utilization of pipettes

Similar documents
Fixed and Adjustable Spacing Electronic Pipettes

CappController Pipette Controller. Operation Manual Version:

Use of Micropipettes

Calibration of Volumetric Glassware

Calibration of Volumetric Glassware

Measurement and Calibration

How To Test A Titrette And Digital Burette

Omega Pipettor. Operating Instructions

Household use only ELECTRIC HOT WATER DISPENSER. User Manual TH W P- 30 THWP L 3.0L RE FIL L

ClikSTAR - Important facts about your new insulin delivery device.

Calibration of Glassware

The Analytical Balance

Surface Tension Measurements Using the Drop Shape Method

Your Personal Pipetting Robot

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

Operating Instructions

DISSOLVED OXYGEN PROBE

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Eppendorf Research plus. Operating manual. Research plus - Operating Manual - en

Pipet-Lite. Multichannel Magnetic Assist Pipette. 8-, 12-, 16- (2x8), 24-channel models

COMMON LABORATORY APPARATUS

Assessment of Accuracy and Precision

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

The Determination of an Equilibrium Constant

Decontamination and Waste Management

Relative Humidity Calibration Kit

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Costco Bakery Employee Training Manual

Archived. Gloves should be changed frequently during the analysis.

Titrette. class A precision. The next generation Digital Burette!

Single Channel Electronic Pipettes MPA. Series

Multipette stream /Xstream Repeater stream /Xstream. Operating manual

Agilent High Sensitivity DNA Kit Guide

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

ph Measurements of Common Substances

Titrette. class A precision. The next generation Digital Burette!

ORGANIC SAMPLE PREPARATION

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

Aseptic Technique. A GMP/GTP Training Module

PP / PE X X X X (X) X PA (X) X

Others ph conductivity measurement module ph and conductivity measurement in 96 deep well plates

SenTix 950 SenTix 980

Guidance on safe use of Autoclaves

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Volumetric Measurement

Laboratory Biosafty In Molecular Biology and its levels

Paper Chromatography: Separation and Identification of Five Metal Cations

Density Determinations

Mitos P-Pump. product datasheet

Gravimetric determination of pipette errors

Factors Affecting Enzyme Activity

FACT SHEET : Using Autoclaves Safely

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

Biological Safety Program

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

Color, True and Apparent

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Appendix J IBC Biohazard Spill Management Plan

Thermo Scientific Finnpipette Finntip. Good Laboratory Pipetting Guide

Color, True and Apparent

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Policies. Prep Room Policies

Phosphorus, Reactive (Orthophosphate)

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY

Care and use guide. Contents. a handy solution made easy. page

HARVESTING AND CRYOPRESERVATION OF HUMAN EMBRYONIC STEM CELLS (hescs)

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Welcome to chapter 10. The following chapter is called Equipment maintenance and monitoring. The author is Ronny Janssens.

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

The volume of a penny will be calculated from its mass and density.


Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

limit to percentage levels, a limited working range translates

Automobile Air Conditioning Primer

How do scientists collect and analyze data?

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Biosafety Level 2 (BSL-2) Safety Guidelines

Seed Respiration. Biology Individual or teams of 2. Grade DESCRIPTION LEARNING OUTCOMES MATERIALS READINESS ACTIVITIES.

6 H2O + 6 CO 2 (g) + energy

Introduction BIOMEDICAL WASTE

INSTRUCTIONS Edition AC

Infectious Waste Management Plan

Accurate Air Flow Measurement in Electronics Cooling

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover

Solubility Product Constants

Hazardous Waste Procedures

Ultrasonic support removal tank

HBV Quantitative Real Time PCR Kit

Dehumidifier D 850E. - Instruction manual version 02

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

MOISTURE (Karl Fischer, Buffered)

Transcription:

utilization of pipettes

contents liquid handling - overview pipetting large volume glass / plastic pipette pipetting pipetting micro volume air cushion pipette forward pipetting / reverse pipetting positive displacement pipette optimal handling tips problematic liquids sources of error summary and outlook

liquid handling Overview dispenser burettes glass / plastic pipettes piston-stroke pipettes electronic pipettes and dispenser automated systems Fotos: Brand und Eigene

pipetting large volume glass / plastic pipettes graduated pipette disposable pipette volumetric pipette accuracy classes

pipetting large volume using pipetting aids never lay down the pipettes with Peleus-ball three times rinsing aspirating vertically adjusting the meniscus vertically wipe of the liquid outside dispensing while holding the container at an angel observe the efflux time

pipetting micro volume Piston-Stroke pipettes Positive displacement pipettes single channel, multi channel (saving time) dispensers electronic pipettes with different techniques: Multipette, Stepper, Tacker, Repeater (saving of time, programmable, reduction of individual mistake ergonomic work)

pipetting micro volume piston stroke pipettes air cushion fixed volumes adjustable volumes 0,1µl to 10 ml different techniques saturate the air cushion autoclavable control button volume setting ring(variable) ejector volume display piston ejector sleeve air cushion spring-loaded tip cone tip Eppendorf user guide No. 19

pipetting micro volume piston stroke pipettes air cuschion Eppendorf user guide no 19

pipetting micro volume piston stroke pipettes air cushion forward and reverse forward pipetting aqueous liquid reverse pipetting viscous liquid volatile liquid source: Eppendorf Webinar 05.04.2016

pipetting micro volume piston stroke pipettes positive displacement tip with integrated piston no air between piston and sample viscous liquid cold or warm volatile liquid no dropping toxic liquid infectious materials no cross-contamination better reproducibility Eppendorf user guide no 19

pipetting micro volume piston stroke pipettes positive displacement Eppendorf user guide no 19

micro volume optimal handling always hang them into a pipette holder only use racked tips - to refill the rack use gloves don t hack - just turn! vertically holding while slowly raising liquid wetting and wiping pay attention, when dipping the tip: 1-10 µl 1-2 mm 10 200 µl 2-3 mm 200 2000µl 3-6 mm 5 10 ml 6-10 mm to remove the used tip, press the remove button cleaning the pipette, when liquid inside (air cushion)

micro volume tips best results by filling 50 % of the volume tips with filters to avoid contamination - and aerosol tip fit on cone tip orifice material - water retention - leachables special tips for displacements pipettes tip changing during calibration yes or no? microscopic pictures of 10 μl tip orifices Fotos Eppendorf application Note No. 354

micro volume problematic liquids liquid air cushion direct displacement volatile viscous dense cold warm foaming infective evaporation in tip and pipette - dropping pre-wetting - reverse pipetting less flow - risk of bubbles - left over in tip slowly reverse pipetting Adjustment equilibrate to room temperature reverse pipetting evaporation into tip and pipette - contamination - corrosion - inaccurate volume use filter tips detergents stick to tip wall contamination risk reverse pipetting contamination risk

pipetting micro volume piston stroke pipettes comparison advantages disadvantages scope of application air cushion pipette cheaper tips cross-contamination dropping aerosol formation aqueous solution viscous liquid (reverse pipetting) positive displacement pipette no cross-contamination better reproducibility no dropping single-use pipette tips cold/warm liquid volatile liquid viscous liquid infective liquid liquid with other density than water

micro volume sources of error Parameter effect /mistake influenceable by realize varying of the interval of pipette ~1,5% eletronic pipette depth of immersion/ hold time ~1,0% hold the pipette according to the recommendation for the volume visual control variation of the temperature of the pipette/air/liquid ~0,3% constant temperature measuring temp variation of relative humidity in the lab ~3,0% prewetting of the pipette tip hygrometer no slough of the last drop on the wall ~3,0% wipe of the last drop on the wall visual control dropping or leaky pipette tip 0,5% - 50% leaky seal, demaged cone, loose untighten tip original tips multiple use of pipette tips ~4,0% use pipette tips one time only straightness of pipette tips ~10,0% use pipette tips one time only,choice of the tips visual control uptaking liquid at an angel,unbalanced force and rhythem 1-5 % vertically holding, regulary force and rhythem visual control different vapor pressure of the pipetted liquid and the adjustment with water 2% adjustment with the pipetted liquid or positive displacement

summary and outlook choosing the correct liquid handling is essential for optimal results problematic liquids need special techniques and tools plastic consumables with high purity mechanical and thermal load capacity, high resistance to chemicals positive displacement system is suitable for most problematic liquids electronic pipettes offer increased reproducibility additional functions saving time agreement relating to unique liquid handling to get more precision

literature Thank you for your attention! Kinnari Pandya et al., J. Pharm. Biomed. Anal., 53, 623-30 Christopf Spätli, Messunsicherheit Volumen mittels Kolbenhuppipetten Mettler Toledo, Good pipetting practice Laborjournal Tip 142 Eppendorf application notes 197, 198, 354, 369 Eppendorf userguide 19, 20, 21, 23, 25, 34 Eppendorf Liquid Handling www.gilson.com www.eppendorf.com www.brand.de.