B.C. ENERGY EFFICIENCY REGULATIONS FOR: Windows, Glazing, Doors, Skylights

Similar documents
0BC Energy Efficiency Act - Regulatory Proposal for Window and Door Products

In the Fall 2002 issue of HHE News I examined

Florida Building Code, 5th Edition (2014) June 30 th, 2015

IECC Compliance Guide for Homes in Virginia

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

Selecting Energy Efficient New Windows in Florida

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

2009 IECC Update. Scope. Content. International Energy Conservation Code

Selecting Energy Efficient New Windows in Georgia

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Selecting Energy Efficient New Windows in Arizona

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection.

Selecting Energy Efficient Replacement Windows in Nevada

T H E A A M A C E R T I F I C A T I O N P R O G R A M

Residential Weatherization Plus Program

Building Permit Application

Selecting Energy Efficient New Windows in California

NAFS and The 2012 Building Code

SECTION SERIES 1500 VINYL PATIO DOORS

Requirements to Obtain a Building Permit for a NEW HOME. 1. Completed application form. (Boxes A, B, C, D & E if applicable F and I)

Residential Windows, 3 rd edition Corrected index 1

Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE

Qualify for a credit of up to $1500 on your next federal tax return by purchasing energy smart products from Crestline.

Selecting Energy Efficient New Windows in Texas

Quality Building Products for over 50 Years

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS

windows energy-efficient choices

2013 BUILDING ENERGY EFFICIENCY STANDARDS

Glossary. Argon: An inert, nontoxic gas used in insulating glass units to reduce heat transfer.

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Certificate of Compliance ENV-1-C and Envelope Component Method ENV-2-C

Garden Windows Builders Vinyl

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

FIELD TESTING SERVICES

Insider Tips for Purchasing Replacement Windows

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

Maintenance Matters. Window and Door Replacement

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

FLORIDA PRODUCT APPROVAL

Introduction to Energy Codes & Green Building Programs

Astragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.

Energy Efficient Windows

Specifying Windows. Performance Standards

Unbeatable energy efficient glass curtain wall system

IEA-SHC Task 27: Setting Window Energy Efficiency Levels in Canada

Component Modeling Approach. Webinar Presentation Jan. 28, 2010

2014 British Columbia Building Code Changes

Assessing Curtain Walls

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

City of San Diego, CWP Guidelines

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

ENERGY EFFICIENCY PLAN REVIEW CHECKLIST

Energy Savings with Window Retrofits

The Florida Building Code

INDIANA COMMERCAL ENERGY CODE BASELINE STUDY

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

Sample Drawing Package for One and Two Family Dwelling Applications

Energy Analysis for Internal and External Window Film Applications for Existing Homes in Florida

FIRE RATED GLAZING System Guide

Energy Analysis for Window Films Applications in New and Existing Homes and Offices

Thermal Breakage Prediction

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

DISPLAY UNIT LABELING GUIDELINES FOR MANUFACTURERS AND RETAILERS

GENEVA HISTORIC PRESERVATION COMMISSION Policy Guide for Window Repair or Replacement Requests

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

Thermal Bridging of Masonry Veneer Claddings and Energy Code Compliance

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Plaisance 50. Windows and doors. Sapa Building System

1995 Model Energy Code Version 2.0

Energy Code Compliance With SIPs. Frank Baker, PFB Corporation Don Ferrier, Ferrier Custom Homes

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

2011 Energy Efficiency Expo!

Energy and Cost Savings

SERIES 3000/4000 DOUBLE SLIDER AND DOUBLE HUNG WINDOWS. Craftsmanship. Style. Performance.

Installer Training and Certification Overview

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

A GUIDE TO WINDOW AND DOOR SELECTION

ALUMINUM Guide Spec: Standard Aluminum Windows & Doors

Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri

Rating 1 the Energy Performance of Fenestration Systems in Commercial Buildings

Proposed 2012 Vancouver Building By-law

Impact-Resistant Windows and Sliding Glass Doors

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Training Tax Credits for Apprentices Income Tax Act (British Columbia)

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

ABOUT US... With a continued investment in machinery, the company now produces the following:

Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

Avantis 75. Windows & Doors. Sapa Building System

LCAs and EPDs of Building Materials

Transcription:

MEM INFORMATION BULLETIN - NOV., 2011 REVISED The purpose of this regulation is to improve the energy efficiency of manufactured fenestration products for all new and existing buildings. These products are a key component of a building s exterior envelope that affects the energy usage required to heat and/or cool the conditioned space. This circular includes updates to the Energy Efficiency Standards Regulation (EESR) for windows, glazing, doors and skylights that were approved July 21, 2011. Note that products manufactured for export from B.C. are exempt from these regulations. Information on the EESR standards for fenestration products is maintained at the following webpage: http://www.empr.gov.bc.ca/eaed/energyefficiency/pages/eeact.aspx This information circular is intended to help stakeholders understand the current requirements. It is organized according to the following 4 product types: 1. Windows, glazing and sliding glass doors for low-rise buildings: 4 storeys or less for residential 600m 2 or less for non-residential and skylights for all buildings 2. Windows, glazing and sliding glass doors for high-rise and large buildings 3. Glazing for installation in manufactured door slabs, side lites and transom lites 4. Door slabs Following the descriptions for the four product types, information is provided on labelling, testing and a flexibility provision for windows designed for a specific building. 1. Windows, glazing and sliding glass doors for low-rise buildings and skylights for all buildings (see below) for the product. This includes products being installed by builders. Applies to new and existing residential buildings that are 4 storeys or less and non-residential buildings with equal to or less than 600m 2 of floor space. This includes all Part 9 buildings in the B.C. Building Code and some additional residential buildings that are 4 storeys. 1

Test standards All products must be tested with one of the following standards: CSA A440.2-04, Energy performance of windows and other fenestration systems NFRC 100-2004, Procedure for determining fenestration product U-factors Minimum energy efficiency standards and effective dates The following maximum heat transfer rate (U-value) performance standards apply, in metric units of watts per square meter of product area per degree Kelvin. Product Type USI-value W/(m 2 K) (U-value) BTU/ (hr ft 2 K) Effective Date Vinyl and fibreglass framed windows 2.0 (0.35) March 1, 2009 Metal framed windows, sliding glass doors, curtain walls, window walls or storefront windows, with or without thermal break 2.0 (0.35) January 1, 2011 Wood framed windows and sliding doors 2.0 (0.35) January 1, 2011 Skylights of all material frame types 3.10 (0.54) March 1, 2009 Hinged or bi-folding doors which are fully glazed into aluminum, fibreglass or steel sash construction 2.0 (0.35) January 1, 2012 All ENERGY STAR for Canada qualified windows. Windows and sliding glass doors in residential high-rise buildings 5 storeys and higher (see regulation #2 below). Decorative windows that have stained glass panels, iron inserts or blinds, contained in a sealed, insulating glass unit. Windows installed in buildings designated as heritage buildings. Glazing replacements in an existing sash and frame provided the U-value of the replacement glazing is equal to or less than the U-value of the original glazing. Products installed in buildings that are compliant with ASHRAE 90.1 (2004, 2007 or 2010). 2. Windows, glazing and sliding glass doors for high-rise and large buildings (see below) of the product. Applies to new and existing residential buildings that are 5 storeys or more and non-residential buildings with more than 600m 2 of floor space. Excludes products installed in new buildings that are compliant with ASHRAE 90.1 (2004, 2007 or 2010) as per the BC Building Code (effective 2008), or required under the City of Vancouver Green Building Bylaw. 2

Test standards All products must be tested with one of the following standards: CSA A440.2-04, Energy performance of windows and other fenestration systems NFRC 100-2004, Procedure for determining fenestration product U-factors Minimum energy efficiency standards and effective dates The following maximum heat transfer rate (U-value) performance standards apply, in metric units of watts per square meter of product area per degree Kelvin. Product Type Windows, sliding glass doors, curtain walls, window walls and store front windows with framing materials other than metal (e.g., vinyl, fibreglass, wood), with or without metal reinforcing or cladding Metal framed windows and sliding glass doors, curtain wall, window wall or storefront, with or without thermal break USI-value W/(m 2 K) (U-value) BTU/ (hr ft 2 K) Effective Date 2.0 (0.35) January 1, 2011 2.57 (0.45) January 1, 2011 Products installed in buildings that are compliant with ASHRAE 90.1 (2004, 2007 or 2010) Energy standard for buildings except low-rise residential buildings. For existing buildings that meet ASHRAE 90.1(2004, 2007 or 2010), a professional engineer or architect can produce a signed and sealed letter of assurance that confirms the building s compliance with ASHRAE 90.1. Glazing replacements in an existing sash and frame provided the U-value of the replacement glazing is equal to or less than the U-value of the original glazing. Products installed in buildings designated as heritage buildings. i 3. Glazing for installation in manufactured door slabs, side lites and transom lites (see below) of the product. Test standards The standards are prescriptive therefore no test procedure is required. Minimum energy efficiency standards and effective dates. The following prescriptive standards apply. 3

Product Type Prescriptive Standards Effective Date Glazing for door slabs, sidelites and transoms Multiple glazed (2 or more) Low-E coasting between glazing 90% argon gas fill level with a compatible edge sealant system Spacer bars other than non-thermally broken aluminum box spacer bars June 1, 2009 All ENERGY STAR for Canada qualified doors. Products installed in hung door assemblies that have a maximum U-value of 2.0 W/m 2 /K, tested with NRFC 100-2004 or 2010; Procedure for determining fenestration product U-factors. Decorative glazing that have stained glass panels, iron inserts or blinds, contained in a sealed, insulating glass unit. Products installed in buildings designated as heritage buildings. i Products installed in buildings that are compliant with ASHRAE 90.1 (2004, 2007 or 2010) Energy standard for buildings except low-rise residential buildings. 4. Door slabs (see below) of the product. Test standard ASTM C518-04 Standard test method for steady-state rhermal transmission properties by means of the heat flow. Minimum energy efficiency standards and effective dates The following prescriptive standards apply. Product Type Prescriptive Standards Effective Date Door slabs Door panels must be insulated with products rated to a thermal resistance (RSI) greater than or equal to 0.875 (m 2 xk)/w June 1, 2009 4 Solid wood door slabs. Products installed in buildings designated as heritage buildings. i All ENERGY STAR for Canada qualified doors. Doors slabs in pre-hung door assemblies with a maximum U-value of 2.0 W/m 2 x K, tested and certified with NFRC 100-2004 or 2010; procedure for determining fenestration product U-values. Door slabs installed in buildings that are compliant with ASHRAE 90.1 (2004, 2007 or 2010) Energy standard for buildings except low-rise residential buildings.

Labelling for all products Permanent labels Permanent labels are required for all products. They must have the registered trademark, word mark or symbol of the certification organization or other tester designated to test under the Energy Efficiency Act. For windows, glazing for doors, skylights and transoms, the permanent label must: be affixed to the frame or a spacer bar of the product so that the label is visible at all times; or, be affixed to the frame or sash of the product so that the label is visible when the sash is open; or, be affixed as a transparent adhesive label to the glass of the product; or, be etched into the surface of the glass. For door slabs, the permanent label must: be affixed to the door slab so that the label is visible at all times; or, be affixed to the edge of the door slab so that the label is visible when the door slab is open. Temporary labels All windows, glazing, skylights and sliding glass doors require a removable label. Glazing for door slabs, transoms and door slabs do not require a removable label. The label must set out the U-value, as verified by a certification organization or other designated tester under the Energy Efficiency Act, expressed in metric units. The Window and Door Manufacturers Association of BC (http://wdma-bc.org/) has developed a standardized label which has been adopted by B.C. based certification companies. For more information, contact Intertek Testing Services or Quality Auditing Institute (see contact information below). Removable labels for windows and glazing installed in high rise buildings and large buildings can be in the form of a single certificate listing each product provided for a specific building, provided by the supplier of the products and posted in plain view at the building project for a period of at least 120 days after the last product has been installed. For example, qualified professional engineers or architects or the NFRC Component Modelling Approach can produce such a certificate: http://www.nfrc.org/cmaprogram.aspx Testing agencies for all products The following agencies can certify the U-value of products for the purpose of this regulation: Canadian Standards Association (CSA) International, Toronto, ON, Damtew Tesfaye, 416-747-2509 www.csa-international.org Intertek Testing Services NA Ltd., Coquitlam, B.C., 604-520-3321 http://www.intertek-etlsemko.com Quality Auditing Institute Ltd., Port Moody, B.C., 604 461-8378, www.qai.org 5

Agencies accredited by the National Fenestration Rating Council (NFRC), Greenbelt, MD, http://nfrc.org/. These agencies include: WDMA, NAMI, Keystone and AAMA. Professional engineers, registered with the Association of Professional Engineers and Geoscientists of British Columbia and architects authorized to practice in British Columbia (only for the products described below). Flexibility provision for windows and glazing designed for a specific building Flexibility is provided for windows, skylights and sliding glass doors (excluding doors) for low-rise and high-rise buildings that are designed for a specific building or fall outside of the scope of existing certification programs. Some products may be permitted that do not meet the maximum U-value requirements noted above (e.g., 2.0 W/(m 2 K)). Instead, proof must be provided by a professional engineer or architect that all products in the specific building meet the U-value requirement on average. The professional must use the test standards to verify the average performance CSA A440.2 or NFRC 100. Also, the products can be simulated or tested by the professional using the actual size of the product, not necessarily the size provided by the test standard. The Ministry does not require routine submission of proof of compliance for these products, but during enforcement may require a letter of assurance from the professional. Specific Text in the Regulation i designated heritage building means a building that is (a) a provincial heritage site within the meaning of the Heritage Conservation Act or otherwise included in the Provincial heritage register under that Act, (b) protected through heritage designation or included in a community heritage register by a local government under the Local Government Act, (c) protected through heritage designation or included in the heritage register by the Council under the Vancouver Charter, or (d) protected through heritage designation or included in a community heritage register by the Trust Council or a local trust committee under the Islands Trust Act Specific Text in the Regulation: http://www.bclaws.ca/ click on Statutes and Regulations click on E scroll down to Energy Efficiency Act click on 389/93 Energy Efficiency Standards Regulation Contact For further information, please contact: ERIK KAYE Energy Efficiency Branch, Electricity and Alternative Energy Division, Ministry of Energy and Mines, PO Box 9314, Stn Prov Govt, Victoria, B.C., V8W 9N1 E: Erik.Kaye@gov.bc.ca T: 250-356-1507 F: 250-952-0258 6 Last Updated: December, 2011