DIRECT PUSH DRILLING.



Similar documents
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

product manual H-4210A PORTABLE STATIC CONE PENETROMETER

KWANG SING ENGINEERING PTE LTD

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Step-by-step instructions:

Standard Test Procedures Manual

#62192 Moroso Degree Wheel with Intake Center Line Calculator Instructions:

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

Installation (Figure 1) (Figure 4) (Figure 5) (Figure 2) (Figure 3) (Figure 6)

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Geotechnical Investigation using Standard Penetration Test (SPT) in Rangamati, Bandarban and Khagrachari Towns

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

White Industries Rear Hub Instructions

SUPERCHIPPER CASTING MAINTENANCE

Service Manual Rol-Lift

2006 HEADSHOK Service Video #1

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Rebuild Instructions for and Transmission

Stainless Steel Single and Dual Circulation Kits

Geotechnical Investigation Test Report

Testing Procedures. Note: Please refer to Table 2 for a list of completed borings.

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

ASSEMBLY DIAGRAM AND ASSEMBLY REFERENCE ULTIMA OLD SCHOOL 2 EVO & TC BELT DRIVE UNITS

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Installation Instructions

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

Manual for the injector shaft cleaning kit Toyota

1.8 CRANKSHAFT OIL SEALS

INSTRUCTIONS: LocknCharge Laptop Carts

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

MGB Chrome Bumper Conversion

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.

Repairing the Seam of the WaterRower Tank

Standard Penetration Test Driller s / Operator s Guide DSO Earth Sciences and Research Laboratory

DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below)

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS

GTI VR6 Front Wheel Bearing DIY

[4] SA1.2 The student demonstrates an understanding of the processes of science by observing,

An introduction to Reverse Circulation drilling

COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA GEOTHERMAL FIELDS.

Installation Instructions S

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

NOTES on the CONE PENETROMETER TEST

Joplin Rebuild Instructions

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S.

OWNER S MANUAL Table Tennis Table Patent Pending

Industrial Strength Rocket Launcher

AM/FM ANTENNA RELOCATION KIT

DRILLING METHODS. The material below reviews the range of hole making and hole clearing approaches in common use in the drilling industry.

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Tri-Homo Style Operation and Maintenance Instructions

How To Design A Foundation

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

Parts#MB Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

FAG Hydraulic nuts. Technical Product Information

DANA 30 MANUAL HUB CONVERSION KIT

CIVL451. Soil Exploration and Characterization

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Standard Sleep Pod Side Entry Assembly Instructions

BUTE Department of Construction Management and Technology

Reasons for reissue are in Section 6, REVISION SUMMARY.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

SHOT BLAST CABINET MODEL NO: CSB20B

Go-kart for little race-drivers

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

Cylinder head, removing and replacing

Double Glider Assembly Instructions.

Chittagong Hill Tract Development Facilities (CHTDF) United Nations Development Programme

Front axle components, overview

2005 MINI Cooper MANUAL TRANSMISSIONS On-Vehicle Servicing. Cooper S Getrag 285

System. Stability. Security. Integrity. 150 Helical Anchor

APPENDIX A PRESSUREMETER TEST INTERPRETATION

TopSky DLG Installation Manual

1000-LB. TRAILER JACK OWNER S MANUAL

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Figure Place selector lever on SAFE. If rifle is not cocked, selector lever cannot be pointed toward safe.

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

The "DAVID" Steam Engine By Alan Marconett Hobbit Engineering

Pepper Mill Instructions by Fred Kachelhofer

MP-4V Heavy Duty Riveter / 39048

valid as of 1 April 2014 Intec injection hose system

Wiper Motor Marinco 2.5. Installation Instructions

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Clif Mock. True-Cut C21/C22 Isokinetic Sampler. User Manual. Manual No , Rev. B

QUESTION TO AUDIENCE

Things you need to assemble the tube actuator. Left to right. are small piece of masking tape, super glue,pen knife and small

Foam Wiping Technology

Eric Six Heath Consultants Incorporated

Transcription:

DIRECT PUSH DRILLING. CONCEPT. Direct Push Drilling is a method of drilling and sampling where the tools are pushed or driven into the ground. No rotation is involved so all the samples are uncontaminated and there is no drilling debris on the surface. The main application for this method is for drilling various soils, clays and sands both consolidated and unconsolidated. It allows the driller to take a core sample sealed inside a plastic tube so that no handling of the sample takes place. Make up of Equipment. The equipment consists of an outer rod called an Outer Extension measuring 4' x 2 1 / 8 " to this a cutting shoe called an External Drive Tip is fitted. For sampling a plastic tube the same length as the outer extension and having an I.D. of 1½" is inserted into the extension, this fits into the back of the drive tip fitting snugly into special recesses cut into it. These recesses are cut according to the kind of sample that will be taken. Each drive tip is manufactured for different formations and uses. On the back of the Plastic Sample Tube a Plastic Grabber is fitted to hold the sample tube and to allow for smaller internal rods, Internal Extensions, to be added. Before driving the extensions into the ground a Thread Protector is screwed onto the Plastic Grabber or Inner Extension rod and a Drive Head Adaptor is then screwed onto the Outer Extension. This assembly is then placed under a hammer fitted onto the mast of the drill, pressure is then applied to the assembly pushing it into the ground assisted by the hammer which helps drive it into the ground. When the required depth is reached the Drive Head Adaptor and Thread Protector are removed and the Inner Extensions and Plastic Sample Tube are removed. Another tube is then inserted and an Outer Extension with Inner Extension is then added and the process is repeated until the required depth or refusal is reached.

Discrete Soil Sampling. This is a process of probing to a specified depth and retrieving a sample. This is achieved by choosing the correct External Drive Tip and corresponding Internal Drive Tip for the prevailing soil conditions. There are five choices for discrete sampling. See Figure 1 below. Standard External Drive Tip - Used in soils that have good cohesive properties and will maintain a fixed shape.

Oversized External Drive Tip - The Oversized Drive Tip provides a greater displacement of the surrounding soil therefore reducing sidewall friction between the outer Extensions and the soil. In some soil conditions this may allow you to probe to deeper depths. Core Catcher External Drive Tip - Used in soil conditions that do not have good cohesive properties and have a tendency to flow. The core catcher, used on the end of the liner allows soil to travel up in the liner but does not allow soil to escape as the liner is being retrieved. This tip is basically a Standard External Drive Tip that has been modified to accept a core catcher. Clay External Drive tip - Used for heavy and expanding clay soils. The clay tip has a slightly smaller inner diameter. This smaller diameter enables the sample to carry up into the liner more effectively in expanding clay soils. The liner fits over the top of the Drive Tip rather than into the Drive tip. This prevents soil from entering the area between the Liner and the Outer Extension. Oversized Clay External Drive tip - The Oversized Clay Drive Tip has an outsize diameter that is larger than the Standard Clay Tip, but the inside diameter is the same. The Oversized Clay Tip helps to reduce sidewall friction between the outer Extensions and the surrounding soil. In some conditions this may allow you to probe deeper. Once you have made the choice of External Drive Tip and Internal drive tip, you then assemble the equipment first fitting a plastic liner to the External Drive tip and screwing it onto the Outer Extension, the Internal drive tip is then screwed onto the end of of an Inner Extension. The thread protector and Drive Head Adaptor are fitted and the equipment put into place under the hammer. This is then driven into the ground to it s full length and another Outer and Inner Extension are fitted, driven into the ground and repeated until you reach the desired depth. The thread protector and Drive Head Adaptor are removed and the Inner Extensions removed. The drive Head Adaptor is refitted and the

equipment driven into the ground. The equipment is then removed from the hole and the plastic sample liner removed and capped. See Figure 2.

Continuous Soil Coring. Continuous soil coring is the process of taking a continuous soil sample from ground level to a defined depth. Continuous soil coring is accomplished most effectively by the use of the Dual Tube System. This system leaves the outer extension in place, providing a cased hole through which to sample. This permits sampling in collapsing holes or through perched ground water and also prevents downward cross contamination while sampling is taking place. The External Drive Tips are the same as for discrete sampling. See figure 1. The operation is carried out as follows: 1. Thread the Plastic Line Grabber onto the Plastic sample liner. (If using a Core Catcher Drive tip, place the core catcher on the other end of the liner). 2. Thread the External Drive Tip of your choice into the first Outer Extension. 3. Insert the liner into the first extension and rotate it as you push down making certain the liner seats in the drive tip. See figure 3.

4. Thread the thread protector onto the line grabber and thread the drive head adaptor onto the outer extension. 5. Position the equipment beneath the hammer on the mast then drive the length of the liner. 6. Remove the drive head adaptor and place a spanner on the thread protector cap and rotate clockwise for ½ a turn before retrieving the liner. This shears the soil at the tip enabling you to retieve the sample without it falling back out of the liner. 7. Remove the line grabber and cap the liner after marking the depths on it 8. Replace the liner and add another outer extension and inner extension, replace the thread protector and drive head adaptor then repeat the process untill you are at the required depth or at refusal. See figure 4&5.

Using Direct Push in Conjunction with Hollow Stem Augers. There will be occasions when for one reason or another i.e. too much sidewall friction, when you cannot drive the direct push tools any further. In this event hollow stem augers can be used to drill down to the last depth reached and the direct push tools lowered through the centre of the augers and the sampling continued.

DIRECT PUSH DRILLING FOR SWIRLING SANDS A new style piston sampler has been developed to allow us to be able to core swirling sands. This has been successfully used at R.B.M. in Richards Bay and sand quarries at Pienaarspoort near Pretoria. I both cases there was a lot of water present just under the surface. We were able to continuously core the sand through the water until, in both cases, we hit ferrocrete. The piston sampler is pushed down, as for the dual tube sampling system, to the desired depth where sampling is to begin. Once at the sampling depth the inner rod attached to the inner drive tip is removed and an additional 4 ft (1.22m) outer rod extension is added. At this point the rod is pushed and the sample is retrieved. Additional sampling intervals at greater depths can be retrieved using the same drilling method. There is no chance of losing the centre rod and any caving/slumping that has occurred will not fill the piston sampler s liner. Any premature material that enters the sampler and liner is pushed out of and above the liner when the liner is filled from the desired sample interval. The piston sampler is designed to collect discrete (interval specific) samples in difficult sampling conditions, such as flowing/heaving sands and swelling clays. The system also works well in soils below groundwater. Also the piston sampler is designed minimize or prevent liner failure during sample collection. Two O rings can be used on the bottom tip thus minimizing the chance of cross contamination from material entering the sampler prior to the desired sampling depth. The use of, either or both of, two core catcher options can minimize or eliminate the chance of loss of the core sample.