Mounting Instructions for Navigation Lights aqua signal 55

Similar documents
Operating Instructions

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Cross-beam scanning system to detect slim objects. 100 mm in

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Wind Direction Smart Sensor (S-WDA-M003)

1. Description. 2. List of Accessories included A B C F G H

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Saferand easierinstallation

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

Traditional Sonar and DSI Sonar Installation

Explosion proof enclosures

Wetroom Panel (Concealed Fix)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Transducer Installation

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Model CS 64 Mini-DIN Cable and Adaptor

Electric Rotary Actuator - On/Off or programmable control actuator

Remote Head REMO ONE. Code Manual

Folding Bath Screen Instruction Manual

PITCHED ROOF STRUCTURES

This instruction is valid for all ACD pump models shown on page 2

Linkeo 19" freestanding cabinets

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Proportional pressure regulators VPPE

Important Information

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

TELESCOPE Motorized Lighting Suspension

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Terminal Boxes Series 8146

kymanual or Automatic - it s your Choice

MCA Survey of Lights and Signaling Equipment - Instructions for the Guidance of Surveyors. Index

Operating Instructions

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Maintenance and Service Instruction

INTERNATIONAL ANNEX III. Technical Details of Sound Signal Appliances

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

F-Series Camera Mounting Accessories

Linear Luminaire with LED Series EXLUX 6402/2

StructureScan Installation

Series 6000 Torque measured metal bellow coupling

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Jet Propulsion System

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

3/2- and 2/2-way cartridge valve type BVE

Pigeon Spike Stainless Economy Bird Spikes Includes specifications for: Pigeon Spike Stainless models, hardware and surface cleaning.

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

CRASH RAIL INSTALLATION HEIGHT

TotalScan Transducer Installation manual

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Operators manual Basic water heater

Givare NC-SRS 280 och 880

Part Name/Description Part Number Quantity. Power Cable

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ASSEMBLY INSTRUCTIONS Residential Roof solutions

Operating instructions for Electrode sharpening machine WIG 4

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

SIMRAD SD10 Sailboat Drive

Marine Order 4 (Transitional modifications) 2013 provides for this Order to have effect and makes modifications for it.

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

MultiPost-AP anchorage device

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

JP Tribander Owner Manual

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Flamco Stainless steel mountings

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Owner s Manual

DATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

OCTOPUS SELECTION & INSTALLATION GUIDE

Quick Connect Boxes Inside Gloveboxes

GPS AutoSteer System Installation Manual

Infrarot-Bewegungsmelder IP44

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

INSTALLATION INSTRUCTIONS: Viewline 52 mm

POPUP DISPLAY SYSTEMS

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

1-Way Bracket Assemblies

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

SureSite Magnetic Liquid Level Indicator

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

IMPORTANT INFORMATION

Guideline Laser Series

Machine devices, jig devices

2.4M SERIES 1241 ANTENNA

HERZ-Thermal Actuators

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

INTERNATIONAL TECHNO 293 CLASS RULES

Transcription:

Mounting Instructions for Navigation Lights aqua signal 55-1 -

Mounting Instructions for Navigation Lights Type AQUA SIGNAL 55 These navigation lights comply with the national and international regulations (IMO 1972) regarding minimum range of visibility, luminous intensity of horizontal and vertical sectors, and color specifications for vessels >20 - < 50 meter in length (Regulations for Preventing Collisions at Sea). Lights marked D in addition to DHI resp. BSH marking may be utilized on European inland waterways. However, the correct functioning of the lanterns in accordance with the rules can only be ensured when some important points regarding mounting and maintenance have been considered. It is therefore essential to study the following pages attentively. Regulations For all ships the rules set forth in Annex 1 to the International Regulations for Preventing Collisions at Sea Positioning and Technical Details of Lights and Signalling Shapes must be adhered to. The technical data regarding horizontal and vertical positioning and spacing of the navigation and signalling lights laid down in these mounting instructions do apply to all ships irrespective of their flag. aqua signal 55 Masthead light Mounting of navigation lights in general* The lights must be positioned in and above the keel line resp. parallel with it. Their horizontal plane (A) must be parallel with the construction water line (CWL). Their light must not be obstructed by parts of the vessel or objects or persons aboard. Their relative positions to the vessels are not to be changed while in operation. *Deviating from the anti collision regulations the forward masthead light needs to be fitted only 5 meters above the hull and the after masthead light just 3 meters higher if the vessel is designed and registered for operation on European inland waterways until the border of high seas navigation. Minimum distance if mounted in vertical line for main - and sparelighting A = horizontal plane CWL = construction waterline - 2 -

right ahead direction screening of sidelights screen screen spill-over light source Mounting Instructions The navigation and signalling light AQUA SIGNAL 55 are in conformance with the IMO regulations 1972 and approved by the respective national authorities. For approval number and manufacturers type designation look at the nameplate. Sidelight AQUA SIGNAL 55 green-strong resp. red-strong angle 112,5 visibility 2 nm The light must be fitted with its horizontal plane (A) parallel with the CWL. Pay attention to the right ahead direction mark of the light that must be parallel with the keel line and conform with the ship s marking. It is important to respect the dimensions shown in. The measurement x must precisely be adhered to since otherwise the light intensity in the right ahead direction maybe reduced. Masthead light AQUA SIGNAL 55 white-strong angle 225 visibility 5 nm The light must be fitted with its horizontal plane (A) parallel with the CWL. Pay attention to the right ahead direction mark of the light that must be parallel with the keel line and conform to the ship s marking. For precise mounting refer to. right ahead direction keel line Stern light AQUA SIGNAL 55 white-strong resp. yellow-strong angle 135 visibility 2 nm The light must be fitted with its horizontal plane (A) parallel with the CWL. Pay attention to the right ahead direction mark of the light that must be parallel with the keel line and conform to the ship s marking. For precise mounting refer to. lights s back parallel thwartships lights s back parallel thwartships keel line right ahead direction - 3 -

Signalling light AQUA SIGNAL 55 white-, red-, green-strong angle 360 visibility 2 nm Signalling lights maybe positioned solidly mounted or variably. In case of solid mounting attention has to be paid that their sector will not partly be obstructed by the vessel to a greater extend than negligible. At any event the sector of obstruction may not exceed 6. The graph reveals the distance d mast center to light center. In case two signalling lights white are fitted as anchor lights they must be positioned in a way that one of them can be seen from all over the horizon. In case 2 or 3 signalling lights shall be fitted in a vertical line the distance amongst them must at least be 2 meters. 2 m min. distance Graph to determine the min. distance d to keep Alpha 6-4 -

aqua signal 55 Connection cable The navigation lights AQUA SIGNAL 55 as standard are equipped with one cable of 1,5 meters in length (Type HO 7 RN.F). AQUA SIGNAL 55 As standard the cable is fed in from the side. If cable should be fed in from underneath the necessary cable gland can be ordered under ref. no. 8351001. If cable needs to be replaced see. Incandescent bulbs and how to change them AQUA SIGNAL 55 There are 2 different bulbs available, 12V and 24V. These lights are to be operated exclusively with special approved bulbs. These special bulbs from AQUA SIGNAL are labeled as follows: 25W ZP D1302/1304. For vessels under American or Chinese flag a 120V bulb is available as well. The bulb socket BAY 15d ensures the correct position of the bulb in the light. To change the bulb disconnect the plug. The bulb change is done from the top. Assembling of screw-set Maintenance All the components of the light are made of seawater resistant materials and need no particular maintenance except occasional cleaning. For cleaning just take fresh water and a soft cloth or sponge, by no means solvents or abrasive substances like e.g. steelwool or scouring sand. Important Navigation light housings are not to be painted for photometric reasons. Especially the optics and other parts like shades must not be covered with paint. Assembling of screw set 1. stainless steel screw M 8 x 45 2. stainless steel washer Ø 8,5 3. plastic washer Ø 8,5 4. mounting console 8 mm minimum or with appropriate support 5. lock washer Ø 8,5 6. stainless steel nut M 8 max. torque 50Nm (= 5 Kpm) Clamp cage Rubber sealing Pressing screw - 5 -

Spare Parts / *Extras - 6 -

aqua signal reserves the right to modify their products without prior notice to not impede progress in technology or design. ATTENTION Bulbs for Navigation Lights The bulbs used in Navigation Lights are part of the approval/certification. Bulbs which are non-approved null-invoid your insurance cover as your lights will not be in line with the regulations/certification. We recommend to use approved material only since this is in the interest of your safety. 55_13_GB aqua signal Aktiengesellschaft P.O.Box 45 01 61 D-28295 Bremen, Germany Phone:+49 421 48 93-0 Fax: +49 421 48 93 210/- 310 e-mail: info@aquasignal.de Internet: http://www.aquasignal.de - 7 -