Township of Schreiber Energy Plan. History

Similar documents
Energy Conservation and Demand Management Plan. From: to:

Township of T Tay Energy Conservation and Demand Management Plan July 1, 2014 to June 30, 2019

City of Peterborough s Corporate Energy Management Plan

County of Hastings. Energy Management Plan. July 1, June 30, 2019

Town of Whitby Corporate Energy Management Plan

Corporate Energy Management Plan

Corporate Carbon Neutral Plan

Energy Management Plan

Corporate Energy Conservation & Demand Management Plan (CECDMP)

Electrical infrastructure serving the city of London CITY OF LONDON Corporate Energy Consumption Report

DATE: June 16, 2014 REPORT NO. PW Chair and Members Committee of the Whole Operations and Administration

Township of Severn Energy Management Plan

COUNTY OF PETERBOROUGH - ENERGY MANAGEMENT PLAN TEMPLATE

Corporate Energy Conservation and Demand Management Plan Engineering Department. Public Works Division

Commitment. Everyone has a role in the wise use of Energy and to showcase the appropriate leadership within Corporation Facilities and Operations.

Energy Benchmarking City of New Westminster: Corporate Facilities

Town of Petawawa Corporate Energy Management Plan

TOWN OF CALEDON. Corporate Energy Management Plan

CANADIAN RENEWABLE ENERGY POLICIES. Matthew H. Brown InterEnergy Solutions 2007

Renewable Choice Energy

Energy Update Report Summary 2014

CITY OF ORILLIA ENERGY MANAGEMENT PLAN

Business Plan: Energy Conservation

Ener ficiency. Corporate Energy and Greenhouse Gas Inventory. Consulting. Squamish-Lillooet Regional District. Prepared For: Prepared by:

Energy Conservation and Demand Management Plan. Township of Wellesley: Developed by Wendy Smith, Administrative Assistant Fire/Recreation

Energy Conservation and Demand Management Plan Municipality of Oliver Paipoonge 2011 to 2018

A Green Sector Overview

Energy Audits Waste Water Treatment Plants

Our Path to Carbon Neutrality. City of Prince George Carbon Neutral Plan

Appendices. Average Electricity Costs Newfoundland and Labrador

Corporate Energy Conservation & Demand Management Plan ( ) - Green Energy Act - Regulation 397/11

Engineering Department. Public Works Division. August 14th, 2014

City of Grand Rapids Approach to Renewable Energy (100% Goal By 2020) Haris Alibasic City of Grand Rapids Office of Energy and Sustainability

COUNTY OF LAMBTON OFFICIAL PLAN UPDATE BACKGROUND REPORT NO.

COMOX VALLEY REGIONAL DISTRICT CORPORATE ENERGY PLAN

Corporate Energy Management Plan

Communicating Your Commitment: Your Guide to Clean Energy Messaging

Corporate Energy and Emissions Management Plan. December 2013

ENERGY CONSERVATION AND DEMAND MANAGEMENT PLAN

City of Timmins Corporate Energy Conservation & Demand Management Plan (CECDMP) 2014 to Prepared by:

Municipality of Port Hope Corporate Climate Action Plan 2010

October 2010 CITY OF SURREY. Corporate Emissions Action Plan

What is Energy? Session 1

Portfolio Manager and Green Power Tracking

KIRKLEES. Visions and Strategies related to Energy and Climate Issues

Wood Pellets for Power and Heat. Gordon Murray, Executive Director

ALLIED PRINTING SERVICES, INC. CORPORATE SUSTAINABILITY AND ENVIRONMENTAL MANAGEMENT PROGRAM REPORT

How To Improve Your Fleet Maintenance

CLEAN GREEN & SUSTAINABLE NS

Achieving Sustainability

IDBI Green Bond Framework

Village of Pemberton. Corporate Energy and Emissions Study. March

ENERGY EFFICIENCY EXPERTS. MCW's. Environmental Record. Green Design REDUCING OUR CLIENTS' ENVIRONMENTAL FOOTPRINT

Regional District of Okanagan Similkameen CORPORATE CLIMATE ACTION PLAN. Prepared by Stantec Consulting Ltd. January 2011 FINAL

Rapid Transit Backgrounder

Commonly asked Question about Green Power, and Kit Carson Renewable Energy Program.

Supplier Guidance Document. Energy and Fuel Use Data from Hertfordshire County Council Outsourced Services

2. Environmental indicators

Regional District of Kootenay Boundary

Peace River Regional District Corporate Energy Plan

TOWN OF. Smithers CORPORATE ENERGY & GHG EMISSIONS PLAN. For inventory years 2004 through 2010

BEST ENERGY MANAGEMENT PRACTICES in 13 North American Municipalities

Corporate Energy Conservation & Demand Management Plan (CECDMP)

Town of Halton Hills Corporate Energy Plan

The City of Calgary 2003 Corporate Greenhouse Gas Emission Inventory

Climate Change Mitigation: a Strategic Approach for Cities

DATE: April 14, 2014 REPORT NO. PW Chair and Members Committee of the Whole Operations and Administration

BROCK UNIVERSITY Report to the Capital Projects and Facilities Committee Information Item

STATE OF FLORIDA OFFICE OF THE GOVERNOR EXECUTIVE ORDER NUMBER

Sustainable Building Policy

REQUEST FOR INFORMATION (RFI) FOR ENERGY EFFICIENCY AND ALTERNATIVE ENERGY SOLUTIONS (RFI ENERGY)

Carbon Footprint of CMC Hospital for 2013

DRAFT. Corporate Energy and Emissions

Earth Hour City Hall, City of London CITY OF LONDON. Culture of Conservation The Next Steps

Energy: renewable sources of energy. Renewable Energy Sources

Policy GRN The City will adopt a Go Green Initiative to implement strategies to reduce greenhouse gas emissions within the City s borders.

How to Earn the LEED Green Power Credit

Business Plan: Fleet Services

PUBLIC REPORT Water Corporation From 1 July 2006 To 30 June 2011

Energy Efficiency Agreement between the Ministry of Trade and Industry and the Municipality of ( )

Climate Commitments and Planning Actions in the City of Helsinki

Rethinking Variable Electric Rate Plans in Texas The case to get out of any fixed rate contract over.16 per kwh

House of Worship Energy Audits

SUSTAINABLE ENERGY ACTION PLAN AND SOLAR PILOT PROJECTS

Clean State Energy Actions 2011 Update. colorado

City Green Fleet Strategic Plan

The importance of energy balances to estimate greenhouse gas emissions

This guidebook provides an overview of the eligibility requirements, available funding, and process for municipalities to participate in TAME+.

The Environmental Commission and the Department of Public Utilities or Engineering Department should lead and be involved with this tool.

TEXAS A&M UNIVERSITY Utilities & Energy Services

Program has been installed. Completed

2009 Energy Policy. Background

PE9.4 Corrected Report

Energy Planning Working Group CORPORATE ENERGY PLAN

GENERAL MOTORS ENERGY MANAGEMENT SYSTEMS

STAFF REPORT Facilities & Fleet

Corporate Energy Management Plan

JACKSON HOLE ENERGY EFFICIENCY ACTION PLAN FALL Page 1 of 9

Threshold Determination: California Case Law

Green Power and Renewable Energy Certificates. BUEC 560 Prof Joseph Doucet

Transcription:

Township of Schreiber Energy Plan To meet the Provincial Regulation 397/11 under the Green Energy Act, the Township of Schreiber has been inputting its energy consumption for use in the development of a document to guide Municipal efforts in improving energy efficiency. 2011 data was submitted in June 2013 and now 2012 data and a five year Energy Conservation & Demand Management (ECDM) Plan have been completed. Within the ECDM Plan will be a summary of Township's annual energy consumption and greenhouse gas emissions for its operations as required by O.Reg..397/11. Also required is a description of previous, current and proposed measures for conserving and otherwise reducing the amount of energy consumed by the public agency s operation and for managing the public agency s demand for energy, including a forecast of the expected results of current and proposed measures. As well, the Municipality has produced this plan to identify our goals for conserving and reducing energy, proposed energy conservation measures including estimated costs and savings, a description of a renewable energy generation facility and the amount of energy produced, as well as how long each proposed measure will be in place for. History The Township of Schreiber has a 130 year history of changing power needs. From heavy dependence on coal in the 1950 s through many changes with hydro-electricity, oil, and propane over the past twenty years the Township has adapted as times have changed. In 1904 a dam was constructed on Cook s Lake and to this day the water treatment plant is fed and all of the sewage flow in town is strictly by gravity. In 2009 the Township had an extensive energy audit on its new municipal office, with energy efficient lighting as the prime saver. The Township has taken advantage of many Hydro One programs to update lighting in all of its buildings.

Intent of the Plan It is the intent of the Municipality that this plan will provide a structured and well defined strategy to focus our efforts towards energy efficiency. It has been written to meet the requirements of regulation 397/11 and will be a working document that will annually be reviewed during the budgeting process to add new projects or make changes if necessary. The plan will be used in cooperation with other plans including Council s Strategic Plan and Schreiber s Asset Management Plan. Schreiber has a population of 1170 as identified by the 2011 Census. This is down significantly from the 1990 s when the population was nearer 1800 people. This population decline has made it difficult to maintain the level of service that was developed for a greatly higher population; however, the Municipality strives to provide as much service for the quality of life of its residents as possible. Municipal Buildings Schreiber Municipal Complex 18,500.00 Square feet Recreation Complex & Arena 39,600.00 Square feet Schreiber Public Library 3,800.00 Square feet Public Works Garage 6,000.00 Square feet J.E. Stokes Medical Centre 5,400.00Square feet Firehall 4,800.00 Square feet Rail Array Museum 1,950.00 Square feet Water Treatment Plant Sewage Treatment Plant Vision for Schreiber Schreiber endeavours to continually reduce its non renewable energy consumption on an annual basis.

Goals The goal of this plan is to achieve a 10% reduction in energy consumption, based on 2011 data, throughout the buildings and lighting of the township by 2020. Objectives Organizational wide understanding of the importance of energy efficiency and a coordinated attack to reduce consumption Renovation of buildings to incorporate energy efficiency practices Striving for LEED certification in construction of new buildings Continuously seeking and evaluating energy efficiency and renewable energy projects for the Municipality 2012 Energy Use By Building See Schedule A Renewable Energy 10kW of installed solar power through the 10kW MicroFIT installations at the Municipal Complex in 2011. Previous Measures Some of the measures completed towards energy efficiency from 2010-2014 include: Replacement of lights in municipal buildings with T8 fluorescent technology Light motion detectors in washrooms at the recreation centre and Municipal Office 10kW solar panel installations on Municipal Office Installation of variable frequency drives motors at the water treatment and sewage treatment plants

Studies Undertaken by the Municipality Energy audit by Hydro One for all municipal buildings. Energy efficient design of Municipal Office Complex Future Measures Together with LAS all new LED streetlights to be installed in 2014. As well the heating/hvac to be reviewed for Municipal Office, Arena/Recreation Complex, water and wastewater plants for better performance. In particular geothermal will be investigated. Private Sector Cooperation A 500kW solar panel installations near our waste water plant with a private sector is being investigated. Municipal Operations Energy efficiency training and awareness for all Municipal staff and signage to promote energy efficiency throughout Municipal Buildings Install variable drive motors where they have not already been replaced as they come to the end of their life cycle or funding opportunities present themselves. Community Capacity Building Work with our business community to provide education on identifying energy savings for the business sector Education for our users groups of Municipal buildings on importance of energy efficiency Advertise energy efficiency ideas to the public through use of the Municipal Facebook page and website Scheduling & Priority of Improvements 2014 Energy efficiency training and awareness for all Municipal staff and user groups to promote energy efficiency

throughout Municipal Buildings Improved signage throughout Municipal buildings about importance of turning things off when not in use Develop an idea system for staff and community groups to bring forward suggestions for improving energy efficiency in Municipal operations. 2015 Ensure payback period analysis on energy efficiency projects is integrated into the annual budgeting process Develop a list of projects for implementation as funding becomes available Evaluate the installation of electronic, real-time monitoring systems at Municipal buildings to better understand the use of electricity in zones and times 2016-2020 This will be developed by Administration and the next Council elected in 2015. Conclusion The Township of Schreiber is placing a high importance on energy efficiency and utilizing renewable energy. By utilizing the ideas of our staff for evaluation by experts in various fields, the Township will work towards reducing its carbon footprint and decreasing what we pay to consume energy.

Schedule A Building Address Size sq/ft Electricity kwh Fuel Oil litres Propane litres GHG Emissions (Kg) Energy Intensity (ekwh/sqft) Energy Intensity (ekwh/mega Litres) Schreiber Municipal Complex 204 Alberta Street 18500 1340785 38289.5 0 233496.7471 94.78165905 0 Recreation Complex & Arena 100 Langworthy Street 39600 815499 36909.3 13553.3 200158.6358 33.04511176 0 Municipal Office (old) 608 Winnipeg Street 1750 116 0 0 11.14064 0.066285714 0 Schreiber Public Library 314 Scotia Street 3800 35394 0 14032.4 25022.94364 35.2762 0 Public Works Garage (new) 101 Stokes Street 6000 51193 0 10022.4 20360.93376 20.27600574 0 Public Works Garage (old) 127 Manitoba Street 2500 67497 0 7008 17281.62775 46.70685178 0 J.E. Stokes Medical Centre 501 Scotia Street 5400 50560 0 5336.1 13078.62712 16.31032306 0 Water Treatment Plant 700 Peary Street 0 315061 0 0 30258.45844 0 820.6850742 Sewage Treatment Plant 95 Winnipeg 0 318918 0 0 30628.88472 0 1226.607692 Old Hydro Garage 804 Peary Street 1600 1659 0 0 159.33036 1.036875 0 Pressure Reducing Valve Chamber 121 Winnipeg 0 4391 0 0 421.71164 0 359.9180328 Firehall 222 Subway Street 4800 57755 0 0 5546.7902 12.03229167 0 Former Ontario Works 304 Walker's Lake Road 1860 142 0 0 13.63768 0.076344086 0 Rail Array Museum 608 Winnipeg Street 1950 7667 0 0 736.33868 3.931794872 0 Old Fire Hall CPR BLK LAND PT RP 55R5874 PART 2 1440 1712 0 0 164.42048 1.188888889 0