WaterCooled. Inverter Water Cooled Air Conditioners.

Similar documents
york air-conditioning products Residential & VRF News 2015

FULL DC INVERTER SYSTEMS

ECOCIAT. Domestic hot water heat recovery unit

DUCTED AIR CONDITIONING SOLUTIONS

HP switch LP switch Discharge thermo Comp. Surface thermo

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Cooling kw Heating kw

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

LG Electronics AE Company, Commercial Air Conditioning

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

CRAC Precision climate control units for data centres

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Chilled Water Fan Coil Unit

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

HVAC Systems: Overview

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

KONRAD. Hybrid Fancoil Series

SECTION HEAT PUMPS

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

catalog Single Package Vertical Air Conditioners and Heat Pumps

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Chilled Water Precision Air Conditioner For Critical Application

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

HEAVY DUTY STORAGE GAS

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Cool Design for Homes and Offices

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

FTQ. Daikin Inverter Ducted Heat Pump

Unico Inverter. Unique and efficient.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

MAC-120HE-01 Air-Cooled Chiller

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Under sill units. Type FSL-B-ZAS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

marine/bespoke split applications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Condensing unit type EPSILON-ECHOS LE Technical information manual

Versati Air to Water Heat Pump

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

A Cover HVAC ENERGY EFFICIENT

Engineering Specifications

FTXS. Wall Mount Heat Pump or Cooling Only

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Air Conditioners Technical Data

RPV - RP - RA air handling units

TWE+TTA TWE+TWA T.R.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Inverter Air Conditioning for Light Commercial Use

squrboxbox heat recovery squrboxbox I technical information

SECTION AIR CONDITIONING UNIT

TRI-CAPACITY CHANGING THE GAME FOR COMMERCIAL AIR CONDITIONING

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

technology innovation, comfort for your home. The perfect blend of

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

DESIGN & TECHNICAL MANUAL

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

HEATING, VENTILATION & AIR CONDITIONING

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Refrigeration Compressed Air Dryer Buran Ultrapulse

PLUG and PLAY VRV Connection

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

Samsung Room Air Conditioning

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

GREE, MAKING BETTER AIR CONDITIONERS

Single Package Vertical Air Conditioners. Vert-I-Pak

Electric Flow Boiler

Glossary of Heating, Ventilation and Air Conditioning Terms

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

FBQ. DC Duct Heat Pump or Cooling Only

Product catalog UNT-PRC011-E4

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Commercial Gas Furnace Upflow

Lesson 36 Selection Of Air Conditioning Systems

Transcription:

WaterCooled Inverter Water Cooled Air Conditioners

Dunnair Quality Engineering Solutions The name Dunnair is synonymous with high quality products in the commercial air-conditioning industry. Beginning with Dunn Air Conditioning in 1961 and more recently, Dunnair International and Dunnair Australia, the company continues to be a leading supplier of air-conditioning products for the Australian market. In 1994, the company was acquired by Multistack and renamed Dunnair International. In 2004, Ernest Ugazio acquired the sales and service department of Dunnair. This led to the company being divided into separate entities: Dunnair International and Dunnair Australia, the former focused on Multistack Chiller sales and spare parts; while the latter began design and development of a split ducted and rooftop packaged range. The Inverter water cooled air conditioners shown in this brochure are part of Dunnair s range of high quality units for every application. Dunnair has also become the first choice when individual engineering solutions are required. Fast-moving and responsive, Dunnair supplies made-to-measure HVAC solutions to a growing number of high profile developments across Australia. Dunnair research and development plus a strict quality control program have been fundamental to our growth, success and reputation. Dunnair units are manufactured in accordance with strict quality control standards and are MEPS rated and developed for Australian conditions. Range: Dunnair s two modern factories manufacture 16 separate product lines and some 600 different models. Dunnair can supply most products the HVAC industry requires. This new product line of Inverter water cooled air conditioners is proof that the company is working continuously to improve its product range and efficiency. Specialised Solutions: Dunnair will engineer and manufacture equipment to suit the application and building design. We will design and manufacture as required for the building, mining, transport and maritime industry. We employ mechanical engineers in all sales offices to support designers in achieving their requirements. Our promise to our clients is Tell us what you need and we will work with you to deliver it. With its head office in Melbourne, Dunnair has offices in New South Wales, Queensland, South Australia, Western Australia and Tasmania. Established 1961, Dunnair maintains a dedicated engineering and sales support staff waiting to assist you with technical and product information and provide valuable solutions for your project. Dunnair will design, build and deliver HVAC equipment to meet the most stringent specifications and difficult applications.

>>General The Dunnair Inverter reverse-cycle packaged series provides a higher efficiency of our already efficient standard WPR packaged range, which are designed specifically to provide all-year round comfort to room occupants. Our units are efficient, designed to be operated by occupiers via individual control systems, avoiding costly centralised plant. The inverter water-cooled range is an ideal choice for projects that need a large number of units such as high-rise offices or hotel buildings - where different zone temperature are required throughout the building. Our inverter technology will save power, take less time to reach desired temperature and oscillate closer to the desired temperature over fixed speed models. Soft start ensures lower start up current and associated lower energy consumption.this market leading product now provides a viable alternative to VRF systems. Our comprehensive range of inverter units from 4kW to 25kW allows all types of application providing a lower running cost throughout the entire life cycle of the unit. >>Features 1. DC Inverter Compressor TEMPERATURE 2. Electronic Expansion Valve 3. EC Fan (Option) 4. Tube In Tube Heat Exchanger 5. Reduced unit height 6. Stainless steel drip tray 7. BMS compatible (Modbus) 8. Blu-fin anti-corrosion coil protection 9. Powder coated galvanised steal panels 10. Pre-charged with R410a 11. Internal thermal acoustic insulation 12. Excellent C.O.P & E.E.R rating 13. external static pressure SET POINT Inverter Air Conditioner Non-Inverter Air Conditioner TIME 03

>>General The DUNNAIR DWAI Series represents a range of ducted, water cooled, packaged air conditioners designed to provide year round comfort to room occupiers. The DWAI units are ideal for multi-unit installations such as high-rise offices or hotel buildings, where the flexibility of individual zone control is required. Compact and reliable, these units can be installed above ceilings, or in other concealed spaces, saving valuable floor space and providing conditioned air direct to required locations. DWAI Series units are designed to be used with simple duct layouts. To take maximum advantage of this feature, units should be located as close to the space to be air conditioned as acoustic criteria allows. Multiple small units, utilizing minimal duct lengths, prove more economical than a single large central ducted unit. Designed also to suit different climates, the DWAI units are available in Reverse cycle. In office buildings, a DWAI unit system can provide the ideal off-peak system for occupied areas when the main system is not running, e.g. night time, weekends, holidays. DWAI unit systems can be designed to provide owner occupiers with individual control, thus avoiding large central plant room areas, e.g. in apartment buildings. >>Features Refrigerants Each unit is factory charged with refrigerant R410A, which has zero Ozone depletion potential. Air Coil Die formed plate type aluminium fins mechanically bonded to high efficiency inner grooved copper tubes. Water Coil Copper tube in tube type with refrigerant flow in the outside tube. Designed to a maximum water pressure of 1500kPa (215psi). Fans Forward curved double inlet fans in involute scrolls and fitted directly to a mounted motor. Speed tappings allow airflow selection to match external duct pressure. Construction Galvanised steel construction, closed cell foam lined compressor and fan compartments, with an insulated and powder coated drain tray for complete moisture protection. The drain tray is easily removed for inspection and cleaning. Air Filter (Standard) A filter integrated return air spigot is available on all models. The filter is a washable polypropylene net type. Care should be taken, when locating each unit, that enough space is provided to enable the one-piece filter to be withdrawn to its full length from either side of the unit. Compressor DWAI units use hermetically sealed high efficiency Toshiba inverter compressors. Insulation DWAI units are well insulated to minimise condensation and attenuate noise. 04 Serving the HVAC industry since 1961

>>Optional Features >>Unit Protection As an active market player in the commercial air conditioning industry, we understand that every project is unique. Standard manufactured units may not meet the requirements of your system design. Dunnair always welcome enquiries for special air conditioning equipment. Available options are listed below: Stainless steel drip tray 50mm thick insulation VSD on supply air fan er ESP (external static pressure) up to 500pa 2 stages or more depending on size of the unit Belt drive instead of direct drive fan All copper coils BMS output/input connection. Dunnair specialises in manufacturing equipment to suit the applications. Units are fitted with a high pressure lockout protection. These protect the unit in the event of either water flow failure in cooling mode or fan failure in heating mode. Sensors protect against low air coil temperature and loss of refrigerant. Units include an anti-rapid cycle timer for compressor on/off protection. DWAI reverse cycle units also have a low refrigerant temperature safety thermostat to protect against icing up of the water within the unit s condenser on heating mode and a pump flow verification relay to protect individual units from a loss of water flow. Convenient lockout contactor resetting is simply achieved by turning the power to the unit off and then on again, avoiding the need to gain access to each unit if the cause is failure of central water supply. Lockout protection will also reset when the thermostat switches on, or is switched to the dead zone. Each compressor has internal overload protection. The DWAI reverse cycle version has a low refrigerant temperature limit switch and a reverse cycle valve.. 05

>>Noise Prevention Spring Mounting System Flexible Connection 1m Air Filter Flexible Connection 1m Unit 25mm Insulation Lined Supply Air Duct Neoprene Vibration Isolation 25mm Insulation Lined Return Air Duct Safety S Tray P Tray Trap 1. Ensure distance between two units is at least 2.5m. 2. The air velocity in the supply air duct should not be greater than 3 3.5m/sec. 3. The air velocity in the return air duct should not greater than 2 5m/sec. 4. Duct insulation should be at minimum of 25mm and be perforated aluminium lined for better sound absorption. 5. The minimum length of straight supply air duct between T pieces or 90 bends must be at least 5 times the diameter of the duct. 6. Dampers and grilles should not be installed closer than 3m from the air supply spigot of the unit. 7. Whenever possible insulate the area under the unit with suitable insulation to minimize sound travel downwards through the ceiling. Area to be insulated should be at least twice the size of the base of the unit. 8. The minimum length of the return air duct should be at least 2m. If this is not possible, introduce a bend in the duct design or install a sound attenuator duct. 9. Always install unit above unoccupied areas e.g. storerooms, toilets etc. 10. Always allow sufficient space around the unit for service. Dunnair units require a minimum 500mm free area on all sides. 11. Always install a secondary safety tray under the fan coil unit (supplied by mecharical contactor) 12. Install P Trap to condensate drain outlet on fan coil unit. 13. Make sure drain has gradient to tundish 06 Serving the HVAC industry since 1961

>>Condensate Drain Drain Connections Clear Plastic Tube To Water Flow H=Air Static Pressure/10+20(mm) 50 100mm Drain To Tundish >>Water Supply and Return 6mm Air Vent Ball Valve Union AHU Ball Valve 2 Way Control Value and Balancing Valve Drain to Tundish (Optional) Ball Valve 6mm Air Vent Union Ball Valve (Optional) AHU Ball Valve 3 Way Control Value and Balancing Valve Drain to Tundish (Optional) 07

Inverter Water Cooled - Packaged Units (Horizontal) >>Inverter Water Cooled Packaged Unit - Dimensional Drawing DWAI-04 HAB DWAI-06 HAB DWAI-08 HAB DWAI-10 HAB DWAI-12 HAB Overall Size Depth (mm) 445 445 555 555 555 Width (mm) 1127 1127 1430 1430 1430 Height (mm) 360 360 470 470 470 Weight (kg) 63 65 106 112 115 Spigot Sizes Return Air Spigot (mm) 450 x 300 450 x 300 888 x 400 888 x 400 888 x 400 Supply Air Spigot (mm) 304 x 153 304 x 153 430 x 203 430 x 203 430 x 203 * DWAI - 16HAB, DWAI - 20 HAB, DWAI - 25 HAB are available on request. W D H H Front view Side view W D H W Top view Rear view 08 Serving the HVAC industry since 1961

Packaged - Horizontal Units >>Inverter Water Cooled Packaged Unit - Specifications Overview DWAI- 04 HAB DWAI- 06 HAB DWAI- 08 HAB DWAI- 10 HAB DWAI- 12 HAB DWAI- 16 HAB DWAI- 20 HAB DWAI- 25 HAB Total Cooling Capacity* (kw) 4.1 (1.2-4.9) 6.2 (1.8-7.4) 8.0 (2.4-8.8) 9.8 (2.9-10.8) 11.5 (2.6-12.0) 15.0 (5.4-17.0) 20.0 (6.7-21.2) 25.0 (8.3-26.5) Sensible Cooling Capacity (kw) 3.4 4.9 6.6 8.2 9.9 12.6 17.5 19.8 Heating Capacity** (kw) 4.3 (1.2-5.0) 6.1 (1.5-7.2) 8.3 (2.1-9.2) 10.1 (2.3-11.0) 11.7 (2.6-12.2) 11.2 (7.1-17.2) 15.0 (9.2-20.3) 20.0 (12.2-26.6) Rated Airflow (L/S) 236 260 434 445 528 780 1000 1150 Sound Pressure Level # 33.4 38.9 43.4 45.5 47.8 57.0 59.0 61.0 External Static Pressure (Pa) 100 120 150 150 150 150 150 180 Power 240V/50Hz/1Ph 415V/50Hz/3Ph Electrical Input (Cooling) (kw) 1.08 1.62 2.19 2.6 3.1 4.2 5.5 6.9 Nominal Max Current (A) 4.2 6.7 9.5 10.9 13.0 12.6 15.7 19.7 E.E.R (Cooling) 3.80 3.82 3.64 3.77 3.71 3.57 3.64 3.62 Water Flow (L/s) 0.24 0.34 0.47 0.56 0.66 0.8 0.88 1.05 Water Coil Pressure Drop (kpa) 35 35 36 40 44 48 52 55 Water Connections inch 1.0 1.0 1.25 1.25 1.25 1.5 1.5 1.75 mm 25.4 25.4 31.75 31.75 31.75 38.1 38.1 44.45 Depth 445 445 555 555 555 700 700 700 Dimension mm Width 1127 1127 1430 1430 1430 1650 1650 1650 Height 360 360 470 470 470 700 700 700 Weight kg 63 65 106 112 115 160 185 205 * Entering air temp. @27/19 C and enter water temp. @30 C ** Entering air temp. @21DB and enter water temp. @20 C. # 1m from sound source with 1m insulated duct Units are being reviewed 09

>> Horizontal Water Cooled R410A >>Water source heat pump unit performance correction table Specifications Overview Cooling Capacity Correction Factor Air On ( C, WB) Total Cooling Capacity Sensible Cooling Capacity, Air On ( C,DB) 21.0 24.0 27.0 29.0 32.0 15.0 0.88 0.86 1.02 * * * 17.0 0.95 0.71 0.90 1.03 * * 19.0 1.00 0.56 0.77 1.00 1.17 * 21.0 1.06 0.60 0.84 1.02 1.22 23.0 1.12 0.43 0.59 0.78 0.99 Note: * means Sensible cooling capacity equals to Total cooling capacity Air on : Max 32 C (DB),Min 20 C (DB) / 15 C (WB); EWT : Max 40 C, Min 20 C Heating Capacity Correction Factor Air On ( C,DB) Heating Capacity Heat Absorption Capacity Input Power 16.0 1.02 1.04 0.92 18.0 1.01 1.02 0.97 21.0 1.00 1.00 1.00 24.0 0.98 0.96 1.07 27.0 0.97 0.93 1.14 Note: Air on : Max 28 C (DB),Min 15 C (DB) / 15 C (WB); EWT : Max 40 C, Min 15 C Airflow Correction Factor Nominal Airflow % Total Cooling Capacity Sensible Cooling Capacity Heating Capacity 80 0.95 0.87 0.97 90 0.98 0.94 0.99 100 1.00 1.00 1.00 110 1.02 1.06 1.01 120 1.04 1.11 1.03 10 Serving the HVAC industry since 1961

>>BMS Interface Module Net Board Code Switch Third party BMCS system Thermostat A/C Unit PCB >>Thermostat > Heat/Auto mode (Reverse Cycle Systems only). > Auto/// fan speed selection. > Temperature setting range from 16 C to 30 C. > Room temperature display. > Real time clock. 11

Packaged - Horizontal Units >>Inverter Water Cooled Packaged Unit - Fan Curves Performance DWAI-04 HAB DWAI-06 HAB External Static Pressure Pascal s 160 120 80 40 External Static Pressure Pascal s 160 120 80 40 Includes Dry Coil Static 196 216 236 256 276 Includes Dry Coil Stati c 220 240 260 280 300 DWAI-08 HAB DWAI-10 HAB 240 240 External Static Pressure Pascal s 180 120 60 External Static Pressure Pascals 180 120 60 Includes Dry Coil Static 354 394 434 474 514 Includes Dry Coil Stati c 365 405 445 485 525 DWAI-12 HAB * DWAI - 16HAB, DWAI - 20 HAB, DWAI - 25 HAB are available on request. 240 External Static Pressure Pascal s 180 120 60 Includes Dry Coil Stati c 448 488 528 568 608 12 Serving the HVAC industry since 1961

Packaged - Horizontal Units >>Inverter Water Cooled Packaged Unit - Sound Pressure Curves DWAI-04 HAB A Class: 33.4dB 64 37.8 125 33.7 250 33.2 500 28.9 1000 27.5 2000 24.9 4000 18.3 8000 12.1 0dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI-06 HAB A Class: 38.9dB Frequency (Hz) SPL(dB) 64 45.2 125 40.4 250 39.7 500 34.5 1000 32.2 2000 28.4 4000 25.2 8000 16.3 0dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI-08 HAB A Class: 43.4dB 64 48.5 125 47.1 250 40.3 500 35.5 1000 33.8 2000 30.6 4000 26.4 8000 18.5 0dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 13

Packaged - Horizontal Units >>Inverter Water Cooled Packaged Unit - Sound Pressure Curves DWAI-10 HAB A Class: 45.5dB 64 51.8 125 48.5 250 42.6 500 38.5 1000 34.6 2000 31.5 4000 26.8 8000 19.5 0dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI-12 HAB A Class: 47.8dB 64 52.6 125 48.1 250 42.6 500 38.1 1000 35.8 2000 32.4 4000 26.9 8000 18.6 0dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz * DWAI - 16HAB, DWAI - 20 HAB, DWAI - 25 HAB are available on request. # 1m from sound source with 1m insulated duct 14 Serving the HVAC industry since 1961

Inverter Water Cooled - Packaged Units (Vertical) >>Inverter Water Cooled Packaged Unit - Dimensional Drawing DWAI4L DWAI6L DWAI8L Overall Size Depth (mm) 540 540 575 Width (mm) 520 520 586 Height (mm) 1290 1290 1450 Weight (kg) 85 90 105 Spigot Sizes (mm) Return Air Spigot 380 x 350 380 x 350 420 x 611 Supply Air Spigot 304 x 153 304 x 153 358x 203 DWAI10L DWAI12L Overall Size Depth (mm) 575 575 Width (mm) 586 646 Height (mm) 1450 1549 Weight (kg) 110 125 Spigot Sizes (mm) Return Air Spigot 420 x 611 480x 711 Supply Air Spigot 358x 203 358 x 203 W S/A D Access Panel Filter Water Out Water In H H R/A D Drain Connections HP LP Access Panel W Top view Front view Side view 15

Packaged - Vertical Units >>Inverter Water Cooled Packaged Unit - Specifications Overview DWAI4L DWAI6L DWAI8L DWAI10L DWAI12L Total Cooling Capacity* (kw) 4.1 6.2 8.3 9.5 11.5 Sensible Cooling Capacity (kw) 3.4 5.2 6.6 7.6 9 Heating Capacity** (kw) 4.3 6 7.8 10.1 11.7 Rated 236 258 444 444 527 Sound Pressure Level # (db) 42 45 47 47 47 External Static Pressure (Pa) 100 120 150 150 160 Power 240V/50Hz/1Ph Electrical Input (Cooling) (kw) 1.12 1.63 2.2 2.65 3.1 Nominal Max Current (A) 7.5 11 13 15 16 E.E.R (Cooling) 3.6 3.8 3.8 3.6 3.7 Water Flow (L/s) 0.24 0.34 0.39 0.5 0.66 Water Coil Pressure Drop (kpa) 38 38 40 40 40 Water Connections inch 3/4 3/4 1 1 1 mm 19.05 19.05 25.4 25.4 25.4 Depth 540 540 575 575 575 Dimension mm Width 520 520 586 586 646 Height 1290 1290 1450 1450 1549 Weight Kg 85 90 105 110 125 * Entering air temp. @27/19 C and enter water temp. @30 C ** Entering air temp. @21DB and enter water temp. @20 C. # 1m from sound source with 1m insulated duct 16 Serving the HVAC industry since 1961

Packaged - Vertical Units >>Inverter Water Cooled Packaged Unit - Fan Curves Performance DWAI4L DWAI6L External Static Pressure Pascal s 160 120 80 40 External Static Pressure Pascals 180 140 100 80 Coil Static 196 216 236 256 276 Includes Dry Coil Stati c 218 238 258 278 298 DWAI8L DWAI10L External Static Pressure Pascals 240 180 120 60 External Static Pressure Pascals 240 180 120 60 Includes Dry Coil Stati c 364 404 444 484 524 Includes Dry Coil Stati c 364 404 444 484 524 DWAI12L 240 External Static Pressure Pascal s 180 120 60 Includes Dry Coil Stati c 448 488 528 568 608 17

Packaged - Vertical Units >>Inverter Water Cooled Packaged Unit - Sound Pressure Curves DWAI4L A Class: 42.5dB 64 36.8 125 43.0 250 42.4 500 39.4 1000 37.2 2000 35.6 4000 27.2 8000 22.3 90dB 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI6L A Class: 45.5dB 64 50.0 125 46.9 250 45.3 500 39.4 1000 38.3 2000 34.9 4000 27.1 8000 22.2 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI8L A Class: 47dB 64 50.6 125 47.1 250 45.0 500 43.1 1000 41.7 2000 36.0 4000 27.9 8000 20.2 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 18 Serving the HVAC industry since 1961

Packaged - Vertical Units >>Inverter Water Cooled Packaged Unit - Sound Pressure Curves DWAI10L A Class: 52dB 64 54.7 125 48.6 250 46.8 500 43.4 1000 41.8 2000 39.8 4000 32.6 8000 26.2 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz DWAI10L A Class: 54dB 64 57.9 125 55.1 250 54.2 500 45.8 1000 41.6 2000 38.1 4000 28.1 8000 22.6 64Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz # 1m from sound source with 1m insulated duct 19

Inverter Water Cooled - Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Dimensional Drawing DWAIS4 DWAIS6 DWAIS8 DWAIS10 DWAIS12 Overall Size WxDxH (mm) Indoor 920x570x270 920x570x270 920x520x270 1140x660x270 1200x750x300 Outdoor 640x451x385 640x451x385 670x550x520 670x550x520 670x550x520 Weight (Kg) Indoor 25 25 29 36 43 Outdoor 45 48 53 58 62 Spigot Sizes Return Air Spigot 787x233 787x233 1065x265 1065x265 1065x265 Supply Air Spigot 713x178 713x178 965x203 965x203 965x203 Indoor W Outdoor W D Front view H H H W Front view W Side view Top view D D Side view D H Top view 20 Serving the HVAC industry since 1961

Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Specifications Overview DWAIS4 DWAIS6 DWAIS8 DWAIS10 DWAIS12 Total Cooling Capacity*(kW) 4.3 6.2 8.0 9.8 11.4 Sensible Cooling Capacity (kw) 3.3 4.2 6.6 8.2 8.4 Heating Capacity** (kw) 5.2 7.1 8.7 11.2 13.2 Rated 252 327 370 470 540 Sound Pressure Level db(a) Indoor 30.7 31.4 33.6 35.4 36.3 Outdoor 33.4 34.4 46.2 48.2 49.2 External Static Pressure (Pa) 90 90 160 160 170 Power 240V.1 Ph.50Hz Electrical Input (Cooling) (kw) 1.14 1.62 2.17 2.64 3.08 Nominal Max Current (A) 4.84 7.1 13 16 16 E.E.R (Cooling) 3.77 3.82 3.69 3.71 3.70 Water Flow (L/s) 0.29 0.41 0.40 0.5 0.52 Water Coil Pressure Drop (kpa) 35 35 36 40 45 Water Connections Dimension mm WxDxH Weight Kg inch 0.75 0.75 1.25 1.25 1.25 mm 19.05 19.05 31.75 31.75 31.75 Indoor 920x570x270 920x570x270 920x520x270 1140x660x270 1200x750x300 Outdoor 640x451x385 640x451x385 670x550x520 670x550x520 670x550x520 Indoor 25 25 29 36 43 Outdoor 45 48 53 58 62 * Entering air temp. @27/19 C and enter water temp. @30 C ** Entering air temp. @21DB and enter water temp. @20 C. # 1m from sound source with 1m insulated duct 21

Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Fan Curves Performance DWAIS4 DWAIS6 External Static Pressure Pascal s 160 120 80 40 External Static Pressure Pascal s 180 140 100 80 196 216 236 256 276 218 238 258 278 298 DWAIS8 DWAIS10 240 240 External Static Pressur e Pascals 180 120 60 External Static Pressure Pascals 180 120 60 Includes Dr y Coil Static 364 404 444 484 524 364 404 444 484 524 DWAIS12 240 External Static Pressure Pascal s 180 120 60 448 488 528 568 608 22 Serving the HVAC industry since 1961

Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Sound Pressure Curves DWAIS4 Indoor A Class: 30.7dB 64 32.2 125 30.7 250 27.3 500 23.2 1000 21.8 2000 20.7 4000 13.1 8000 10.8 Outdoor A Class: 33.4dB 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 64 37.4 125 33.4 250 32.5 500 29.5 1000 27.2 2000 26.4 4000 17.2 8000 12.3 DWAIS6 Indoor A Class: 31.4dB 64 33.2 125 31.4 250 28.3 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 500 24.6 1000 23.4 2000 22.4 4000 13.2 8000 11.3 Outdoor A Class: 34.4dB 64 38.2 125 34.4 250 33.5 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 500 29.5 1000 28.2 2000 27.4 4000 18.2 8000 12.3 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 23

Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Sound Pressure Curves DWAIS8 Indoor A Class: 46.2dB 64 49.2 125 46.2 250 41.5 500 35.1 1000 33.2 2000 31.4 4000 26.2 8000 18.3 Outdoor A Class: 33.6dB 64 36.3 125 33.6 250 31.5 500 27.8 1000 25.5 2000 23.7 4000 16.8 8000 13.1 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz DWAIS10 Indoor A Class: 48.2dB 64 52.4 125 48.2 250 43.5 500 37.1 1000 35.2 2000 33.4 4000 28.2 8000 19.2 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 24 Serving the HVAC industry since 1961

Split Ducted Units >>Inverter Water Cooled Split Ducted Unit - Sound Pressure Curves Outdoor A Class: 35.4dB 64 38.3 125 35.4 250 33.3 500 29.4 1000 27.3 2000 25.3 4000 17.8 8000 14.2 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz DWAIS12 Indoor A Class: 49.2dB 64 53.2 125 49.2 250 43.5 500 37.1 1000 35.2 2000 33.4 4000 28.2 8000 19.3 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Outdoor A Class: 36.3dB 64 39.4 125 36.3 250 34.5 500 30.5 1000 28.2 2000 26.4 4000 19.2 8000 14.3 64Hz 125Hz 250Hz 500Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz # 1m from sound source with 1m insulated duct 25

>>Wiring Diagram Single Phase DWAI-04 HAB - DWAI-12 HAB DWAI4L - DWAI12L 26 Serving the HVAC industry since 1961

>>Wiring Diagram Split Ducted Units DWAIS4 - DWAIS12 Note: Water and air flow switches supplied by installer. 27

DUNNAIR (Aust) Pty Ltd Head Office: 140 Bernard Street, Cheltenham VIC 3192 p 03 8586 8200 f 03 8586 8201 e salesaust@dunnair.com.au w Dunnair New South Wales: p 02 9674 1577 f 02 9674 1588 e salesnsw@dunnair.com.au Dunnair SA & NT: p 08 8240 2888 f 08 8240 2777 e salessa@dunnair.com.au Dunnair Western Australia: p 08 9418 2444 f 08 9418 2100 e saleswa@dunnair.com.au Dunnair Victoria: p 03 9558 7001 f 03 9551 1644 e salesvic@dunnair.com.au Dunnair Queensland: p 07 3890 8796 f 07 3890 8642 e salesqld@dunnair.com.au Dunnair Tasmania: m 0418 756 643 p 03 6425 3531 e salestas@dunnair.com.au New Zealand (agent): p +64 9 582 1012 e salesnz@dunnair.com.au Shanghai: P: +86 158 8806 3726 E: salesshh-china@dunnair.com.au Contact: Ms Shelly Xiong Thailand: P: +66 8 7074 2965 E: salesth@dunnair.com.au Contact: Mr Giuseppe Di Martino Contact: Mr Jeff He Dunnair (Aust) Pty Ltd supports a policy of continuous product improvement. Therefore specification and designs are subject to change without prior notice. Dunnair (Aust) Pty Ltd accepts no responsibility for possible errors in Catalogues, brochures and other printed material. 1115v1