Amount of refrigerant

Similar documents
ON-VEHICLE INSPECTION

AIR CONDITIONING PRESSURE SWITCH... HEATER MAIN RELAY... MAGNETIC CLUTCH RELAY... COOLING FAN RELAY... CONDENSER FAN... AIR REFINER FILTER...

DTC B1423/23 Pressure Sensor Circuit

AIR CONDITIONING SYSTEM PRECAUTION

AIR CONDITIONING SYSTEM

AIR CONDITIONING CONTROL ASSY

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

AIR CONDITIONING SYSTEM

HEATER, AIR CONDITIONER AND VENTILATION <MANUAL A/C>

AIR CONDITIONING GENERAL... 2 HEATER... 7 BLOWER... 9 VENTILATOR AIR CONDITIONING SYSTEM AIR CONDITIONING SERVICE COMPRESSOR...

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

A/C refrigerant system, overview

HVAC-02, Air Conditioning Troubleshooting and Repair

HVAC. (w) HVAC SYSTEM. Blower unit. (See BLOWER UNIT REMOVAL/INSTALLATION.) (See BLOWER UNIT DISASSEMBLY/ASSEMBLY.) Air filter

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SERVICE MANUAL. Valeo TM31 Compressor. Copyright 2014 Valeo Japan CO., LTD. All rights reserved.

HEATER & AIR CONDITIONER SECTIONHA CONTENTS

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Air Conditio. Subaru Air Conditioning Systems. End Wrench

01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N A

EM REMOVE NO. 2 MANIFOLD STAY (a) Remove the bolt, nut and stay.

Recharge Procedure for Telemark TVP-2000 and TVP-3500

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

How To Diagnose And Fix A Car With A Power Control Unit

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

HEATER, AIR CONDITIONER AND VENTILATION

LOBOY 16 AIR CONDITIONERS

Central Air Conditioning Plants

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Cooling system components, removing and installing

SERVICE MANUAL. Valeo TM21Compressor. Copyright 2015 Valeo Japan CO., LTD. All rights reserved.

14. Troubleshooting Guide

ENGINE COOLING SYSTEM

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

MIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

AIR CONDITIONING SYSTEM (FOR AUTOMATIC AIR CONDITIONING SYSTEM)

HEATER, AIR CONDITIONING AND VENTILATION

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

MACS Recommended Service Procedures

CARING FOR YOUR WATER HEATER

Aerosphere Midibus. Air Conditioning System. Operation Manual. Aerosphere Midibus 05/2013 P.N A

AIR CONDITIONING SYSTEM

accidents which arise due to nonobservance and the safety information herein.

ASE 7 - Heating, Ventilation, and Air Conditioning. Module 8 Diagnosis, Testing & Repair

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

COURSE OUTLINE. Course Title Automotive Air Conditioning. Co- or Pre-requisite AUT 110, AUT 111

Chapter 7 Hydraulic System Troubleshooting

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Cooling system components, removing and installing

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Evaluate, Clean, and Tune Guidance

Cooling system components, removing and installing

123 street Salt Lake City, Utah 84092

Failure code manual. content

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

OPERATING AND MAINTENANCE INSTRUCTIONS CLIMATE CONTROL/INDUSTRIAL

Draining and filling cooling system

PORTABLE AIR CONDITIONER

Heating and Air Conditioning

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Flushing and Cleaning the A/C System

T-Series Air Conditioner T62 Model

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Air Conditioning Operation & Diagnosis

SERVICE MANUAL. Valeo TM08, TM13, TM15 & TM16 Compressors. Copyright 2015 Valeo Japan CO., LTD. All rights reserved.

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Compressor Service & Maintenance Manual

Cooling system components, servicing

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

9. Heater Core HEATER CORE HVAC SYSTEM (HEATER, VENTILATOR AND NC)

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Your safety and the safety of others are very important.

Table of Contents. First Aid for Refrigerant Exposure 35. First Aid for Skin Exposure / First Aid for Eye. Chapter 3:

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Transcription:

AIR CONDITIONING SYSTEM AC15 REFRIGERATION SYSTEM INSPECTION OF REFRIGERANT VOLUME 1. RUN ENGINE AT APPROX. 2000 RPM 2. OPERATE AIR CONDITIONING AT MAXIMUM COOLING FOR A FEW MINUTES 3. CHECK AMOUNT OF REFRIGERANT Observe the sight glass on the receiver. Item Symptom Amount of refrigerant Bubbles present in sight glass Insufficient (1) Check for gas leakage with gas leak tester and repair if necessary (2) Add refrigerant until bubbles disappear No bubbles present in sight glass None, sufficient or too much Refer to items 3 and 4. No temperature difference between compressor inlet and outlet Empty or nearly empty (1 ) Check for gas leakage with gas leak tester and repair if necessary (2) Add refrigerant until bubbles disappear Temperature between compressor inlet and outlet is noticeably different Proper or too much Refer to items 5 and 6 Immediately after air conditioning is turned off, refrigerant in sight glass stays clear Too much (1) Recover refrigerant (2) Evacuate air and charge proper amount of purified refrigerant When air conditioning is turned off, refrigerant foams and then stay clear Proper *:Bubbles in the sight glass with ambient temperatures higher can be considered normal if cooling is sufficient

AC16 AIR CONDITIONING SYSTEM INSTALLATION OF MANIFOLD GAUGE SET HINT: To prevent releasing refrigerant, use charging hoses with a stop valve when installing the manifold gauge set to service valves on the refrigerant line. 1. CONNECT CHARGING HOSES WITH A STOP VALVE TO MANIFOLD GAUGE SET Tighten the nuts by hand. CAUTION: Do not connect the wrong hoses to the high pres sure and the low pressure sides. To prevent loosening the nuts, do not apply compressor oil to seat of the connection. 2. CLOSE HAND VALVES OF BOTH STOP VALVES 3. CLOSE BOTH HAND VALVES OF GAUGE SET 4. REMOVE PLUGS FROM SERVICE VALVES ON REFRIGERANT LINE 5. CONNECT STOP VALVES TO SERVICE VALVES Tighten the nuts by hand. CAUTION: Do not connect the wrong valves to the high pres sure and the low pressure sides. To prevent loosening the nuts, do not apply com pressor oil to seat of the connection. 6. OPEN HAND VALVES OF BOTH STOP VALVES REMOVAL OF MANIFOLD GAUGE SET 1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET 2. CLOSE HAND VALVES OF BOTH STOP VALVES 3. DISCONNECT STOP VALVES FROM SERVICE VALVES ON REFRIGERANT LINE 4. INSTALL PLUGS TO SERVICE VALVES

AIR CONDITIONING SYSTEM AC17 ONVEHICLE INSPECTION 1. CHECK CONDENSER FINS FOR BLOCKAGE OR DAMAGE If the fins are clogged, clean them with pressurized water. NOTICE: Be careful not to damage the fins. 2. MAKE SURE THAT DRIVE BELT IS INSTALLED CORRECTLY After installing the drive belt, check that it fits properly in the ribbed grooves. 3. CHECK DRIVE BELT TENSION Using a belt tension gauge, check the drive belt tension. Belt tension gauge: Nippondenso BTG20 (9550600020) or Borroughs No.BT3373F Drive belt tension: Engine 4AFE 5S FE 3SGTE New belt (lbf) 160 ± 25 165 ± 10 165 ± 10 Used belt (Ibf) 100 ± 20 110 ± 10 84 ± 15 HINT: New belt refers to a belt which has been used less than 5 minutes on a running engine. Used belt refers to a belt which has been used on a running engine for 5 minutes or more. 4. START ENGINE 5. TURN ON A/C SWITCH Check that the A/C operates at each position of the blower switch. 6. CHECK MAGNETIC CLUTCH OPERATION If magnetic clutch does not engage, check the A/C fuse. 7. CHECK THAT IDLE INCREASES When the magnetic clutch engages, engine revolution should increase. Standard idleup rpm: 900 1,000 rpm 8. CHECK CONDENSER FAN MOTOR ROTATES 9. CHECK AMOUNT OF REFRIGERANT If you can see bubbles in the sight glass, additional re frigerant is needed. (See page AC15) 10. IF NO COOLING OR IT IS INSUFFICIENT, INSPECT FOR LEAKAGE Using a gas leak tester, inspect each component of the refrigeration system.

AC18 AIR CONDITIONING SYSTEM INSPECTION OF REFRIGERATION SYSTEM WITH MANIFOLD GAUGE SET This is a method in which the trouble is located by using a manifold gauge set. (See Installation of Manifold Gauge Set on page AC16) Read the manifold gauge pressure when the following conditions are established: (a) Temperature at the air inlet with the switch set at RECIRC is 30 35 C (86 95 F) (b) Engine running at 2,000 rpm (c) Blower fan speed control switch set at high speed (d) Temperature control switch set at max, cool side HINT: It should be noted that the gauge indications may vary slightly due to ambient temperature conditions. NOTICE: Always recover refrigerant before removing the parts in the refrigerant line and evacuating air. Evacuate air and charge proper amount of purified refrigerant after installing the parts in the refrigerant line. Gauge reading kpa (kgf/cm 2, psi) LO: 147 196 (1.5 2.0, 21 28) HI: 1,422 1,471 (14.5 15,0, 206213) Condition Normal cooling Probable cause Normally functioning system During operation, pressure at low pressure side sometimes becomes a vacuum and sometimes normal Periodically cools and then fails to cool Moisture present in refrigeration system (1) Replace receiver (2) Remove moisture in system through repeatedly evacu ating air

AIR CONDITIONING SYSTEM AC19 NOTICE: Always recover refrigerant before removing the parts in the refrigerant line and evacuating air. Evacuate air and charge proper amount of purified refrigerant after installing the parts in the refrigerant line. Gauge reading kpa (kgf/cm 2, psi) Pressure low at both low and high pressure sides Condition Insufficient cooling Bubbles seen in sight glass Probable cause Insufficient refrigerant (1) Check for gas leakage with gas leak tester and repair if necessary (2) Add refrigerant until bubbles disappear Insufficient cooling Frost on tubes from receiver to unit Refrigerant flow obstructed by dirt in receiver Replace receiver AC0069 Pressure too high at both low and high pressure sides Insufficient cooling Insufficient cooling of condenser (1) Clean condenser (2) Check fan motor operation Refrigerant overcharged (1) Check amount of refrigerant If refrigerant is overcharged (2) Recover refrigerant (3) Evacuate air and charge proper amount of purified refrigerant AC0070 Insufficient cooling Frost or Large amount of dew on piping at low pressure side Air present in system Expansion valve improperly mounted, heat sensing tube defective (Opens too wide) (1) Replace receiver (2) Check compressor oil to see if dirty (3) Remove air in system through repeatedly evacu ating air (1) Check heat sensing tube installation condition If (1) is normal (2) Check expansion valve and replace if defective HINT at 6: These gauge indications are for when the refrigeration system has been opened and the refrigerant charged without evacuating air.

AC20 AIR CONDITIONING SYSTEM, Special Tools and Equipment, SSM (Special Service Materials) NOTICE: Always recover refrigerant before removing the parts in the refrigerant line and evacuating air. Evacuate air and charge proper amount of purified refrigerant after installing the parts in the refrigerant, line. Gauge reading kpa (kgf/cm 2, psi) Vacuum indicated at low pressure side, verylow pressure indicated at high pressure Condition Does not cool (Cools from time to time in some cases) Frost or dew seen on piping before and after receiver or expansion valve Probable cause Refrigerant does not circulate (1) Check heat sensing tube for gas leakage and replace expansion valve if defective If (1) is normal (2) Clean out dirt in expansion valve by blowing with air If not able to remove dirt, replace expansion valve (3) Replace receiver Pressure too high at low pressure side, pressure too low at high pressure side Does not cool Insufficient compression Repair or replace compressor SPECIAL TOOLS AND EQUIPMENT Tool Ohmmeter Voltage meter Ammeter Air conditioner service tool set Charging hose kit with stop valve Magnetic clutch remover Magnetic clutch stopper Snap ring pliers (External type) SST No. 0711058011 0711058040 0711266040 0711276060 0711484020 Use To perform electrical diagnosis To perform electrical diagnosis To perform electrical diagnosis To evacuate and charge system If you require a stop valve, please order this kit To remove pressure plate To remove and install pressure plate To remove and install rotor and stator SSM (SPECIAL SERVICE MATERIALS) Part Name Part No. Use etc. ND OIL6, SUNISO No.5GS or equivalent 0711768040 Compressor