Aesthetics Improvement Manual

Similar documents
Considering UNDERGROUND. tampaelectric.com

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information

COMMERCIAL CONDUIT RULES AND REGULATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Development Services Department City of San Antonio. Permits & Licenses. Development Services Manager. Deputy Historic Preservation Officer

Gas Meter Clearances and Service Installation Requirements

Questions Regarding Proposed Utility Undergrounding in Kensington

B. Improve the appearance and character of areas surrounding new development.

Electrical Service Requirements (ESR)

Policy and Guidelines for Electric Service

Application for. Commercial New Service

ELECTRIC SERVICE GUIDELINES (For Indiana)

Gas Meter Clearances and Service Installation Requirements

June July 18, of 7

Hyperlinks are Inactive

Q. Why does OG&E clear vegetation away from power lines? A. Trees that grow into power lines can cause problems in multiple ways:

DESIGN GUIDELINES FOR UTILITY METERS D.C. HISTORIC PRESERVATION REVIEW BOARD

Electric Service Guide. Residential Subdivision

The Florida Club Property Owners Association. Architectural Standards Guidelines

SECTION SITE PREPARATION

Electric Service Rules

Vegetation Management. for Distribution Lines

Toronto's New Soil and Tree-based Standards for Boulevards

DESIGNING YOUR LANDSCAPE

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Annual Maintenance Review Report

ELECTRICAL CONTRACTORS HANDBOOK (ECH)

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering

Applying For New or Revised Electric Service

agrees to replace at no charge any tree that dies and subsequent inspection shows that the wire basket was not properly removed.

Electric Service Conversion Overhead-to-Underground. Minnesota

Underground Service Requirements and Instructions

Electric Service Guide for Commercial Construction

Chapter O-R-D OFFICE RESEARCH PARK AND DEVELOPMENT ZONE Purpose of provisions. Title 19 ZONING Purpose of provisions.

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

DALLAS COUNTY, IOWA CHAPTER 48 SMALL WIND ENERGY CONVERSION SYSTEMS ORDINANCE FOR THE UNINCOPORATED AREA OF DALLAS COUNTY, IOWA

KUB Tree Pruning: A Customer Guide

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Architectural Review

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

It was my assignment to physically inspect the 8 trees on site near the proposed construction,

EL LAGO BUILDING DEPARTMENT PERMIT ISSUANCE PROCEDURES As of February 20, 2013

Waterleaf ARB Application

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Capital Village Community Architecture and Landscape Guidelines

Report power outage after hours: N E. Ashton, ID ec.com. Ashton, Idaho Headquarters Building

Architectural Design Standards Example Guide DESIGN STANDARDS EXAMPLE GUIDE

NAHB PRODUCT DEFINITION

How To Preserve Trees

CHAPTER 13 NATURAL RESOURCES ARTICLE III. TREES

DESCRIPTION OF WORK:

D3 April 8, 2015 Public Hearing

Avoiding Tree & Utility Conflicts

SPECIFICATIONS FOR ELECTRIC SERVICE GARLAND POWER & LIGHT

Arizona Landscape Contractors Association Represents Nearly 400 Companies Approximately 30,000 employees $700 Million in Arizona Revenue

Does your new building

CENTRAL BUSINESS DISTRICT STREETSCAPE AND IMPROVEMENT GUIDELINES

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

New Home Construction Packet

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

Parrish Park Homeowners Association. Architecture Committee Guidelines for Property & Home Improvements. June 2002

Customer Guide for Electric Service Ohio

MOBILE HOME SERVICE REQUIREMENTS GAS

Chapter 6: Company Specific Items. Sheet No Page 3 of 5. CenterPoint Energy Houston Electric, LLC Applicable: Entire Service Area CNP 8031

Electrical Service Guidelines

River Friendly Landscape Program Frequently Asked Questions (FAQs) February 2016

Landscaping around electrical equipment

29 Broadway- 14 th Fl Tel: New York NY Fax: Due Diligence Report. New York, New York

4/1/2016 Revision of the CNP Service Standards Book (Effective Date )

Call the Experts at REA Energy Services for all of Your Electrical and HVAC Needs.

Changes in the 10/2/2013 Revision of the CNP Service Standards Book

Information and Requirements for Electric Service. Chapters 1, 2, 4, 6 and Appendix

The City of Basehor, Kansas

Windbrooke Townhome Association, Inc. Maintenance & Service Responsibility Chart

Chapter 29 VEGETATION* ARTICLE I. IN GENERAL

SHALLOW UTILITIES JOINT PROVISIONING GUIDELINES SCOPE

CHAPTER 23 Wireless Communication Facilities

City of Alcoa Electric Department Tree Trimming Policy

SECTION 4Aggegate Subbase

Vegetation Management Frequently Asked Questions

CODE ENFORCEMENT - FAQ STREETS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Residential Building Permits Information

IRRIGATION PUMPING Table of Contents - Section 900

Merrimac Municipal Light Department. Residential Developments Policy

FORENSIC INVESTIGATION QUESTIONNAIRE

Engineers Edge, LLC PDH & Professional Training

NATIONAL FLOOD INSURANCE PROGRAM (NFIP) SUBSTANTIAL DAMAGE/ SUBSTANTIAL IMPROVEMENT (50% RULE)

The Importance of Garbage Clearing and vegetation

Charter Township of Shelby Harry Reese Building Director

new construction departments...

Crime Prevention through Environmental Design (CPTED) - Checklist

Underground Commercial Electric Service

How To Protect A Swimming Pool

Transcription:

Aboveground Equipment Aesthetics Improvement Manual May 2011

1. Introduction, Purpose and Getting Help Table of Contents 2. Examples of Typical Aboveground Installations and Clearance 2.1 Examples of Single-Phase (Residential) Pad Mounted Transformer Installations... 1 2.2 Clearances for Single-Phase (Residential) Pad Mounted Transformer, PME 1 Cabinet or PME-2 Switch... 2 2.3 Example of Three-Phase (Commercial Building or Service) Pad Mounted Transformer Installation on a Pad... 3 2.4 Clearances for Three-Phase (Commercial Building or Service) Pad Mounted Transformer on Concrete Pad... 4 2.5 Example of Three-Phase (Commercial Building or Service) Pad Mounted Transformer Installation on a Slab Box... 5 2.6 Clearances for Three Phase (Commercial Building or Service) Pad Mounted Transformer on Slab Box... 6 2.7 Example of Load Break Fuse Cabinet (LBFC) Installation... 7 2.8 Clearances for LBFC... 8 2.9 Example of Capacitor Cabinet Installation... 9 2.10 Clearances for Capacitor Cabinet... 10 2.11 Example of Pad Mounted Gas Switch Installation... 11 2.12 Clearances for Pad Mounted Gas Switch... 12 2.13 Examples of PME 3, PME 4 or PME 5 Installations... 13 2.14 Clearances for PME 3 (See Note), PME 4 or PME 5... 14 2.15 Examples of PME 6 through PME 12 Installations... 15 2.16 Clearances for PME 6 through PME 12 Style Cabinets... 16 2.17 Examples of Primary Metering Cabinet Installations... 17 2.18 Clearances for Primary Metering Cabinet... 18 2.19 Examples of Pad Mounted Equipment with Protective Barriers... 19 2.20 Clearances for Pad-Mounted Equipment with Protective Barriers... 20 2.21 Examples of Re Painted Pad Mounted Equipment... 21 2.22 Examples of Re-Painted Pad-Mounted Equipment... 22 2.23 Examples of Re-Painted Pad-Mounted Equipment... 23 3. Typical Pad-mounted Equipment Locations on Private Property, Franchise Areas and Commercial Areas 3.1 Typical Pad-Mounted Equipment Location on Private Property... 24 3.2 Typical Pad-Mounted Equipment Location in Franchise Areas... 25 i

4. Typical Pad-Mounted Equipment Location in Commercial Areas Equipment 4.1 Typical Pad-Mounted Equipment Location in Commercial Areas... 26 5. Policy for Graffiti Abatement and Re Painting of Edison TDBU Equipment By Third Parties 5.1 Policy for Graffiti Abatement and Re Painting of Edison TDBU Equipment By Third Parties... 27 6. Policy for Digital Wrap of SCE Equipment By Third Parties 6.1 Policy for Digital Wrap of SCE Equipment By Third Parties... 28 7. Landscaping Around Edison Pad-Mounted Equipment 7.1 Landscaping Around Edison Pad-Mounted Equipment... 29 ii

Introduction Welcome to the Aesthetics Improvement Manual (AIM), a new publication illustrating typical installations of Edison s aboveground pad-mounted equipment, space requirements for this equipment and approved aesthetic improvement options. It serves only as a quick reference guide, highlighting existing information found elsewhere in SCE publications. This manual is not intended to replace or supersede existing SCE construction or design manuals. Purpose The purpose of this manual is to provide Edison s customers including civil and architectural engineers, city planners, developers, utility consultants, and general customers with information on the requirements and options available for designing and installing pad-mounted equipment to achieve best results on new projects. Edison s own planners, project managers, Local Governmental Affairs representatives, and others will also benefit from this manual. The primary intent of AIM is as follows: 1. Aid in the understanding of the Edison distribution system structure requirements. 2. Plan appropriately for operating and clearance space requirements. 3. Illustrate various approved options for aesthetic improvement of equipment. In creating AIM, SCE s objective is to facilitate a proactive discussion during the entire design and planning review process throughout our service territory. The manual is a living document and feedback is both welcomed and encouraged. The manual includes references to applicable Electrical Service Requirements (ESR) and Underground Structures (UGS) standards. For access to current editions of the ESR Manual or UGS Manual contact your SCE representative. External customers who need more information on the Aboveground Equipment structure can go to the following web address: http://www.sce.com/aboutsce/regulatory/distributionmanuals/. Note: AIM does not contain all SCE Aboveground Equipment, nor does it address unique field circumstances which can and should be considered on a case-by-case basis. Getting Help If you have any comments, questions, or suggestions concerning this manual, please contact one of the following individuals: Alaira Bilek at (714) 895-0156 or Alaira.Bilek@sce.com Ruben V. Rodriguez at (714) 895-0733 or Ruben.V.Rodriguez@sce.com iii

Examples of Single-Phase (Residential) Pad Mounted Transformer Installations 1

Clearances for Single-Phase (Residential) Pad Mounted Transformer, PME 1 Cabinet or PME-2 Switch Distribution Standard References: ESR-4, UGS SS 504 & UGS SS 506 2

Example of Three-Phase (Commercial Building or Service) Pad Mounted Transformer Installation on a Pad 3

Clearances for Three-Phase (Commercial Building or Service) Pad Mounted Transformer on Concrete Pad 5' TYP. DOOR SIDE 14' EASEMENT 8' 8' DOOR SIDE 6' 17' EASEMENT Distribution Standard References: ESR-4, UGS SS 504, UGS SS 530 & UGS SS 535 4

Example of Three-Phase (Commercial Building or Service) Pad Mounted Transformer Installation on a Slab Box 5

Clearances for Three Phase (Commercial Building or Service) Pad Mounted Transformer on Slab Box Distribution Standard References: ESR-4, UGS SS 504, UGS SS 530 & UGS SS 535 6

Example of Load Break Fuse Cabinet (LBFC) Installation 7

Clearances for LBFC Distribution Standard References: UGS SS 506 8

Example of Capacitor Cabinet Installation 9

Clearances for Capacitor Cabinet Distribution Standard References: UGS SS 520 10

Example of Pad Mounted Gas Switch Installation 11

Clearances for Pad Mounted Gas Switch Distribution Standard References: UGS SS 536 & UGS SS 537 12

Examples of PME 3, PME 4 or PME 5 Installations 13

Clearances for PME 3 (See Note), PME 4 or PME 5 Note: 4-Foot clearance is required from edge of pad for automation. Distribution Standard References: UGS SS 540 & UGS SS 591 14

Examples of PME 6 through PME 12 Installations 15

Clearances for PME 6 through PME 12 Style Cabinets Distribution Standard References: UGS SS 587 & UGS SS 590 16

Examples of Primary Metering Cabinet Installations 17

Clearances for Primary Metering Cabinet Distribution Standard References: UGS SS 590 18

Examples of Pad Mounted Equipment with Protective Barriers 19

Clearances for Pad-Mounted Equipment with Protective Barriers Notes: 1. On door side of equipment, 3-foot clearance is required between the protective barriers and edge of pad. 2. Protective barriers are required when clearance between the equipment pad and curb is less than 5 feet. Distribution Standard References: UGS MS 830 20

Examples of Re Painted Pad Mounted Equipment 21

Examples of Re-Painted Pad-Mounted Equipment 22

Examples of Re-Painted Pad-Mounted Equipment 23

Typical Pad-Mounted Equipment Location on Private Property Sidewalk Transformer Trench Driveway Driveway Future Home 1 Future Home 2 P/L 24

Typical Pad-Mounted Equipment Location in Franchise Areas Transformer Trench Sidewalk Driveway Driveway Future Home 1 Future Home 2 P/L 25

Typical Pad-Mounted Equipment Location in Commercial Areas 26

Policy for Graffiti Abatement and Re Painting of Edison TDBU Equipment By Third Parties Edison has recently secured the services of a contractor to remove graffiti from padmounted transformers, capacitor enclosures and switch cabinets. This service may be performed on equipment franchise areas or on private property. Edison may also grant authorization to change the color of pad-mounted transformers, capacitor enclosures and switch cabinets to third parties, such as government agencies, customers, service clubs and similar organizations. The re-painting may be performed on equipment in franchise areas or on private property. The re-painting activity shall conform to the Conditions for Painting Edison TDBU Equipment by Third Parties, (form available in your local SCE Planning Office). To ensure compliance with this policy and the Conditions for Painting Edison TDBU Equipment by Third Parties, the responsible design AOR representative shall conduct an orientation meeting with each requesting party, consisting of a review of SCE s policy and conditions. Third parties granted authorization to change the color of Edison TDBU equipment shall perform all the work, and absorb all costs for such activity. For details and specific requirements regarding the graffiti abatement policy and repainting of pad-mounted equipment policy, please contact the local SCE Planning Office in your area. 27

Policy for Digital Wrap of SCE Equipment By Third Parties Edison has provided commercial/residential developers and individual Edison customers with an opportunity to enhance the looks of Edison s pad-mounted equipment without compromising operational integrity. Digital Wrap can be installed around padmount equipment to closely match the surrounding landscape. Digital Wrap activity shall conform to the Conditions for Digital Wrap of SCE Equipment by Third Parties, (form available in your local SCE Planning Office). To ensure compliance with this policy and the Conditions for Digital Wrap of SCE Equipment by Third Parties, the responsible design AOR representative shall conduct an orientation meeting with requesting party, consisting of a review of SCE s policy and conditions. Third parties authorized to install Digital Wrap materials on SCE equipment shall perform all the work and absorb all costs for such activity. For details and specific requirements regarding the Digital Wrap Policy, please contact the local SCE Planning Office in your area. 28

Landscaping Around Edison Pad-Mounted Equipment Below are guidelines for landscaping around Edison pad-mounted equipment using shrubs, trees, low vegetation grass or fences. Landscape material shall be customer-owned and maintained Shrubs, trees or fences too close to equipment will be trimmed or removed in order to operate, inspect and perform maintenance to the equipment Landscape material and irrigation system shall meet required clearances per the AIM and UGS Manual, SS 602 Contact local nursery or arborist for guidance on: -Popular shrubs or trees grown in the area -Size and spread of shrub or tree at maturity Refer to UGS Manual, SS 602 for details and specific requirements regarding landscaping around pad-mounted equipment 29