Base Station Antennas
MISSION STATEMENT Design, manufacture and deploy worldwide RF and fiber optic total solutions for telecommunication networks Create value for our customers through innovative products, customized services and cost effective solutions Highest quality standards, state-of-the-art manufacturing facilities and reliable supply chain management to achieve and exceed customer expectations Socially responsible to our community and environment we do business in and committed to employee's personnel development Core Value Value Innovation Customer Focus Sustainable Growth Social Responsibility
Introduction Rosenberger was founded in 1958. It ranks among the leading telecommunication solution providers. To better serve Asian customers, Rosenberger expanded its business in 1997 with the launch of Rosenberger Asia Pacific. From the beginning, Rosenberger Asia Pacific has enjoyed tremendous growth. There are currently 5 factories operating across China with more than 3000 employees and 50,000 M2 of production area, which support 5 product groups: Communication System Solutions IT/Data Communication Testing and Measurement Automotive Medical & Industries A sales network covering the entire Asian-Pacific region generates an annual turnover close to 200 million USD. Reliability and competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading companies in their respective industries. Along with the expansion of product lines, Rosenberger has established new business unit of Rosenberger (Shanghai) Technology Co.,Ltd, which offers unique and innovative wireless communication products and solutions. Through its long experience in a wide range of technologies, vast R&D investments, and emphasis on customer satisfaction and quality, Rosenberger Asia Pacific is poised to keep its leading role and continue its rapid expansion. With an unwavering commitment to the core values of customer focus, value innovation, sustainable growth and social responsibility, Rosenberger meets the expectation of its customers as well as its employees.
PRODUCT PORTFOLIOS Communication System Solutions Base Station Antenna Feeder Systems Wireless Coverage Optimization Solutions Microwave Backhaul Solutions RF in Cabinet Solutions Passive Intermodulation Measurement Systems FTTA/FTTH Optical Fiber Solutions OSP Fiber Optic Outside Plant Solutions In Building Optical Network Connecting Solutions Low Frequency Cables and Components Network Optimization Services IT/Data Communication Premise Network Cabling Products Data Center/Cloud Computing Solutions Intelligent Infrastructure Management System Testing and Measurement Test Cables Precision Connectors Calibrations Accessories and Tools Automotive FAKRA Connectors and Cable Assemblies HSD System Medical & Industries Non-Magnetic RF Connectors Non-Magnetic RF Cable Assemblies Data/RF/Power/DC Hybrid Connectors and Assemblies Custom Data/Power Connectivity System Fiber Optic Connectivity Products
CONTENT Rosenberger S-Wave antenna technology 05 Guide 06 Antenna Index 07 Omni-directional Antennas 12 Low Band Panel Antennas 698-960MHz Dual Polarization +45 / 45 16 Low Band Panel Antennas 806-960MHz Vertical Polarization 29 High Band Panel Antennas 1710-2170MHz Dual Polarization +45 / 45 37 High Band Panel Antennas 1710-2170MHz Vertical Polarization 46 LTE Extra-wide Band Antennas 1710-2690MHz Dual Polarization +45 / 45 50 Dual Band Antennas_2 Ports (with Inner Combiner) Dual Polarization +45 / 45 55 Dual Band Antennas_4 Ports Dual Polarization +45 / 45 65 Triple Band Antennas_6 Ports Dual Polarization +45 / 45 75 Tri-Sector Antennas Dual Polarization +45 / 45 79 REMOTE ELECTRICAL TILT 81 Installation Kits 89 Rosenberger Service 93
Rosenberger S-Wave antenna technology Rosenberger s S-Wave antenna solution covers frequencies bands including 700LTE, AMPS, GSM, DCS, PCS, AWS, UMTS, Wi-Max, and 4G-LTE, etc. They are designed to meet the toughest application and functional operation requirements covering single band, broadband and multi-band models. Every antenna series is based on the experience and solid theoretical knowledge of our strong international R&D team. Through extensive testing, simulation and optimization, the S-Wave antenna guarantees excellent mechanical and electrical performance. Rosenberger is committed to supplying high quality and cost effective antenna solutions. Design Philosophy Rosenberger adopts many state-of-the-art CAD simulation tools including ANSYS HFSS, AutoCAD, SolidWorks and more, to guarantee design efficiency. These mechanical and electrical systems combine, allowing the Rosenberger design team to improve analysis, optimization and integration of antenna radiation/circuits and physical parameters. Your partner for Your Network Optimization
Guide 05 06 Frequency Range Gain, Polarization, Tilt Radome Material S-Wave 09/U/U - 65/65/90-14/14/17DV15/V15/V8 CS - F Horizontal Beamwidth Special Designation Frequency Group Special Designation Meaning Frequency band (MHz) C With build-in combiner 07 698-896 S Tri-sector (3 in 1) antenna 08 806-896 09 870-960 0709 790-960 A Upgraded version (higher performance) B1, B2, B3. Customized version 0809 806-960 18 1710-1880 19 1850-1990 21 1920-2170 U 1710-2170 EW 1710-2690 Electrical tilt Blank = Fixed 0 electrical tilt Tx = Fixed electrical tilt, x=tilt angle Vx = Adjustable electrical tilt, start angle=0 and x=end angle Vs/x = Adjustable electrical tilt, start angle=s and x=end angle Horizontal Beamwidth Symbol Horizontal 3dB Beamwidth ( ) 65 65 Examples Quad antenna: S-Wave 0709/0709/U/U-65-15/15/17/17DV15/V15/V8/V8-F 90 90 OD 360 Polarization Blank = Vertical polarization D = +/-45 polarization Radome material Blank = UPVC F = Fiberglass
Antenna Index Omni-Directional Antennas Vertical Polarization Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 09-OD-11-F 870-960 360 11dBi 0 13 S-Wave 18-OD-11-F 1710-1880 360 11dBi 0 14 S-Wave 21-OD-11-F 1920-2170 360 11dBi 0 15 Low Band Panel Antennas 698-960MHz Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 0809-30-18.5D 806-960 30 18.5dBi 0 17 S-Wave 0809-30-18.5DT3 806-960 30 18.5dBi 3 17 S-Wave 0809-30-18.5DT6 806-960 30 18.5dBi 6 17 S-Wave 0809-30-21D 806-960 30 21dBi 0 18 S-Wave 0809-30-21DT3 806-960 30 21dBi 3 18 S-Wave 0809-30-21DT6 806-960 30 21dBi 6 18 S-Wave 07-65-14.5D 698-896 65 14.5dBi 0 19 S-Wave 07-65-14.5DT3 698-896 65 14.5dBi 3 19 S-Wave 07-65-14.5DT6 698-896 65 14.5dBi 6 19 S-Wave 0809-65-15D 806-960 65 15dBi 0 20 S-Wave 0809-65-15DT3 806-960 65 15dBi 3 20 S-Wave 0809-65-15DT6 806-960 65 15dBi 6 20 S-Wave 0809-65-16.5D 806-960 65 16.5dBi 0 21 S-Wave 0809-65-16.5DT3 806-960 65 16.5dBi 3 21 S-Wave 0809-65-16.5DT6 806-960 65 16.5dBi 6 21 S-Wave 0809-65-18D 806-960 65 18dBi 0 22 S-Wave 0809-65-18DT3 806-960 65 18dBi 3 22 S-Wave 0809-65-18DT6 806-960 65 18dBi 6 22 S-Wave 0809-65-15DV15 806-960 65 15dBi 0-15 23 S-Wave 0809-65-16.5DV10 806-960 65 16.5dBi 0-10 24 S-Wave 0809-65-18DV8 806-960 65 18dBi 0-8 25 S-Wave 0809-90-15.5D 806-960 90 15.5dBi 0 26 S-Wave 0809-90-15.5DT3 806-960 90 15.5dBi 3 26 S-Wave 0809-90-15.5DT6 806-960 90 15.5dBi 6 26 S-Wave 0809-90-17D 806-960 90 17dBi 0 27 S-Wave 0809-90-17DT3 806-960 90 17dBi 3 27 S-Wave 0809-90-17DT6 806-960 90 17dBi 6 27 S-Wave 0809-90-17DV10 806-960 90 17dBi 0-10 28
Low Band Panel Antennas 806-960MHz Vertical Polarization 07 08 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 0809-30-20 806-960 30 20dBi 0 30 S-Wave 0809-30-20T3 806-960 30 20dBi 3 30 S-Wave 0809-30-20T6 806-960 30 20dBi 6 30 S-Wave 08-65-15 806-896 65 15dBi 0 31 S-Wave 08-65-15T3 806-896 65 15dBi 3 31 S-Wave 08-65-15T6 806-896 65 15dBi 6 31 S-Wave 08-65-17 806-896 65 17dBi 0 32 S-Wave 08-65-17T3 806-896 65 17dBi 3 32 S-Wave 08-65-17T6 806-896 65 17dBi 6 32 S-Wave 08-65-18 806-896 65 18dBi 0 33 S-Wave 08-65-18T3 806-896 65 18dBi 3 33 S-Wave 08-65-18T6 806-896 65 18dBi 6 33 S-Wave 09-65-15 870-960 65 15dBi 0 34 S-Wave 09-65-15T3 870-960 65 15dBi 3 34 S-Wave 09-65-15T6 870-960 65 15dBi 6 34 S-Wave 09-65-17 870-960 65 17dBi 0 35 S-Wave 09-65-17T3 870-960 65 17dBi 3 35 S-Wave 09-65-17T6 870-960 65 17dBi 6 35 S-Wave 09-65-18 870-960 65 18dBi 0 36 S-Wave 09-65-18T3 870-960 65 18dBi 3 36 S-Wave 09-65-18T6 870-960 65 18dBi 6 36 High Band Panel Antennas 1710-2170MHz Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave U-33-21D 1710-2170 33 21dBi 0 38 S-Wave U-33-21DT3 1710-2170 33 21dBi 3 38 S-Wave U-33-21DT6 1710-2170 33 21dBi 6 38 S-Wave U-65-15.5D 1710-2170 65 15.5dBi 0 39 S-Wave U-65-15.5DT3 1710-2170 65 15.5dBi 3 39 S-Wave U-65-15.5DT6 1710-2170 65 15.5dBi 6 39 S-Wave U-65-18D 1710-2170 65 18dBi 0 40 S-Wave U-65-18DT3 1710-2170 65 18dBi 3 40 S-Wave U-65-18DT6 1710-2170 65 18dBi 6 40 S-Wave U-65-19D 1710-2170 65 19dBi 0 41 S-Wave U-65-19DT3 1710-2170 65 19dBi 3 41 S-Wave U-65-19DT6 1710-2170 65 19dBi 6 41 S-Wave U-65-15DV15 1710-2170 65 15dBi 0-15 42 S-Wave U-65-18DV10 1710-2170 65 18dBi 0-10 43 S-Wave U-90-17D 1710-2170 90 17dBi 0 44 S-Wave U-90-17DT3 1710-2170 90 17dBi 3 44 S-Wave U-90-17DT6 1710-2170 90 17dBi 6 44 S-Wave U-90-17DV10 1710-2170 90 17dBi 0-10 45
High Band Antennas 1710-2170MHz Vertical Polarization Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 18-65-18 1710-1880 65 18dBi 0 47 S-Wave 18-65-18T3 1710-1880 65 18dBi 3 47 S-Wave 18-65-18T6 1710-1880 65 18dBi 6 47 S-Wave 21-65-18 1920-2170 65 18dBi 0 48 S-Wave 21-65-18T3 1920-2170 65 18dBi 3 48 S-Wave 21-65-18T6 1920-2170 65 18dBi 6 48 S-Wave U-65-18 1710-2170 65 18dBi 0 49 S-Wave U-65-18T3 1710-2170 65 18dBi 3 49 S-Wave U-65-18T6 1710-2170 65 18dBi 6 49 LTE Extra-wide Band Antennas 1710-2690MHz Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave EW-65-15DV15 1710-2690 65 15dBi 0-15 51 S-Wave EW-65-18DV10 1710-2690 65 18dBi 0-10 52 S-Wave EW/EW-65-15DV15 1710-2690 65 15dBi 0-15 1710-2690 65 15dBi 0-15 53 S-Wave EW/EW-65-18DV10 1710-2690 65 18dBi 0-10 1710-2690 65 18dBi 0-10 54 Dual Band Antennas _2 ports (with Inner Combiner) Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 0709/U-65-15/17DC-F S-Wave 0709/U-65-15/17DT6C-F S-Wave 0709/U-65-15/17DV15/10C-F S-Wave 0709/U-65-16/18DC-F S-Wave 0709/U-65-16/18DT6C-F S-Wave 0709/U-65-16/18DV10/8C-F S-Wave 0709/U-65-17/18DC-F S-Wave 0709/U-65-17/18DT6C-F S-Wave 0709/U-65-17/18DV8C-F 790-960 65 15dBi 0 1710-2170 65 17dBi 0 56 790-960 65 15dBi 6 1710-2170 65 17dBi 6 57 790-960 65 15dBi 0-15 1710-2170 65 17dBi 0-10 58 790-960 65 16dBi 0 1710-2170 65 18dBi 0 59 790-960 65 16dBi 6 1710-2170 65 18dBi 6 60 790-960 65 16dBi 0-10 1710-2170 65 18dBi 0-8 61 790-960 65 17dBi 0 1710-2170 65 18dBi 0 62 790-960 65 17dBi 6 1710-2170 65 18dBi 6 63 790-960 65 17dBi 0-8 1710-2170 65 18dBi 0-8 64
Dual Band Antennas _4 ports Dual Polarization +45 / 45 09 10 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page S-Wave 0709/U-65-15/17D-F 790-960 65 15dBi 0 1710-2170 65 17dBi 0 66 S-Wave 0709/U-65-15/17DT6-F 790-960 65 15dBi 6 1710-2170 65 17dBi 6 67 S-Wave 0709/U-65-15/17DV15/10-F 790-960 65 15dBi 0-15 1710-2170 65 17dBi 0-10 68 S-Wave 0709/U-65-16/18D-F 790-960 65 16dBi 0 1710-2170 65 18dBi 0 69 S-Wave 0709/U-65-16/18DT6-F 790-960 65 16dBi 6 1710-2170 65 18dBi 6 70 S-Wave 0709/U-65-16/18DV10/V8-F 790-960 65 16dBi 0-10 1710-2170 65 18dBi 0-8 71 S-Wave 0709/U-65-17/18D-F 790-960 65 17dBi 0 1710-2170 65 18dBi 0 72 S-Wave 0709/U-65-17/18DT6-F 790-960 65 17dBi 6 1710-2170 65 18dBi 6 73 S-Wave 0709/U-65-17/18DV8-F 790-960 65 17dBi 0-8 1710-2170 65 18dBi 0-8 74 Triple Band Antennas _6 ports Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page 790-960 65 15dBi 0-15 S-Wave 0709/U/U-65-15DV15-F 1710-2170 65 15dBi 0-15 76 1710-2170 65 15dBi 0-15 790-960 65 16dBi 0-8 S-Wave 0709/U/U-65-16DV8/V12/V12-F 1710-2170 65 16dBi 0-12 77 1710-2170 65 16dBi 0-12 790-960 65 17dBi 0-8 S-Wave 0709/U/U-65-17DV8/V10/V10-F 1710-2170 65 17dBi 0-10 78 1710-2170 65 17dBi 0-10
Tri-Sector Antennas Dual Polarization +45 / 45 Type Frequency (MHz) Horizontal Beamwidth Gain Tilt Page 1710-2170 65 18dBi 0-8 S-Wave U-65-18DV10S 1710-2170 65 18dBi 0-8 1710-2170 65 18dBi 0-8 80 Remote Electrical Tilt 81 Installation Kits 89
OMNI-DIRECTIONAL ANTENNAS VERTICAL Polarization 11 12 Your partner for Your Network Optimization
Omni-Directional 870-960MHz 11dBi S-Wave 09-OD-11-F Frequency Range 870-960MHz Polarization Vertical Gain 11dBi Horizontal 3dB Beam Width 360 Vertical 3dB Beam Width 7.5º Electrical Down Tilt 0º, Fixed Impedance 50Ω VSWR < 1.5 Max, Power Per Input 500W Connector Type 1 X 7-16 DIN(F) 7.5kg Max. Wind Velocity 200Km/h Ø65 X 3560mm Radome Material Fiberglass 870~960 7-16 DIN
Omni-Directional 1710-1880MHz 11dBi 13 14 S-Wave 18-OD-11-F Frequency Range 1710-1880MHz Polarization Vertical Gain 11dBi Horizontal 3dB Beam Width 360 Vertical 3dB Beam Width 7º Electrical Down Tilt 0º, Fixed Impedance 50Ω VSWR < 1.5 Max, Power Per Input 500W Connector Type 1 X 7-16 DIN(F) 6.5kg Max. Wind Velocity 200Km/h Ø65 X 1800mm Radome Material Fiberglass 1710-1880 7-16 DIN
Omni-Directional 1920-2170MHz 11dBi S-Wave 21-OD-11-F Frequency Range 1920-2170MHz Polarization Vertical Gain 11dBi Horizontal 3dB Beam Width 360 Vertical 3dB Beam Width 6.5º Electrical Down Tilt 0º, Fixed Impedance 50Ω VSWR < 1.5 Max, Power Per Input 500W Connector Type 1 X 7-16 DIN(F) 5.5kg Max. Wind Velocity 200Km/h Ø65 X 1500mm 1920-2170 7-16 DIN
Low Band Panel Antennas 698-960MHz Dual Polarization +45 / 45 15 16 Your partner for Your Network Optimization
Xpol Panel 806-960 30º 18.5dBi FET0º, 3º, 6º S-Wave 0809-30-18.5D S-Wave 0809-30-18.5DT3 S-Wave 0809-30-18.5DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 18dBi 18.5dBi Horizontal 3dB Beam Width 31º 29º Vertical 3dB Beam Width 15º 14º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB Front to Back Ratio, 180º±30º > 30dB > 30dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 22kg Max. Wind Velocity 200Km/h 1296 X 565 X 100mm
Xpol Panel 806-960 30º 21dBi FET0º, 3º, 6º 17 18 S-Wave 0809-30-21D S-Wave 0809-30-21DT3 S-Wave 0809-30-21DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 20dBi 20.5dBi Horizontal 3dB Beam Width 31º 29º Vertical 3dB Beam Width 8.5º 7.5º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15 db > 15dB Front to Back Ratio, 180º±30º > 30dB > 30dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±30º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 40kg Max. Wind Velocity 200Km/h 2416 X 565 X 100mm
Xpol Panel 698-896 65º 14.5dBi dbi FET0º, 3º, 6º S-Wave 07-65-14.5D S-Wave 07-65-14.5DT3 S-Wave 07-65-14.5DT6 Frequency Range 698-896MHz Polarization ±45º Gain 14.3dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 16º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 12dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±30º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 698-896MHz 698-896 698-896 7-16 DIN 7-16 DIN Connector Type 2 X 7-16 DIN(F) 15kg Max. Wind Velocity 200Km/h 1300 X 300 X 180mm
Xpol Panel 806-960 65º 15dBi FET0º, 3º, 6º 19 20 S-Wave 0809-65-15D S-Wave 0809-65-15DT3 S-Wave 0809-65-15DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 15dBi 15dBi Horizontal 3dB Beam Width 65º 65º Vertical 3dB Beam Width 15º 15º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed Front to Back Ratio, 180º±30º > 30dB > 30dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance > 15dB 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W > 15dB 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 11kg Max. Wind Velocity 200Km/h 1310 X 295 X 115mm
Xpol Panel 806-960 65º 16.5dBi FET0º, 3º, 6º S-Wave 0809-65-16.5D S-Wave 0809-65-16.5DT3 S-Wave 0809-65-16.5DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 16.5dBi 16.5dBi Horizontal 3dB Beam Width 65º 65º Vertical 3dB Beam Width 10º 9º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB > 16dB Front to Back Ratio, 180º±30º > 25dB > 25dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 18kg Max. Wind Velocity 200Km/h 1996 X 282 X 100mm
Xpol Panel 806-960 65º 18dBi FET0º, 3º, 6º 21 22 S-Wave 0809-65-18D S-Wave 0809-65-18DT3 S-Wave 0809-65-18DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 17.5dBi 17.5 dbi Horizontal 3dB Beam Width 65º 65º Vertical 3dB Beam Width 7º 7º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB > 16dB Front to Back Ratio, 180º±30º > 30dB > 30dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance > 15dB 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W > 15dB 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 17kg Max. Wind Velocity 200Km/h 2640 X 295 X 115mm
Xpol Panel 806-960 65º 15dBi VET 0º-15º Adjust. Electrical Downtilt set by hand or by optional Antenna Control Unit (ACU) S-Wave 0809-65-15DV15 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 15dBi 15dBi Horizontal 3dB Beam Width 65º 65º Vertical 3dB Beam Width 15º 15º Electrical Down Tilt 0º-15º 0º-15º Front to Back Ratio, 180º±30º > 25dB > 25dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance > 15dB 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W > 15dB 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 8kg Max. Wind Velocity 200Km/h 1445 X 289 X 134mm
Xpol Panel 806-960 65º 16.5dBi VET 0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU 23 24 S-Wave 0809-65-16.5DV10 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 16.5dBi 16.5dBi Horizontal 3dB Beam Width 68º 65º Vertical 3dB Beam Width 10º 9.5º Electrical Down Tilt 0º-10º 0º-10º Front to Back Ratio, 180º±30º > 25dB > 25dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 400W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 18kg Max. Wind Velocity 200Km/h 1996 X 282 X 100mm
Xpol Panel 806-960 65º 18dBi VET 0º-8º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave 0809-65-18DV8 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 17.5dBi 17.8dBi Horizontal 3dB Beam Width 68º 65º Vertical 3dB Beam Width 7.5º 7.3º Electrical Down Tilt 0º-8º 0º-8º Front to Back Ratio, 180º±30º > 25dB > 25dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 23kg Max. Wind Velocity 200Km/h 2640 X 282 X 100mm
Xpol Panel 806-960 90º 15.5dBi FET0º, 3º, 6º 25 26 S-Wave 0809-90-15.5D S-Wave 0809-90-15.5DT3 S-Wave 0809-90-15.5DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 15.3dBi 15.5dBi Horizontal 3dB Beam Width 90º 88º Vertical 3dB Beam Width 10.5º 10º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB Front to Back Ratio, 180º±30º > 23dB > 23dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 14kg Max. Wind Velocity 200Km/h 1936 X 282 X 100mm
Xpol Panel 806-960 90º 17dBi FET0º, 3º, 6º S-Wave 0809-90-17D S-Wave 0809-90-17DT3 S-Wave 0809-90-17DT6 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 16.5dBi 17dBi Horizontal 3dB Beam Width 90º 85º Vertical 3dB Beam Width 7.5º 7º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB > 16dB Front to Back Ratio, 180º±30º > 25dB > 25dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance > 15dB 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W > 15dB 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 22kg Max. Wind Velocity 200Km/h 2650 X 295 X 145mm
Xpol Panel 806-960 90º 17dBi VET 0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU 27 28 S-Wave 0809-90-17DV10 Frequency Range 806-896MHz 870-960MHz Polarization ±45º ±45º Gain 16dBi 16.2dBi Horizontal 3dB Beam Width 90º 88º Vertical 3dB Beam Width 8º 7.5º Electrical Down Tilt 0º-10º 0º-10º Front to Back Ratio, 180º±30º > 23dB > 23dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 400W 806-896MHz 806~960 806~960 7-16 DIN 7-16 DIN 870-960MHz Connector Type 2 X 7-16 DIN(F) 18kg Max. Wind Velocity 200Km/h 2580 X 282 X 100mm
Low Band Panel Antenna 806-960MHz Vertical Polarization Your partner for Your Network Optimization
Vpol Panel 806-960 30º 20dBi FET0º, 3º, 6º 29 30 S-Wave 0809-30-20 S-Wave 0809-30-20T3 S-Wave 0809-30-20T6 Frequency Range 806-896MHz 870-960MHz Polarization Vertical Vertical Gain 19.7dBi 20.0dBi Horizontal 3dB Beam Width 31º 29º Vertical 3dB Beam Width 9.0º 8.5º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB > 16dB Front to Back Ratio, 180º±30º > 28dB > 28dB Isolation > 30dB > 30dB Cross-polar Ratio, 0º ±30º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~960 7-16 DIN 870-960MHz Connector Type 1 X 7-16 DIN(F) 40kg Max. Wind Velocity 200Km/h 2300 X 565 X 100mm
Vpol Panel 806-896 65º 15.0dBi FET0º, 3º, 6º S-Wave 08-65-15 S-Wave 08-65-15T3 S-Wave 08-65-15T6 Frequency Range 806-896MHz Polarization Vertical Gain 15dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 15º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~896 7-16 DIN Connector Type 1 X 7-16 DIN(F) 12kg Max. Wind Velocity 200Km/h 1300 X 282 X 100mm
Vpol Panel 806-896 65º 17.0dBi FET0º, 3º, 6º 31 32 S-Wave 08-65-17 S-Wave 08-65-17T3 S-Wave 08-65-17T6 Frequency Range 806-896MHz Polarization Vertical Gain 16.5dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 10º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30 db Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~896 7-16 DIN Connector Type 1 X 7-16 DIN(F) 18kg Max. Wind Velocity 200Km/h 1950 X 282 X 100mm
Vpol Panel 806-896 65º 18.0dBi FET0º, 3º, 6º S-Wave 08-65-18 S-Wave 08-65-18T3 S-Wave 08-65-18T6 Frequency Range 806-896MHz Polarization Vertical Gain 17.8dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 7.5º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 806-896MHz 806~896 7-16 DIN Connector Type 1 X 7-16 DIN(F) 22kg Max. Wind Velocity 200Km/h 2640 X 282 X 100mm
Vpol Panel 870-960 65º 15.0dBi FET0º, 3º, 6º 33 34 S-Wave 09-65-15 S-Wave 09-65-15T3 S-Wave 09-65-15T6 Frequency Range 870-960MHz Polarization Vertical Gain 15dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 14º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 870-960MHz 870~960 7-16 DIN Connector Type 1 X 7-16 DIN(F) 12kg Max. Wind Velocity 200Km/h 1300 X 282 X 100mm
Vpol Panel 870-960 65º 17.0dBi FET0º, 3º, 6º S-Wave 09-65-17 S-Wave 09-65-17T3 S-Wave 09-65-17T6 Frequency Range 870-960MHz Polarization Vertical Gain 17dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 9.0º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 870-960MHz 870~960 7-16 DIN Connector Type 1 X 7-16 DIN(F) 18kg Max. Wind Velocity 200Km/h 1950 X 282 X 100mm
Vpol Panel 870-960 65º 18.0dBi FET0º, 3º, 6º 35 36 S-Wave 09-65-18 S-Wave 09-65-18T3 S-Wave 09-65-18T6 Frequency Range 870-960MHz Polarization Vertical Gain 18.0dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 7.0º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 500W 870-960MHz 870~960 7-16 DIN Connector Type 1 X 7-16 DIN(F) 22kg Max. Wind Velocity 200Km/h 2640 X 282 X 100mm
High Band Panel Antenna 1710-2170MHz Dual Polarization +45 / 45 Your partner for Your Network Optimization
Xpol Panel 1710-2170 33º 21dBi FET0º, 3º, 6º 37 38 S-Wave U-33-21D S-Wave U-33-21DT3 S-Wave U-33-21DT6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 20dBi 20.3dBi 20.5dBi Horizontal 3dB Beam Width 36º 35º 33º Vertical 3dB Beam Width 7.3º 7º 6.5º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB > 16dB > 16dB Front to Back Ratio, 180º±30º > 30dB > 30dB > 30dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±30º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1304 X 320 X 72mm
Xpol Panel 1710-2170 65º 15.5dBi FET0º, 3º, 6º S-Wave U-65-15.5D S-Wave U-65-15.5DT3 S-Wave U-65-15.5DT6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 15.2dBi 15.5dBi 15.7dBi Horizontal 3dB Beam Width 66º 66º 64º Vertical 3dB Beam Width 13º 12º 11º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 5kg Max. Wind Velocity 200Km/h 735 X 160 X 72mm
Xpol Panel 1710-2170 65º 18dBi FET0º, 3º, 6º 39 40 S-Wave U-65-18D S-Wave U-65-18DT3 S-Wave U-65-18DT6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 17.5dBi 17.5dBi 17.5dBi Horizontal 3dB Beam Width 65º 65º 65º Vertical 3dB Beam Width 7º 7º 7º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance > 15dB > 15dB 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W > 15dB 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 5.5kg Max. Wind Velocity 200Km/h 1337 X 162 X 95mm
Xpol Panel 1710-2170 65º 19dBi FET0º, 3º, 6º S-Wave U-65-19D S-Wave U-65-19DT3 S-Wave U-65-19DT6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 18.7dBi 19dBi 19.2dBi Horizontal 3dB Beam Width 68º 65º 63º Vertical 3dB Beam Width 4.5º 4.3º 4.1º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 13kg Max. Wind Velocity 200Km/h 1942 X 160 X 72mm
Xpol Panel 1710-2170 65º 15dBi VET 0º-15º Adjust. Electrical Downtilt set by hand or by optional ACU 41 42 S-Wave U-65-15DV15 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 14.5dBi 14.8dBi 15dBi Horizontal 3dB Beam Width 68º 66º 64º Vertical 3dB Beam Width 14º 13.5º 13º Electrical Down Tilt 0º-15º 0º-15º 0º-15º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 6kg Max. Wind Velocity 200Km/h 662 X 160 X 72mm
Xpol Panel 1710-2170 65º 18dBi VET 0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave U-65-18DV10 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 17.4dBi 17.7dBi 17.9dBi Horizontal 3dB Beam Width 68º 66º 64º Vertical 3dB Beam Width 6.7º 6.5º 6.1º Electrical Down Tilt 0º-10º 0º-10º 0º-10º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 8kg Max. Wind Velocity 200Km/h 1302 X 160 X 72mm
Xpol Panel 1710-2170 90º 17dBi FET0º, 3º, 6º 43 44 S-Wave U-90-17D S-Wave U-90-17DT3 S-Wave U-90-17DT6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 16.5dBi 16.7dBi 16.9dBi Horizontal 3dB Beam Width 88º 87º 85º Vertical 3dB Beam Width 6.8º 6.5º 6.2º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 23dB > 23dB > 23dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 13kg Max. Wind Velocity 200Km/h 1302 X 160 X 72mm
Xpol Panel 1710-2170 90º 17dBi VET 0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave U-90-17DV10 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º Gain 16.5dBi 16.7dBi 16.8dBi Horizontal 3dB Beam Width 90º 88º 88º Vertical 3dB Beam Width 7º 6.5º 6.3º Electrical Down Tilt 0º-10º 0º-10º 0º-10º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 23dB > 23dB > 23dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 2 X 7-16 DIN(F) 7.5kg Max. Wind Velocity 200Km/h 1574 X 160 X 72mm
High Band Panel Antenna 1710-2170MHz Vertical Polarization 45 46 Your partner for Your Network Optimization
Vpol Panel 1710-1880 65º 18.0dBi FET0º, 3º, 6º S-Wave 18-65-18 S-Wave 18-65-18T3 S-Wave 18-65-18T6 Frequency Range 1710-1880MHz Polarization Vertical Gain 17.8dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 7.0º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1710-1880MHz 1710-1880 7-16 DIN Connector Type 1 X 7-16 DIN(F) 13kg Max. Wind Velocity 200Km/h 1310 X 160 X 72mm
Vpol Panel 1920-2170 65º 18.0dBi FET0º, 3º, 6º 47 48 S-Wave 21-65-18 S-Wave 21-65-18T3 S-Wave 21-65-18T6 Frequency Range 1920-2170MHz Polarization Vertical Gain 18.0dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 6.0º Electrical Down Tilt 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 16dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.4 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1920-2170MHz 1920-2170 7-16 DIN Connector Type 1 X 7-16 DIN(F) 13kg Max. Wind Velocity 200Km/h 1310 X 160 X 72mm
Vpol Panel 1710-2170 65º 18dBi FET0º, 3º, 6º S-Wave U-65-18 S-Wave U-65-18T3 S-Wave U-65-18T6 Frequency Range 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization Vertical Vertical Vertical Gain 17.5dBi 17.7dBi 18dBi Horizontal 3dB Beam Width 68º 65º 63º Vertical 3dB Beam Width 7º 6.6º 6.3º Electrical Down Tilt 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed 0º, 3º, 6º, Fixed First Upper Sidelobe Suppression > 15dB > 15dB > 15dB Front to Back Ratio, 180º±30º > 25dB > 25dB > 25dB Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 250W 1710-1880MHz 1850-1990MHz 1920-2170MHz 7-16 DIN Connector Type 1 X 7-16 DIN(F) 13kg Max. Wind Velocity 200Km/h 1302 X 160 X 72mm
LTE Extra-wide Band Antennas 1710-2690MHz Dual Polarization +45 / 45 49 50 Your partner for Your Network Optimization
Xpol Panel 1710-2690MHz 65º 15dBi VET0º-15º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave EW-65-15DV15 Frequency Range 1710-2690MHz Polarization ±45º Gain 15dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 14º Electrical Down Tilt 0º-15º First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º > 15dB Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1710-2690MHz 1710-2690 1710-2690 7-16 DIN 7-16 DIN Connector Type 2 X 7-16 DIN(F) 5kg Max. Wind Velocity 200Km/h 730 X 162 X 95mm
Xpol Panel 1710-2690MHz 65º 18dBi VET0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU 51 52 S-Wave EW-65-18DV10 Frequency Range 1710-2690MHz Polarization ±45º Gain 18dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 7º Electrical Down Tilt 0º-10º First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º > 15dB Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1710-2690MHz 1710-2690 1710-2690 7-16 DIN 7-16 DIN Connector Type 2 X 7-16 DIN(F) 7kg Max. Wind Velocity 200Km/h 1250 X 162 X 95mm
Dual Band Panel 1710-2690MHz 65º 15dBi VET0º-15º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave EW/EW-65-15DV15 Frequency Range 1710-2690MHz Polarization ±45º Gain 2X15dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 14º Electrical Down Tilt 0º-15º First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º > 15dB Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1710-2690MHz 1710-2690 1710-2690 1710-2690 1710-2690 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN Connector Type 4 X 7-16 DIN(F) 10kg Max. Wind Velocity 200Km/h 730 X 295 X 115mm
Dual Band Panel 1710-2690MHz 65º 18dBi VET0º-10º Adjust. Electrical Downtilt set by hand or by optional ACU 53 54 S-Wave EW/EW-65-18DV10 Frequency Range 1710-2690MHz Polarization ±45º Gain 2X18dBi Horizontal 3dB Beam Width 65º Vertical 3dB Beam Width 7º Electrical Down Tilt 0º-10º First Upper Sidelobe Suppression > 15dB Front to Back Ratio, 180º±30º > 25dB Isolation > 30dB Cross-polar Ratio, 0º > 15dB Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power Per Input 300W 1710-2690MHz 1710-2690 1710-2690 1710-2690 1710-2690 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN Connector Type 4 X 7-16 DIN(F) 14kg Max. Wind Velocity 200Km/h 1250 X 295 X 115mm
Dual Band Antennas 2 PORTS (with Inner Combiner) Dual Polarization +45 / 45 Your partner for Your Network Optimization
XXpol Panel C 790-960/1710-2170 65º 15/17dBi FET0º/0º 55 56 S-Wave 0709/U-65-15/17DC-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.3dBi 14.9dBi 16.3 dbi 16.6dBi 17.0dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 15/17dBi FET6º S-Wave 0709/U-65-15/17DT6C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.3dBi 14.9dBi 16.3 dbi 16.6dBi 16.8dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 62º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB > 15dB > 15dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 15/17dBi VET0-15º/0-10º Adjust. Electrical Downtilt set by hand or by optional ACU 57 58 S-Wave 0709/U-65-15/17DV15/10C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.3dBi 14.9dBi 16.3 dbi 16.6dBi 17.0dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 0-15º 0-15º 0-10º 0-10º 0-10º First Upper Sidelobe Suppression 0º... 8º... 15º 16...15...14dB 0º... 8º... 15º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 16/18dBi FET0º/0º S-Wave 0709/U-65-16/18DC-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.3dBi 16.0dBi 16.8 dbi 17.4dBi 18.0dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.2º 5º 4.5º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 16/18dBi FET6º/6º 59 60 S-Wave 0709/U-65-16/18DT6C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.3dBi 16.0dBi 16.8 dbi 17.4dBi 18.0dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.2º 5º 4.5º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB > 15dB > 15dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 16/18dBi VET0-10º/0-8º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave 0709/U-65-16/18DV10/V8C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.4dBi 16.0dBi 16.8 dbi 17.4dBi 18.0dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.1º 4.8º 4.3º Electrical Down Tilt 0-10º 0-10º 0-8º 0-8º 0-8º First Upper Sidelobe Suppression 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 17/18dBi FET0º/0º 61 62 S-Wave 0709/U-65-17/18DC-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.5dBi 17.1dBi 17.0 dbi 17.2dBi 18.0dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 17/18dBi FET6º/6º S-Wave 0709/U-65-17/18DT6C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.5dBi 17.1dBi 17.0dBi 17.2dBi 18.0dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 14dB > 14dB > 14dB > 14dB > 14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
XXpol Panel C 790-960/1710-2170 65º 17/18dBi VET0º-8º Adjust. Electrical Downtilt set by hand or by optional ACU 63 64 S-Wave 0709/U-65-17/18DV8C-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.5dBi 17.1dBi 17.0 dbi 17.2dBi 18.0dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 0-8º 0-8º 0-8º 0-8º 0-8º First Upper Sidelobe Suppression 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W Max, Power Per Input 450W 450W Inner Combiner The insertion loss is included in the given antenna values. 790-960MHz 790~960 790~960 C C 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 2 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
Dual Band Antennas 4 Ports Dual Polarization +45 / 45 Your partner for Your Network Optimization
XXpol Panel 790-960/1710-2170 65º 15/17dBi FET0º/0º 65 66 S-Wave 0709/U-65-15/17D-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.5dBi 15.1dBi 16.5dBi 16.8dBi 17.1dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 15/17dBi FET6º S-Wave 0709/U-65-15/17DT6-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.5dBi 15.1dBi 16.5dBi 16.8dBi 17.1dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 62º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB > 15dB > 15dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 15/17dBi VET0-15º/0-10º Adjust. Electrical Downtilt set by hand or by optional ACU 67 68 S-Wave 0709/U-65-15/17DV15/10-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 14.5dBi 15.1dBi 16.5dBi 16.8dBi 17.1dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 14.7º 13.9º 6.7º 6.5º 5.9º Electrical Down Tilt 0-15º 0-15º 0-10º 0-10º 0-10º First Upper Sidelobe Suppression 0º... 8º... 15º 16...15...14dB 0º... 8º... 15º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 16kg Max. Wind Velocity 200Km/h 1550 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 16/18dBi FET0º/0º S-Wave 0709/U-65-16/18D-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.5dBi 16.2dBi 17.0dBi 17.6dBi 18.2dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.2º 5º 4.5º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 16/18dBi FET6º/6º 69 70 S-Wave 0709/U-65-16/18DT6-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.4dBi 16.1dBi 16.9 dbi 17.5dBi 18.1dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.2º 5º 4.5º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 15dB > 15dB > 15dB > 15dB > 15dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 16/18dBi VET0-10º/0-8º Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave 0709/U-65-16/18DV10/V8-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 15.5dBi 16.2dBi 17.0dBi 17.6dBi 18.2dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 5.1º 4.8º 4.3º Electrical Down Tilt 0-10º 0-10º 0-8º 0-8º 0-8º First Upper Sidelobe Suppression 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 21kg Max. Wind Velocity 200Km/h 1990 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 17/18dBi FET0º/0º 71 72 S-Wave 0709/U-65-17/18D-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.6dBi 17.3dBi 17.0dBi 17.6dBi 18.2dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 0º 0º 0º 0º 0º First Upper Sidelobe Suppression > 16dB > 16dB > 16dB > 16dB > 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 17/18dBi FET6º/6º S-Wave 0709/U-65-17/18DT6-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.6dBi 17.2dBi 17.0dBi 17.4dBi 18.1dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 6º 6º 6º 6º 6º First Upper Sidelobe Suppression > 14dB > 14dB > 14dB > 14dB > 14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
XXpol Panel 790-960/1710-2170 65º 17/18dBi VET0º-8º Adjust. Electrical Downtilt set by hand or by optional ACU 73 74 S-Wave 0709/U-65-17/18DV8-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 16.6dBi 17.3dBi 17.0dBi 17.6dBi 18.2dBi Horizontal 3dB Beam Width 68º 65º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.8º 4.3º Electrical Down Tilt 0-8º 0-8º 0-8º 0-8º 0-8º First Upper Sidelobe Suppression 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 790~960 790~960 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 4 X 7-16 DIN(F) 27kg Max. Wind Velocity 200Km/h 2590 X 295 X 145mm
Triple Band Antennas 6 Ports Dual Polarization +45 / 45 Your partner for Your Network Optimization
XXXpol Panel 790-960/1710-2170/1710-2170 65º 15.0dBi VET0º-15º Adjust. Electrical Downtilt set by hand or by optional ACU 75 76 S-Wave 0709/U/U-65-15DV15-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 2X14.5dBi 2X15.1dBi 4X13.9 dbi 4X14.2dBi 4X14.7dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 14.7º 13.9º 13.4º 13.0º 12.6º Electrical Down Tilt 0-15º 0-15º 0-15º 0-15º 0-15º First Upper Sidelobe Suppression 0º... 7º... 15º 16...15...14dB 0º... 7º... 15º 16...15...14dB 0º... 7º... 15º 16...15...14dB 0º... 7º... 15º 16...15...14dB 0º... 7º... 15º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 1710-1880MHz 790~960 790~960 1710-2170 1710-2170 1710-2170 1710-2170 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 6 X 7-16 DIN(F) 21kG Max. Wind Velocity 200Km/h 1690 X 295 X 145mm
XXXpol Panel 790-960/1710-2170/1710-2170 65º 16.0dBi VET0-8 /0-12 /0-12 Adjust. Electrical Downtilt set by hand or by optional ACU S-Wave 0709/U/U-65-16DV8/V12/V12-F Frequency Range 790-960 MHz 1710-2170MHz 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 2X15.5dBi 2X16.2dBi 4X15.2dBi 4X15.7dBi 4X16.3dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 10.6º 9.5º 9.3º 9.0º 8.6º Electrical Down Tilt 0-8º 0-8º 0-12º 0-12º 0-12º First Upper Sidelobe Suppression 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 6º... 12º 16...15...14dB 0º... 6º... 12º 16...15...14dB 0º... 6º... 12º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 1710-1880MHz 790~960 790~960 1710-2170 1710-2170 1710-2170 1710-2170 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 6 X 7-16 DIN(F) 26kG Max. Wind Velocity 200Km/h 2130 X 295 X 145mm
XXXpol Panel 790-960/1710-2170/1710-2170 65º 17.0dBi VET0-8 /0-10 /0-10 Adjust. Electrical Downtilt set by hand or by optional ACU 77 78 S-Wave 0709/U/U-65-17DV8/V10/V10-F 790-960 MHz 1710-2170MHz Frequency Range 790-896MHz 880-960MHz 1710-1880MHz 1850-1990MHz 1920-2170MHz Polarization ±45º ±45º ±45º ±45º ±45º Gain 2X16.7dBi 2X17.4dBi 2X16.1dBi 2X16.5dBi 2X16.4dBi 2X16.7dBi 2X16.8dBi 2X17.1dBi Horizontal 3dB Beam Width 67º 64º 66º 64º 60º Vertical 3dB Beam Width 8º 7.4º 5.1º 4.7º 4.3º Electrical Down Tilt 0-8º 0-8º 0-10º 0-10º 0-10º First Upper Sidelobe Suppression 0º... 4º... 8º 16...15...14dB 0º... 4º... 8º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB 0º... 5º... 10º 16...15...14dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB > 30dB > 30dB Cross-polar Ratio, 0º > 15dB > 15dB > 15dB > 15dB > 15dB Impedance 50Ω 50Ω VSWR < 1.5 < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc < -150dBc Max, Power 400W 200W 790-960MHz 1710-1880MHz 790~960 790~960 1710-2170 1710-2170 1710-2170 1710-2170 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1920-2170MHz Connector Type 6 X 7-16 DIN(F) 34kG Max. Wind Velocity 200Km/h 2870 X 295 X 145mm
Tri-Sector Antenna Dual Polarization +45 / 45 Your partner for Your Network Optimization
Xpol Tri-Sector 1710-2170 65º 18.0dBi VET0º-8º Adjust. Electrical Downtilt set by hand or by optional ACU 79 80 S-Wave U-65-18DV8S Frequency Range 1710-2170MHz 1710-2170MHz 1710-2170MHz Polarization ±45º ±45º ±45º Gain 17.8dBi 17.8dBi 17.8dBi Horizontal 3dB Beam Width 65º 65º 65º Vertical 3dB Beam Width 7.0º 7.0º 7.0º Electrical Down Tilt 0-8º 0-8º 0-8º First Upper Sidelobe Suppression 16dB 16dB 16dB Front to Back Ratio (180 ±30 ) > 25dB > 25dB > 25dB Isolation > 30dB > 30dB > 30dB Cross-polar Ratio, 0º ±60º Impedance 50Ω VSWR < 1.5 IMD3 @ 2 X 43dBm Carrier < -150dBc Max, Power 250W 1710-2170MHz 1710-2170MHz 1710-2170 1710-2170 1710-2170 1710-2170 1710-2170 1710-2170 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 7-16 DIN 1710-2170MHz Connector Type 6 X 7-16 DIN(F) 70kG Max. Wind Velocity 200Km/h Φ250 X 2230mm
Remote Electrical Tilt (RET) Your partner for Your Network Optimization
81 82 RET Products List Variable Electrical Tilt Antenna (VET Antenna) Antenna Control Unit (ACU) AISG Control Cable Assembly (CCA) Protocol Convert Adaptor (PCA ) Portable Control Unit (PCU) Smart Bias-Tee (SBT) 2) The following method does not need to use a long run AISG compliant CCA. The CCU, PCU or OMT uses a Smart Bias Tee (SBT) to connect to the RF cable and modulate the data through the cable. On the tower another SBT is used to demodulate the data, and is connected to the ACU through an AISG cable. The ACU then adjusts the electric tilt of the VET antenna. RET System 1.Connection of VET Antenna and ACU The Variable Electrical Tilt (VET) antenna can be adjusted when it is separated from the Antenna Control Unit (ACU). When the VET antenna is not connected to the ACU, its electrical down tilt angle can be adjusted manually by hand control. Antenna Control Unit (ACU) 3) AISG protocol is processed in the Base Station then through the RF cable to tower. On the tower a SBT is used to demodulate the data, and is connected to the ACU through an AISG cable. The ACU then adjusts the electric tilt of the VET antenna. AISG connector 2. RET System 1) The Central Control Unit (CCU), Portable Control Unit (PCU) or Operation & Maintenance Terminal (OMT) is connected to the ACU using an AISG compliant Control Cable Assembly (CCA). The ACU can then be commanded to adjust the electric tilt of the VET antenna. The CCU sends commands and data to the ACU using the computer s RS232, Ethernet or Wireless MODEM ports.
4) AISG protocol is processed in the Base Station and Remote Radio Unit (RRU). The RRU is connected to the ACU through an AISG cable. The ACU then adjusts the electric tilt of the VET antenna. Remote Site Control Change the electrical tilt or azimuth bearing of installed RET / RAS antennas. Remotely calibrate or re-configure installed devices. Batch Scheduling Quickly reconfigure a large number of sites for seasonal changes or event optimization. Schedule site polling to update control database. Remote Site Monitoring Monitor and report device alarms. Monitor and report network connectivity issues. 3. Operation and Maintenance Center (OMC) System OMC software from Rosenberger enables operators to remotely control and monitor AISG devices distributed throughout their network. Engineers using OMC software communicate via Ethernet to Center Control Units (CCU s) at each cell site to send and receive commands to RET, RAS, TMA and any other installed AISG devices. The system includes a user friendly alarm interface to manage error messages and network connectivity problems as well as provides a centralized database for site configuration data. Alarm Management User friendly interface to receive and interpret error messages. Ability to assign severity levels to each defined error code. Alarm filtering by area, time or severity level. Site History Alarm history Site change history Site Configuration Site name, location, GPS coordinates. Store and maintain listing of installed equipment. Store site access procedures / protocols. Maintain internal and external contact information. Site Management Add new sites or remove existing sites. Maintain and communicate site status. Assign logical grouping by Region, Area, City, etc. User Management Add / Delete users to the system. Assign and manage access privileges. Assign and manage user passwords. Reporting Query database and filter results to quickly review desired data. Produce formatted reports showing site information, tilt changes, etc. Export data to EXCEL for additional processing.
Antenna Control Unit (ACU) 83 84 Main Features The Antenna Control Unit (ACU) is used with Rosenberger base station antennas with adjustable electrical down-tilt and appropriate mechanical interfaces. Compliant to AISG 1.1 and 3GPP/AISG 2.0 Compact size Daisy Chain feasibility Suitable for operation under outdoor conditions Type No S-Wave ACU-001 S-Wave ACU-002 Protocols Compliant to AISG 1.1 and 3GPP/AISG 2.0 Logical Interface Ex Factory 1) AISG 1.1 3GPP/AISG 2.0 Input Voltage Range 10... 30 V (pin 1, pin 6) Power Consumption Connectors 2) Hardware Interfaces Adjustment Time (Full Range) < 2 W (stand by); <15 W (motor activated) 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: female RS 485A/B (pin 5, pin 3); power supply (pin 1, pin 6); DC return (pin 7); according to AISG 120 sec (typically, depending on antenna type) Adjustment Cycles > 50,000 Environmental Specifications Operating Temperature Range Storage Temperature Range Protection Class -40 C to +60 C -40 C to +85 C IP65(with antenna) Input 2 8 pin connector according to IEC 60130-9 Connector Position Color Housing Material Bottom RAL 7035, light grey 161 x 72 x 58mm 350g Profile: Aluminum; Cover: Zinc die cast
AISG Control Cable Assembly (CCA) Main Features AISG RET Control Cable, 1 m Feeds data and power to RET system components AISG and RoHS compliant Type No 8Pin(F)-1000-8Pin(M)-AISG Protocol 3GPP/AISG 2.0/AISG 1.1 Voltage, Maximum 300V Environmental Specifications Operating Temperature Range -40 C to +70 C (-40 F to +158 F) Protection Class IP 67 AISG Connector A AISG Connector B 8pin DIN Female 8pin DIN Male Braid Coverage 85% Data Conductor Type 0.32 mm² (24 AWG) twisted pair Data Conductors, Quantity 2 Power Conductor Type 0.75 mm² (20 AWG) stranded Power Conductors, Quantity 3 Total Conductors, Quantity 5 Shield Material Jacket Material Color Diameter Over Jacket Aluminum Fire retardant PU Black 8.000 mm Length 1.0m
Portable Control Unit (PCU) 85 86 Main Features AISG1.1 and 3GPP/AISG2 capable Portable and lightweight Rechargeable LI-ION battery No external power source required Backlight LCD display Pushbutton control Type No Power S-Wave PCU-ANT-001 Rechargeable battery 14.4V Li 2Ah Power Supply To PCU DC24V, 2.7A Output Voltage to Antenna Maximum Output Current Output Protection Interface to Antenna Tilt Reading Resolution AISG female Pin 1: 12V ± 1V AISG female Pin 6: DC 24V ± 1V, Battery 15V±1V 2A Over-current and low-voltage protection AISG1.1 / 3GPP AISG2.0 RS485 (AISG female pins 3 and 5) @ 9600 baud Power supply (AISG female pin 6/ pin 1) 0.1 steps AISG Output 8 pin female DIN 60130-9 Power Display 2-pole socket, 5.7mm/2.0mm Monochrome graphic LCD Environmental Specifications Operating Temperature Range 0 C to +45 C Storage Temperature Range -20 C to +65 C (Portable Controller Unit) Housing Material 211.5 x 92 x 34.5mm 550g ABS
Protocol Convert Adaptor (PCA ) Main Features The PCA is an integral part of the Rosenberger remote antenna control system. The device links the PC to the AISG antenna system and is used in coordination with Rosenberger s OMT-ALD software to control ALD Compliant with AISG 1.1 and 2.0 standards Compact size Daisy Chain feasibility Simple connection to any USB port of the PC driver provided Carried from site to site for RET antenna setup and optimization Pushbutton control Type No S-Wave PCA-001 Protocol AISG 1.1 AISG 2.0 Input Voltage Range 12V pin 1, 24V pin 6 Output Current at Voltage 2.7 A @ 24 V Hardware Interfaces RS 485A/B(pin 5, pin 3); power supply(pin 1, pin 6); DC return(pin 7) Electrical Safety Standard IEC 60950 1 Power Supply DC Jack Environmental Specifications Operating Temperature Range Relative Humidity 0 C to +40 C Up to 95%, noncondensing Connector Color weight Housing material 1 8 pin connector according to IEC 60130-9 conforms to AISG RF-connector SMA RAL 7035,lightgrey 151 X 52.4 X 49mm 290g Profile: Aluminum; Cover: Zinc diecast Includes Protocol Convert Adapter External power supply (24 VDC / 65W) AC power cable USB cable CD-ROM (with PCA software, drivers, and manual) Installation guide Carrying case
Smart Bias-Tee (SBT) 87 88 Main Features Conversion between OOK and RS485 standard signal High PIM rejection performance Low insertion loss and high output power Feeding DC to supply cable Built-in lighting protection Simple installation Type No Frequency Return Loss/VSWR Impedance Insertion Loss SBT-6F-D-01 800-2170MHz Smart Bias Tee 806 to 960MHz and 1710 to 2170MHz < -20dB/<1.22 50 Ω < 0.2dB PIM < -160dBc(3rd order, wit 2*20W ) Power Handl ng 55dBm(Average RMS) Power Supply 9-30V Current Consumption 50mA Current Handling 1.3A Modem Communication 3GPP TS 25.461 Environmental Specifications Operating Temperature Range Storage Temperature Range -40 C to +60 C -40 C to +85 C Relati e Humidity 5% - 95% Barometric Pressure Storage Temperature Range 55 KPa -106KPa Indoor or Outdoor (IP66) Connectors Type MTBF Ingress Protection Packing Port1 DIN 7-16 male, Port2 7-16 female, Port DC/ACU 8-pin male >500,000 hrs IP66 1 Pce in box
INSTALLATION KITS Your partner for Your Network Optimization
89 90 Installation Instruction 1. Assemble the mounting bracket kit enclosed in the antenna package per the instructions, and verify that each bolt, washer and nuts are tightened securely. Attach the mounting bracket to the back of the antenna as in the following examples. 2. Connect the jumpers to 7/16 DIN connectors of the antenna. Completely wrap the connectors with weather proof glue and tape as needed.
3. Hoist the antenna with jumpers to the installation location. Attach the antenna to the mast. Please note that the nuts should not be tightened until step 4 is completed. 4. Adjust the azimuth and mechanical down-tilt angle as required and restrain the jumpers connected to the antenna as appropriate. For Variable Electrical Tilt antennas without a Remote Control Unit, adjust the electrical down tilt angle as required.
91 92 5. Tighten each nut to the specific torque Nut M6 M8 M10 M12 Proposed Torque 8Nm 20Nm 50Nm 90Nm Safety Warning THE INSTALLATION OF THIS PRODUCT NEAR ANYPOWER LINES IS DANGEROUS. Select your installation site carefully; the distance from power lines should be at least twice the height of the antenna and mast combined. DO NOT use a metal ladder. DO NOT work on a wet or windy day. DO dress properly (shoes with rubber soles and heels, rubber gloves, long sleeve shirt or jacket). When the system is operational, avoid standing directly in front of the antenna. Strong RF fields are present when the transmitter is on. Installation Kits Mounting bracket P/N S-Wave 67-1 S-Wave 67-2 S-Wave 67-3 S-Wave 67-5 S-Wave 70-1 (kg) 4.6 9.4 1.9 5.2 2.4 CDMA800 & CDMA800& CDMA800 & TD Antennas GSM1800 & UMTS Antenna Series GSM900 65 Antennas GSM900M 33 High gain Antennas; Multi Band VET High gain Antennas GSM900 & GSM1800 Low gain Antennas Suitable Mast Diameter φ50~φ110 mm φ50~φ110 mm φ50~φ110 mm φ50~φ110 mm φ50~φ110 mm Material Q235/SS304 Q235/SS304 Q235/SS304 Q235/SS304 Q235/SS304 Fix point 2 3 1 2 2 Installation Tool Wrench [13, 14, 16] Wrench [13, 14, 16] Wrench [13, 14, 16] Wrench [13, 14, 16] Wrench [13, 14, 16]
Rosenberger SERVICE Your partner for Your Network Optimization
93 94 Rosenberger offers professional services that improve network design, reliability, scalability and efficiency. Our service core competences include: Network optimization Technical consultation Customized product design Installation & commissioning Onsite training & supervision System troubleshooting After-sales services In addition, we also offer professional training, technical support and workshops for distributors and agents. We are committed to offering our services in anyway, anywhere and at anytime. Rosenberger is much more than just a supplier Rosenberger is a valued development partner and we will strive to devote all effort to meet new challenges in order to scale to new heights.
Rosenberger Asia Pacific Electronic Co., Ltd. No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone Beijing, China 101300 Tel : (+86 10) 80481995 Fax : (+86 10) 80497052 Email: sales@rosenbergerap.com Rosenberger (Shanghai) Technology Co.,Ltd No. 303, Xinke Road, Qingpu Industrial Zone Shanghai, China 201707 Tel : (+86 21) 69214567 Fax : (+86 21) 69212923 Rosenberger Asia Pacific Electronic Co., Ltd. Shanghai Division B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park Shanghai, China 201201 Tel : (+86 21) 58995997 Fax : (+86 21) 58995594 Rosenberger Asia Pacific Electronic Co., Ltd. Dongguan Division 3rd Floor, Building E, Pingqian Industrial Park, Dongkeng Town Dongguan, Guangdong Province, China Tel : (+86 769) 82802098 Fax : (+86 769) 82802099 Rosenberger All rights reserved. 2 nd Edition, 2012 Please visit our website: www.rosenbergerap.com