Maverick HVLP Spray Gun

Similar documents
Stainless Steel Single and Dual Circulation Kits

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Fluid Regulator. Instructions Parts List L LOW PRESSURE

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

BINKS SV100 CONVENTIONAL SUCTION FEED SPRAY GUN

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

RA-20 Rotary Atomizer

Installation Instructions for Alarm Module Kit A043F059

National- Spencer Inc.

BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Spray gun Maintenance and Troubleshooting Guide (JGA)

San josé OWNER S MANUAL

ROUGHNECK II Pumpless Drain

Binks MACH 1PC HVLP SPRAY GUN FOR PLURAL COMPONENT CATALYST INJECTION

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

15GAL STEEL OIL DRAIN WITH 110V PUMP

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Prodigy Manual Powder Spray Gun

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

NITROUS TRANSFER PUMP INSTRUCTIONS

Your safety and the safety of others are very important.

SunMaxx Solar Filling Station Operating Instructions

55-Gallon Dispenser Package

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

OP300S / OP350 2:1 RATIO TRANSFER PUMP

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use R0514

Compressed Gas Cylinder Program

orlando OWNER S MANUAL

MP-4V Heavy Duty Riveter / 39048

MaxiMist Spraymate By Earlex

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

758 Heavy-duty Ratchet Guy Wire Cutter

PAINT SPRAY GUN WASHER

G15/G40 Spray Gun. Instructions - Parts List 3A0149E EN II 2 G

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

IMPORTANT SAFETY NOTICE

BINKS SV100 HVLP GRAVITY FEED SPRAY GUN

Binks Model 7 Spray Gun (6100-XXXX-X)

Installation Instructions S

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Series Hose Reels

PBX Series Quick Fit Connector Bimetallic Steam Traps

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Binks MACH 1, Mach 1V, HVLP Spray Gun

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Airless Spray Coating Technology Including Air-Assisted Airless Spray Technology

AIR CUT OFF KIT INSTALLATION INSTRUCTIONS

MODEL G300 BRAKE BLEEDER

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

CHROME FRONT BRAKE MASTER CYLINDER KIT

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

Hydraulic control unit series

18SP653* EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Handling and Application Information

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

REPAIR AND MAINTENANCE MANUAL

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

RayClic Connection System Installation Instructions

SHOT BLAST CABINET MODEL NO: CSB20B

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

BINKS SG-2 PLUS TM 2 QT. PRESSURE CUPS

Auto Feed Screwdriver

Section 7 Adjustment, Repair and Replacement

This instruction is valid for all ACD pump models shown on page 2

Binks Model 95SL Spray Gun

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

M A N U A L

Installation Instructions

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

G 2500 VH /06

Rexroth Hydraulic Pump A10VO Series User Manual

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Ultra-Lite In-Line Flow Gun

BOWIE PUMPS OPERATION - MAINTENANCE

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Float and Thermostatic Traps Series H, C and X

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

BILLET HEADLAMP SHELL

Machine needle shut-off nozzle type HP

STEERING SYSTEM - POWER

Flat Bottom Long Ram Hydraulic Jack

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

AMX300 DirectConnect Mixing Valve Kits

Dehumidifier Users manual. For Models: DH45S DH65S

HVLP Spray Guns Instruction Manual

Transcription:

Instruction Sheet P/N MSG HVLP A Safety Read and follow these safety instructions. Taskand equipment-specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure all equipment documentation, including these instructions, is accessible to persons operating or servicing equipment. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. Personal Safety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment. While operating manual spray guns, make sure you are grounded. Wear electrically conductive gloves or a grounding strap connected to the gun handle or other true earth ground. Do not wear or carry metallic objects such as jewelry or tools. If you receive even a slight electrical shock, shut down all electrical or electrostatic equipment immediately. Do not restart the equipment until the problem has been identified and corrected. 2005 Nordson Corporation

2 Personal Safety (contd) Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. Make sure the spray area is adequately ventilated. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. High-Pressure Fluids High-pressure fluids, unless they are safely contained, are extremely hazardous. Always relieve fluid pressure before adjusting or servicing high pressure equipment. A jet of high-pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning. If you suffer a fluid injection injury, seek medical care immediately. If possible, provide a copy of the MSDS for the injected fluid to the health care provider. The National Spray Equipment Manufacturers Association has created a wallet card that you should carry when you are operating high-pressure spray equipment. These cards are supplied with your equipment. The following is the text of this card: WARNING: Any injury caused by high pressure liquid can be serious. If you are injured or even suspect an injury: Go to an emergency room immediately. Tell the doctor that you suspect an injection injury. Show him this card Tell him what kind of material you were spraying MEDICAL ALERT AIRLESS SPRAY WOUNDS: NOTE TO PHYSICIAN Injection in the skin is a serious traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Consultation with a plastic surgeon or a reconstructive hand surgeon may be advisable. The seriousness of the wound depends on where the injury is on the body, whether the substance hit something on its way in and deflected causing more damage, and many other variables including skin microflora residing in the paint or gun which are blasted into the wound. If the injected paint contains acrylic latex and titanium dioxide that damage the tissue s resistance to infection, bacterial growth will flourish. The treatment that doctors recommend for an injection injury to the hand includes immediate decompression of the closed vascular compartments of the hand to release the underlying tissue distended by the injected paint, judicious wound debridement, and immediate antibiotic treatment. Fire Safety To avoid a fire or explosion, follow these instructions. Ground all conductive equipment. Use only grounded air and fluid hoses. Check equipment and workpiece grounding devices regularly. Resistance to ground must not exceed one megohm. Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Do not heat materials to temperatures above those recommended by the manufacturer. Make sure heat monitoring and limiting devices are working properly. 2005 Nordson Corporation

Maverick HVLP SPray Gun 3 Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits when working with flammable materials. Shut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shutoff valves, and fire extinguishers are located. If a fire starts in a spray booth, immediately shut off the spray system and exhaust fans. Shut off electrostatic power and ground the charging system before adjusting, cleaning, or repairing electrostatic equipment. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Halogenated Hydrocarbon Solvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components. Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage. Halogenated hydrocarbon solvents contain one or more of the following elements: Element Symbol Prefix Fluorine F Fluoro- Chlorine Cl Chloro- Bromine Br Bromo- Iodine I Iodo- Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: Disconnect and lock out system electrical power. Close hydraulic and pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the system. Disposal Dispose of equipment and materials used in operation and servicing according to local codes. Description The lightweight Maverick HVLP spray gun is ideal for production settings and can be used with a variety of low and high-viscosity coatings on a range of substrates including wood, metal and glass. The gun s lightweight, ergonomic design, easy trigger pull, and single knob fan adjustment maximize operator efficiency and reduce fatigue. Specifications Weight: Air Inlet Size: Fluid Inlet Size: Maximum Air Pressure: 558 grams (19.69 oz) 3 / 8 in. NPS 3 / 8 in. NPS 3 bar (43 psi) Check your material MSDS or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your Nordson representative for information about compatible Nordson components. 2005 Nordson Corporation

4 Installation See Figure 1. Pattern Control Make sure: you have an appropriate fluid tip and air cap for your application. you have air and fluid hoses of the correct length, ID, and materials. Use a grounding-type air hose. WARNING: The air hose must be a grounding-type hose, with continuity between fittings. Without a ground, a static charge could build up in the spray gun, resulting in shocks to the operator or sparking that could cause a fire. Resistance checks, from hose fitting to hose fitting, should be part of your regular maintenance procedures. Fluid Inlet 3 / 8 in. NPS Fluid Control 1. Clean the air hose fittings with a clean, dry cloth. 2. Blow out the air hose then connect the air hose between the 1 / 4 -inch NPS air inlet at the base of the gun handle and the air supply outlet. 3. Regulate the supply air for a maximum pressure of 3.0 bar (43psi) or less at the gun. 4. Connect the fluid hose between the fluid delivery system outlet and the 3 / 8 -inch NPS fluid inlet on the gun extension. 5. Bundle the air and fluid hose(s) together with hook and loop tape, spiral-cut tubing, or similar devices. Make sure the hoses can flex without strain. 6. Supply clean, filtered air to the spray gun. 7. Use the wrench included with the spray gun to tighten the nozzle. Figure 1 Air Control Air Inlet 1 / 4 in. NPS Maverick HVLP spray gun installation 1300568A 2005 Nordson Corporation

Maverick HVLP SPray Gun 5 Operation Make sure: the fluid tip is securely tightened and the air cap is correctly installed and securely held with the retaining ring. all fluid and air connections are secure and leak-free. The fluid hose(s) are grounded. air supply and fluid delivery components are correctly installed. All conductive system components and flammable material containers are securely connected to a true earth ground. the gun handle, operator s station, and spray area are clean and free of debris. NOTE: When starting a new spray system for the first time, remove the air cap and flush the fluid delivery system, hose(s), and spray gun with a solvent compatible with the coating material you will be using. Flushing will remove contaminants from the system. 1. Adjust the air pressure with the air control knob in the handle of the spray gun. 2. Adjust the spray pattern with the pattern control knob on the left side of the spray gun. Daily Maintenance Daily lubrication and cleaning of the spray gun is recommended to maintain the best condition of the spray gun. 1. Shut off the fluid delivery system and air supply. 2. Trigger the gun into the booth or a grounded waste container to relieve any residual pressure. 3. Soak the fluid tip and air cap in a compatible solvent to dissolve any accumulated coatings. Clean them with the brushes included with the gun. 4. Clean the gun extension and handle with a clean cloth dampened with solvent. Do not soak the gun in solvent. 5. Dry the fluid tip, air cap, and gun with low-pressure air from an OSHA-approved blowgun. 6. Apply lubrication and grease where noted in Figure 2. 2005 Nordson Corporation

6 Troubleshooting See Figure 2. This section contains troubleshooting procedures for common gun problems and spray pattern and film-build faults. If you cannot solve your problem with the information given here, contact your Nordson representative for help. Problem Example Possible Cause Corrective Action 1. Gun will not spray 2. Incorrect spray pattern No pressure at spray gun Fluid adjusting screw not properly adjusted Spray gun or fluid supply passages blocked Material build up on air cap Check the air lines and air supply connection. Adjust the fluid adjusting screw. Thoroughly clean the spray gun. Clean the air cap Normal Spray Pattern: Worn or damaged gasket Incorrect material flow or viscosity Replace the green plastic ring (21) Adjust the material flow or viscosity 3. Fluttering Spray Spray gun or fluid supply passages blocked Thoroughly clean the spray gun. 4. Fluid leaking from packing nut 5. Fluid dripping from fluid tip Worn packing or loose packing nut Damaged or loose fluid tip Packing nut loose or the packing is dry Needle is worn Worn or damaged fluid tip or needle Stuck needle packing or needle Replace or tighten the seal nut (22). Replace or tighten the nozzle/fluid tip (3). Tighten or lubricate the seal (23). Replace the needle (12). Replace the nozzle/fluid tip (3) or needle (12). Lubricate the seal (23) or needle (12). Packing gland to tight Adjust the seal (23) Loose fluid control knob Adjust the fluid control knob (11). 2005 Nordson Corporation

Maverick HVLP SPray Gun 7 Repair See Figure 2. Preparations 1. Flush the fluid delivery system, hoses, and spray gun. 2. Turn off the fluid delivery system and air supply. Relieve system fluid and air pressures. Point the gun into the booth and trigger it to relieve any residual pressure. 3. Disconnect the air and fluid hoses from the spray gun. 4. Move the spray gun to a clean, dry, flat surface. Spray Gun Disassembly A complete set of replacement wear parts including seals, springs, and fittings and a spanner wrench are included with your spray gun. Use Figure 2 to disassemble and assemble the spray gun to replace any of the wear parts. NOTE: When assembling the spray gun, apply lubrication and grease where noted in Figure 2. Air Cap, Nozzle, and Needle Replacement The spray gun is shipped standard with a 1.0-mm fluid tip, needle, and air cap combination. Additional size kit combinations are available depending on the application. 1. Remove the fluid control knob (11) and needle spring (10) from the back of the spray gun. 2. Carefully pull the needle (12) back out of the needle housing (9). 3. Remove the retaining ring (2), air cap (1) and nozzle (3) from the front of the spray gun. NOTE: Make sure to replace the complete nozzle, needle, and air cap set. 4. Install the new nozzle and air cap on the front of the spray gun. 5. Carefully slide the new needle through the needle housing and into the spray gun extension until only the small lip of the needle remains outside the needle housing. 6. Insert the spring into the needle housing. 7. Push the fluid control knob onto the spring to mate the threaded parts then screw the knob onto the needle housing. 2005 Nordson Corporation

8 Parts See Figure 2. Part Description Note 1059773 GUN, manual HVLP spray, with 1.0-mm air cap 1059774 REPAIR KIT, manual HVLP spray gun A NOTE A: Kit includes a complete set of replaceable wear items. 1 2 3 4 5 6 7 8 22 23 24 25 9 10 11 21 16 20 19 12 18 17 15 Items in Repair Kit 1059774 13 Apply Lubricant 14 Figure 2 1. Air cap 2. Retaining ring 3. Nozzle/Fluid tip 4. Ring 5. Control knob 6. Screw 7. Spray regulator 8. Gun body 9. Needle housing 10. Needle spring 11. Fluid control knob 12. Needle 13. Air adjust valve 14. Spanner wrench 15. Brush 16. Material sleeve 17. Pin 18. Trigger Apply Non Silicone Grease 19. Washer 20. Air valve assembly 21. Green plastic ring 22. Seal nut 23. Seal 24. Washer 25. Spring 1300566A 2005 Nordson Corporation

Maverick HVLP SPray Gun 9 Air Cap, Nozzle, and Needle Kits See Figure 3. NOTE: The spray gun is shipped standard with a 1.0-mm fluid tip, needle, and air cap combination. Additional size kit combinations are available depending on the application. Make sure to replace the complete fluid tip, needle, and air cap set. Part Description Note Siphon Feed Kits 1059775 AIR CAP KIT, siphon feed, HVLP spray, 1.0 mm 1059776 AIR CAP KIT, siphon feed, HVLP spray, 1.4 mm 1059777 AIR CAP KIT, siphon feed, HVLP spray, 1.7 mm 1059778 AIR CAP KIT, siphon feed, HVLP spray, 2.0 mm 1059779 AIR CAP KIT, siphon feed, HVLP spray, 2.3 mm HVLP Siphon Feed Compliance Kits 1059793 AIR CAP KIT, compliance, siphon feed, HVLP spray, 1.0 mm A 1059794 AIR CAP KIT, compliance, siphon feed, HVLP spray, 1.4 mm A 1059795 AIR CAP KIT, compliance, siphon feed, HVLP spray, 1.7 mm A 1059796 AIR CAP KIT, compliance, siphon feed, HVLP spray, 2.0 mm A 1059797 AIR CAP KIT, compliance, siphon feed, HVLP spray, 2.3 mm A Pressure Feed Kits 1059790 AIR CAP KIT, pressure feed, HVLP spray, 1.4 mm 1059791 AIR CAP KIT, pressure feed, HVLP spray, 1.7 mm 1059792 AIR CAP KIT, pressure feed, HVLP spray, 2.3 mm HVLP Pressure Feed Compliance Kits 1059798 AIR CAP KIT, compliance, pressure feed, HVLP spray, 1.4 mm A 1059800 AIR CAP KIT, compliance, pressure feed, HVLP spray, 1.7 mm A 1059802 AIR CAP KIT, compliance, pressure feed, HVLP spray, 2.3 mm A NOTE A: Compliance kit includes air cap, retaining ring, pressure gage, and tubing. The kit does not include fluid tip or needle. 1300567A Figure 3 Maverick HVLP Air Cap, Nozzle/Fluid Tip, and Needle Kit 2005 Nordson Corporation

10 Issued 1/05 Original copyright date 2005. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. 2005 Nordson Corporation