1 Electric motor operating principles and circuits

Similar documents
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

All about Motors. Page. Motor protection 8-3. Notes on engineering Circuit documents Power supply Control circuit supply 8-24

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Thermistor motor protection

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Motor Protection Voltage Unbalance and Single-Phasing

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Industrial Controls SIRIUS Controls

Data Sheet. AC Industrial Electric Motors

Three-phase AC circuits

EET272 Worksheet Week 8

Three phase circuits

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

ELECTRONIC POWER SYSTEMS

Specifying a Variable Frequency Drive s

FREQUENCY CONTROLLED AC MOTOR DRIVE

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

Unit 33 Three-Phase Motors

Reverse-feed applications for circuit breakers

Speed Control Relays SX2

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

MOTOR PROTECTION AGAINST SINGLE-PHASING

HERZ-Thermal Actuators

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Single Phase Soft Starter

DC Motor control Reversing

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

*.ppt 11/2/ :48 PM 1

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

ABB i-bus KNX Fan Coil Controller FC/S 1.1

How To Understand The Electrical Power Supply Of A Power Supply System

4chapter. AC motors starting and protection systems

Unified requirements for systems with voltages above 1 kv up to 15 kv

DIRECT CURRENT GENERATORS

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

8 Speed control of Induction Machines

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

PNEUMATIC CONTROLS Selection and Description

Digi-Motor Installation Guide

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Electrical Symbols and Line Diagrams

Automatic Voltage Regulator User s Manual

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

COOL-01, Cooling Fan Operation and Troubleshooting

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Earth Fault Detection Basics in Theory

SX460. Generator Automatic Voltage Regulator Operation Manual

Electric Motor Brake Horsepower Calculations

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

PHASE CONVERSION TECHNOLOGY OVERVIEW

Rotary Phase Converters

SPEED CONTROL SYSTEM

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

E2 Series Electric Furnaces

Chen. Vibration Motor. Application note

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

chapter6 Electrical machines and motors Unit 1 outcome 6

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Motor Fundamentals. DC Motor

Why and How we Use Capacity Control

IV. Three-Phase Induction Machines. Induction Machines

Safety technique. Emergency stop module BO 5988 safemaster

7. Reactive energy compensation

SHIP SERVICE GENERATORS (AC)

DANGER! HIGH VOLTAGE HAZARD

Three-phase monitoring relay CM-PFE

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

AC Induction Motor Slip What It Is And How To Minimize It

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Offshore Platform Powered With New Electrical Motor Drive System

Three-phase asynchronous motors Generalities and ABB proposals for the coordination of protective devices

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Data Sheet. Electro-mechanical counters Hengstler 800 series

Kit Watt Audio Amplifier

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

White Paper - July ATS021-ATS022 Automatic transfer switching

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

EET272 Worksheet Week 9

Principles of Adjustable Frequency Drives

Transcription:

1 Electric motor operating principles and circuits Thomas Feick, Bad Hersfeld Electric motor operating principles and circuits 120 Stator Rotor with windings 400 V 400 V Three-phase and singlephase a.c. systems S V2 V1 230 V 230 V 400 V In electrical power supply technology, a basic distinction is made between single-phase and three-phase a.c. mains systems. The differences between these two systems are outlined below. Fig. 1 W2 W1 230 V Three-phase a.c. Three-phase a.c. (alternating current) is produced by generators and passed to electric power consumers via appropriate conductors. The mains system itself consists of the three current-carrying conductors, and, a neutral conductor, and the protective earth conductor PE. In a three-phase a.c. mains system designated 400 V 3/ ~ 50 Hz (the variety most commonly used in Europe), the following voltage relations exist: A voltage of 400 V is present across conductors -, - and -. The voltage between conductors -, - and - is 230 V in each case (refer to Fig. 1). Single-phase a.c. In a single-phase a.c. system, a voltage is carried between the live or phase conductor and the associated neutral conductor. It does not matter which of the three phases is used for the live conductor. It will be appreciated from Fig. 1 that a three-phase a.c. mains system with a neutral conductor and a voltage of 400 V also provides a 230 V single-phase mains supply. The quotient of the phase-tophase voltage and the phase-to-neutral voltage is expressed by the socalled interlinking factor. The interlinking factor is calculated as follows: Voltage between 2 phases 400V = = 1,73 = 3 Voltage 230 V between 1 phase and This interlinking factor of 1,73 = 3 applies to all three-phase a.c. networks having a neutral conductor, regardless of their nominal voltage. Three-phase a.c. motors Let us now consider the options for connecting electric fan and air heater motors to the above a.c. mains systems. As a basic rule, the availability of an electrical mains system is a precondition for connecting any item of HVAC equipment comprising an electric motor. To operate the motor on this power supply, the two must be matched, i.e. the mains voltage and motor operating voltage must be the same, as must be their frequencies. Single-speed three-phase a.c. motors with dual voltage specification Fig. 2 V1 W1 W2 V2 Some three-phase a.c. motors for single speed operation have a dual voltage specification, e.g., 230/400 V or 400/90 V. Terminal designations for such motors are given in Fig. 2. The 230/400 V specification states that the motor can be run on 230 V three-phase a.c. or on a 400 V threephase a.c. network. Since the mains voltage is usually fixed, i.e. not freely selectable, the motor circuit can be adapted to specific application needs. Each individual winding of this motor is rated for a voltage of 230 V. However, by adopting either a star or delta connection, it is possible to run it on either 230 V or 400 V. In a star connection windings are connected as shown in Fig. 3. The illustration clearly shows the star pattern in which the windings are interconnected. The associated diagram of the terminal board indicates where the feeder must be terminated and where the star connection is placed. Here, again, the interlinking factor between the 230 V winding voltage and the 400 V mains voltage is 1.7 = 3 With any other winding voltage, mains voltage in the star circuit must be equal to 1.7 = 3 times the winding voltage.

Electric motor operating principles and circuits 2 The interconnection of windings in a delta-connected motor corresponds to the diagram in Fig. 4. The illustration clearly shows the triangular (delta-shaped) connection pattern. The associated diagram of the terminal board indicates where the power supply must be terminated and where the delta connections are placed. A comparison of the two connection methods reveals that, for each winding to receive a voltage of 230 V at all times, the motor windings must be connected in a star pattern on a 400 V a.c. mains system or in a delta pattern on a 230 V a.c. supply. We can thus state the following general rule: On machines with a dual voltage specification, a star connection must be used for the higher voltage. A delta connection is indicated for the lower voltage. The machine s direction of rotation can be reversed by interchanging any two phases. Dual-speed three-phase a.c. motors with single voltage specification A distinction is made between a) pole-changing motors according to Dahlander (rotational speed ratio of 1:2) b) pole-changing motors with two separate windings (permitting other rpm. ratios than 1:2). Unlike their single-speed counterparts, dual-speed motors are always designed for a single operating voltage. Mains voltage and nominal motor voltage must coincide. As regards the designation of terminals, it has been determined by convention that the sequence of the numerals preceding the terminal letters indicates the rpm. level, i.e., terminals, and are always for lower speed while the terminals, and are for higher speed. Figs. 5 to 8 (see next page) indicate how the windings must be interconnected and where the live conductors are terminated in each case. V1 W1 W2 V2 W2 V2 W1 V1 W2 V1 W1 W1 V2 V1 W2 V2 Fig. 3 Fig. 4

3 Electric motor operating principles and circuits Dahlander winding To run the machine at lower rotational speed, power supply is connected to terminals, and. The other terminals (,, ) remain unconnected (Fig. 5). To use higher speed, power supply is assigned to terminals, and. Important: Terminals, and must be interconnected in this case. Failure to provide this jumper ( star connection ) will result in destruction of the windings (Fig. ). In contactor-controlled systems, the star contactor must always be switched on before the mains contactor for the high speed! Two separate windings Dahlander winding (low speed) Dahlander winding (high speed) Here, again, power supply is connected to terminals, and for the lower speed, with terminals, and remaining unconnected (Fig. 7). For higher speed, the power supply must be wired to terminals, and. Fig. 5 Fig. A star connection ( jumper ) must not be used in this case. Two separate windings (low speed) Two separate windings (high speed) Failure to observe this rule would result in destruction of the windings. From the comparison of the connecting diagrams for motors with Dahlander winding and units with separate winding, it becomes clear that the difference between the circuits must be carefully noted when selecting switching devices. A switching device for a Dahlander motor must never be used on a motor with two windings and vice versa! Once again, two phases are interchanged to reverse the motor direction. If a pole-changing switch ( pole changer ) is used, it is recommended to effect phase interchange upstream of the switching device since changing phases on the motor would involve re-wiring 2 x 2 terminals, i.e. the risk of confusing conductors is much higher in this case. Fig. 7 Fig. 8

Electric motor operating principles and circuits 4 Single-phase a.c. motors Single-phase a.c. motors are available for single- or multi-speed operation, or stepless rpm. control. The motor terminal board with its terminal designations and connections for windings and capacitors is depicted in Fig. 9. Such motors are designed for a 230 V operating voltage only. It is immaterial whether the motor is connected between a phase and neutral () of a 400 V mains system or between two phases of a 230 V supply. Moreover, when connecting phase and neutral () conductor, it does not matter which terminal is used for either. Direction of rotation will be the same. A change in operating direction can be achieved by reversing the auxiliary versus the main winding. This involves rewiring the jumpers on the terminal board. Since jumpers between and Z1 and between Z2 and C1 are permanently provided on the terminal board, direction of rotation is defined. The speed can be selected via an appropriate assignment of the power supply terminals. 1. Low speed It is evident from the diagram that the main winding HS is connected in series with the auxiliary winding HIS. The motor capacitor C is connected in parallel with the auxiliary winding (Fig. 10). 2. High speed It will be appreciated from this diagram that the main winding HS is connected in parallel with the auxiliary winding HIS, while the motor capacitor C is connected in series with the auxiliary winding (Fig. 11). These motors can also be steplessly speed controlled via an rpm. controller. In this case the circuit configuration for the higher speed must be adopted and the controller be connected to the motor terminals and. Z1 Z2 C C1 PE HS HIS Main winding(s) Auxiliary winding(s) Motor capacitor Fig. 9 C Z1 C HIS HS C1 Z2 Z1 Z2 C C1 PE Fig. 10 Z1 HIS HS Z1 Z2 C C1 PE Z2 C1 C C Abb. 11

5 Electric motor operating principles and circuits Switching devices for a.c. motors The function of switching devices is essentially twofold, viz. 1. to energize and de-energize the fan motor. 2. to protect the motor from overloads and hence, destruction. Switching devices performing this latter function are referred to as motor protecting switches or protecting switch combinations. Motor protecting switches for single-speed motors without thermal contact A motor protection switch can operate a single-speed three-phase a.c. motor. It comprises a switching and tripping mechanism. The tripping mechanism (overcurrent or bimetal relay) responds to the motor input current and interrupts the power supply when the current consumption begins to exceed the motor s nominal current. The motor s nominal current at the relevant operating voltage is the decisive factor for selecting a motor protecting switch! The nominal current must lie within the setting range of the protecting switch thus the latter to be accurately adjusted to the motor s nominal current. The protecting switch must not trip the motor unless the preset current is exceeded. On the other hand, the motor must be switched off (after a certain delay) when its current consumption rises above the setpoint of the protecting switch. The delay preceding this shutoff becomes shorter as the current increases; it amounts to about 5 seconds at times the preset current. It is implied in the foregoing that the measured current is taken as a measure of the motor temperature. However, this is true only as long as the motor coolant temperature remains below a threshold of +40 C. If the coolant temperature rises beyond +40 C, the motor may be destroyed even if its nominal current is not exceeded, simply because the heat generated inside cannot be dissipated quickly enough. A motor protecting switch merely responds to the motor load, relying on the fact that the current rises with the load. The current is the cause of the heat increase. Motor protecting switch combinations for dual-speed motors without thermal contact Dual-speed motors are switched via protecting switch combinations. The latter differ from simple protecting switches in that they comprise two tripping mechanisms (overcurrent or bimetal relays) as well as an rpm. switch. However, the operating principle is much the same as with a motor protection switch for single-speed machines. Full motor protecting switching devices for motors with thermal contact For a truly effective motor protection, the influence of the cooling system must be taken into account. This is achieved by measuring the temperature directly at the point where it can harm the motor, i.e. within the winding. Winding insulations come in different classes and must not be allowed to overheat beyond the limit temperature specified for each class. For the temperature measurement, a temperature sensor (thermal contact) acting as a control transducer is integrated into the winding. The temperature in the motor winding is reliably determined by this sensor. It consists of a very small bimetallic switch that interrupts an electric control circuit shortly before the winding temperature reaches the limit for the given insulation class. To benefit from this feature, an appropriately equipped switching device must be used. These devices as referred to as full motor protection switches for motors with thermal contact. They are availa- C 200 180 C 10 120 80 40 15 C 155 C 15 C 5 C 130 C 120 C 10 C 105 C GÜT 0 C 75 C 80 C 100 C 125 C GT HDT S = Safety margin KT = Coolant temperature GÜT = Temperature rise-limit GT = Limit temperature HDT = Max. permissible continuous temperature 40 C 40 C 40 C 40 C 40 C KT A E B F H Insulating material classes Fig. 12

Electric motor operating principles and circuits ble for single-speed motors with Dahlander windings or with two separate windings. The control action of a full motor protection switch is characterized by the fact that the motor is de-energized immediately when the thermal contact is tripped, interrupting the electric control circuit. However, the motor will not re-start automatically when the control circuit is closed again by the thermal contact. To re-start the motor, a manual switch must be set first to 0 and then, via E (this gives the starting pulse), to position 1 or 2 according to the desired speed. Some full motor protection switches have additional contacts for a servo motor and a port for connection of a contact-making component (e.g. a thermostat, hygrostat, timer, etc.). Such switches can be used to energize and de-energize the motor via a contact-making component at a manually preselected speed. The motor is shut off when the control contact opens and re-starts automatically when it closes. The additional contacts allow to run a servo (positioning) motor in a clockwise or counterclockwise direction independently of the fan motor. While a motor protecting switch combination with a bimetal relay set to the nominal motor current can serve only one single connected motor, a full motor protection switching device for motors with thermal contact supports the connection of multiple motors. It should be noted, however, that the aggregate outputs of these motors must not exceed the maximum acceptable capacity of the full motor protection switching device. Moreover, motors thus connected in parallel must have the same operating voltage and winding type (single-speed, Dahlander or separate windings). The circuit configuration must be such that motors are connected in parallel with their three-phase a.c. terminals while the thermal contacts are connected in series. Switching devices for singlephase a.c. motors Single-phase a.c. motors can be classified according to the following scheme: 1. Motors with thermal contacts wired to external terminals 2. Motors with internally wired thermal contacts. Internally wired thermal contacts (i.e. contacts placed in the winding and inserted directly into the motor circuit) are suitable for use on low-powered motors only. Motors equipped with such contacts can be started and de-energized via any commercially available installation switch, provided they are of the single-speed type. For dual-speed motors a special rotary switch must be used; such switches fit into any standard flush-mounting enclosure. Motor protection will be ensured at both speeds and in both operating modes. The thermal contact interrupts the motor circuit when the winding temperature reaches the acceptable limit for the given insulation class, then re-starts the motor once it has cooled down. As an alternative to the above, a contactor-controlled system can be designed to prevent an automatic restart once the motor temperature has returned into the acceptable range. As a general rule, motors with internally wired thermal contacts can also be operated via witching devices designed for separate connection of a thermal contact. In this case terminals for this thermal contact must be shortcircuited via a jumper on the switching device. Irrespective of whether or not the motor has its thermal contacts wired to external terminals, single-phase a.c. units can be steplessly speed-controlled via an electronic rpm. controller developed specifically for this motor type. This speed controller also allows to define two or three speed stages for the motor by connecting appropriate resistors to the control circuit. A changeover between speeds is then made via a component supplying a contact output. The motor is energized and de-energized via a manual switch integrated into the controller.