BUILDING PERMIT APPLICATION CHECKLIST

Similar documents
CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Basic Requirements for Residential Plan Review _

Residential Building Permits

BUILDING SAFETY UNIT

Residential Building Permit Process

Bureau Veritas Contact Information

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Requirements for Building Application Submission

Residential Plan Routing Information

PLAN SUBMITTAL INFORMATION

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Footing and Temporary Power Inspection

Washoe County PLAN SUBMITTAL

Uncovered Decks & Porches

POST AND FRAME STRUCTURES (Pole Barns)

A Homeowner s Guide to Building Permits

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA ,

INFORMATION BULLETIN NO.

Sample Drawing Package for One and Two Family Dwelling Applications

Building Information Packet

Patio Covers / Carports

BUILDING PERMIT SPECIFICATIONS

How To Build A Basement House

NEW OR ADDITIONS TO GARAGE/SHOP/STORAGE PERMIT REQUIREMENTS

RESIDENTIAL WOOD DECKS

Chapter 6 ROOF-CEILING SYSTEMS

Residential Deck Safety, Construction, and Repair

INFORMATION BULLETIN NO.

Residential Decks. Planning and Development Services Department

Georgia Association of Home Inspectors

Certification: Building Plans Examiner. Exam ID: B3

Residential Inspection Guidelines

Does Wall Township require an inspection by the building department on resale of a home?

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

An Applicant s Guide to Residential Building Permits

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

A Guide for the Homeowner/Builder

Page & Turnbull imagining change in historic environments through design, research, and technology

COUNTY OF LAKE COMMUNITY DEVELOPMENT DEPARTMENT

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Single Family Residential Basement Finish

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Estimated Cost of Repair

STANDARD OPEN PATIO COVER

Requirement checklist to obtain a building permit for a: NEW SINGLE FAMILY DWELLING RESIDENTIAL ADDITION

Zoning Department DECK PERMITS. Checklist

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

Solar Panel Installations

PDmB, Inc. Definitions

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

2014 FLORIDA BUILDING CODE

Development Services City of Lawrence, KS

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

Single Family Residential Building Permit Questions & Answers

PARK COUNTY BUILDING PERMIT GUIDE PO Box 517 Fairplay, CO Fax: Inspections:

APPLICANT / CONTACT:_

How To Make A House Safe

Uniform Construction Code (UCC) Building Permit Application Package

TOWN OF SPENCER Office of Development & Inspectional Services

BUILDING PERMIT RESIDENTIAL BASEMENT FINISH

ESSENTIAL CURRICULUM ARCHITECTURAL DESIGN ACADEMY

Residential Adjustments. Overview 4.1

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

October 5, 2015 Dear Client,

dpd 316 Seattle Permits Tip Subject-to-Field-Inspection (STFI) Permits Projects that Qualify as STFI

Building Code Inspections and Fees

Attached/Detached Patio Cover/Carport

SWIMMING POOL / SPA PLAN REVIEW CHECKLIST

Section A Roof Truss

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

I NI NP R Inspected Items

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

8/18/14. Introduction to. Framing. Terminology and Concepts

Requirement checklist to obtain a building permit for a: RESIDENTIAL RE-ROOF

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

City of St. Charles Basement Finish or Remodel

Building Permit Application

Site Development Information Worksheet for single family residential development

Home Inspection Report

COMMONLY USED RESIDENTIAL BUILDING CODES

Single Family Dwelling Submittal Requirement Checklist with Basement

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

Maximum Floor Area and Maximum Development Area

Notice to Property Owners

Name of course: Residential Construction Site Management (RCSM) Level 1

South Carolina Home Inspector Standards of Practice

Pre-Drywall Inspection Report

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

A Homeowners Guide To Code Enforcement

Transcription:

BUILDING PERMIT APPLICATION CHECKLIST Evidence of Onsite land use review/approval required on all permit applications proposing new or expanded commercial, multi-family residential, community services, or industrial. Onsite application to include: (Residential) Application fee, Two (2) plots plans and One (1) floor plan Fire Department review & clearance to include: Fire Flow Form & Fee (if applicable) PID clearance (recommended on new construction) Three complete sets of scaled drawings to include: Plot plan, floor plan, foundation plan, wall framing plan, roof framing plan and/or truss calcs and four elevations. (Smaller projects ie; deck, garage conversion, etc. does not require elevations) On ALL commercial projects one additional complete set of plans for fire department review Two sets of wet signed engineering calculations (if applicable) Two sets of signed energy calculations (if applicable) Completed driveway encroachment permit application along with proof of liability insurance (min. amount 1,000,000.00) and surety bond (min. amount 10,000.00) forms\bpapp.lst (rev. 3/25/10)

TOWN OF PARADISE Community Development Department Building Division PREPARATION OF RESIDENTIAL PLANS GENERAL REQUIREMENTS FOR NEW CONSTRUCTION AND ADDITIONS All plans must include the legible name of the architect, engineer, designer or other person preparing the plans. The drawings must be clear, complete, and must show in detail how the proposed work will comply with the codes. All drawings must be to a common scale. All plan views must be drawn to a minimum scale of 1/4" = 1'. Drawings on graph paper are not acceptable due to the difficulty of distinguishing graph lines from drawing and dimension lines, especially on photocopies. Completeness and clarity of the drawings is essential to avoid delays in the issuance of your permit. Your plans would be considered complete if you could give them to a total stranger and he or she could understand how the building will be constructed and what the finished project will look like. ENGINEERED DESIGNS All construction which falls outside the category of "Conventional Light-Frame Construction" per Section 602 of the 2013 California Building Code must be designed by an architect or engineer with a California license. This includes, but is not limited to, truss systems, retaining walls over forty-eight inches high, foundations with pilings or caissons, roofs on posts such as carports and patio covers which are freestanding or which extend more than 6' beyond the building to which they are attached, and wall bracing systems which are not described in Section 602. Buildings with more than two stories also require engineering. Structural calculations for such designs must be submitted in two copies with the designer's stamp, signature, and license number. All design elements required by the calculations must appear on the plans as well as in the calculations. The builder or field inspector should not need to refer to the calculations to see how the structure is to be built. TITLE 24 ENERGY COMPLIANCE DOCUMENTATION "Energy calcs" are required for projects creating heated or cooled space. This documentation shows how the project will comply with California Energy Commission regulations for energy conservation. For most projects, this documentation is best prepared by an experienced professional. INFORMATION REQUIRED ON DRAWINGS For purposes of accuracy, clarity and efficiency in the plan review, construction and inspection processes, the following minimum plans standards are adopted as policy by the Town of Paradise, Community Development Department, Building Division. Use this as a checklist when preparing your plans. Some items may not apply to your project but if you address all those which do, unnecessary delays in the plan review process can be avoided. If you have questions about any of the items on this list we will be glad to discuss them with you.

2 Site Plans must be provided for new buildings and for any work which alters the footprint of an existing building. Site plans must be drawn to a common engineers scale and must show: Property lines Gradient lines Lot dimensions Front, rear, and side setback distances to buildings Septic tank, leach field and replacement area Topographic features such as grade elevations streams and drainage areas All existing and proposed structures on the property including covered patios, porches, and roof overhangs longer than 3' The proposed building's exterior dimensions All public and private easements Underground gas, electric and water lines Proposed and existing gas and electric meter locations North arrow showing the compass orientation The name of the adjacent road(s) and and the road centerline(s) Driveway location Storm water management plan

Floor Plans are required for all new construction. They should be drawn to 1/4" = 1' scale and must include: A separate plan for each floor level Descriptions and dimensions of all rooms Locations and descriptions of all Braced Wall Panels Locations and sizes of doors and windows Description of window types (and doors if glazed) Locations and sizes of skylights (indicate if openable) Changes of ceiling or wall height Location and size of attic access opening(s) Required landing at exterior doors Plumbing fixtures and appliances Location and description of room heaters Location of heating and cooling appliances Method of providing combustion air for fuel-burning appliances in confined spaces Locations of electrical service panel, subpanels, receptacles, lights, switches, fans and smoke detectors (may need to be shown on a separate electrical plan if the floor plan is too crowded to maintain clarity) Location and size of posts supporting roof or ceiling beams Locations of section views For additions, adjacent existing rooms must be included showing locations of windows and doors For alterations to existing rooms, the plans must clearly show what is existing and what is new 3

4 Foundation Plans are required for all new construction. They should be drawn to 1/4" = 1' scale and must include: All continuous footings with length of each segment in floor plan view Cross-section detail(s) with markers showing where they apply - may be on a separate sheet Foundations for interior bearing walls Locations of all pier footings (centers dimensioned in both directions) Size and depth of all pier footings Location and description of the embedded portion of all holdowns Post anchor specifications for exterior posts For slab floors the following is also required: Footings or 12 footing with two (2) #4 rebar top and bottom under interior Braced Wall Panels with note on how sills will be attached Floor Framing Plans for the first story are normally included on the foundation plan. If the building has more than one wood-framed floor level, a separate floor framing plan must be provided for each level unless no floor is above the other at any point, such as a split level. The following must be included: Size and to spacing of girders Size and to spacing of joists Dimensions showing spans of girders and joists Size and span of any floor beams Underfloor posts at all point load footings Additional joists or blocking under interior Braced Wall Panels Location and size of underfloor access opening Calculations detailing how the underfloor ventilation requirement will be met (see worksheet on page 8)

Roof Framing Plans are required for all "stick-framed" roofs. They are also required for "stick-framed" portions of truss roofs, such as overlay (or "California") framing, porch roofs, etc. Ceiling framing may be included on the roof framing plan or the floor plan if adequate clarity can be maintained. Complex structures may need separate roof and ceiling framing plans. These must include: Roof pitch Header sizes for all openings in bearing walls (may be on floor plan instead) Location, size, grade and span of each roof or ceiling beam (or on floor plan) Sizes, to spacing and spans of rafters and attachment detail Sizes, to spacing and spans of ceiling joists and attachment detail Locations and sizes of purlins Location of each purlin support, showing where it is supported by a beam or bearing wall Calculations detailing how the attic ventilation requirement will be met (see worksheet on page 8) For truss roofs the following must be submitted if applicable: Truss layout Engineering for each truss Gable stud bracing detail Web bracing specifications Bottom chord bracing specifications Hat truss attachment specifications Truss-to-truss hanger specifications Overlay framing specifications Calculations detailing how the attic ventilation requirement will be met (see worksheet on page 8) 5

6 Section Views are helpful for clarifying framing in complex buildings. Even in simple structures such as garages a "typical" section view can be very helpful. More complex buildings may require several section views. The location of each section view must be marked on the floor plan. Section views should specify all materials not called out on one of the plan views such as subflooring, roof sheathing, wall framing, insulation, etc. as well as vertical dimensions not shown on other drawings. Details should be numbered and the number of each one marked at the appropriate location(s) on the plan views.

Elevation views are required for each side of all new construction. They are usually drawn to 1/4" = 1' scale, but may be drawn to 1/8" = 1' scale if clarity is maintained. They should show: Approximate grade including actual slopes at the site Type of siding and roofing Windows, doors and skylights Porches and decks Roof overhangs Chimney extensions 7 Drawings of the following type have little or no value to a plan checker. Submittals which consist primarily of such drawings will probably not be acceptable for review.

8 N:\Cdd\Building\Handouts\Preparation of residential plans - REV 03/21/14