FLEXPOINT Machine Vision Laser MVstereo Series Pseudo Random Pattern Generator

Similar documents
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Series 6000 Torque measured metal bellow coupling

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

with Electronic Assistant

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Guideline Laser Series

Series 7500 Torque Sensor

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

Ordering Part Numbers:

Bluetooth UART/RS232 Module

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Laserlyte-Flex Alignment System

Remote Level Monitoring Unit

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Fingerprint Based Biometric Attendance System

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Industrial Bar Code Scanners

LwLVision-USB 2.0. Installation Guide

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Access Control Using Smartcard And Passcode

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

RS - SPM. Serial parallel translator module

Description. Dimensions. Features. precision works better

Hexadecimal and Numeric Indicators. Technical Data

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

PenMount 1302 PCI Control Board

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ABB Drives. User s Manual HTL Encoder Interface FEN-31

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

-Encoder with end or hollow shaft ø10-15 mm. hollow shaft ø12 mm -Resolution max. 32 ppr. -Resolution max ppr -Magnetic sensing

Three Channel Optical Incremental Encoder Modules Technical Data

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Basler. Line Scan Cameras

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

HDO700 P FIBRE OPTIC TRANSMITTER

Vertical Cavity Surface Emitting Laser OPV300, OPV310, OPV310Y, OPV314, OPV314Y

SPECTRO Series SPECTRO-3-FIO-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (cf. p )

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

FLYPORT Wi-Fi G

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

Fiber Optics and Liquid Level Sensors Line Guide

Reaction Torque Sensor

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

LED...A Q Series Sealed High-Intensity

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Digital Keypad Use s Manual

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

Absolute Rotary Encoder E6CP

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

GSM HOME SECURITY SYSTEM

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Triple Waveband Infra-Red Flame Detection

LED DOWNLIGHT ONE 50XX SERIES

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

CLV440/442 Bar Code Scanner

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Temperature & Humidity SMS Alert Controller

Electrical connection

SMS GSM Alarm Messenger

MultiViu Flex 7 Data Sheet

UniPi technical documentation REV 1.1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Adjustment functions for both span and shift have been incorporated

SPID Azimuth Antenna rotator Type: BIG-RAK/HR

Multifunction devices

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Vibration Monitoring System Adash 3600

DIODE PUMPED CRYSTALASER

In-Sight Hardware specifications

Single Photon Counting Module COUNT -Series

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

SINAMICS S120. Encoder system connection M 3 ~ Encoder system connection. 2/178 Siemens D

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

Advanced Data Capture and Control Systems

Color Mark Sensor with Red or Green LED E3S-VS

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

BRIEF INFORMATION Angular Position Sensors Single and double sensors

Industrial Bar Code Scanners

Magnetic proximity switches

Transcription:

FLEXPOINT Machine Vision Laser The MVstereo (PRPG) projects a dot matrix of 33,000 divergent dots. It is available with 660 nm and 830 nm. Laser Components offers an eye safe version for each wavelength. The MVstereo PRPG lasers include our new digital laser driver which offers various programming and reporting features. Applications 3D Stereo Machine Vision Gesture recognition Depth sensing Volume measurement Features 33,000 pseudo random dot matrix 660 nm or 830 nm Eyesafe Adjustable focus without removing the optics 4.5 30 VDC supply voltage 19 mm industrial housing Microprocessor controlled 1

Specifications Wavelength 660 nm 830 nm Output power versions 660 nm: up to 70 mw (still eyesafe) laser class 1 830 nm: up to 130 mw (still eyesafe) laser class 1M Number of dots 33,000 Pattern angles 660 nm: 46 x 32 830 nm: 60 x 42 Zero order intensity 660 nm: about 0.5% 830 nm: about 0.2% Digital modulation / trigger Analog power adjustment Bore sighting Pointing stability Focus Operating voltage Current consumption up to 2 MHz, rise time < 50 ns, TTL logic, active low default Linear range 0 to 5.0 V, max. bandwidth 1 khz, active low default 10 mrad << 10 µrad/ C Adjustable, preset or fixed 4.5 30 VDC, reverse voltage protection < 400 ma Operating temperature (housing) -20 to +50 C Storage temperature -20 to +60 C Housing material Housing dimensions Protection class Connector Accessories Aluminum, red anodized, potential free Ø 19 mm l = 90 mm with adjustable focus l = 66.5 mm with fixed focus IP54, IP67 as option M12 sensor connector Option: 2 m cable instead of M12 connector Mounts, connecting cable, power supply 2

Spot Size and Depth of Field RS-232 Commands Saving data and settings on the internal EEPROM These modules have the option of storing relevant data and settings on the internal EEPROM. Data such as operating time can be stored; as well as operation parameters and production settings. Command Description Return value trig x dima xx yy Z mon1 x: active high/active low 1: active low (default) 2: active high analog power adjustment: xx max. power adjustment [00... 50] (e.g. 00 = ^ 0V... 50 = ^ 5V) yy min. power adjustment [00... 50] (e.g. 00 = ^ 0V... 50 = ^ 5V) z modulation type [0, 1 or 2] 0: no modulation (disabled) 1: active low (default) 2: active high 12-bit resolution [0..4095]digits. permanent swm ESC end of permanent swm supply voltage [V] internal voltage [V] laser diode monitor current [µa] laser current [ma] temp temperature temp: c time operating hours days hours minuts lasc laser current laser current [ma] 3 x) recommended terminal program: Tera Term, for communication

Pin Out PIN Description Comments 1 V IN input voltage 2 V power analog power adjustment input 3 V Mod trigger input 4 RxD UART; communication interface 5 TxD 6 C2CK firmware flash access 7 C2D 8 GND ground 1. Analog power adjustment Output power can be adjusted to any desired value within the capabilities of the installed laser diode. Due to safety regulations and laser classifications, the maximum output power can only be set by the factory during manufacture. Please note: The maximum laser power is set during production; and the user can only reduce the laser power. This is locked via the firmware and password protected. When using analog power adjustment, there is a distinction between active high and active low. 1.1. Active high The output power of the laser is proportional to the input voltage. The input voltage can be set via RS-232 commands in the range 0 5 V. 1.2. Active low (default) Inverse power adjustment follows an opposite relationship to the input voltage. The following graph (fig. 1) shows this relationship: 4

Fig. 1: Analog power adjustment 2. Digital modulation / Trigger Triggering is controlled via an external TTL signal (transistor transistor logic). The triggering signal can be switched between 2 input types: - active high - active low (default) Fig. 2: Digital Modulation / Trigger 5

MVstereo with adjustable focus MVstereo with fixed focus Ordering Code FLEXPOINT Series Wavelength (nm) Output Power Power Options Pseudo Random Pattern Generator Type Focus Options FP MVstereo YYY XXX MD XXX XXX XXX 650 830 up to 70 mw for 660 nm up to 130 mw for 830 nm D= Dimmable (analog power adjustment) Default: active low M= digital Modulation Default: active low 335 (30,000 dots for 660 nm) 332 (30,000 dots for 830 nm) F= adjustable focus FYYY= prefocused to YYY but still adjustable FIXYYY= fixed focused to YYY Examples: µc settings cable length OEM customer name 6

Precision Mount for Laser Modules with 19 mm diameter FP-MPT-19 For flat surface mounting 360 rotation in 2 axes + parallel movement FP-MPS-19 For mounting on a 16 mm shaft 360 rotation in 2 axes + parallel movement (+ rotation on shaft) 7

Standard Mount for Laser Modules with 19 mm diameter FP-MS-19 FP-MG-19 805/16 / V2 / IF / lasermodules/mvstereo