetic and Parasympathetic Level during Orthostatic Stress using Artificial Neural Networks

Party Secretaries in Chinese Higher Education Institutions, Who Are They?

MICROGRAVITY EFFECTS ON HUMAN PHYSIOLOGY: CIRCULATORY SYSTEM

Young-Min Kim. Bachelor in Pharmacology, Seoul National University, South Korea, February 1993

A Study among Chinese Tourists in their 20s and 30s for Determining their Choice of Medical Tourism Destinations

Current Renal Replacement Therapy in Korea - Insan Memorial Dialysis Registry, ESRD Registry Committee, Korean Society of Nephrology*

A practical and novel standard addition strategy to screen. pharmacodynamic components in traditional Chinese medicine using

Reducing Motion Artifact in Wearable Bio- Sensors Using MEMS Accelerometers for Active Noise Cancellation

Evaluation copy. Analyzing the Heart with EKG. Computer

Feature Vector Selection for Automatic Classification of ECG Arrhythmias

The Big Data mining to improve medical diagnostics quality

Signal Extraction Technology

Dept. of Physical Education

DEPARTMENT OF OCCUPATIONAL THERAPY TEL: EXT CHAIRPERSON: Kuo, Li-Chieh BRIEF INTRODUCTION

The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals

Thought on the Construction of Differentiated Performance Management System for University Teacher

INVESTIGATING HEART RATE AND BLOOD PRESSURE

LabVIEW and Web-Server based Human Body Monitoring System

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

Reavis High School Anatomy and Physiology Curriculum Snapshot

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

Insook Yang, Fellow, KWDI Soyeon Lee, Fellow, KWDI

University of Michigan Dearborn Graduate Psychology Assessment Program

FACULTY OF ALLIED HEALTH SCIENCES

Advanced MRI methods in diagnostics of spinal cord pathology

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

Biomedical engineering

Analysis of Regression Based on Sampling Weights in Complex Sample Survey: Data from the Korea Youth Risk Behavior Web- Based Survey

Heartbeat Monitoring Alert via SMS

INTERNATIONAL MASTER S PROGRAM IN DEPARTMENT OF JOURNALISM

THE GIANT HEART K-12 EDUCATOR S GUIDE

An ECG Monitoring and Alarming System Based On Android Smart Phone

HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise

3rd International Conference on Science and Social Research (ICSSR 2014)

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

2. Professor, Department of Risk Management and Insurance, National Chengchi. University, Taipei, Taiwan, R.O.C ;

Human-like Arm Motion Generation for Humanoid Robots Using Motion Capture Database

Have you ever missed a call while moving? : The Optimal Vibration Frequency for Perception in Mobile Environments

WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE

WARSAW SCHOOL OF ECONOMICS

BIPOLAR LIMB LEADS UNIPOLAR LIMB LEADS PRECORDIAL (UNIPOLAR) LEADS VIEW OF EACH LEAD INDICATIVE ECG CHANGES

The role, responsibilities and status of the clinical medical physicist in AFOMP

Human ECG Laboratory Experiment By

Analysis of Influence Factors on Scientific and Technological SMEs Financing Based on DEMATEL

Gender Equality Project. Background to the Athena SWAN Charter

Computational Modeling and Simulation for Learning an Automation Concept in Programming Course

Sample Size and Power in Clinical Trials

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

An evaluation of a tailored intervention on village doctors use of electronic health records

Screening for Critical Congenital Heart Disease in the Apparently Healthy Newborn

Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection Swarup Sarkar 1, Akash Kumar Bhoi 2, Gyanesh Savita 3 1,2,3

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

An approach of detecting structure emergence of regional complex network of entrepreneurs: simulation experiment of college student start-ups

Heart Rate Detection from Ballistocardiogram

International Health Program in National Yang-Ming University

DRIVER ATTRIBUTES AND REAR-END CRASH INVOLVEMENT PROPENSITY

Remote Patient Monitoring- An Implementation in ICU Ward

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.


HTEC 91. Topic for Today: Atrial Rhythms. NSR with PAC. Nonconducted PAC. Nonconducted PAC. Premature Atrial Contractions (PACs)

1. Introduction. 1.1 Background and Motivation Academic motivations. A global topic in the context of Chinese education

Advanced Nursing Practice Development in Mainland China. Dr. Hu Yan School of Nursing, Fudan University

Development of XML-based Standardized Software Database Specifications and Operating Schema

huidige en toekomstige hemodynamische bewaking

Chun-mei Hu 1, Shu-jing Cui 1, Lei Wang 1

Chapter 2. Education and Human Resource Development for Science and Technology

The Analysis on Employability Gap of Students in China Vocational-Technical School and Its Causes

STATS8: Introduction to Biostatistics. Data Exploration. Babak Shahbaba Department of Statistics, UCI

Saving healthcare costs by implementing new genetic risk tests for early detection of cancer and prevention of cardiovascular diseases

Investigation of the Residual-charge Technique for Diagnosis of Water-tree Deteriorated Cross-linked Polyethylene Cable

Monitoring and Warning System for Information Technology (IT) Outsource Risk in Commercial Banks Based on Nested Theory of Excel Logical Function

Dong-Soo Lee, Ph.D M.B.A., Kyunghee University, Korea Major in Tourism Administration Graduate School of Business Administration

Characteristics of Binomial Distributions

Efficient Heart Rate Monitoring

A Load Balancing Algorithm based on the Variation Trend of Entropy in Homogeneous Cluster

A STUDY OF THE EFFECTS OF ELECTRONIC TEXTBOOK-AIDED REMEDIAL TEACHING ON STUDENTS LEARNING OUTCOMES AT THE OPTICS UNIT

Journal of Chemical and Pharmaceutical Research, 2014, 6(3): Research Article. Analysis of results of CET 4 & CET 6 Based on AHP

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

The Data Analysis of Primary and Secondary School Teachers Educational Technology Training Result in Baotou City of Inner Mongolia Autonomous Region

Perioperative Cardiac Evaluation

SU Qiang Professor

The study on the Human Resource Management of the Logistics Enterprises Based On the Competency Model

MATHEMATICAL LOGIC FOR COMPUTER SCIENCE

A NUMERICAL ANALYSIS BASED SUBSTITUTE METHOD FOR SHAKING TABLE TEST IN CONSIDERING OF THE SOIL-STRUCTURE INTERACTION

CHARACTERIZING OF INFRASTRUCTURE BY KNOWLEDGE OF MOBILE HYBRID SYSTEM

A Fuzzy System Approach of Feed Rate Determination for CNC Milling

Establishing the Uniqueness of the Human Voice for Security Applications

Electric Power Engineering Education in Korea: Status Report

On government performance management development. strategies based on E-government

Traffic Safety Facts Research Note

Transcription:

28. Vol.29. No.5. 14-11 The Journal of Korean Oriental Medicine Original Article Study on the Selection of Representative Pulse Wave Jong-Yeol Kim 1, Sang-Hoon Shin 2 1 Korea Institute of Oriental Medicine, 2 Dept. of Oriental Biomedical Engineering, Sangji University Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point( ) with 142 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave. Key Words : representative pulse wave, shape accordance, floating-sinking ratio, pulse height, pulse time Introduction Pulse diagnosis, which uses the senses of the doctor s finger in order to observe the pulsation, therefore examining the condition of the patient s inner organs and meridian pathways, is an important method of assessment in Oriental medicine. With the Pulse Diagnosis Apparatus, the pulse diagnosis have made a great progress in providing a objective definition of the characteristics of the pulses, which had been characterized in terms of natural phenomenon or poetic expressions. Furthermore, there are several attempts to standardize the doctors subjective diagnosis with the Pulse Diagnosis Simulator 1). Researches on the objectification of pulse diagnosis can be broadly divided into 4 parts; pulse formation mechanism, objective description of the pulse waves, objective measurement and examination of the pulse waves, and objective analysis of pulse waves 2). Some research has made efforts to interpret the formation mechanism of the pulse waves by analyzing the hemodynamic analysis of the cardiovascular system 3) and also by analyzing the motion of radial artery in an anatomical point of view 4). Some research has discussed an objective standard for pulses 5), and classified the 28 traditional pulses systematically 6). To objectify the description of pulse, several studies have been made on the measurement parameters except blood pressure, such as the palpation sound of the artery 7) and the hemodynamic parameters by the supersonic waves 8). Some studies have focused on the automation of pulse recognition and assess- Received:26 September 28 Revised:1 November 28 Accepted:11 November 28 Correspondence to:jong-yeol Kim 461-24, Korea Institute of Oriental Medicine, Jeonmin-dong, Yuseong-gu, Daejeon, 35-811, KOREA Tel:+82-42-868-9489, E-mail:ssmed@kiom.re.kr 14

Study on the Selection of Representative Pulse Wave (95) ment with computer 9). To develop a pulse diagnosis apparatus combinable to the traditional pulse diagnosis principles, measurement signals that have a significant meaning to oriental medicine theories are required. The representative pulse wave, selected among several pulse wave signals, is a essential element in determining the pulses status (floating pulse or sinking pulse) and figure. This research critically analyzed the problems of the existing method used to select representative pulse waves, and then suggested a new method by considering the physiological characteristics of the artery. 1. Research subjects. Materials and Methods Pulse waves were acquired from 142 apparently healthy people who visited the Medical Center in order to take a medical check up. Excluding 427 data with errors, this research used data of 993 subjects. Table 1 shows the reason of excluding. The following table is the gender and age distribution of the subjects. 2. Selection of representative pulse wave To distinguish the method of pulse diagnosis, the following terms were used. Hemodynamic pulse wave is the blood pressure wave of the artery excluding the palpating pressure. On the other hand, hemodynamic pulse wave with the palpating pressure are called the pulse wave. 1) measurement of pulse wave Pulse wave signals were measured at the Guan point( ) with the Pulse Diagnosis Apparatus (3-D Mac, Daeyo Medi, Korea). When the sensor approximately positioned near the subject s Guan point, the 3-D Mac compared signals from the 5 sensors and automatically located the center measuring sensor on the Guan point. The 3-D Mac adjusted the pressure Table 1. reason number of data missing Guan( 關部 ) data 48 missing constitution data 5 missing data file 2 missing excel file 34 measurement error 19 pulse shape detection error 84 T1 detection error 19 total 427 Table 2. male female Total Age (years) 1-19 2-29 3-39 4-49 5-59 6-69 7- Total N 7 2 19 166 185 56 14 557 % 1.3 3.6 19.6 29.8 33.2 1.1 2.5 N 2 28 84 166 19 28 19 436 %.5 6.4 19.3 38.1 25. 6.4 4.4 N 9 48 193 332 294 84 33 993 %.9 4.8 19.4 33.4 29.6 8.5 3.3 15

(96) The Journal of Korean Oriental Medicine 28;29(5) 1 Low Pressure High Pressure 5 1 15 2 25 Step1 Step2 Step3 Step4 Step5 Blood Pressure [mmhg] T1 H1 2 A 3 Time [sec.] Fig. 1. Fig. 2. range into 5 stages, and pressed the measuring point with constant pressure for 5 seconds, according to each stage. Fig.1 shows the measured pulse wave signals. 2) The characteristics of the pulse wave signals. Fig.2 shows the typical pulse wave signal. We could observe three peaks from a pulse wave. The first peak is caused by the contraction of the heart, the superposition of the reflected wave effect the shape of the second and the third peak. The first peak is a critical index of the contraction features of the heart. In this study, H1 represents the pressure of the first peak and T1 represents the time of the first peak. A represents the area of the pulse wave. Physically, A means the energy of the pulse wave. 3) The conventional method of selecting representative pulse waves. The conventional method selects the representative pulse wave with the basis of H1. Among the representative pulse waves of each steps, the pulse wave with the highest H1 is selected as the representative pulse wave for 5 steps. Fig.3(a) shows the representative pulse waves for each step of the measured signals in Fig.1, and Fig.3(b) is the representative pulse wave of all steps. 3. Problems of the conventional method. By analyzing the representative pulse waves that were acquired by the conventional selection method, the following problems were found. 1) The decrease of pulse wave area (A) was not reflected. 2 2 Fig. 3. 16

Study on the Selection of Representative Pulse Wave (97) 2 Fig. 4. There were cases in which even if the H1 was the highest, the A was not the maximum. In Fig.4, the 5th step becomes the representative pulse wave with the highest H1 standard. However, the A of 5th step is smaller than that of 4th step. The Physical meaning of the A is the energy of pulse wave, it must be carefully considered. 2) The shape of the left and right representative pulse waves was not in accordance. Fig.5 shows the left and right pulse wave of an identical subject. Both the 3rd stage of each hand was selected as the representative pulse wave. However, the shape of each wave did not match. To determine the shape accordance of the two pulse shapes, the shapes of three pulse peak was used. Although the pulse wave is a hemodynamic pulse wave with the palpating pressure, the main factor for the shape of wave is the physiological characteristics of the artery. Symmetry is the basic rule of the human body, the left and right representative pulse wave should not be in severe discordance. With the H1 based selecting method, the shape accordance ratio of the representative pulse waves for both hands was 62%. 3) The ratio of the sinking-pulse was too high In this study, the floating pulse is defined as the pulse which has the representative pulse in the 1st or 2nd step. The middle pulse has the representative pulse in the 3rd step. The sinking pulse has the representative pulse in the 4th or 5th step. The ratio Fig. 5. 17

(98) The Journal of Korean Oriental Medicine 28;29(5) of floating/middle/sinking pulse with the H1 based method was, 19%/33%/48% in the left hand, 7% /2%/73% in the right hand. The deviations among the ratios were considerable, and especially the ratio of the sinking pulse was too high. Also the discordance of the left and right ratio of floating/middle/ sinking was serious. 4. Comparison of the selecting methods for the representative pulse wave The three methods for selecting the representative pulse wave were compared. With qualitative analysis of clinical data, T1, H1, A were selected as the evaluation parameter for selecting the representative pulse wave. The H1 based method, which is the conventional method, selects the waveform with the highest H1 as the representative pulse wave. The T1 based method selects the waveform with the longest T1 as the representative pulse wave. Similarly, A based method selects the waveform with the largest A as the representative pulse wave. Results and Discussion The three methods for the selecting representative pulse wave were compared with 993 subjects. 1. The shape accordance of the left and right representative pulse waves Table 3 shows the result of the shape accordance of the representative pulse wave with 993 subjects. T1 based method showed the maximum accordance. The A based method showed the minimum accordance. According to the cardiovascular physiology, the pressure wave is produced by the ejection of blood by left ventricle. The wave is transmitted to the upper limb and the lower limb along the artery. And the hemodynamical pulse wave is formed with the superposition of the reflected wave and the forwarding wave 1). Therefore the main factor for the shape of the pulse wave is the physical characteristics of the artery. Since the physical characteristics of the left and right arteries are generally identical, there should be little difference in the shape of the pulse waves measured at the radial artery of the Table 3. A T1 H1 accordance n 594 696 611 % 6 7 62 discordance n 399 297 382 % 4 3 38 total n 993 993 993 Table 4. A T1 H1 left right left right left right floating n 265 14 415 289 186 7 % 26.7 1.5 41.8 29.1 18.7 7. middle n 281 227 214 219 329 23 % 28.3 22.9 21.6 22.1 33.1 2.4 sinking n 447 662 364 485 478 72 % 45. 66.7 36.7 48.8 48.1 72.5 total n 993 993 993 993 993 993 18

Study on the Selection of Representative Pulse Wave (99) both wrist. Although the pulse wave is a hemodynamic pulse wave with the palpating pressure, the main factor for the shape of wave is the physiological characteristics of the artery. The characteristics of the skin of both hands don t differ significantly, the shape of the pulse waves at both hands should be identical. With qualitative analysis of clinical data, we found that T1 is closely related to the representative pulse wave. In other words, the shape of the pulse wave was changed after the maximum step of T1. T1 based method increased the shape accordance of pulse waves than the H1 based method. 2. The ratio of the floating pulse and the sinking pulse Table 4 shows the floating and sinking ratio of the three methods. The imbalance of the floating and sinking ratio of the right hand was more serious than that of the left hand. And the ratio of sinking pulse was high. H1 based method showed the worst case at the both hands. For example, in the H1 based method of the right hand, the floating pulse ratio was 7%, whereas that of the sinking pulse was 72.5%. The T1 based method showed a fairly reasonable proportion between the floating pulse and the sinking pulse. The floating-sinking status of the pulse is the pulse location where the most apparent pulse beat is measured. It can be said that the floating pulse is observed at the low pressure compared to the sinking pulse. Although the scientific mechanism of the floating-sinking pulse is still unknown, the excessive rate of sink pulse seems not natural. So we selected the method in the point of minimizing the imbalance. Shin 11) proposed a mathematical model considering the characteristics of the skin, and reported that the thickness of the skin increases the tendency of sinking pulse. Presuming that a person normally uses his/her right hand, the thickness of the right hand is larger than that of the left hand. So it is reasonable that the ratio of the sinking pulse of the right hand is larger than that of the left hand. According to Table 4, in all cases the ratio of the sinking pulse of the right hand is larger than that of the left hand. Nevertheless, the excessive imbalance of the sinking pulse is hard to see as a normal physiological characteristic. Till this point, there has been almost no researches regarding representative pulse waves. In western medicine the inner pressure of the blood vessels are emphasized, so there is no such concept like pulse diagnosis as in oriental medicine, which observes the pulse waves according to the added pressure on the skin. Even in Korea, researches on Pulse Diagnosis Apparatuses have been the majority, with no gold standard on how to select a representative pulse wave. I carefully assume that this research is the first to present a standard on representative pulse waves. By adopting the symmetry theory which is the most fundamental characteristic of the human body, this research selected the left and right accordance and the symmetry of the sinking/floating pulse ratio as the standard for representative pulse waves. Not having been able to supply a quantitative parameter for the comparison of the left/right pulse shapes is the limitation of this paper, but this remains as a matter to be presented through further investigation in the near future. Conclusion Pulse waves were acquired from 142 people who visited the Medical Center in order to take a medical check up. Pulse wave signals were measured at the Guan point( ) with the Pulse Diagnosis Apparatus (3-D Mac, Daeyo Medi, Korea). Excluding data with errors, the three methods for selecting the representative pulse waves were compared with the data of 993 subjects. The three methods for the selecting representative pulse wave were compared. With qualitative analysis of clinical data, T1, H1, A were selected as the evaluation parameter for selecting the representative 19

(91) The Journal of Korean Oriental Medicine 28;29(5) pulse wave. The H1 based method, which is the conventional method, selects the waveform with the highest H1 as the representative pulse wave. The T1 based method selects the waveform with the longest T1 as the representative pulse wave. Similarly, A based method selects the waveform with the largest A as the representative pulse wave. 1. The shape accordance of pulse waves at both hands was maximum in the T1 based method. The A based method showed the minimum accordance. 2. The imbalance of the floating and sinking ratio of the right hand was more serious than that of the left hand. The ratio of sinking pulse of the right hand was larger than that of the left hand. The T1 based method showed a fairly reasonable proportion between the floating pulse and the sinking pulse. T1 based method was more reasonable than conventional H1 based method in the point of the shape accordance of pulse waves at both hand and the balance of the floating and sinking ratio. Acknowledgement This research was supported by a grant from the Next Generation New Technology Development Program (28438) funded by the Ministry of Knowledge Economy of the Korean Government. Reference 1. Tang WC, Sun HJ, Xu JG, Li BF. A study of the traditional chinese pulse simulator system. China Journal of Basic Medicine in Traditional Chinese Medicine 2; 6(1): 62-65. 2. Shin SH, Park YB, Rhim HW, Kim KW. A study of the pulse diagnosis research trend in China. The Journal of the Korea Institute of Oriental Medical Diagnostics 24; 8(2): 45-56. 3. Shin SH, Rhim HW, Park YJ, Park YB. A Study of the cardiovascular aging effect on the pulse shape. The Journal of the Korea Institute of Oriental Medical Diagnostics 25; 9(1): 59-68. 4. Niu X, Yang XZ, Fu CY, Liu ZW, Liu WP. Three-dimensional motion of the radial artery and attributes of position, rhythm, shape and variance of pulse diagnosis. Chinese Journal of Integrated Traditional and Western Medicine 1994; 14(7): 435-437. 5. Fei ZF, Zhang ZF. Imagint and quantification of traditional pulse taking. Nature Magazine 1995; 17(5): 27-32. 6. Li JT. The objective detection and description of the types of pulse based on the chinese traditional medical science. Chinese Journal of Medical Instrumentation 21; 25(6): 318-323. 7. Wang BH, Yang YX. Experiment Design and Power spectral Characteristics of Pulse Signals. Chinese Journal of Physical Medicine and Retabulitation. 1998; 2(3): 158-161. 8. Xu F, Lu Y, Xiao HS. 4 Cases of Determination on Radial Artery Blood Flow of Wiry Pulse and Non-wiry Pulse by CVIQ. Liaoning Journal of Traditional Chinese Medicine 2; 27(4): 153-154. 9. Huh W, Han SC, Park YB. Feature Point Detection of Radial Pulse Wave. The Journal of the Korea Institute of Oriental Medical Diagnostics 2; 4(2): 66-7. 1. Nichols WW, O Rourke MF. McDonald s blood flow in arteries. 5th ed. London: Edward Arnold. 1998: 193-213. 11. Shin SH. A study of analytical model for the pulse formation mechanism. Ph.D. Thesis, Kyunghee University. 26: 49-6. 11