EGH 681: SAUTER viasens681 humidity and temperature sensor

Similar documents
T0118 T2118 T3118. Instruction Manual

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Instruction Manual. T3111 T3111L T3111P T3111Ex

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Digital input modules

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

TX OPEN RS232/485 module

Product and Application Description

Drayton Digistat +2RF/+3RF

Duct Humidity Transmitter

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

HERZ-Thermal Actuators

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Material test chamber with mechanical convection

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

ACS-30-EU-EMDR-10-MOD

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Incubator with mechanical convection

Operating Instructions. Room temperature controller

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

Product and functional description

Flush-mount room temperature sensor AQR2531ANW.

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PCS0100en Persy Control Services B.V. Netherlands

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Multifunction devices

RRV934. Multi-controller. Synco living

Heating oven with mechanical convection

Room Temperature Sensors

Heating oven with mechanical control

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Hand-held thermometer Model CTH7000

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

GREISINGER electronic GmbH

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

is then retained absolutely without interruption.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Rousseau 10. User Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Smile. The All-In-One Heating Controller

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

How To Read A Pipe From A Sensor

Danfoss Link Mobile Phone Butler

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Pressure Dew Point Probe / Application Information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

HMI display Installation Guide

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

IN-OUT Thermometer with Cable Free Sensor and Clock

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Y7230A CO 2 Alarm System

User's Guide. Integrating Sound Level Datalogger. Model Introduction

How To Use A Ds340 (Dsp)

VAV compact controller KNX / PL-Link

DS 600. A contact free flux gate based current measurement sensor 600A rms

CompactLogix Power Supplies Specifications

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Digital Pressure Measuring Instrument MDR480

DUST EMISSION MONITORING SYSTEM

Adjustment functions for both span and shift have been incorporated

Subminiature Load Cell Model 8417

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Color Mark Sensor with Red or Green LED E3S-VS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

COMBIMASS. Technical Data COMBIMASS eco-bio +

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ATL Fuel Level Sender Probes

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Combi switchbox with integrated 3/2 way pilot valve

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Technical data sheet TDS0070

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Features. Picture. Specifications

Antenna Splitter ASA 1. Instruction manual

SINEAX U553 Transducer for AC Voltage

Capteur température et humidité pour HVAC

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

AXIS T81B22 DC 30W Midspan

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Transcription:

Output signal 2) Analogue outputs 2 0...10 V Product data sheet 34.001 EGH 681: SAUTER viasens681 humidity and temperature sensor How energy efficiency is improved Precise measuring of relative humidity and temperature for energy-efficient room climate control Features Sensor for measuring the relative humidity and the temperature in rooms Sensor for controlling the room climate in combination with room automation systems Measurement of the room temperature and the relative humidity Fast response time and high precision Calculation of indirect variables such as absolute humidity, enthalpy, dew point Quick, easy overview of the room climate through a multi-coloured LED Wide-ranging parameterisation with the CASE Sensors software The power supply and the analogue outputs are electrically isolated Room sensor in a wide range of designs and colours Device insert fits into frame with 55 x 55 mm aperture Technical data Power supply Power supply (SELV) 1) 24 V~, ± 20%, 24 V=, +20%/-15% Power consumption 0.3 W Relative humidity 0...100% rh Temperature 0...50 C Load current 0...2 ma (per output) Parameters Relative humidity Measuring range 10...95% rh Accuracy (at 23 C) Reproducibility Resolution ± 2.0% rh (40...60% rh) ± 3.5% rh (<40% rh/ >60% rh) ± 1% rh 0.2% rh Time constant < 15 s (in air 0.1 m/s, t 63 ) Warming-up time 3) 30 min. Temperature Measuring range 0-50 C Accuracy (at 23 C) ± 0.4 C Reproducibility ± 0.15 C Resolution 0.05 C Time constant < 10 min. (in air 0.1 m/s, t 63 ) Calculated variables 4) Absolute humidity (water vapour content) Range Accuracy (at 23 C, 55 %rh) 0...50 g/kg < 1 g/kg Enthalpy Range 0...100 kj/kg Accuracy (at 23 C, 55 %rh) < 3 kj/kg Dew point Range -5...30 C Accuracy (at 23 C, 55 %rh) < 1.5 C 1) SELV: Safety extra low voltage 2) The two analogue outputs can each be assigned a measured or calculated value with CASE sensors. The factory setting is relative humidity and temperature. 3) The precision of the sensor is guaranteed after a warm-up period of approx. 30 minutes. During this period, the LED flashes green. 4) The calculated variables are dependent on the temperature and the humidity (see also the diagrams in the Calculated variables section). The results are calculated based on a standard air pressure of 1013 mbar. The device is not pressure-compensated. Right of amendment reserved 2015 Fr. Sauter AG 2.1 1/6

Ambient conditions Operation Humidity (non-condensing) 10...95% rh Temperature 0...50 C Storage and transport Humidity (non-condensing) 10...95% rh Temperature -20-70 C LED indicator LED indicator LED function Factory setting Three colours green, yellow, red Display of relative humidity or temperature or a combination of both Combination of relative humidity and temperature (according to EN 15251) Construction Dimensions W x H x D 59.7 59.7 53 mm (with terminal) Housing Pure white (RAL 9010) Plastic insert Silver (similar to Pantone 877 C) Connection terminals Fitting Cable inlet Weight Pluggable screw terminal for conductor cross-section of max. 1.5 mm 2 Recessed Surface-mounted (with accessories) From behind 58 g Standards and directives Type of protection 5) IP30 (EN 60730-1) Protection class III (EN 60730-1) Environment class 3K3 (IEC 60721) CE conformity as per EMC directive 2004/108/EC EN 60730-1 (for residential premises) Overview of types Type Description EGH681SF233 viasens 681, humidity/temperature room sensor 24V; 0...10V Accessories Type Description 0940240*** For frames, mounting plates and adaptors for third-party frames and surface mounting: see product data sheet PDS 94.055 P100011363 SAUTER film without pictogram for the variable colour: silver (similar to Pantone 877 C) 0300360001 USB connection set Additional information Fitting instructions Declaration on materials and the environment P100011918 D100171376 Manual for CASE Sensors 7010081001 Description of operation The sensor allows the exact measurement of relative humidity and temperature in the room for the energy-efficient monitoring and controlling of the room climate. In addition the sensor can calculate absolute humidity, enthalpy and the dew point. The modern design combines high measuring reliability and elegance. Frames and adaptors are available as accessories for multiple fitting options and provide an optimal solution for every application. Every sensor in the family of products can be identified easily by the pictogram on the front of the device. The pictogram provides the user with intuitive information about the measured variable. 5) when installed 2/6 2.1 Right of amendment reserved 2015 Fr. Sauter AG

T 19 21 25.5 27 C rf 20 30 50 70 % The three-coloured LED indicator enables the user to visualise the temperature and humidity at a glance at any time. The parameters of the LED indicator are set according to EN15251 ex works. CASE Sensors can be used to parameterise these settings as well as a large variety of functionalities specific to the customer. Comfort zone (green area) Fitting The viasens is suitable for various fitting methods. Product data sheet PDS 94.055 shows the fitting options and the accessory material required. For surface mounting, boxes with a minimum depth of 35 mm must be used (for example, the LS990 series from JUNG). For further information, see the fitting instructions. Incorrect fitting can result in incorrect measuring results. Therefore, always observe the mounting instructions. The place of installation must also be chosen carefully to ensure the reliable measurement of the room temperature and the room humidity. Cold outer walls and fitting above heat sources (radiators, for example) and right next to doors with draughts must be avoided, as well as direct sunlight. Furnishings, such as curtains, cabinets or shelves, can hinder the flow of room air to the sensor and thereby cause discrepancies in the measurements. Heating pipes inside the walls can also affect the temperature measurement. With recessed mounting, the installation pipes must be sealed: otherwise incorrect air circulation can cause errors in the measurement. The highest degree of measuring accuracy is attained when mounted in an individual frame. Right of amendment reserved 2015 Fr. Sauter AG 2.1 3/6

Electrical connection The viasens is connected to the electricity supply by means of a pluggable screw terminal. This is suitable for conductor cross-sections (braided or solid) up to 1.5 mm 2. We recommend using a conductor cross-section up to 0.75 mm 2. When you are laying the cables, note that electrical interference can affect the measurements. These effects increase the longer the cable is and the smaller the conductor cross-section. In high-interference environments, we recommend using shielded cables. CASE Sensors a powerful software tool for configuring the sensor The sensor can be used immediately after it is delivered. The customer can use CASE Sensors to parameterise the sensor, providing real added value. CASE Sensors enables the user to work with all the intelligent options of the sensor. The software allows the following specific parameters to be set: Description of the measuring point Function of the LED indicator: Monitoring indicator for relative humidity Monitoring indicator for temperature Monitoring indicator for relative humidity and temperature Inactive Setting the limit values for the LED indicator (see example) Scaling the output signal: Limiting the measuring range Limiting the output signal Switching off the analogue outputs Activating calculated variables Example: Setting the temperature limit values of the LED indicator To use the sensor functions, you require the SAUTER CASE Sensors software and a USB connection set (see accessories). The current version of the software can be downloaded from the website www.sauter-controls.com. After parameterising the sensor, the communications interface must be disconnected at the sensor. Continuous operation with the interface is not permitted. Notes for users Under normal operating conditions, the devices are subject to an extremely slow rate of deterioration. Humidity sensors are subject to increased deterioration if they are used in very contaminated air or aggressive gases. The factors affecting the device depend on the concentration of the aggressive media and can increase the drift of the sensor. If the sensor is used in very contaminated air, the warranty does not cover the premature replacement of the complete sensor. Manufacturer test certificates and maintenance The test certificates enable the measuring accuracy of every sensor to be quantified. The test certificate is valid for the entire device. The user can enter the corresponding measuring results of the sensor as offset values in a higher-level control device (e.g. SAUTER EY-AS 525 automation station). We recommend the following calibration intervals: Under normal conditions, every 2 years. In contaminated air (for example, with cleaning or disinfecting agents), every year. 4/6 2.1 Right of amendment reserved 2015 Fr. Sauter AG

SAUTER provides manufacturer test certificates according to DIN 55350-18 (EN 10204) under the following test conditions: Relative humidity (at 23 C): 30% rh, 55% rh, 70% rh Temperature: 4 C, 20 C, 36 C The sensors can be delivered ex works with the corresponding manufacturer test certificates. For more information, please contact your personal SAUTER representative. Calculated variables The measurement of the relative humidity and the temperature allows a range of variables to be calculated. The calculated variables can be activated using CASE Sensors and assigned to an output signal. The operation of the LED indicator cannot be assigned to the calculated variables. The LED indicator is reserved for the temperature and/or the relative humidity. Absolute humidity (water vapour content) The absolute humidity is the water vapour contained in a kilogram of air (g/kg). Range: 0 50 g/kg Accuracy: < 1 g/kg (at 23 C and 55% rh) Absolute humidity accuracy range Enthalpy The enthalpy (or heat content) is the energy (quantity of heat) contained in the air. It is expressed as kj/kg. A temperature of 0 C is used as the reference variable. Range: 0-100 kj/kg Accuracy: < 3 kj/kg (at 23 C, 55% rh) Enthalpy accuracy range Dew point The dew point or the dew point temperature is the temperature at which the water vapour contained in the air reaches saturation point, condenses and changes to the liquid state. Range: -5-30 C Accuracy: < 1.5 C (at 23 C, 55% rh) Right of amendment reserved 2015 Fr. Sauter AG 2.1 5/6

Dew point temperature accuracy range The viasens681 cannot be used as a dew-point monitor. A condensation protection application is implemented with a separate clamp-on sensor, e.g. SAUTER EGH 102. Dimension drawing 31 53 M11515 Connection diagram EN 61558-2-6 LS/L+ MM 0...10 V 0 V 0...10 V The power supply (pins 1 and 2) and the analogue outputs (pins 5 and 7) are electrically isolated from each other. A10789a Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 2.1 Right of amendment reserved 2015 Fr. Sauter AG