AIR CONDITIONING... SMALLER is SMARTER!

Similar documents
AIR CONDITIONER ENERGY-EFFICIENT

These guys are good really good.

DECISION TIME? A REPAIR OR REPLACEMENT GUIDE FOR HVAC EQUIPMENT REPAIR OR REPLACEMENT GUIDE

DECISION TIME? A REPAIR OR REPLACEMENT GUIDE FOR HVAC EQUIPMENT

Why Daikin? 2015 Houston, Texas USA

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Automobile Air Conditioning Primer

DX20VC. Variable-speeD Comfortnet Compatible. Comfort for Life

The phase out of R22. Phase out of HCFCs

DX14SA AIR CONDITIONER ENERGY-EFFICIENT UP TO 15 SEER SINGLE SPEED COMFORT FOR LIFE

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

"I'm a Daikin Comfort Pro"

Standard Heating and Air, Inc Committed to Excellence

Hill PHOENIX is committed to creating value for its customers, employees and shareholders while using sustainable business practices

Refrigerant Update and Beyond. Stephen Niles Refrigeration/Commercial Sales Manager

Rusty Walker, Corporate Trainer Hill PHOENIX

Production of R-134a

Glossary of Heating, Ventilation and Air Conditioning Terms

Refrigerant Compliance Policy

Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B

Indoor Coil Corrosion Industry Research Report

USC CFC Leak Repair and Recordkeeping Procedures

Two-Stage Air Conditioner with Puron Refrigerant

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

It s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.

Answers to Your Questions from the Webinar

IV. Rear Mount System

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Indoor Coil Corrosion

Are these noise cancelling devices needed to make your chiller quiet??

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

R-32. The next generation refrigerant for air conditioners and heat pumps

NYU Safety Policy Manual

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Guidance for Stationary Refrigeration & Air- Conditioning

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

Commercial Portable Air Conditioners

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume Refrigerant History

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Air conditioners Heating & Cooling

ADVANCING FLAMMABLE REFRIGERANT ADOPTION IN NORTH AMERICA

RESIDENTIAL PRODUCT LINE CARD 15.5

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

ACR Group, Inc AMEX: BRR Investor Presentation February ACR Group, Inc AMEX: BRR

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Guidance for Stationary Refrigeration & Air-Conditioning

How To Understand Evaporator

Safeguard Storm Doors Beauty, the security of advanced design, and the guarantee of a lifetime.*

Air-cooled Chillers with High Speed Centrifugal Compressors

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Plan Number A Cross Beam Dr. Charlotte, NC Simplified Service Plan. Air Conditioning.

BOMA BESt Assessment Overview

Select Radiators Installation Guide

HCFC phase-out has started.

Testimony of Jerry Bosworth President, Bosworth Air Conditioning and Heating, Inc., Galveston, Texas And Vice Chairman ACCA The Indoor Environment

Dehumidification Frequently Asked Questions

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Local Dealer:

How Do Smart Buildings Make A Building Green?

Form 0.5 chair, 2805 and 2806

Replace Your CFC Air Conditioning Chiller

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

Planning for the ban on R22 in building air conditioning

Part A: Fluid properties

Air-Conditioning Buying Guide

Infrastructure & Cities Sector

Refrigerants for Residential and Commercial Air Conditioning Applications

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

SWIMMING POOL HEAT PUMP

PAAM COMMERCIAL PRIVATE LIMITED

Analysis of Alternative Refrigerants to HCFC-22

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

How air conditioning works

Air Conditioning 101. STN Presentation AC101

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

MACHINES FOR REFRIGERATION AND AIR CONDITIONING

Daikin VRV Retrofit Provides Comfortable, Quiet Rooms for Residents

Trane XR Air Conditioners. Comfortable, cool and smart.

Indoor Coil Corrosion

Mohan Chandrasekharan #1

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Commercial Hot Water. Make a difference...

Company Profile. Batec Air Conditioning & Refrigeration, PO BOX 1788 Springwood 4127 Ph: Fax:

(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS

KONRAD. Hybrid Fancoil Series

A/C refrigerant system, overview

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

SECTION HEAT PUMPS

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

LG Electronics AE Company, Commercial Air Conditioning

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Transcription:

THE FUTURE OF AIR CONDITIONING... SMALLER is SMARTER!

THE FUTURE BEGINS TODAY. Smaller is Smarter Long ago the HVAC industry determined that the combination of copper tubing and aluminum fins provided the most efficient transfer of thermal heat available. Today, the Goodman brand has improved upon this industry standard by making the copper tubing smaller and smarter. The result is an air conditioner or heat pump unit that can offer high efficiency, use less refrigerant, and deliver money-saving and energy-saving comfort to homeowners for years and years. Goodman s SmartCoil coil is our most advanced and most efficient that is manufactured in North America. And, several patent applications are pending on this coil as a result of the technology required to engineer and manufacture it. 3/8 Beyond the excellent thermal transfer properties of R-410A refrigerant when it s coupled with 5mm copper tubing, the smaller diameter tubing requires less refrigerant to achieve the same efficiency rating. Although the 5mm copper tubing has a smaller diameter, the tubing s wall strength is as strong as the old 3/8 inch tubing. SIZE MATTERS The smallest amount of heat transfer occurs in the center of the tubing. The larger the tubing size, the larger the area where minimal heat transfer increases. Images enlarged to show detail. 5 mm Standard 3/8'' Copper Tube Goodman s New SmartCoil 5mm Copper Tube

R-410A IS THE FUTURE. In a few months, R-410A refrigerant will become the sole refrigerant used by the HVAC industry in the manufacture of new equipment. R-410A refrigerant does not contain chlorine. This makes it an environmentally friendly refrigerant compared to its predecessor R-22. Over a decade ago, the federal Clean Air Act was amended to begin a mandatory phase out of the production and use of many ozone depleting substances, including a commonly used air conditioning refrigerant know as R-22. By 2010 air conditioning and heat pump manufacturers in most countries will no longer be using refrigerant R-22 in new equipment because it is being banned around the world as part of the global phase out of ozone-depleting CFCs (chlorofluorocarbons) and HCFCs (hydrochlorofluorocarbons). In addition, at that time R-22 refrigerant cannot be manufactured or imported into the country, except for use to repair or maintain HVAC equipment manufactured prior to that year. As R-22 refrigerant is phased out of production, its cost could increase substantially. Several years ago, the automotive industry migrated from the use of R-12 refrigerant to an environmentally-friendly refrigerant know as R-134. During this transition, the cost of R-12 refrigerant skyrocketed. Given the history of refrigerant prices when a phase out of a product is mandated, one can presume that future repairs and maintenance needs of HVAC units that use R-22 refrigerant will likely cost more and more as R-22 refrigerant is phased out of production. With R-410A refrigerant becoming the sole option for new central air conditioners and heat pumps, HVAC manufacturers have already started the process of incorporating the new refrigerant into their product line. Further, the Goodman brand has taken the extra step to maximize the efficiency and performance of its products that use R-410A refrigerant. The Goodman brand enjoys a rich history of providing the perfect blend of energy savings, reliable and dependable operation throughout the entire line of refreshingly affordable heating, air conditioning, and indoor air quality products.

SmartCoil generates Greater Performance. Thermal transfer is a major component in the operation and performance of an air conditioning or heat pump product. One simple job of the refrigerant in an air conditioning or heat pump system is to transfer heat, and, in the process, humidity, from the air. Because the majority of thermal transfer occurs in the condenser and evaporator coils, the Goodman engineers readily accepted the challenge of optimizing thermal transfer in the condenser coils for products that use R-410A refrigerant. After all, the heritage of the Goodman brand involves energy-saving, money-saving, and resource-saving heating and cooling systems. So the introduction of R-410A refrigerant offered the perfect opportunity to optimize the heat transfer efficiency properties of R-410A refrigerant. In their quest, Goodman s engineers quickly resolved that the thermo-physical properties of R-410A refrigerant are a great match for the heat transfer characteristics of 5mm diameter copper tubing. Scientific theory aside, it s easy to see why smaller tubing in the condenser coil optimizes heat transfer. GROOVED COPPER TUBING Grooves increase thermal transfer of R-410A refrigerant in conjunction with 5mm copper tubing The refrigerant molecules swirl inside the grooved copper tubing, increasing the time the refrigerant molecule comes into contact with the inside of the tubing R-410A MOLECULES Slots increase the total surface area of the tubing and increase the amount of space available for the refrigerant molecules to touch the inside of the tubing, optimizing heat transfer Grooved (Artist s rendering)

THE HEAT TRANSFER PROCESS Maximum heat transfer between the refrigerant molecules occurs highest at the outside edge of the tubing Through osmosis, additional heat transfer occurs when the molecules in the center of the tubing touch the molecules at the outer edge of the tubing, releasing heat and becoming cooler The smallest amount of heat transfer occurs in the center region of the tubing. The larger the tubing size, the area where minimal heat transfer occurs increases in size. Using the Second Law of Thermodynamics, heat can be transferred into cold during the transfer of energy such as the R-410A refrigerant molecule touching the side of the 5mm copper tubing The physical size of the area that comes into contact and the length of time the contact occurs helps optimize the heat transfer. And that s specifically what makes the R-410A refrigerant and the 5mm copper tube combination work so well together. SAVING SPACE Goodman units with SmartCoil and R-410A refrigerant use 25% less refrigerant and the overall unit requires 15% less volume.

U.S. Clean air act phase-out schedule for Hchfss 100% 80% 60% 40% SUPPLY 2003 HCFC-141b Phase Out 2010 HCFC-22 Phase Out No New Equipment 20% Aftermarket Demand* 0% 1996 2000 2004 2010 2015 2020 *Estimated U.S. Stationary Aftermarket Demand 2007 (DuPont) 35% of Original Cap 10% of Original Cap Stop Production of HCFC-22 Good Neighbor Manufacturing The SmartCoil copper tube, aluminum fin condenser coil is designed from two metals widely known for their ability to be recycled. It s just one more example of good neighbor manufacturing endorsed by the Goodman Manufacturing Company. Our manufacturing facilities, all located in the United States, constantly strive to implement procedures and processes that help to reinforce our environmental stewardship. Here are just a few examples of our manufacturing procedures that have helped to make the manufacture of our products green. The painting process at our manufacturing plants does not emit any volatile organic compounds (VOC s). This has been achieved by employing powder paint and a baking process for all painted components of our heating and cooling products. Manufacturing processes that utilize oil as a lubricant or coating have been improved so that our consumption of these chemicals has been greatly reduced. Further, we work with our suppliers to capture the most environmentally friendly pallet building materials to assist in the reduction of emissions. These are just a few of the manufacturing initiatives and processes that support Goodman s environmental stewardship. Many of the components used in the manufacturing process are recycled, such as scrap steel, aluminum, copper, cardboard and oil. Cogent environmental procedures and policies are implemented on a continuous basis throughout our manufacturing operations. 2008 Goodman Manufacturing Company, L.P., Houston, TX 11/08 www.goodmanmfg.com CB-5MM