Keysight E5867A Removable Hard Drive SSD for Series Logic Analyzers. Installation Guide

Similar documents
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Wall-Mounting your HP computer. User Guide

StorTrends 3400 Hardware Guide for Onsite Support

About this Manual. Support for Your Product

Compaq Presario Desktop Products. Upgrading and Servicing Guide

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Benchtop Computer Monitor Generator

HP UPS R1500 Generation 3

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

UPGRADING AND SERVICING GUIDE

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

HP SATA/SAS hard drive and Solid State Drive installation

Upgrading and Servicing Guide

Power Supply Guide Version 1.0 for D-Show

USB to IDE or SATA Adapter

Safety Precautions WARNINGS

HP 22-in-1 Media Card Reader

AGILENT E5071C ENA NETWORK ANALYZER

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Model 1756 Test Lead Kit

PXI -1000B AC POWER SUPPLY SHUTTLE

Small form factor bay converter and hard drive installation

Memory Modules User Guide

Copyright 2007 Hewlett-Packard Development Company, L.P. Windows is a U.S. registered trademark of Microsoft Corporation.

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

Universal Serial Bus (USB) to DH-485 Interface Converter

NFC Communication Tray Model: HHX-IT3-Z

FW-310. Appliance Installation Guide

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Mini-led spotlight with magnetic base

Keysight N9911X Economical Waveguide Calibration Components

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

How To Use An Esata External Hard Drive Enclosure (I386) With A Usb 2.0 And Usb 2/1.1 Hard Drive (I219) On A 2.5\" Hard Drive On A Mini Hard Drive Or An Ip

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

How To Use A Cdm250 Digital Multimeter

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

PrintPAD CN3/4/3e/4e. User Guide

MB169B+ USB Monitor. User Guide

Front Panel Board Cable Replacement Instructions

EPSON Stylus. Start Here

Recovery BIOS Update Instructions for Intel Desktop Boards

Unpack and Install the Devices, Accessories, and Cables

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

2GB MP3 Player USER GUIDE

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Agilent OpenLAB. Data Store. Disaster Recovery Plan

Agilent P940xA/C Solid State PIN Diode Switches

Hard Disk Drive (HDD)

User Manual. CFG253 3 MHz Function Generator

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

IDE ATA/133 Controller

WHITE PAPER. HP Guide to System Recovery and Restore

iosafe Solo External Hard Drive

i410/i1010 AC/DC Current Clamp

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

3 WATT LED SPOTLIGHT Model No. SLM

SATA PCI Express Adapter PEXSATA22I

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

Agilent 82357B USB/GPIB Interface

Sunny Boy Accessories SMA POWER BALANCER

P O W E R S U P P L Y M A N U A L

BroadBand PowerShield. User Manual

Instructions A Amp AC/DC Current Probe

Serial ATA PCI Quick Installation Guide

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

Dolphin 9900 Mobile Computers

Wireless Optical Travel Mouse

Installation Guide. Keysight Software

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

Alarm Clock USER GUIDE

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

Stonesoft Guide. 3G Modem Guide

Instructions & Safety Information Models A220-20D and A220-20L Version 2

USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure

IEEE1394A FireWire/Hi-Speed USB Hard Drive Data Encrypt Enclosure

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

UniStream CPU-for-Panel

RDC-7 Windows XP Installation Guide

1789 Norwood Avenue Itasca, Illinois Customer Service:

Point of View Mobii 10 Tegra Tablet. Notice... 2

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Leak Detection System

MIC-WKT and MIC-WKT-IR

Protocol Logging and Analysis Software

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Digital Photo Picture Frame. Operation Manual

3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support

USB 3.0 to SATA or IDE Hard Drive Adapter Converter

Getting Started. rp5800, rp5700 and rp3000 Models

User Manual USB Laptop KVM Switch. GCS661U Part No. M1069

Transcription:

Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Notices Keysight Technologies 2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws. Manual Part Number E5867-97001 Edition First Edition, August 2016 Printed in Malaysia Published By: Keysight Technologies Plot No. CP-11, Sector- 8, IMT Manesar, Gurgaon - 122051, India Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Rights The Software is "commercial computer software," as defined by Federal Acquisition Regulation ("FAR") 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement ("DFARS") 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.keysight.com/find/sweula. The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data. 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Safety Summary General Before Applying Power Ground the Instrument Fuses Do Not Operate in an Explosive Atmosphere Do Not Remove the Instrument Cover Cleaning Do Not Modify the Instrument In Case of Damage The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings or operating instructions in the product manuals violates safety standards of design, manufacture, and intended use of the instrument. Keysight Technologies assumes no liability for the customer's failure to comply with these requirements. Product manuals are provided with your instrument on CD-ROM and/or in printed form. Printed manuals are an option for many products. Manuals may also be available on the Web. Go to www.keysight.com and type in your product number in the Search field at the top of the page. Do not use this product in any manner not specified by the manufacturer. The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions. Verify that all safety precautions are taken. Make all connections to the unit before applying power. Note the instrument's external markings described in Safety Symbols. If your product is provided with a grounding type power plug, the instrument chassis and cover must be connected to an electrical ground to minimize shock hazard. The ground pin must be firmly connected to an electrical ground (safety ground) terminal at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury. See the user's guide or operator's manual for information about line-fuse replacement. Some instruments contain an internal fuse, which is not user accessible. Do not operate the instrument in the presence of flammable gases or fumes. Only qualified, service-trained personnel who are aware of the hazards involved should remove instrument covers. Always disconnect the power cable and any external circuits before removing the instrument cover. Clean the outside of the instrument with a soft, lint-free, slightly dampened cloth. Do not use detergent or chemical solvents. Do not install substitute parts or perform any unauthorized modification to the product. Return the product to an Keysight Sales and Service Office for service and repair to ensure that safety features are maintained. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 3

CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could resul t in personal injury or death. Do not proceed beyond a WARNING notice until the ind icated cond itions are fully understood and met. Safety Symbols Table 1 Safety Symbol Symbol Description Direct current Alternating current Both direct and alternating current Three phase alternating current Three phase alternating current Earth ground terminal Protective earth ground terminal Frame or chassis ground terminal Terminal is at earth potential 4 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Symbol Description Equipotentiality N L Neutral conductor on permanently installed equipment Line conductor on permanently installed equipment On (mains supply) Off (mains supply) Standby (mains supply). The instrument is not completely disconnected from the mains supply when the power switch is in the standby position In position of a bi-stable push switch Out position of a bi-stable push switch Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Caution, refer to accompanying documentation Caution, risk of electric shock Do not apply around or remove from HAZARDOUS LIVE conductors Application around and removal from HAZARDOUS LIVE conductors is permitted Caution, hot surface Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 5

Symbol Description Ionizing radiation CAT I CAT II CAT III CAT IV IEC Measurement Category I Measurement Category II Measurement Category III Measurement Category IV 6 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Compliance and Environmental Information Table 2 Compliance and Environmental Information Safety Symbol Description CSA is the Canadian certification mark to demonstrate compliance with the Safety requirements. The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australia EMC Framework regulations under the terms of the Radio Communication Act of 1992. CE compliance marking to the EU Safety and EMC Directives. ISM GRP-1A classification according to the international EMC standard. ICES/NMB-001 compliance marking to the Canadian EMC standard. Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 7

8 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Contents 1 Handling the Removable Hard Drive SSD 2 Installing the Hard Drive Protecting Against Electrostatic Discharge (ESD) 11 Protecting Against Contamination of the Edge Connector 11 Protecting Against Physical Shock 12 Step 1. Back up data for transfer to new hard drive SSD 14 Step 2. Power OFF the 16860 logic analyzer 14 Using the Windows Shutdown 15 Using a Short Press of the Power Button 15 Using a Long Press of the Power Button 15 Unplugging the Power Cord or Power Loss 16 Step 3. Remove the current hard drive SSD 16 Step 4. Install the new hard drive 17 Step 5. Power on the 16860 logic analyzer 19 Step 6. Perform the first-time set up steps 19 Step 7. Perform the first-time set up proced ures 19 Step 8. Restore data 19 Step 9. Install any add itional application software 19 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 9

Contents 10 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 1 Handling the Removable Hard Drive SSD For the integrity of the data on your hard disk drive, Keysight recommends that you take the following precautions while handling and storing the hard disk drives: Store unused hard disk drives in the shipping container. Protect the hard disk drive from electrostatic discharge (ESD). Protect the hard disk drive s edge connectors from physical contamination. Protect the hard disk drive from physical shock. Protecting Against Electrostatic Discharge (ESD) CAUTION Electrostatic discharge can damage electronic components. Use grounded wrist straps and mats when handling electronic components. Protecting Against Contamination of the Edge Connector CAUTION The hard drive SSD edge connector is sensitive to ESD and mechanical or material contamination. Take precautions to protect the edge connector from contamination during handling and storage.

1 Handling the Removable Hard Drive SSD Protecting Against Physical Shock CAUTION While operating, do not expose the hard disk drive to more than 5 to 500 Hz at 0.3 g rms. 12 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 2 Installing the Hard Drive Step 1. Back up data for transfer to new hard drive SSD / 14 Step 2. Power OFF the 16860 logic analyzer / 14 Step 3. Remove the current hard drive SSD / 16 Step 4. Install the new hard drive / 17 Step 5. Power on the 16860 logic analyzer / 19 Step 6. Perform the first-time set up steps / 19 Step 7. Perform the first-time set up procedures / 19 Step 8. Restore data / 19 Step 9. Install any additional application software / 19 CAUTION Electrostatic discharge can damage electronic components. Use grounded wrist straps and mats when handling electronic components.

2 Installing the Hard Drive Step 1. Back up data for transfer to new hard drive SSD Step 2. Power OFF the 16860 logic analyzer 1 Close the Keysight Logic and Protocol Analyzer application software. 2 Back up any data and server license files you want to retain using LAN, USB flash drive, writable CDs, etc. Keysight recommends floating licenses for logic analyzers with removable disks (such as the 16860-series logic analyzers). If the license server is on the logic analyzer, back up the server license files which are located in the LicenseFiles folder under the license server s installation directory. For example, the default location is: C:\ Program Files\Agilent Technologies\LicenseServer\LicenseFiles\ License files have the extension.lic. You can also use node-locked licenses. However, because the logic analyzer host ID changes with the hard disk drive, you must have separate licenses on each disk. Node-locked license files are located in the License folder under the Keysight Logic and Protocol Analyzer application s installation directory. For example, the default location is: C:\Program Files\Agilent Technologies\Logic Analyzer\License\ WARNING Hazardous voltages exist on the power supply. To avoid electrical shock, disconnect the power from the instrument before performing the following procedures. After disconnecting the power, wait at least six minutes for the capacitors on the power supply board to discharge before servicing the instrument. CAUTION Damage can occur to electronic components if you remove or replace assemblies when the instrument is on or when the power cable is connected. Never attempt to remove or install any assembly with the instrument on or with the power cable connected. 1 Power off the system using one of the methods explained below. 2 Remove the power cord. 14 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 Using the Windows Shutdown On the logic analysis system desktop, click Start > Shut Down or if you are running remote desktop, click Start > Settings > Windows Security > Shut Down. This software power off does the following: Closes all programs that are running. Writes all data to the disk. Turns off the power supply. If the system is unplugged while it is off and then plugged back in, the system will not power on until the power button is pressed. Using a Short Press of the Power Button Pressing the power button on a frame for a short time (less than 2 seconds): Closes all programs that are running. Writes all data to the disk. Turns off the power supply. If the power button is depressed for a short time (less than 2 seconds or so) while another instrument has an open Remote Desktop connection to this instrument, a message on the logic analysis system screen (not on the remote desktop) will pop up asking if you really want to power down. Clicking the 'yes' button results in the above events. Clicking 'no' will prevent the shutdown and not answering the dialog box (neither clicking "Yes" or "No") will have no effect. Further short presses on the power button will have no effect. Using a Long Press of the Power Button Pressing the power button for more than 4 seconds will power the system down abruptly. Use this method only when other methods have not responded: Programs that are running will not be shut down. Any data that has not been written to the disk will be lost. Turns off the power supply. If the system is unplugged while it is off and then plugged back in, the system will not power on until the power button is pressed. If the system does not boot, the hard disk drive will need to be re-imaged. Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 15

2 Installing the Hard Drive Unplugging the Power Cord or Power Loss Step 3. Remove the current hard drive SSD Unplugging power while the instrument is turned on or a power loss is similar to the long press of the power button with one exception: When the system is plugged back in, it will power up and boot into Windows. The 16860 logic analyzer has a removable hard disk drive SSD. It can be removed and replaced without disassembling the instrument. 1 Loosen both the thumb screws that hold the hard disk drive in place. Removable Hard Disk Drive SSD Thumb Screws 16 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 2 Pull the drive tray out to remove the disk drive. Removable Hard Disk Drive SSD pulled out Step 4. Install the new hard drive 1 Slide the new removable hard drive SSD into the drive bay. 2 Gently press the tray all the way in to seat the disk drive connectors. 3 Tighten both the thumb screws that hold the hard disk drive in place. Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 17

2 Installing the Hard Drive 18 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Installing the Hard Drive 2 Step 5. Power on the 16860 logic analyzer Turn on the logic analyzer. Step 6. Perform the first-time set up steps Step 7. Perform the first-time set up procedures If you are using the E5867A replacement hard disk as an additional bootable drive, the replacement disk is pre-configured with the operating system, frame drivers, and logic and protocol analysis application software (just like the original 16860 disk as shipped from the factory). The next step is to perform the first-time set up procedures described in the 16860 -Series Logic Analyzers Installation Guide shipped with the 16860 logic analyzer. Step 8. Restore data The next step is to perform the first-time set up procedures described in the 16860-Series Logic Analyzer Installation Guide shipped with the 16860 logic analyzer. Step 9. Install any additional application software Restore the data and server license files you backed up in Step 1. Back up data for transfer to new hard drive SSD" on page 14. Install any additional application software. Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 19

2 Installing the Hard Drive 20 Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide

Keysight E5867A Removable Hard Drive SSD for 16860-Series Logic Analyzers Installation Guide 21

This information is subject to change without notice. Keysight Technologies 2016 First Edition, August 2016 *E5867-97001* www.keysight.com