Etching Titanium with HF and Nitric Acid Solutions Part 1. Randy Markle Chemcut

Similar documents
Etching Etch Definitions Isotropic Etching: same in all direction Anisotropic Etching: direction sensitive Selectivity: etch rate difference between

Photolithography. Class: Figure Various ways in which dust particles can interfere with photomask patterns.

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

Lecture 11. Etching Techniques Reading: Chapter 11. ECE Dr. Alan Doolittle

AUTOCLAVE CORROSION INHIBITOR EVALUATION

North American Stainless

THE USE OF OZONATED HF SOLUTIONS FOR POLYSILICON STRIPPING

TAIYO PSR-4000 AUS703

Dry Etching and Reactive Ion Etching (RIE)

Technical Data BLUE SHEET. Martensitic. stainless steels. Types 410, 420, 425 Mod, and 440A GENERAL PROPERTIES APPLICATIONS PRODUCT FORM

North American Stainless

ALLOY C276 DATA SHEET

The Empirical Formula of a Compound

SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS. W. Brian James Hoeganaes Corporation. Cinnaminson, NJ 08077

Electroplating with Photoresist Masks

LASER CUTTING OF STAINLESS STEEL

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

North American Stainless

Chapter 5 - Aircraft Welding

Anodizing Reference Guide

Process Control For Phosphate Coating A new military specification for phosphate coatings...

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

IB Chemistry. DP Chemistry Review

Lecture 35: Atmosphere in Furnaces

Surface Treatment of Titanium

TiO 2. : Manufacture of Titanium Dioxide. Registered charity number

North American Stainless

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Technical Data Sheet L Top coats. Mat Clear

AUSTENITIC STAINLESS DAMASCENE STEEL

Safety, Cleaning, and Chemical Disposal Procedures

A. Work on this project shall consist of, but is not limited to, the following:

MATERIAL SAFETY DATA SHEET Product Code: 10033

Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)

Electron Beam and Sputter Deposition Choosing Process Parameters

Basic Properties and Application of Auto Enamels

Lecture 30: Cleanroom design and contamination control

Revised: June 6, 2007

GENERAL PROPERTIES //////////////////////////////////////////////////////

This test may be carried out with the IGT printability testers A1-3, A2-3 and AIC2-5 with the accompanying inking unit AE.

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

3.8 HSP (High Solids Polyurethane)

Phosphoric Acid Anodized Aluminum Honeycomb

North American Stainless

MICROPOSIT LOL 1000 AND 2000 LIFTOFF LAYERS For Microlithography Applications

Operator Quick Guide EC SENSOR

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

INTRODUCTION SOME USES OF SPRAY NOZZLES INTRODUCTION TYPES OF SPRAY NOZZLES

Hazard Warning Signage Guidelines

Chemical Surface Treatment of Stainless Steel

ALLOY 2205 DATA SHEET

Module 7 Wet and Dry Etching. Class Notes

COATED CARBIDE. TiN. Al 2 O 3

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

GRIP-GARD BC BASECOAT CHROME

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

Laboratory Glassware Cleaning

How To Test A Base Axe

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Hazardous Chemical Reactions in Art

Metal Rescue Rust Remover Technical Data

WELDING & CUTTING MAIN EQUIPMENT

AISI O1 Cold work tool steel

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Sinterstation. Pro Direct Metal SLM System

PRODUCT DATA SHEET DESCRIPTION:

FLEXIBLE CIRCUITS MANUFACTURING

Appendice Caratteristiche Dettagliate dei Materiali Utilizzati

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

TECHNICAL DATA SHEET DURO HARD CHROME PLATING PROCESS

Section 4: NiResist Iron

39. The determination of copper in brass

QUALANOD SPECIFICATIONS UPDATE SHEET Nº 9 Edition page 1/5 COLD SEALING PROCESS

Separation of Amino Acids by Paper Chromatography

III. Wet and Dry Etching

Evaluating Surface Roughness of Si Following Selected Lapping and Polishing Processes

CLEANING AND SANITIZING

Use of Carbon Nanoparticles for the Flexible Circuits Industry

Molar Mass and the Ideal Gas Law Prelab

Johnson Controls Parts Centre. Sabroe S68 refrigeration oil

Nomex KD Technology. DuPont TM. DuPont s Heritage in Hot Gas Filtration Application. For over 4 decades, a filter media made of Nomex

Chapter 1 The Atomic Nature of Matter

Urea and Nitric Acid Plants: Improvement of Shut-Down, Revamping, Debottlenecking and Refurbishment

WHAT IS IN FERTILIZER OTHER THAN NUTRIENTS?

CHAPTER 5. OVERVIEW OF THE MANUFACTURING PROCESS

SELECTRON Oberflächentechnik

EMERGENCY PHONE: or (651) (24 hours)

LISLE CORPORATION. Safety Data Sheet Issued: May 25, 2015 Supersedes: March 15, Page 1. Section 1 - PRODUCT AND COMPANY IDENTIFICATION

General Chemistry Lab Experiment 6 Types of Chemical Reaction

EXPERIMENT #9 CORROSION OF METALS

Equilibria Involving Acids & Bases

Determining the Right Molding Process for Part Design

3 Scotch-Weld TM. Structural Adhesive Film AF AF Technical Datasheet December 2009

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Determination of the Mass Percentage of Copper in a Penny. Introduction

Technical Data May, 2015

THE HUMIDITY/MOISTURE HANDBOOK

Transcription:

Etching Titanium with HF and Nitric Acid Solutions Part 1 Randy Markle Chemcut Chemcut has been building hydrofluoric acid etching equipment since the 1960 s. HF was first used by the glass industry to produce a non- glare surface on television tubes. It has now become a viable chemical for the processing of silicon, in the solar industry, and titanium and memory metals in the medical industry. Our experience has shown that HF is seldom used by itself. It is usually combined with another chemical to produce an etching or surface treatment solution. The mixture of HF and nitric acid is becoming quite prevalent. Chemcut decided to study the effects of etching titanium using this solution. Hydrofluoric acid (HF) is the primary chemical needed to etch titanium. The etching reaction is shown as: Ti + 3HF TiF 3 + 3/2H 2 1 Where the etching of titanium, with HF, produces titanium trifluoride and hydrogen gas. Although HF, by itself, will etch titanium, there are some disadvantages to using HF alone. First, there is the formation of hydrogen gas that is flammable and explosive. This can create a potential fire hazard. Secondly, the HF tends to dissipate quickly, requiring regular chemistry additions. Thirdly, the etch rate is relatively slow. And lastly, the resulting surface finish may be undesirable. To offset some of these disadvantages, nitric acid is added to the HF solution. This reaction is shown as: Ti + 6HF + 4HNO 3 H 2 TiF 6 + 4NO 2 + 4H 2 0 1 Here the etching of titanium produces hexafluorotitanic acid, nitrogen dioxide, and water. With this solution, the HF tends to be more stable, the hydrogen gas is eliminated, and the etch rate increases. The purpose of this evaluation was to record the effects of different chemical concentrations on the etch rate and surface finishes when etching titanium with a hydrofluoric acid /nitric acid solution. Undercut was not evaluated at this time, because the dry film used was not compatible with the HF. It allowed the fluoride ions to penetrate the resist and which caused loss of adhesion. Undercut may be evaluated at a later date.

The material used for the testing was grade 2, commercially pure titanium, 0.020 (0.508mm) and 0.035 (0.889mm) in thickness. It was purchased with a mill finish. The constituents are; titanium 98.9% min, carbon 0.08% max, oxygen 0.25% max, nitrogen 0.03% max, iron 0.3% max, and hydrogen 0.015% max. Its density is 0.163 lb/in 3, its hardness is Rockwell B68 to B80, and its yield strength is 40,000psi min. The titanium was prepared for etching in the following manner. The titanium was sheared into 6 x 6 sheets. The sheets were then degreased, by hand, with a solvent, and soaked in a phosphoric acid based cleaner for two minutes. They were then rinsed and dried. The thickness of each sheet was measured in four places, with a micrometer, averaged and recorded. One side of each sheet was then masked from the etching solution. Two sheets were etched under each set of chemical concentrations. The masking was then removed, and the resulting thickness measured, in four locations, and averaged. The amount of removed material was then divided by the etch time to give an etch rate in microns or mils per minute. The etching solutions were prepared with hydrofluoric acid (49%, s.g. 1.18), nitric acid (68%, s.g. 1.41), and water, by weight percent. Additions were made during the testing to adjust and maintain acid concentrations. The etching was done in a Chemcut model 2315. The etch chamber has four spray tubes, top and bottom, running parallel to the direction of travel. The spray tubes also oscillate perpendicular to the direction of travel. Each spray tube contains four, 80 full cone nozzles rated at 2.84 l/min (0.75 gal/min) at 2.76 bar (40psi). The panels were etched using the top spray only at a pressure of 2.07 bar (30psi). The oscillation rate was 30 sweeps per minute and the etching temperature was 43.3 C (110 F). The effective length of the etching chamber is 21 (53.34cm). Following is a small chart showing the HF and nitric acid concentrations that were evaluated. HF HNO 3 3% 0%, 3%, 6%, 10%, 15% 4.21% 20% 5% 0%, 3%, 6%, 10%, 15%, 20% 10% 0%, 3%, 6%, 10%, 15%, 20%

This chart shows the average thickness before etching, the average thickness after etching, the average thickness (material) loss, and the calculated etch rate for the 3% HF solutions. Etching Average thickness Average thickness Average thickness Calculated Etch time Solution before etching after etching loss etch rate Minutes 507.7µ 418.6µ 89.2µ 8.92µ/min 3% HF (19.99 mils) (16.48 mils) (3.51 mils) (0.351 mils/min) 10 3% HF + 536.2µ 364µ 172.5µ 17.25µ/min 3% Nitric (21.11 mils) (14.33 mils) (6.79 mils) (0.68 mils/min) 10 3% HF + 524.3µ 313.9µ 210.3µ 21.03 µ/min 6% Nitric (20.64 mils) (12.36 mils) (8.28 mils) (0.83 mils/min) 10 3% HF + 535.4µ 290.3µ 245.1µ 24.51µ/min 10% Nitric (21.08 mils) (11.43 mils) (9.65 mils) (0.97 mils/min) 10 3% HF + 517.1µ 247.7µ 270.8µ 27.08 µ/min 15% Nitric (20.36 mils) (9.75 mils) (10.66 mils) (1.07 mils/min) 10 4.21% HF + 536.2µ 130.6 µ 405.9 µ 40.59 µ/min 20% Nitric (21.11 mils) (5.14 mils) (15.98 mils) (1.6 mils/min) 10

The etch rate at each chemical concentration is also show on the following graph. Titanium Etch Rate - 3% HF 45 40 40.59 35 Etch Rate (µ/min) 30 25 20 15 10 5 8.89 17.25 21.03 24.51 27.08 0 3%HF 3%HF&3%HNO3 3%HF&6%HNO3 3%HF&10%HNO3 3%HF&15%HNO3 4.21%HF&20%HNO3 Etching Solution

Following is the same information for the 5% HF and 10% HF testing. Etching Average thickness Average thickness Average thickness Calculated Etch time Solution before etching after etching loss etch rate Minutes 883.6µ 717.8µ 166.1µ 16.61µ/min 5% HF (34.79 mils) (28.26 mils) (6.54 mils) (0.654 mils/min) 10 5% HF + 887.7µ 671.6µ 216.2µ 21.62µ/min 3% Nitric (34.95 mils) (26.44 mils) (8.51 mils) (0.85 mils/min) 10 5% HF + 884.7µ 529.3µ 355.3µ 35.53 µ/min 6% Nitric (34.83 mils) (20.84 mils) (13.99 mils) (1.4 mils/min) 10 5% HF + 887.0µ 431.0µ 455.9µ 45.59µ/min 10% Nitric (34.92 mils) (16.97 mils) (17.95 mils) (1.8 mils/min) 10 5% HF + 887.2µ 376.2µ 511.3µ 51.13 µ/min 15% Nitric (34.93 mils) (14.81 mils) (20.13 mils) (2.01 mils/min) 10 5% HF + 886.2µ 620.8 µ 265.4 µ 53.1 µ/min 20% Nitric (34.89 mils) (24.44 mils) (10.45 mils) (2.09 mils/min) 5

Titanium Etch Rate - 5% HF 60 50 51.13 53.1 45.59 Etch Rate (µ/min) 40 30 20 21.62 35.53 10 16.61 0 5%HF 5%HF&3%HNO3 5%HF&6%HNO3 5%HF&10%HNO3 5%HF&15%HNO3 5%HF&20%HNO3 Etching Solution

Etching Average thickness Average thickness Average thickness Calculated Etch time Solution before etching after etching loss etch rate Minutes 890.5µ 790.5µ 100.1µ 20.0µ/min 10% HF (35.06 mils) (31.12 mils) (3.94 mils) (0.79 mils/min) 5 10% HF + 888.7µ 652.8µ 236.0µ 47.2µ/min 3% Nitric (34.99 mils) (25.7 mils) (9.29 mils) (1.86 mils/min) 5 10% HF + 886.5µ 283.7µ 603µ 120.6 µ/min 6% Nitric (34.9 mils) (11.17 mils) (23.74 mils) (4.75 mils/min) 5 10% HF + 886.5µ 563.1µ 323.5µ 161.75µ/min 10% Nitric (34.9 mils) (22.17 mils) (12.74 mils) (6.37 mils/min) 2 10% HF + 890.0µ 487.4µ 402.6µ 201.3 µ/min 15% Nitric (35.04 mils) (19.19 mils) (15.85 mils) (7.93 mils/min) 2 10% HF + 888.5µ 482.1 µ 406.5 µ 203.3 µ/min 20% Nitric (34.98 mils) (18.98 mils) (16.0 mils) (8.0 mils/min) 2

Titanium Etch Rate - 10% HF 250 Etch Rate (µ/min) 200 150 100 50 47.2 120.6 161.75 201.3 203.3 0 10%HF 20 10%HF&3%HNO3 10%HF&6%HNO3 10%HF&10%HNO3 10%HF&15%HNO3 10%HF&20%HNO3 Etching Solution The

The following graph shows how the etch rate of each concentration compares to the others. Titanium Etch Rate (µ/min) 250 Etch Rate (µ/min) 200 150 100 3% HF 5% HF 10% HF 50 0 0% HNO3 3% HNO3 6% HNO3 10% HNO3 15% HNO3 20% HNO3 Percent Nitric Acid 4.21% HF A As shown by the graph above, as the nitric acid concentration increases, so does the etch rate. With no nitric acid, the etch rates are similar at the tested HF concentrations

The etch rate increase percentage begins to decline after reaching the 10% nitric acid level. The following chart and graph illustrates this point. Etch Rate Increase - Percentage %HNO 3 3% HF 5% HF 10% HF 3% 93.4 30.2 136 6% 21.9 64.3 155.5 10% 16.5 28.3 34.1 15% 10.5 12.2 24.5 20% 3.4 1 Percent Etch Rate Increase 400 350 300 Percentage Increase 250 200 150 100 3% HF 5% HF 10% HF 50 0 3% 6% 10% 15% 20% Nitric Acid Concentration This graph shows that the increase in etch rate begins to level off above the ten percent nitric acid concentration. This holds true for each concentration of HF.

While measuring the panels after etching, it was noticed that as the chemical concentrations increased, the measurements showed more inconsistency. The standard deviations of each set of measurements were calculated and graphed to create a visual interpretation. Standard Deviation - Microns 70.0 Standard Deviation (microns) 60.0 50.0 40.0 30.0 20.0 10.0 0.0 3%HF 5%HF 10%HF 0% Nitric 3% Nitric 6% Nitric 10% Nitric 15% Nitric 20% Nitric Percent Nitric Acid 4.21% HF It can be seen, that as the nitric acid concentration increases, the etch rate increases and the surface attack becomes more erratic and uncontrollable. The second part of the evaluation was to see the how the various chemical concentrations affected the etched surface. The following photographs show a side- by- side comparison at the tested HF and nitric concentrations.

3% HF 0% Nitric 10% Nitric 15% Nitric 5% HF 0% Nitric 10% Nitric 20% Nitric 10% HF 0% Nitric 10% Nitric 20% Nitric

Without the nitric acid being present, the titanium surface is very rough and nodular in appearance. As the nitric acid concentration increases, the surface roughness decreases to the point of creating a surface that is almost reflective. The following chart shows a comparison of the average roughness using the various chemical concentrations. Mill 5% HF& 5% HF& Finish 5% HF 10% HNO3 20% HNO3 Ra (microinches) 13.63 112.3 34.7 56.85 Mill 10% HF& 10% HF& Finish 10% HF 10% HNO3 20% HNO3 Ra (microinches) 13.63 120.82 35 39.54 Summary Etching titanium with hydrofluoric acid is a slow process and produces a by- product of hydrogen gas. It also produces a rough surface finish. The addition of nitric acid increases the etching rate, eliminates the formation of hydrogen gas, and produces a smoother surface finish. Nitric acid concentrations above ten percent did little to increase the etching rate. At the fifteen and twenty percent level, the etch rate begins to stabilize, however, it becomes more erratic and uncontrollable. Also, as the HF concentrations increased, titanium oxide formed on the material surface. This white oxide may be undesirable and is very difficult to remove. The undercut characteristics were not evaluated because the photoresist, that was used, was not compatible with the process. Recommendation To maintain a good controllable etch rate, when etching grade 2 titanium, a recommended etching solution is 3-5% HF with 10% nitric acid. 1 Allen D M, 1986, The Principles and Practice of Photochemical Machining and Photoetching, Pg. 97