HIGH DOSE PHOSPHINE FUMIGATION USING ON-SITE MIXING

Similar documents
MONITORING FUMIGATION EFFECTIVENESS USING BIOASSAYS OF MIXED AGED CULTURES OF TARGET PESTS

Fumigation of stored-grain insects a two locus model of phosphine resistance

Improved Envirosol fumigation methods for disinfesting export cut flowers and foliage crops

UltraPhos: High Purity Phosphine Revisited Ryan, R.F. 1* and Nicolson, J. 1

Carefully to Carry. Fumigation of ships and their cargoes

S. Navarro and E. Donahaye Departmenr of Stored Products, ARO, The Volcani Center, Bet Dagan, Israel

Alternative fumigation and cold disinfestation methods

Grain Bin Fumigation. Legislative Requirements and Guidelines. Crystal Lafrance Ministry of the Environment London Regional Office Feb.

Developing effective fumigation protocols to manage strongly phosphine-resistant Cryptolestes ferrugineus (Stephens) (Coleoptera: Laemophloeidae)

Practical pest control

Principles of (phosphine) fumigation

M.S. Ahmad, T. Mahmood & H. Ahmad"

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Innovation in Fumigation. Blaine Timlick Canadian Grain Commission

Mathematical Modelling of Fumigant Transport in Stored Grain

PS Response of eleven stored product pest species to modified atmospheres with high carbon dioxide concentrations.

Integrated storage pest control methods using vacuum or CO 2 in transportable systems

PROGRESS IN THE USE OF CONTROLLED ATMOSPHERES IN ACTUAL FIELD SITUATIONS IN THE UNITED STATES

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

FLAMMABLE LIQUIDS COMPLIANCE NOTE

No. 6 GRAIN CERTIFICATION

A practical guide to restrictive flow orifices

Guide to Fumigation Under Gas-Proof Sheets

International Maritime Dangerous Goods (IMDG) Special Provision 961 and 962

Notice to Industry 30/2009

Department of Transportation Hazardous Material Regulations General Awareness, Safety & Security Training. For: University of Dayton Hazmat Employees

FUMIGATION MANAGEMENT PLAN TEMPLATE

ISPM No. 15 GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL IN INTERNATIONAL TRADE (2002)

Commodity Fumigation

Design of Closed-loop Fumigation Systems for Grain Storage Structures

Compressed Gas Cylinder Safety

MARSHALL UNIVERSITY HAZARDOUS WASTE DISPOSAL SECTION

Evaluation of headspace Solid Phase Micro-extraction method for analysis of phosphine residues in wheat

Precision Fumigation TM and ProFume gas fumigant

ADMINISTRATIVE SERVICES MANUAL

INDUSTRIAL SITE SERVICES. sharing responsibility

CONTROLLED ATMOSPHERE Application for Milling Industry

Ethyl formate fumigation as a replacement for methyl bromide fumigation in dried vine fruit.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

North American Regulations for packaging materials

Safety Storage Cabinets

Draft - Fumigation Management Plan

Air Eliminators and Combination Air Eliminators Strainers

Carefully to Carry. Agricultural produce insect infestation and fumigation. ) generated from solid phosphide preparations.

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA

Hazardous Waste Management Procedures

Sulfuryl Fluoride ProFume* Gas Fumigant

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

The Performance of Australian Industrial Projects

Product Code: VLB ml cartridges. Substance Name EC No. CAS No. % by Wt Hazard Symbols n Butylacetate

Department of Biology

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

Detia Degesch MARKETING NEWS

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union.

Select the Right Relief Valve - Part 1 Saeid Rahimi

Hazardous Substances and New Organisms Act 1996

PS Spinosad provides long-term protection for stored wheat

PROCEEDINGS OF AN INTERNATIONAL CONFERENCE ON CONTROLLED ATMOSPHERE AND FUMIGATION IN GRAIN STORAGES. Winnipeg, Canada, June 11-13,1992 CAF

T U R B I N E G A S M E T E R

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

Nitrogen Blanketing for Methanol Storage and Transportation

ST. VINCENT AND THE GRENADINES

THE USE OF OZONE IN COOLING TOWERS

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Troubleshooting Your RO

PARALOID KM-1 Acrylic Impact Modifier

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Quebec Quebec Tel : Fax : MSDS: P10 (10% Methane in Argon) PRODUCT INFORMATION

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

Heating Water by Direct Steam Injection

TABLE OF CONTENT

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Supply and Demand Issues Relating to the ACT Taxi Industry

How to prepare a DG Declaration according to IMDG (Amendment 31)

Notes. Material 1. Appropriate Flammable Liquids

RECON WATER HEATER INSTALLATION FORM

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

LIQUEFIED PETROLEUM GASES

A Visual Method for the Detection of Arsenic 0 to 500 µg/l By Dan Kroll R&D Chemist. Hach Co., Loveland Colorado

TRANSPORT OF DANGEROUS GOODS

Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards

SCBA Frequently Asked Questions

How To Design A Gas Dryer

The potential to adversely affect human

Compressed Gas Cylinder Program

Spray Booth Guideline

Statistical estimation using confidence intervals

A guide to solid recovered fuel. Putting waste to good use and producing a sustainable alternative to fossil fuels

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Taiwan s land area is about 36,000 square kilometers. 2/3 of the lands are mountains and slope lands with cultivated land rate only 22%.

Various ways are used to

Sample Written Program. For. Flammable Liquids

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Transcription:

Donahaye, E.J., Navarro, S. and Leesch J.G. [Eds.] (2001) Proc. Int. Conf. Controlled Atmosphere and Fumigation in Stored Products, Fresno, CA. 29 Oct. - 3 Nov. 2000, Executive Printing Services, Clovis, CA, U.S.A. pp. 379-389 HIGH DOSE PHOSPHINE FUMIGATION USING ON-SITE MIXING B. BRIDGEMAN, 1 * R. RYAN, 2 D. GOCK 3 AND P. COLLINS 4 1 Grainco Australia, 619 Ruthven Street, Toowoomba, 4352, QLD, Australia [*e-mail: barry.bridgeman@grainco.com.au] 2 BOC Gases, Sydney, NSW, Australia 3 CYTEC Australia Ltd, Sydney, NSW, Australia 4 Dept of Primary Ind. Qld, 80 Meiers Road, Indooroopilly, QLD 4068, Australia ABSTRACT Methyl bromide (MB) is relied on to maintain insect free grain exports from Queensland Australia. The eminent demise of this fumigant has been the catalyst for the trials conducted at the Globex International Gladstone Port Terminal using high doses of phosphine (PH 3 ) at 1 mg/l, 2 mg/l and 3 mg/l. The trials compared on-site mixing of ECO 2 FUME and Phosphine/air mix to existing conventional technologies. Modifications to the existing MB fumigation system were minimal and although procedures to carry out this work had to be compiled during the trials, the fumigations were successful. The efficacies of the trial fumigations were assessed using bioassays of mixed age cultures of several species of target insects with typical levels of PH 3 resistance. Results indicated that at 25-27ºC, fumigation with PH 3 at 750 ppm for 5 d was successful in controlling all stages of target pests tested. The mobile stages were totally controlled within 3 d, while control of eggs and pupae required a further 1.5 to 2 d. The trials indicated that although the fumigation time could not be reduced to below 5 d, at 25ºC, the cost of fumigant was substantially reduced when compared to MB. The cost of using liquefied forms of PH 3 compared well to all other formulations and the fumigation duration could be reduced by 2 days without compromising efficacy. The other significant advantages of the systems under trial, were that complete dosing and distribution of the fumigant into the bin took 60-80 min and clearance of the fumigant to below detectable levels was reduced to less than 6 h. The systems using liquefied PH 3 do not require disposal of spent residues. Grainco Australia has begun implementation of a high dose PH 3 capability at all Globex Ports and further research and development of PH 3 /air mixing is a priority. INTRODUCTION Globex is a wholly owned subsidiary of Grainco Australia, operating a series of Port facilities on the eastern seaboard of Australia. These strategically located facilities are designed with minimal infrastructure. They are primarily places to unload a

380 commodity from trucks and trains and load it on to ships very quickly. Commodities are usually stored on site for a maximum of one to two weeks. While some consignments are kept for a month or longer there are also significant volumes loaded directly onto ship from rail. This process relies very heavily on MB to comply with the phyto-sanitary requirements of importing countries and the 'Export Control Act'. The 'Export Control Act' prohibits the presence of live insects in commodities being loaded for export. In transit, ship-board fumigations are not permitted in Australia. The MB fumigations at Globex take about 12 h from start to complete post-fumigation gas clearance. This includes time for sealing and cell pressure testing. This flexibility has been designed into the system. Each of these ports has only enough storage capacity to load a couple of average size ships. All storages, which are predominantly concrete vertical bins, are gas tight (pressure decay from 150 mm to 75 mm Hg in 15 min), and all are manifolded to a recirculation system. The handling operation relies on logistics to enable the product to arrive at the port in a timely fashion, and this process has been very successful. A period of fifteen years has now past since a client last detected insects in commodities originating from a discharge port of Grainco Australia. With the impending demise of MB this mode of operation is now under review. There are numerous chemicals being investigated at present in an attempt to put in place alternatives, prior to 2005 (Desmarchelier 1998). Dependence on the development of future research potential requires a solid contingency plan. At present the only other fumigant, ready and registered for disinfestation of grain, is PH 3. Consequently, PH 3 is the logical immediate replacement. The primary concern in using PH 3 fumigation as a MB replacement is the increase in fumigation duration required to attain comparable standards of insect control. The secondary issue is the need for it to be cost effective in achieving the required standard. An issue, which is inherent with use of PH 3 is the dangerous possibility of exceeding the explosive limit. In this context, the fumigation procedures that were subjected to trial here were also examined to evaluate the relative safety inherent in the use of liquid formulations. This series of trials investigated the feasibility of replacing MB with PH 3 at port fumigations. Phosphine is currently registered for the purpose of grain fumigation and is widely accepted for disinfestation purposes. This series of trials examined two application methods requiring the use of Vaporphos; the first using on-site mixing of Ecofume (ECO 2 FUME - 2% PH 3 98% CO 2 ), the second introducing Vaporphos (VAPORPH 3 OS - 100% PH 3 ) directly into the air-stream within the recirculation ducting. The objective of these trials using liquid formulations was to enable reduction of purge time (time required to introduce the gas and reach even concentration throughout the bulk) and clearance times (time to expel the gas from the bulk at the end of fumigation) for PH 3 as well as reduction in exposure time from that displayed on the label (7 d) as being the time required to achieve complete kill of all life stages of the target pests. Within the scope of these trials was an examination of the relative costs involved with the various application methods. The

data generated from this series of trials could be used to support a change in label specifications, should such a change be justified. MATERIALS AND METHODS 381 Available Formulations The most common application method for PH 3 fumigation is by the use of solid formulations such as aluminium phosphide. The major benefit of solid formulations is that they are very cost effective. However, their drawback is that they require a significant time-period for gas to evolve before the required concentration is attained, and effective fumigation begins. The solid formulations also require removal and subsequent disposal of the spent residues after fumigation. The use of liquid formulations has the advantage of being able to deliver the required dosage during the initial gas purge, in much the same way as in a MB fumigation. This involves a potential saving of two days. The liquid formulations also benefit from not requiring removal of residues. Therefore, fumigations using liquid formulations should be easier to apply and safer to clear. It is possible that the fumigant will also be able to be cleared more quickly in fumigations using liquid formulations since recirculation systems are a pre-requisite for this technology. Costs The cost comparison was based on the cost of fumigant alone, whereas the costs of fumigant application, monitoring and clearance were taken to be constant. The cost of fumigant varies significantly between suppliers, location and user. The costs outlined here are indicative of recommended retail prices in Queensland Australia as obtained from the major supplier. Fumigation exposure times The fumigation exposure times on the label were used as an estimate of how long the fumigation duration should be. In the 2 g/m 3 and the 3 g/m 3 dosage trials the estimates were based solely on indications from laboratory trials as the label does not stipulate a time duration for these doses. A data matrix was developed for each concentration to allow estimation of fumigation duration required to obtain population extinction (LD 99.9 ) (Collins et al. 2000). Data Matrix The laboratory data was collected at the Farming Systems Institute by assessing mixed age cultures of target species using flow-through technology (Winks and Hyne 1994). The process is described in another paper presented at this conference (Collins et al. 2001). The collected data was constructed into a matrix, which delineates the time required for a particular Ct product to achieve efficacy to the 99.9% mortality level (Bridgeman et al. 2001). From this matrix an accurate estimate of the necessary duration for each concentration could be calculated. The bioassays using mixed age cultures were selected from field strains of resistant insects from

382 each of the target species. This process has become standard operating procedure in Grainco Australia fumigation practice (Bridgeman and Collins 1994; Bridgeman 1999; Bridgeman et al. 2001). Trial Protocol. Trial 1: The on-site mixing trial was conducted at the Globex, port facility in Gladstone. The process involved mixing pure liquefied PH 3 Vaporphos, with CO 2 as required. The process could be achieved using cylinderised Ecofume ; however the logistics of handling large numbers of heavy cylinders (12 per bin) was a significant operational concern. The CO 2 was delivered from a 12 tonne bulk tank via a vaporiser. The phosphine as Vaporphos was supplied in G size cylinders. The concentrated gases were delivered to the mixer through particularly sized orifice plates, which ensured that the correct mix (2% PH 3 and 98% CO 2 ) was maintained in the flow. The mixer was controlled to immediately shut off flow from both cylinders if either of the flows could not be maintained. The mixer was constructed by Gas Apps, the Vaporphos was supplied by Cytec Australia, and the CO 2 delivery system supplied and installed by BOC Gases. Once mixed, the 2% PH 3 mixture was delivered via 50 mm PVC pipes to the bin recirculation system. Trial 2 and 3: The phosphine and air mix fumigation was conducted at the Globex installation, Fisherman Island. The process involved feeding the 100% PH 3 Vaporphos directly into the MB recirculation system. Trial 2 was conducted at a dosage of 2 mg/l and Trial 3 at 3 mg/l. The fumigant that was introduced through ducting into the closed recirculation system was regulated directly by manual operation of the cylinder valve. The fans on these recirculation systems are designed to deliver a complete air change to the silo in 20 min. The airflow is delivered upward through the grain into the headspace were it is forced into the return ducting and back down to the fan. High-speed fans such as these are generally not suitable for PH 3 fumigation due to the negative pressure generated at the fan tips causing a significant reduction in the minimum flammability limit of PH 3. To negate the effect of this negative pressure, the fumigant was ducted into the positive pressure side of the fan and the concentration of fumigant was kept below 3,000 ppm at all times during the fumigation, with particular care being taken during the initial purge. With careful management, this maximum concentration could be avoided throughout the process, in all areas except in the small section of the ducting immediately after the induction point. This site was monitored by direct observation of the process through a viewing window provided for the purpose. The recirculation system The recirculation systems used at both sites were designed to carry out fumigant distribution and post-fumigation gas clearance quickly. They achieve a minimum standard of a complete air change in 20 min and are tested periodically for seal integrity.

383 The silos The storages in both trials were concrete vertical bins of 10,000 m 3 capacity. All were conical based and sealed to a high degree of gas tightness. All bins exceed the GA minimum standard pressure decay of from 150 mm Hg to 75 mm Hg in 15 min, by a considerable margin. Fumigant 'induction' and distribution To achieve the desired concentration in each trial, the airflow from the fan, and the gas release from the mixing sites were synchronised. The time required to attain even distribution was estimated from the measured flow inside the ducting. The addition of fumigant mixture was maintained until the calculated dose was delivered, and air flow was then continued until an even distribution was obtained; namely, when the top and bottom in-grain PH 3 concentration readings differed by no more than 50 ppm. If further fumigant was required to achieve the desired concentration, recirculation would be continued while the required fumigant was added, until an even distribution was attained. Daily recirculation of the fumigant remaining in the bin was carried out to ensure adequate and even distribution. Field assessment of fumigation efficacy Gas concentrations were monitored during the fumigation process and the accumulated Ct products were recorded. Bioassays using mixed age cultures of the lesser grain borer Rhyzopertha dominica, the rice weevil Sitophilus oryzae and other target insects were carried out to monitor fumigant efficacy (Bridgeman et al. 2001; Collins et al. 2001). Vials of the test insects were removed three days prior to, and on the day after, the 99.9% control time, as predicted by the data matrix. These vials were returned to the Farming Systems Institute for analysis. The measured Ct products and the data from the bioassays were then combined to establish the validity of the laboratory data matrix. RESULTS Bioassays The results from the bioassays closely followed those predicted in the laboratory trials. This data confirmed that, when the grain temperature was about 25ºC, the 99.9% control of all the major insect pests of stored grain could be achieved within 5 d in concentrations of above 1 mg/l. The data also indicated that there was little advantage in increasing concentrations above 1.5 mg/l. The data represented in Figs. 1 and 2 show the LD 99.9 for R.dominica (resistant strain QRD569) (Fig. 1) and LD 99.9 for S. oryzae (resistant strain QSO335) (Fig. 2). The lines indicate the effect of the fumigation at the 1 mg/l concentration over time. The reduction in population was calculated when compared with a control culture. There was little difference in the 2 mg/l and 3 mg/l dose rate trials. Although other species were also tested, these two species are considered the most important for establishing the required dose rate.

384 100.00% 90.00% 80.00% Adults Lable Rate 70.00% Population Survival (%) 60.00% 50.00% 40.00% 30.00% F1 (Immatures) 20.00% 10.00% 0.00% 0 1 2 3 4 5 6 7 8 Days under fumigation at 1mg/L PH3 (720ppm) Fig. 1. Survival against time curves of the resistant strain QRD569 of Rhyzopertha dominica when exposed to phosphine at 720 ppm. Comparison to the data matrix The data extracted from the field tests was then retrofitted to the data matrix along the accumulated Ct product for the duration, to confirm when population extinction occurred. The data displayed indicates the accumulated Ct product achieved over time. The fumigation rates, when plotted over the laboratory data matrix indicate the point at which significant efficacy occurs. This is represented graphically for each of the concentrations used in the trial. The field data concurred with the data matrix constructed from the laboratory trials. Cost Comparison A cost comparison between the various methods was carried out. The costs compared in Fig. 4 represent the cost of fumigant only. The cost of application was taken as being constant, despite observations of significant differences during the trials.

385 100% Adults Lable Rate 90% 80% 70% S.o. Adults F1 (Immatures) Lable Rate 60% 50% S.o. (F1) 40% 30% 20% 10% 0% - 1 2 3 4 5 6 7 8 Days fumigated at 1mg/l (720ppm) Fig. 2. Survival against time curves of the strain QSO335 of Sitophilus oryzae when exposed to phosphine at 720 ppm. The comparison of costs between the fumigations using liquid formulation techniques varied directly with the dosage employed. Comparison with fumigations involving solid formulations of aluminium phosphide revealed that these were the most cost effective, while Siroflo was the most expensive. MB fumigation compared well cost-wise and was far more time efficient than any of the other methods. Comparison of effective fumigation duration The fumigation duration (required exposure time) of each of the methods was compared with data collected from other methods in common use. Both of the methods used in the above trials achieved the desired 60-80 min initial purge and distribution time as well as the 4-6 h target time for fumigant clearance from the grain bulk.

386 300000 250000 3mg/l PH3 200000 150000 2 mg/l PH3 100000 1 mg/l PH3 50000 Estimation of Population Extinction (LD 99.9) 0 0 20 40 60 80 100 120 140 160 180 Time under Fumigation (Hrs) Fig. 3. Ct products for high dose phosphine fumigations at the Globex Gladstone port facilities of Grainco Australia, 2000. The duration of a typical MB fumigation is about 12 h including sealing and clearance times. The use of the large doses of liquid PH 3 fumigant was successful in reducing purging and clearance times. This allowed some scope for a reduction in the total fumigation time required for PH 3. The bioassay indicated that a reduction in exposure time from the 7 days label rate, to 5 days was justifiable under these conditions. DISCUSSION The results indicate that at 25 o C, it will take a minimum of 5 days to achieve 99.9% control of the strains of typical grain-storage pests tested in these trials. The bioassays were conducted using resistant strains from the field (Collins et al. 2000). Fumigations of this duration would not be suitable for most of the current fumigations carried out at Grainco Australia Ports. However it does mark a significant improvement on the 7 10 days required as a label stipulation. A reduction of PH 3 duration to 5 days would allow direct substitution of MB with PH 3 in a significant proportion of port fumigations. This potential substitution could result in an approximate 60-80% reduction in pre-shipment MB fumigation at

387 Globex ports. The remainder of the shipped commodities arrives at port less than 5 days before loading, and some even arrives as the ship is being loaded. However, less than 60% of exported commodities are fumigated at port, even though all (100%) ships are loaded with some MB treated commodity in the cargo. These statistics indicate that it is theoretically possible to fumigate ~ 60% of grain cargoes with PH 3 while the remaining 40% would linger as a pre-shipment use of MB. This scenario is based on the prerequisite that the logistics of grain movements and the scheduling of shipping must be accurately coordinated. This task appears to pose a considerable challenge, though, if achieved, further reductions in MB dependence could be realised. Fig. 4. Comparative costs of different fumigation procedures and formulations at an 8,000 tonne storage silo at the Globex, Grainco port facility. A major concern not often highlighted in the imminent demise of MB is the consideration of its role as a resistance management strategy (Collins and Bridgeman 1991; Bridgeman 1999). At present, the use of MB at port ensures that populations exhibiting PH 3 resistance that are surviving in the commodity (which may have been previously fumigated with PH 3 several times), are extinguished prior to export. The introduction of another PH 3 fumigation at this critical point merely adds another selection for resistance in the surviving population. It has been very clearly demonstrated recently that the tolerance of target insects to PH 3 is increasing significantly and rapidly. A grain protection strategy based on a total dependence on a single chemical fumigant for an indefinite period is fundamentally flawed

388 (Bridgeman 1999, Collins and Bridgeman 1991). While research into alternatives to MB is progressing, it is the search for a substitute to PH 3 that really needs to be at the focus of our attention. 20 18 2 Clearance 16 Fumigation C/T 14 12 10 3 15 Initial Purge 8 6 7 0.08 0.08 0.08 4 2 0 0.125 0.042 0.3 Methyl Bromide 2 Aluminium Phosphide 2 Siroflo 6 0.05 High Dose (1mg/L) Fumigation Method 5 0.045 High Dose (2mg/L) 5 0.042 High Dose (3mg/L) Fig. 5. comparison of exposure duration of different fumigation procedures and formulations at an 8,000 tonne storage silo at the Globex, Grainco port facility. CONCLUSION The data collected in this series of trials clearly indicates that there is scope to reduce the duration of high dose liquid PH 3 fumigation from 7 days to 5 days when the grain temperature is above 25 o C. Fumigation using liquid formulations of PH 3 was shown to be a very effective pest management technique. It is also concluded that high dose PH 3 fumigation can play a significant role in replacing MB applications. Once development is fully complete the process will find application in many other aspects of commodity disinfestation. Further research is required into the technical aspects of mixing PH 3 with air to ensure that all safety aspects of this technique are considered.

ACKNOWLEDGEMENTS 389 The entire project outlined in this paper has been the work of a focused team. Without their combined efforts the considerable work required to do this study could never have been accomplished. We recognise the considerable efforts of the staff of the Farming Services Institute, QDPI, Indooroopilly; the Grain Quality Staff of Globex Gladstone Port; the Grainco Australia Fumigation Staff; BOC Gases and Cytec Australia and thank them all. REFERENCES Bridgeman B.W. (1999) Grainco Australia, Integrated Pest Management Plan. Internal Publication, Grainco Australia Limited, Australia. Bridgeman B.W., and Collins P.J. (1994) IPM in the Grainco, Australia, storage system. In: Proc. 6th Int. Working Conf. on Stored-Product Protection (Edited by Highley, E., Wright, E.J., Banks, H.J. and Champ, B.R.) Canberra, Australia, 17-23 April 1994, CAB International, Wallingford, Oxon, UK, 2, 910-914. Bridgeman B.W., Collins P.J. and Davis D. (2001) Assessment of the effectiveness of fumigation protocols in the field. In: Proc. Australian Postharvest Technical Conference, Adelaide, 1-4 Aug. 2000, (in print). Collins P.J. and Bridgeman B.W. (1991) Bulk Grains Queensland Integrated Pest Management Plan Strategies for the Nineties. Internal Publication Grainco Australia Limited, Australia. Collins P.J., Daglish G.J., Nayak, M.K., Ebert, P.R., Schlipalius, D., Chen, W., Pavic, H., Lambkin, T.M., Kopittke, R. and Bridgeman, B.W. (2001) Combating the evolution of strong resistance to phosphine in Australia. In Int. Conf. on Controlled Atmosphere and Fumigation in Stored Products, Fresno, California. 2000, (this publication). Desmarchelier, J.M. (1998) Potential new fumigants. In: Stored grain in Australia. Proc. Australian Post-harvest Technical Conference. (Edited by Banks, H.J., Wright, E.J., Damcevski, K.A.), 1998. Canberra, Australia, 133-137. Winks R.G. and Hyne E.A. (1994) The use of mixed-age cultures in the measurement of response to phosphine. In: Proc. Int. Conf. on Controlled Atmosphere and Fumigation in Stored Products, (Edited by Donahaye, E.J., Navarro, S. and Varnava, A.), 21-26 April 1996, Printco Ltd., Nicosia, Cyprus, 3-15.