Mercury Vapor Emission from Broken Compact Fluorescent Lamps and Cleanup procedures

Similar documents
How to Clean Up Spilled Mercury (for Homes)

Energy efficient lighting for your home find out more.

NOTES: NEVER use an ordinary vacuum or shop vacuum to clean up mercury

Cleaning up spilled mercury in the home

MERCURY. It also has been used in hospital and dental environments and may be found in sink traps and collection basins.

INSTRUCTIONS FOR CLEANING UP SMALL LIQUID MERCURY SPILLS IN HOUSEHOLDS. Northeast Waste Management Officials Association April 2003

The Lamp Recycling Outreach Project

Frequently Asked Questions about Hazardous Waste Lamps (e.g., fluorescent or other lights containing mercury)

This article reviews what to do in the event of a household mercury spill.

Dentistry and the Environment

Health Consultation. Chemically Contaminated South Minneapolis Residence. City of Minneapolis, Hennepin County, Minnesota. March 2002.

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

SPILLS & SPILL KITS. Spills -General Guidelines:

MOLD REMEDIATION KEY STEPS

Policies. Prep Room Policies

Indoor Air Mercury May 2003

Asbestos in your home

Research Project Summary. Release of Mercury From Broken Fluorescent Bulbs

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

UV100A Ultraviolet Air Treatment System

Mold Response and Remediation Plan

MOLD RESPONSE AND REMEDIATION PLAN

Asbestos Removal Procedures for Homeowners

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION

7. Chemical Waste Disposal Procedures

How to Properly Remove Cement Asbestos Board Siding

Where is it found? Elemental form: in barometers, blood pressure instruments, thermometers, and other pressuresensing

Glass & Hard Plastic Control

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

Protection Against Hantavirus. How to safely clean-up rodent droppings, dead rodents, and nests

A SADC Residential Compact Fluorescent Lamps Rollout Program by Southern African Power Pool (SAPP)

Guidelines for Cleaning Staff on Managing Mould Growth in State Buildings

Chemotherapy Spill Response:

Standard Operating Procedure for Blood Borne Infectious Disease Control Measures at Calvin College

Best Management Practices for Mercury Waste Management in Dental Offices

Contents list for: MERC-KIT Mercury Spill Kit:

Thermostats A temperature control device that contains metallic mercury in an ampule.

SANITATION AND PEST CONTROL INSPECTION REPORT INSPECTOR: BUSINESS NAME:

Reuse The Recycling Zone offers usable household chemicals and paint free for the taking. The Reuse area is open during normal business hours.

Excerpts from EPA s Mold Remediation in Schools and Commercial Buildings

Paper Chromatography: Separation and Identification of Five Metal Cations

UNIVERSAL WASTE MANAGEMENT TRAINING

Asbestos frequently asked questions

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Storage and treatment of fluorescent lamps

Health Consultation. Mercury Exposure Incident FAIRHAVEN HIGH SCHOOL FAIRHAVEN, MASSACHUSETTS JULY 8, 2008

RESIDENTIAL SERVICES. compost recycle landfill

Presentation Outline

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

Technical Information Paper No

Mold Management Plan Operations & Maintenance

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

A guide to understanding and maintaining your home s electrical system. A publication presented by the Electrical Safety Foundation International

ST. CLOUD TECHNICAL AND COMMUNITY COLLEGE HAZARDOUS WASTE PROCEDURE

File: Spill Response Plan for Hazard Chemicals and Mercury Spills. Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010

This Little Light of Mine: Understanding Light Bulbs By Tracy Empson

Bird and bat droppings

Guidelines for Mold Remediation (Removal)

Description Purpose Health Education. Health Assessment. Outcomes of the program Partners Contact Information

CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

USEPA Risk-Based Standards for Controlling Contaminated Sites Soil Screening Levels (SSLs) April 2, 2007 Aaron Yeow, USEPA

Biological Safety Program

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Revision 5. Calvin College Medical Waste Management Plan. Date: Health and Safety

Brock University Facilities Management Operating Procedures

Policies and Procedures Manual Waste Management Plan Policy No. 06:04:00 Page 1 of 12

NORMI Professional Guidance for DIY Projects

MATERIAL SAFETY DATA SHEET Utrecht Gesso Painting Grounds. Section 2 Hazard Identification (composition / information on ingredients)

BODILY FLUID CLEAN UP PROCEDURES

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

Turn off the tap while you brush your teeth You ll conserve up to 5 gallons of water per day.

1. The Determination of Boiling Point

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

Housekeeping Standards general store areas.

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

Addendum 1 Clarifications

ASTCCR2 - SQA Unit Code H Carry out and complete clean-room cleaning operations

Waste Management Program

Shielding Ourselves from Ultraviolet Light

Low / High Bay Datasheet

State of Illinois Illinois Department of Public Health OUT. Homeowner s Lead-based Paint Abatement Guide

Best Management Practices

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Asbestos in Your Home

Universal Waste Management

GUIDELINES FOR THE CLEANING UP OF BODILY FLUIDS

The purpose of this document is to provide guidance on the safe removal and disposal of asbestos and asbestos-containing materials.

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

UBC Plant Operations Asbestos Work Procedures April 2004

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS)

Lighting Retrofit Incentive Application for Business Customers

About Pure Earth and the Toxic Site Identification Program

WATER DAMAGE FOLLOW-UP INVESTIGATION. Massachusetts Department of Children and Families 33 East Merrimack Street Lowell, Massachusetts

Energy-efficient lighting

Clean Water: Supply side potable water, not wastewater. Gray Water/Sewage: Wastewater originating from a drain (sink, toilet, urinal).

PA HEALTHY & GREEN MINI-GRANT APPLICATION TIPS

Installation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)

UNITOR VACUUM cleaners

FACT SHEET : Using Autoclaves Safely

Transcription:

Mercury Vapor Emission from Broken Compact Fluorescent Lamps and Cleanup procedures Raj Singhvi USEPA/ERT, Edison, NJ, 08820 Singhvi.Raj@epa.gov; 732-321-6761 A. Taneja Department of Chemistry, St. John s College, Dr. B R Ambedkar University, Agra, India J. Patel, D. Kalnicky, C. Gasser Lockheed Martin/SERAS, Edison, NJ, 08837

INTRODUCTION - Compact fluorescent lamps (CFLs) replacing incandescent lamps - Concern: use of CFLs may adversely affect human health - Potential for mercury (Hg) release if CFL is broken - Relevant to policy efforts to phase out incandescent lamps - Need comprehensive information database for policymakers - CFL mercury content approximately 2 to 5 milligrams - NEMA proposed reduction in max from 5 to 4 mg (NEMA, 2010) - Green Seal Standard (Green Seal, 2009); encapsulated dosing methods to minimize worker exposure during CFL manufacture - Cleanup/disposal methods for the general public not standardized - More data needed to standardize guidance

MATERIALS Chamber: 24 x 18 x 24 (width x length x height) acrylic chamber two compartments (Fig 1), each 24 x 18 x 12, effective compartment volume 2.53 ft 3 (0.0716 m 3 ) CFL samples: Five popular different spiral CFLs selected based on mercury content Real-time Mercury Vapor Measurement: Mercury Tracker 3000 Analyzer; portable instrument; Hg concentration in µg/m 3

Figure 1. Acrylic chamber used for mercury vapor emission studies

EXPERIMENTAL DESIGN All measurements performed at 72 +/- 2 o F. Mercury Loss From Broken CFLs on Plastic. - Used one compartment of the acrylic chamber - CFL in middle of piece of vinyl sheet in cardboard tray in chamber; CFL smashed into small pieces (Fig 2) - Hg vapor monitored with Mercury Tracker 3000; air flow from the chamber 1.5 L/min (exchange rate of 1.25/hour) - Hg vapor measurements logged every 15-sec for 24-hours - Experiment repeated two additional times (triplicate) - Four other types of CFLs measured in the same fashion

EXPERIMENTAL DESIGN, cont d All measurements performed at 72 +/- 2 o F. Mercury Loss From Beads - Metallic mercury weighed in plastic dish, placed in chamber, Hg vapor monitored using Tracker 3000 - Used various weights (comparable to mercury content in CFLs) of single beads or two beads of Hg Mercury Loss From Broken CFLs on Carpet - Performed for each of the five different types of CFLs - Same compartment of the acrylic chamber - Same conditions as for broken CFLs on plastic

CLEANUP - Cleanup procedures performed between individual experiments to remove CFL debris - Adequate to start the next experiment when the Hg vapor concentration was less than 0.1 µg/m 3

Figure 2. Broken CFL (on plastic) in the chamber

CFL BROKEN ON PLASTIC - Table 1: Percent Hg loss for five CFL bulb types on plastic - Fig 3: Plots of emission data (average of triplicate runs for each bulb type) - Average 24-hr Hg loss from broken CFLs 0.6% to 22% - Hg loss not directly related to Hg content or how Hg is incorporated in the bulb (metallic or amalgam) - Location of the Hg in the bulb, how bulb is broken, ambient temperature may affect emission after breakage

Table 1. 24-Hour Mercury Loss from CFLs Broken on Plastic CFL Bulb Type Hg content (mg) a Average Concentration (µg/m 3 ) b Total Hg Emitted (µg) % Hg Loss B-23W 2.57 7.4 15.9 0.6 G-15W 2.42 200 432 18 N-14W 2.18 217 471 22 P-13W 4.75 213 461 9.7 S-13W 1.22 12.4 26.8 2.2 a CFL average mercury content (Singhvi, et al., 2011) b Average of three measurements for each bulb type B, G, N, P Mercury in bulb as metallic mercury S Mercury in bulb as an amalgam

Figure 3. Mercury concentration vs. time for CFLs broken on plastic.

PROJECTED HG CONC FROM CFLs BROKEN ON PLASTIC - Table 2: Hg concentrations projected for breakage of CFL bulbs in a 12 x 9.33 x 8 room (25.4 m 3 ) at air exchange rate of 1.25 - Projected concentrations for the B-23W and S-13W bulb types are below the ATSDR minimum risk level of 0.2 µg/m 3 (ATSDR, 2000) - Values for the G-15W, N-14W, and P-13W bulb types are above the ATSDR risk level

Table 2. Projected Mercury Concentration for CFLs Broken on Plastic in a Room a CFL Bulb Type Hg content (mg) Projected Avg. Conc. for 1.25 Exchanges/hour (µg/m 3 ) b B-23W 2.57 0.021 G-15W 2.42 0.58 N-14W 2.18 0.62 P-13W 4.75 0.61 S-13W 1.22 0.035 a Room dimensions: 12 x 9.33 x 8 (25.4 m 3 ), 24-hour average values b Predicted based on measured average concentration (Table 1) scaled to room volume using a previously developed model (Singhvi, et al., 2005) B, G, N, P Mercury in bulb as metallic mercury S Mercury in bulb as an amalgam

MERCURY LOSS FROM BEADS - Table 3 and Fig 4: Mercury loss from beads with different weights - Projected 24-hour Hg loss (0.4% to 0.9%) much lower than that for CFLs with comparable Hg content - Hg may emit at a higher rate from a broken CFL compared to a bead with the same weight of Hg - Reason not clear; may be due to larger surface area or the presence of mercury vapor in the CFLs

Table 3. Mercury Loss for Beads Bead weight (mg) Run Time (hours) Average Concentration (µg/m 3 ) b Total Hg Emitted (µg) % Hg Loss (24 hours) a 2.90 5.6 11.8 5.93 0.9 3.10 4.6 11.8 4.89 0.8 3.72 6 6.4 3.47 0.4 2.95 b 6 8.8 4.76 0.6 2.12 b 6 9.0 4.87 0.9 a Projected percent mercury loss for 24-hours b Total weight for two beads

Figure 4. Mercury concentration vs. Time for different bead weights.

CFL BROKEN ON CARPET - Table 4: Percent Hg loss for five CFL bulb types on carpet - Fig 5: Plots of the emission data - Avg. 24-hour Hg loss from broken CFLs 2.6% to 28%; not directly related to the Hg content or how Hg is incorporated in the bulb (metallic or amalgam) - Avg. emission and mercury loss higher for breakage of CFLs on carpet compared to plastic except for the N- 14W CFL bulb type

Table 4. 24-Hour Mercury Loss from CFLs Broken on Carpet CFL Bulb Type Hg content (mg) a Average Concentration (µg/m 3 ) Total Hg Emitted (µg) % Hg Loss B-23W 2.57 31.1 67.8 2.6 G-15W 2.42 309 677 28 N-14W 2.18 201 431 20 P-13W 4.75 245 529 11 S-13W 1.22 21.2 45.8 3.8 a CFL average mercury content (Singhvi, et al., 2011) B, G, N, P Mercury in bulb as metallic mercury S Mercury in bulb as an amalgam

Figure 5. Mercury concentration vs. Time for CFLs broken on carpet.

Clean up Procedures Open the window where CFL is broken immediately Wear kitchen rubber gloves to collect broken pieces of bulb using two card board pieces in garbage bag and/or a glass container On the carpet use lint remover, duct tape, pizza dough or chapatti dough (in India) can also be used to remove the small Phosphor particles / mercury left on the carpet On tiles use clorox wipes to clean the floor Collect all the material in the garbage bag and double bag it, if glass container is not used Leave the bag or container out side the home. Dispose the waste material as per local laws Wash your hands with soap and lot of water A vacuum is not recommended for removing the debris as air movement may cause further distribution of mercury and contaminate the vacuum cleaner See now two video clips for clean up.

Broken CFL on Carpet- Clean up Video

Broken CFL on Tiles- Clean up Video

CONCLUSIONS - CFL Hg vapor emissions may be significantly greater than from beads of liquid mercury with comparable weights - Avg. 24-hour Hg loss for CFLs broken on plastic 0.6% to 22%; not directly related to the mercury content or how mercury is incorporated in the bulb (metallic or amalgam) - Avg. 24-hour Hg loss from CFLs broken on carpet 2.6% to 28% - Reason for increased emission and mercury loss from CFL breakage on carpet compared to plastic is not clear and will be investigated in future work

CONCLUSIONS, cont d - 24-hour Hg loss for liquid mercury beads much lower than for CFLs with comparable mercury content; location and form of the mercury in the bulb, how the bulb is broken, ambient temperature may affect emission after breakage - Projections for a 12 x 9.33 x 8 room (25.4 m 3 ); CFL breakage may produce 24-hour mercury concentrations above the ATSDR minimum risk level of 0.2 µg/m 3 (ATSDR, 2000) - If appropriate procedures are implemented for cleanup, it is unlikely that breakage of a CFL will have any health effect.

ACKNOWLEDGEMENT The authors wish to acknowledge the assistance of the following: Dennis Miller and Donna Getty of Lockheed Martin/SERAS; and Jeff Heimerman, David P. Wright, and Harry R. Compton of USEPA for management support. The authors are also thankful to Deborah Killeen of Lockheed Martin; and Ellie McCann, of USEPA, for their expertise in reviewing the manuscript. DISCLAIMER Mention of trade names or commercial products does not constitute endorsement or recommendation for use.

REFERENCES ATSDR (Agency for Toxic Substances and Disease Registry), 2000. Minimal Risk Levels (MRLs) for Hazardous Substances. Available at http://www.atsdr.cdc.gov/mrls.html. NEMA (National Electrical Manufacturers Association), 2010. Limits on Mercury Content in Self-ballasted Compact Fluorescent Lamps, Standard Publication LL 8-2010. Singhvi, R., Y. Mehra, J. Patel, D. Miller, and D. Kalnicky, 2005. Ritualistic Use of Mercury - simulation: A Preliminary Investigation of Metallic Mercury Vapor Fate and Transport in a Trailer. OSWER 9285.4-08, EPA/540/04/006. Singhvi, Raj; Taneja, Ajay; Patel, Jay R.; Kansal, Vinod; Gasser, Charles J.; and Kalnicky, Dennis J., 2011. Determination of Total Metallic Mercury in Compact Fluorescent Lamps (CFLs), Environmental Forensics 12:2, 143-148.