Outside Air Humidity & Temperature Sensor

Similar documents
Humidity Sensor. Model HU-224/225

Duct Temperature Sensors

Pipe Temperature Sensors

HIH-4000 Series Humidity Sensors

TC-9102 Series Surface Mount Temperature Controllers

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

PRODUCT PROFILE FEATURES

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

Advantium 2 Plus Alarm

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Duct Humidity Transmitter

Part I - Installation

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Industrial Ringdown/Autodialer Telephone SCR Series

MFT Series INTRODUCTION UNPACKING FERRULES

CQM1-SF200/CS1W-SF200

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

User Manual. Humidity-Temperature Chart Recorder. Model RH520

NTC Thermistors, Radial Leaded and Coated

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

HTM2500LF Temperature and Relative Humidity Module

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Model SRMD Setra Remote Monitoring Display

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

el-720 Carbon Dioxide Gas Leak Detector User s Guide

TTL to RS232 Adapter User Guide

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

Operating Manual UWAPS-TINY Series

Machine Safety Switch: SI-LM40 Series Limit Switch Style

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Safety Manual BT50(T) Safety relay / Expansion relay

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Centro-Matic Automatic Lubrication Systems System Controls

Original instructions Tina 3A/Aps Adaptor unit

FEATURES BODY DIA. MAX. Type M AWG 30: [0.254] Type C AWG 28: [0.320] Type T AWG 30: [0.254]

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

MS900AC-B-LS User Information

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

ALARMLINE ANALOGUE Linear Heat Detection System

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

L78MxxAB L78MxxAC. Precision 500 ma regulators. Features. Description

T7079A,B Solid State Remote Temperature Controllers

Threaded Inline Air Heaters

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

How To Use A Cdm250 Digital Multimeter

OME-SERIES DATA ACQUISITION CARDS

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Global Water Instrumentation, Inc.

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTRUCTION MANUAL MODEL PCD-88

Model: DC-A2IO Advanced HVAC Controller

Digital inductive conductivity transmitter

Tina 2A/B Adaptor unit

OPERATING INSTRUCTIONS

Instructions A Amp AC/DC Current Probe

PagePac PAGEPAL V

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Water Leak Detection System

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Triple Expansion Chassis

Park 250 Brushless Outrunner Instructions

SEMICONDUCTOR TECHNICAL DATA

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

RGC-IR Remote Gas Calibrator for IR400

Typical Aluminum GFM Mass Flow Meter

A99B Series Temperature Sensors

DCP Fan Controller. Version 01/2009. The engineer s choice

O C M III. Open Channel Flow Monitor

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Old Company Name in Catalogs and Other Documents

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

Model 43. Precision Low Profile Load Cell DESCRIPTION FEATURES

Operation and Installation Manual

MDC Series

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

HM1500LF Relative Humidity Module

Transcription:

Outside Air Humidity & Temperature Sensor Model HU-227 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation, fog, salt air, pollutants and other contaminants Conformal coated and moisture sealed electronics Rugged steel enclosure and thick-walled aluminum probe rated NEMA-4 (IP-65) to withstand weather extremes NIST traceable ±2% RH or ±3% RH calibration accuracy Two temperature compensated humidity...output versions, 4-20 ma 2-wire or field...selectable 0-5 VDC/0-10 VDC Conforms to EMC and RoHS standards The HU-227 Outside Air Humidity and Temperature Sensor is designed to handle 100% condensing humidity. The electronics are moisture sealed with an acrylic coating, and the sensing element is protected with an eptfe (expanded Teflon) filter media. The unit can be directly mounted inside fresh air hoods of air handlers or underneath roof overhangs of any building. The sensor can also be installed inside the air handler fresh air duct. The Teflon protected cross-linked capacitive humidity sensor is not affected by prolonged exposure to condensing humidity, harsh environments, contaminants, fog or other extreme environmental conditions. The rugged NEMA-4 (IP-65) rated steel enclosure, thick-walled aluminum probe and gasket sealed cover offer a reliable solution for factory-mounted applications. Each HU-227 is calibrated at multiple points in a NIST traceable calibration chamber to meet or exceed ±2% RH or ±3% RH accuracy. Units are temperature compensated over -30 F (-35 C) to +130 F (55 C) temperature range operation with negligible error. HU-227 is available with more than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs for universal compatibility. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The HU-227 incorporates a cross-linked bulk polymer capacitive humidity sensor and precision NTC thermistor, platinum or balco RTD temperature sensor. Both temperature and humidity sensors are immune to most contaminants and at the same time provide a stable, repeatable, accurate humidity and temperature measurement with negligible hysteresis. The sensing elements are not affected by condensation. In fact, the probe may be immersed in distilled water without degrading the calibration accuracy. The HU-227 utilizes sophisticated integrated circuits to provide a high level, fully conditioned, and temperature compensated humidity output. The thermistor temperature sensors are available with more than 16 different industry standard resistance to temperature curves offering compatibility to most if not all control systems. All thermistor sensors offer ±0.2 C interchangeability/accuracy and strictly conform to industry standard R/T curves. The platinum RTD s are available with 100 ohm or 1000 ohm DIN 43760 standards with ±0.12% accuracy at 0 C. All temperature sensors have more than 3.0 mw/ C heat dissipation constant. On VDC output units (humidity only), two additional field selectable options are available; dual outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. By merely moving a switch, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC and no field selection is necessary. The VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohm minimum. In this way, multiple controllers, indicators, or other devices can be paralleled to the output without performance degradation. The ma output units (humidity only) function over a wide unregulated supply voltage range: 12-40 VDC without any effect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by wiring incorrectly. By using sophisticated low dropout voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 250 ohms. At 40 VDC, the unit is capable of handling up to a 1500 ohm load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance. The humidity sensor is protected by an eptfe (expanded Teflon) filter media that incorporates a proprietary process of expanding or stretching an ultra thin Teflon sheet during the manufacturing process to create less than 1.0 micron (0.000039 inch) pores or holes. The hydrophobic and oleophobic characteristics of Teflon force moisture, condensation and other contaminants to form a bubble larger than the pore size, and the surface tension of the Teflon stops the water or other contaminants from passing through the filter media, thereby protecting the sensing element. However, air with absorbed moisture can easily penetrate the filter media. The PCB electronics are coated and sealed with an acrylic conformal coating to protect against moisture, condensation and contaminants. The HU-227 incorporates a rugged NEMA-4 (IP-65) fully gasketed, dust proof and splash proof enclosure. The enclosure has an external mounting bracket to facilitate field installation. A ½" (.875"/22.25 mm diameter) knock-out for conduit connection is also provided. A liquid tight cable connector is supplied if the unit is not being hard wired. Once installed, the enclosure maintains its environmental rating and protects the electronics and the sensing element from condensation, corrosive contaminants and other environmental pollutants. The enclosure also has additional features for ease of installation including unpluggable terminal block and easily accessible zero and span trimmers. 2

HUMIDITY TRANSDUCER SPECIFICATIONS: Accuracy*: ±2% / ±3% RH Range: 0-100% RH Hysteresis: ±1% Supply Voltage: 12-40 VDC 12-35 VAC (VDC output units only) Compensated Temp Range: -30 F to 130 F Load Impedance: 1.5K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) * Includes non-linearity and non-repeatability PLATINUM RTD SENSOR SPECIFICATIONS: Accuracy: 0.12% at 0 C Resistance: 100 or 1,000 ohm at 0 C Standard: DIN 43760 Heat Dissipation: 3.0 mw/ C R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -30 F to 130 F THERMISTOR SENSOR SPECIFICATIONS: Interchangeability: ±0.2 C Heat Dissipation: 3.0 mw/ C R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -30 F to 130 F GENERAL SPECIFICATIONS: Environmental: 10-100%RH Enclosure: 18 Ga C.R. Steel NEMA 4 (IP-65) Finish: Baked on enamel - PMS2GR88B Termination: Unpluggable screw terminal block Wire Size: 12 Ga maximum Weight: 1.0 lbs. (.45 kg) CONFORMANCE & TESTING: RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 ORDERING INFORMATION: HU-227- Accuracy Output Temperature Sensor ±2% ±3% ma (4-20 ma 2-wire) VDC (0-5 VDC/0-10 VDC field selectable) Example: HU-227-2-mA-3: Outside Air Humidity and Temp Sensor, ±2%RH accuracy with 4-20 ma output and 1,000 ohm Platinum RTD. For Resistance vs. Temperature Tables, please refer to TI.700-11. 1 100 ohm Platinum RTD 2 1,000 ohm Nickel RTD (5000 PPM) 3 1,000 ohm Platinum RTD 4 1,000 ohm Nickel RTD (6000 PPM) 5 1,000 ohm Balco RTD 7 10,000 ohm NTC thermistor (Type III) 8 10,000 ohm NTC thermistor (Carel) 10 3,000 ohm NTC thermistor 12 10,000 ohm NTC thermistor (Type II) 13 5,000 ohm NTC thermistor 14 1,035 ohm Silicon PTC 15 100,000 ohm NTC thermistor 16 10,000 ohm NTC thermistor (Eliwell) 17 20,000 ohm NTC thermistor 18 2,252 ohm NTC thermistor 21 1,800 ohm NTC thermistor CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media. 3

4.50" (115.0) 2.00" (50.0) 2.15" (55.0) 5.00" (127.0) 1.00" (25.0) 3.20" (81.0) 2.65" (67.3) 4.00" (102.0) 2.25" (57.0) 0.50" (13.0) (mm) DN227.4 Registered trademark MAMAC SYSTEMS, Inc. 4

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876