SPARE PARTS CATALOGUE

Similar documents
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Waste Oil Handling, Spill Containment & Lighting

123 Industrial Loop Road Paynesville, MN Phone:

ROUGHNECK II Pumpless Drain

Float and Thermostatic Traps Series H, C and X

FLASH TANK ECONOMIZER PRODUCT GUIDE

System Accessories Pricing. Page 0 Effective 7/02

CHEMICAL CLEANING UNIT Product number:

Used Fluid Handling Portable Used-Oil Gravity Drains

Topic : Aviation Fuel Quality Control Regulation, Code or Standard

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Complete Systems & Parts Automatic Oiler & Grease Bank

Stainless Steel Single and Dual Circulation Kits

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

NITROUS TRANSFER PUMP INSTRUCTIONS

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

AIR LINE VALVES AND GAUGES

Master Catalogue I August 2011

Morrison Bros. Co. General Product Specifications

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

PRESSURE REDUCING CONTROL VALVE

D PRO MAC 60 07/72 to 12/76 IPL Page 1 of 19 Accessories

K&T Saw Shop or

VOYAGER 570G. 744A Sprayer Control

In-Line Air Separators

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Solar Collector Series. Product List

Installation Instructions

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

123 Industrial Loop Road Paynesville, MN Phone:

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

MDT5N25 & MTD5N40 SERVICE PARTS

Section 8 Storage Tanks & Equipment

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

PVM Piston Pumps Service Manual

H41 Electrical Stage Aft Air Conditioner Unit Installation

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Solar Hot Water Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Number Wheeler P/N Description Set Rex P/N Notes

SELECTION, APPLICATION AND MAINTENANCE

DR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX LLCH or LUAH)

TOP AND CABINET PARTS

MODEL G300 BRAKE BLEEDER

Fire Pump Plan Review March 2010

Return line filters. Return line filters

Fluid Monitoring and Inventory Management

BERMAD Fire Protection

AUTOMATIC CHANGEOVER MANIFOLD Series 915

PARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SHOT BLAST CABINET MODEL NO: CSB20B

Pressure calibration equipment

Diesel Fuel Filtration

SIMPLAIR PIPING TOOL

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

08 General Purpose Pumps

ALTRA 400 Operator Manual. Planographs and Wiring Diagrams

Direct steam injection humidifiers

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

P a r t s L i s t. P a r t s L i s t. Date: Page: 1

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

1/29/2008 DR50. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45

Self Purging Liquid Trap (SPLT ) User s Manual

Heavy-Duty Lube and Fuel Truck Sales Tool

James M. Pleasants Company

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Spill Containment Manholes

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Agri-Fab OWNERS MANUAL. Model No GALLON "PRO" TOW SPRAYER

Zenith Solar thermal 4.5m pump station Installation manual

Spare Parts List M96A.24SM/B M96A.28SM/B

K&T Saw Shop or

300 Series PA Pump and Cooler Assemblies

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Mono-Block II Installation & Operation Manual

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

400B SERIES DIAPHRAGM PUMP

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

K&T Saw Shop or

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Transcription:

FUELLING SOLUTIONS BY SPARE PARTS CATALOGUE Issue 6

EPOXY LINED CONTAINER These re-usable double-coated epoxy-lined containers have been tested in accordance with the approval procedure defined in ASTM Standard Practice D-4306. They are made specifically for transporting samples of jet fuel for laboratory testing. The cap is epoxy coated and can be safety wire sealed while the new design reduces the amount of fuel and dirt particles trapped in the chine when pouring. Part No TL-2935B-1 TL-2935A-5 TL-2935-2A TL-2935-3 Description 1 gallon can 5 gallon can Shipping box to suit 1 gallon can Shipping box to suit 5 gallon can COLLECTOR TANK These 90 Litre Liquip aviation fuel Collector / Recovery / Slops Tanks are typically used on aviation Refueller and Hydrant Dispenser vehicles. They collect / store fuel from fuel sampling (which is typically manually dumped in through the hatch or from the ALJAC Sampler, if fitted)), from system depressurisation process, from the showflow / air eliminator etc. or from nozzle drain adaptors. The Collector Tank is drained / evacuated by one or more procedures: by an evacuation pump (standard is hydraulically-driven, but can be air-operated diaphragm type (if specified) or manually via the tank s drain valve. These Collector Tanks are based around a standard (base model) 90 litre capacity tank to which several components may be added, creating several variants. As these 90 litre tanks are now a standard, on both Dispensers and Refuellers, typically the only optional additions on the 90 litre versions would be with or without: Nozzle Drain - Carter 61528B Aircraft (A/C) Adaptor. Sight Glass (porthole contents level gauge). Internal Level Sensors / Probes / Float Switches for Low, High or Overfill sensing / warning. Some special builds may have other non-standard components such as external level gauges etc. *CONICAL STRAINER. The CS100ST is a 100 mesh Stainless Steel conical strainer that fits into the tank hatch

COLLECTOR TANK 4 See next page for more parts breakdown of Probe Holder 2 3 1 9 8 7 5 6 Item No Part No Description Qty 1 2000-01-00 Collector Tank - Bare 1 2 2000-04-00 Probe Assembly - High & High/High 2 3 2000-04-01 Probe Assembly - Low Level 1 4 VOH200-5 Probe Holder 3 5 CS100ST Conical Strainer 1 6 2000-03-00 Standard Porthole 1 7 EH231-1A Aluminium Coaming Assembly 1 8 VOH500-32LP Aluminium Emergency Vent Low Pressure 1 9 EH231 Inspection Hatch Assembly 1

MILLIPORE ADAPTOR The chrome-plated dry break connection is available with a 3/8 BSPP and includes a dust cap. Mainly used for fuel sampling, they are also suitable for a variety of applications including pressure checking and gauge testing. For pipework, the extension adaptor length of the unit is suitable for 6 pipework and can be cut down and re-angled for smaller pipe diameters. Part No MSA011V MSF100 AT104 Description Adaptor 3/8 BSPP Mating female half to 3/8 hosetail Adaptor probe assembly MSA011V MSA011V AT104 MSF100 Parts List Item No Part No Description Qty 1 MSA010-2 Millipore Adaptor 1 2 MSA011-1 Millipore Sampling Adaptor Body 1 3 6090 Seal - Cap 1 4 6579 (2) Hammer Drive Screws 2 5 7153 (2) Chain Bead 1 6 7154 Clip - Bead Chain 2 7 MSA010-3 (2) Cap for Millipore Adaptor 1

ALJAC SAMPLER environmentally acceptable, operationally efficient and safe, eliminating any product loss Aljac Closed Circuit Samplers have been designed to permit visual examination and full quality control checking of fuel samples within a closed system. A fuel sample is taken by opening the inlet valve and filling the sampler. Visual examination can be completed and the various checks carried out. When the checks are complete, the drain valve is opened and the sample is released into the slops tank. The Basic Sampler comprises a glass tube, with hinged, vented cover, a cone-down epoxy coated aluminium base, and drain valve with easily operated handle. Fuel enters through a tangential port to promote vortexing which concentrates any impurities. Accessories are available to permit all currently established methods of water detection, together with density and temperature readings. Internally: A holder for either Shell Water Detector (SWD) syringe or the Exxon Hydrokit, for suspended water checking. Externally: A fitting for the SWD syringe at the inlet to the Sampler, adjustable to any angle for convenience. A sample from this point will accurately reflect the condition of the product from which the sample is being taken. Operation A fuel sample is taken by opening the inlet valve and filling the sampler. Visual examination can then be completed and the various checks carried out depending on the accessories fitted. When the checks are complete, the drain valve is opened and the sample released either to a dump tank or back to storage. Features Full visual examination Elimination of spillage Drain to dump/slop tan Accessible for internal cleaning Suits Density measurement Suspended water checking Temperature measurement Inlet connections: 3/8 Outlet connections: 1 ALJAC4

ALJAC SAMPLER M060 Shell Water Detector Capsules (box of 80) M105 5ml Re-suable syringe

ALJAC SAMPLER Item No Part No Description Qty 1 2000-05-01 Bracket Mounting Aljac Assembly 1 2 ALJAC4 Aljac Assembly 1 3 2000-05-04 Post Light Assembly 1 4 8476 Valve Ball 3/8 NPT Apollo 2 5 9049 Tee Tube 3/8 SS 1 6 8622 Washer Flat 16mm ZP 2 7 8648 Fitting Tube Comp. Straight 3/8 NPT x 3/8 T SS 5 8 2000-05-06 Tube 3/8 SS 1 9 2000-05-07 Tube 3/8 SS 1 10 2000-05-08 Tube 3/8 SS 1 11 8620 Washer Flat 12mm ZP 2 12 8618 Washer Spring 12mm ZP 2 13 ZZ0151 Bolt Hex HD M12-1.75P x 30mm ZP 2 14 9036 Fitting Tube Comp. Straight 1 BSP x 3/4 T SS 1 15 2000-05-10 Guard Mesh Frame 1

LIQUIP SALES QLD 730 MacArthur Avenue Central Pinkenba QLD 4008 Tel: +61 7 3633 9100 Fax: +61 7 3260 1732 email: sales@liquip-qld.com.au Website: www.liquip-qld.com.au Leader in refuelling technology and solutions