Groundwater Sampling for Helium / Noble Gases

Similar documents
PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

CHEMICAL CLEANING UNIT Product number:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

How To Launch A Rocket From A Formica

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Machine needle shut-off nozzle type-a

AUTOMATIC CHANGEOVER MANIFOLD Series 915

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Wind Direction Smart Sensor (S-WDA-M003)

Installation instruction CASAFLEX - Connecting piece DN 100

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

The Strange Effects of a Vacuum

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Appendix 8 Step-by-step guide to constructing small-scale aquaponic systems

W I T H I N J O I ST S I N STA L L AT I ON

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

INSTRUCTIONS Edition AC

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

INSTALLATION INSTRUCTIONS FOR VW MK5

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

Transpiration of Plants

Hose Clamps & Fittings

Air Conditioner Water Heater Model ACWH18

Fish Grader User Manual

This instruction is valid for all ACD pump models shown on page 2

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Residential Plumbing

Coolflo Safe Touch Shower Mixing Valve ST20015CP

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

INSTALLATION, OPERATION & MAINTENANCE MANUAL

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE ABSORPTION OF CARBON DIOXIDE INTO WATER

Stainless Steel Pipe Fabrication

WATER SERVICE 2

Your safety and the safety of others are very important.

Rules for Safe Operation

Solar Hot Water Heaters

Drive shaft, servicing

SELECTION, APPLICATION AND MAINTENANCE

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

Maintenance and Service Instruction

BUILDINGA 1/10 SCALE FLATBED TRAILER

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

How To Replace A Reverse Osmosis Water Tank

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

Fiberstars Mini Lighted Laminar Flow Fountains

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Sprinter Fuel Filter Installation

Installation Instructions

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Times Microwave Systems Hermetically Sealed Assemblies

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

INSTANT HOT WATER RECIRCULATING SYSTEM

VW Caddy W INSTALLATION INSTRUCTIONS

The CO2-reactor 1000 has been developed for the fertilisation of freshwater and marine aquaria Carbondioxide.

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Private Water Supplies Sampling Manual. A Field Guide

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Select Radiators Installation Guide

Osmosis. Evaluation copy

GK Packing System Welding Instructions

TYPE E Main Valve Sizes 3 /8 through 12

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

MODEL #320 - (* Using Bromine tablets with this device is not NSF certified)

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Tri-Homo Style Operation and Maintenance Instructions

Watts Pure Water Systems

Softail Oil Change. Tools

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Single-Use Flow-Through Cell ph FTC-SU-HP8

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

MODEL J SERIES CONVERTER

CG PTFE Diaphragm Liquid Transfer Pump

Operators manual Basic water heater

1 DESCRIPTION OF THE APPLIANCE

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Rotary IBC AdBlue Pump

CEILING CASSETTE FAN COIL UNIT

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Puddle Flange. FRANK Puddle Flange

Stainless Steel Single and Dual Circulation Kits

Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators

product manual H-4210A PORTABLE STATIC CONE PENETROMETER

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

Pressure Testing (Hydrostatic / Pneumatic) Safety Guidelines

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Transcription:

Institute of Environmental Physics University of Heidelberg Im Neuenheimer Feld 229 D-69120 Heidelberg http://www.iup.uni-heidelberg.de Prof. W. Aeschbach-Hertig phone: +49 (0)6221 54 6331 fax: +49 (0)6221 54 6405 e-mail: aeschbach@iup.uni-heidelberg.de www: ( )/institut/forschung/groups/aquasys/ Groundwater Sampling for Helium / Noble Gases using copper tubes General remarks The art of sampling dissolved gases in groundwater, especially such a mobile gas as He, lies in resolving the following potential problems: 1. Avoid gas exchange with the atmosphere during sampling Solution: Use tight connections between well and sampler 2. Avoid air contamination by inclusion of air bubbles Solution: Flush sampler and tubing well, remove any remaining air bubbles 3. Avoid loss of dissolved gases by degassing (formation of a gas phase) Solution: Keep sampling system under sufficient pressure to suppress degassing 4. Avoid leakage of gas in or out of the sample during transport and storage Solution: Use absolutely gas tight containers (copper tubes). Well selection and preparation Not all wells or pumps are suitable for noble gas sampling, because of the requirements of closure against air or other gas phases and of sufficient pressure to prevent degassing. Closed boreholes are highly desirable, open wells or springs are problematic, because they allow gas exchange. Ideal are artesian wells with sufficient pressure or wells pumped by a submersible pump. Sucking pumps should be avoided, they most likely induce degassing. Pressure tanks often contain a pressurized gas phase, which may exchange with the water and induce uncorrectable gas fractionations. If pressure or storage tanks are present, the water should be taken before it enters the tanks. Sampling after chemical treatment or filtering of the water should also be avoided if possible. Before sampling, the well should be sufficiently flushed (pump out at least once the volume of the borehole). During flushing, temperature and electrical conductivity should be checked to see if the values stabilise. After flushing of the well, a tight connection to the copper tube has to be established (see below).

Connection of sampler to well, pressure regulation The sample containers consist of a copper tube which is mounted on an aluminum rack (see figure). On both ends, the tube is fixed by stainless steel clamps, which are used to create a gas-tight seal. Before connecting to the well, the copper tube should be centered in both directions, i.e., along the length of the aluminum frame and between the two screws of the stainless steel clamps. The ends of the tube should stick out of the frame on both sides by a few cm. These end-pieces are needed for the connections both in the field and in the lab. The copper tube has to be squeezed completely within the cutting edge of the clamps, therefore it needs to be centered in the clamps. The adjusted copper tube is fixed in its position by tightening the screws by hand. The copper tube is connected to the pump, tap or other point of water withdrawal through flexible plastic tubing. Ideally, a tap near the well head is used. Often, several hoses need to be connected in order to reduce the diameter to the size of the copper tube. We usually deliver a piece of tubing that fits tightly on the copper tube. We recommend to use this piece as the last part in the connection. In order to withstand water pressure, we use inner braided PVC tubing, and in order to allow detection of bubbles, we prefer transparent tubing. All connections, also on the copper tube, should be secured with hose clamps. The complete tubing has to be sufficiently flushed (about one minute) and checked for bubbles. Bubbles tend to stick at connections. They can be removed by squeezing and bending the hoses or knocking against the tubing. During the whole sampling procedure, it is recommended to hold the copper tube at a slight angle to the horizontal, such that air bubbles can rise along with the water flow and are flushed out of the system. Sometimes, air is sucked in at connections of the tubing, particularly if the diameter of the tubing increases in flow direction. Try to avoid such configurations (always go from large to small diameter) and tighten all fittings to avoid leakage. Slight leakage out of the tubing may be tolerable. If bubbles form due to degassing of the water, an increase of pressure can often help to suppress degassing. If the pressure can be regulated, keep it as high as the stability of the connections allows. The stability can be checked easily by putting a thumb on the outlet. The pressure should also be regulated such as to avoid any sound (rush) in the tap or connections, as it may indicate turbulence or degassing.usually, the pressure is fine when the water jet after the copper tube reaches for several meters. If the pressure is low or if it is impossible to avoid bubbles, you may take the sample anyway but mark it accordingly.

Closure of the samplers Once the system is well rinsed, the sample is isolated by first closing the outlet clamp, and then the clamp on the inlet side. The clamps are closed by tightening two screws using a hexagonal wrench (usually delivered with the containers, please return with samples!). First tighten one screw until the two parts of the clamp touch on this side. Then close the other screw almost entirely, and return to the first screw to do the same. Finally tighten both screws as much as you can with the wrench, but without additional tools. The clamps are correctly closed if there is no space left between their two parts. Check that no gap is visible between the clamps in the vicinity of the screws. The copper tube is now shut absolutely gas tight. If the connections break before the inlet side is closed, replace the bad sample tube with one of the spare cooper tubes that we usually deliver, and take a new sample. Sample identification and additional data To identify the samples, you may put stickers or tape on the aluminum racks or write directly on them with a water-proof marker. Usually we will provide or even prepare some tape on the frames, on which the sample identification can be noted. Additional information should be written down in a field book. For each sample, note at least the sample identification, location, well name, and date of sampling in your field book. To interpret noble gas data, we need some additional data, such as temperature and salinity (electrical conductivity) of the water, altitude of the well, altitude of the presumed recharge area, and if possible mean annual temperature in the recharge area. At least the water temperature and the approximate elevation at the sampling site should be known. We strongly recommend to measure temperature and electrical conductivity of the water during sampling for noble gases. Packing and transport After sampling, the containers may be shaken to remove the water in the outer ends of the copper tubes. In the case of very saline water, the containers (especially the steel clamps) should be flushed with fresh water to prevent corrosion. The containers are best packed in our boxes, where wooden ledges are used to staple them in rows of 6 containers each. The ledges keep the containers at fixed distance and prevent them from moving. If smaller numbers of samplers are shipped in improvised packaging (cardbord boxes or similar), care must be taken to avoid bending or even breaking of the outer end-pieces of the copper tubes. Try to protect the ends against impacts during transpor.

The most important points step by step: Pump long enough to flush the borehole completely. Find a suitable tap or other outlet of the well/pump for connection. Avoid pressure tanks, sucking pumps, and any contact with air or gas phases. Connect the copper tube by a tight combination of tubing. Check if the connections withstand the pressure when the outlet is closed. Flush the tubing, remove bubbles in the hoses, keep pressure high. Check that the Cu-tube is approximately centered on the clamp. Close clamp at the outlet completely (no gap), then at the inlet. Identify the samples (name, location, date). If possible note temperature, conductivity and altitude of the well. Protect the ends of the copper tube from bending and breaking.

from pump tap, valve (if present) secure connections with hose clamps rack pinch-off clamp washer connecting end-piece screw copper tube plasic tube sampler = copper tube on aluminum rack Schematic drawing of the setup for noble gas sampling from groundwater wells. One pinch-off clamp is shown enlarged in the insert.