H.E.P.A. Air Cleaner

Similar documents
Cooktop Low-Profile Ventilation Hoods

Installation Instructions

Installation Instructions

How To Install A Perfect 16 Id Series Filter System

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Cooling Capacity CFM in. w.c. (125 Pa)

F50F Duct Mounted Electronic Air Cleaner

Ceiling Fan Installation Instructions

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

HEAT WAVE DUCT KIT KIT #

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Generator Transfer Switch Model # HTS15-AUTO

UV100A Ultraviolet Air Treatment System

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Accessory Manual Ventilation Section Model Comfort Circle

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

MCR1900 Media Converter 19-Slot Chassis

Troubleshooting Guide for Dispenser Model #900172

Installer Guide smart connect

Installation Instructions

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Doorbell Intercom Security System

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Ceiling Mount Air Handler Manual

INFRARED QUARTZ WALL HEATER

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

REMOVE AND REPLACE AIR CONDITIONER. 170 Popular Dodge REMOVAL: AIR CONDITIONING Section 4 Page 1

20 GALLON WET DRY VACUUM

Installation Instructions

Dehumidifier Users manual. For Models: DH45S DH65S

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Control Box Wiring For PRSstandard Tool

French Door Refrigerator E23BC78IPS professional series

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

Service Guide. Gateway M275

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

INSTALLER S & OWNER S MANUAL

Commercial Gas Furnace Upflow

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

Serial ATA to Serial ATA

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Copyright Puradigm, LLC HVAC Owner s Manual

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

USER S MANUAL HSC-24A

How to Maintain an Air Conditioner

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Wall-Mounting your HP computer. User Guide

F9MXE. Product Specifications

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

TS93 EMR T/PT/TDE. Surface applied door closer

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

ELECTRIC CONVECTION BUILT-IN OVEN

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Powers Controls TH 192 S Single Temperature Room Thermostat

How To Install An Evaporator Coil

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

FOXAIR 60/50 ALL MODELS

HP 16/18-Port Cable Management Kit Installation Guide

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Installation Instructions

Central Air Conditioner

CEILING CASSETTE FAN COIL UNIT

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATION MANUAL

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Installation Instructions

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

ELECTRIC KNIFE SHARPENER

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

ATS Overhead Table Shelf System INSTRUCTION MANUAL

16/32 Channel 1U Rack Mount CCTV Power Supply

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

Anthro Tablet Charging Cabinets

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

Line to Refrigerator Ice/Water Dispenser

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

GENUINE PARTS INSTALLATION INSTRUCTIONS

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Transcription:

Installation Operation Maintenance WHOLE HOUSE HEPA FILTRATION SYSTEMS H.E.P.A. Air Cleaner WHOLE HOUSE HEPA FILTRATION SYSTEM 300CFM Pictured here with the optional collar mount kit For residential installation only

Table of contents 7 L i m i t e d years W a r r a n t y Manufacturer Warranty You benefit from a limited 7 year warranty on the motorized impeller and a 5 year limited warranty against manufacturing defects on other components. The limited warranty covers normal usage. It does not apply to malfunctions or failures as a result of improper installation, abuse, mishandling or misapplication or any other circumstances outside the manufacturer s control or consent. Warranty from the manufacturer is for parts only, labor and shipping of the product is not covered under warranty. Warranty doesn t cover in any way or form the replaceable Pre-Filter, Carbon Filter or HEPA Filter. 1.Getting Started GENERAL INFORMATION 1.1 Unpacking and inspection 2 1.2 Technical data 3 2.Installation Guide INFORMATION FOR INSTALLERS PAGE 2.1 Planning the installation 4 2.2 Type of installation: Return to Return 4 2.3 Type of installation: Stand-Alone 5 2.4 Installing the unit 6 3.Owner s Operation Guide INFORMATION FOR THE HOMEOWNER PAGE 3.1 General Operating Information 9 4. Maintenance Guide GENERAL MAINTENANCE INFORMATION PAGE PAGE 4.1 Changing filters 10 4.2 Cleaning unit 10 4.3 Auxiliary relay control module 11 Box Content Includes: 1.1.Unpacking and inspection Whole House H.E.P.A. 300CFM Power cord, 5 FT Plenum seal, 7.5 FT Screws, (16) 8 x 32 x 1/2 Template PAGE 2

1.2. Technical Data Specifications Dimensions and Clearance installation Return Air Plenum Installation Front View Side View - Clearance Back View Filtration Stage 1 & 2 Filtration Stage 3 Prefilter with Carbon (ARK564) HEPA filter (RHF562) Weight 28 lbs (12.7 kg) Plenum Mount Port Openings 16 x 3.5 (406mm x89mm) Collar Mount Port Openings 8 (203mm) Round* Installation type Plenum,Wall* or Floor*Mounted Electrical Supply 120 VAC @ 60 Hz Power Consumption 134 W Certification CCSA US Air flow data 220-300 CF.M. * Installation requires kit No.CMK500 17 (432 mm) 11.587 (294.5 mm) Stage 1 Stage 2 Stage 3 12 (305 mm) 22 (559 mm) 17 (432mm) IMPORTANT INFORMATION The manufacturer reserves the right to modify a product, without prior notice, whether in design, color or specifications, in order to offer at all times a quality product that is highly competitive. Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. Return Air Plenum and Stand Alone Installations * With Collar Mount Kit Front View Side View - Clearance Side View Stage 1 Stage 2 Stage 3 22 (559 mm) 17 (432 mm) 11.587 (294.5 mm) 12 (305 mm) 13 (330mm) PAGE 3

Installation 2. Information for the Installer Special Consideration For integrated system installation Verify clearance on the ductwork to mount the unit using the Forced Air heating/cooling system Minimum clearance requirements for maintenance and service Electrical power requirements Interaction between the HEPA filter unit and other mechanical devices. 2.1 Planning the Installation The Whole House HEPA unit is a versatile appliance with multiple installations configuration. It is recommended to take your time in planning the installation. Several Installations are illustrated herein for Whole House filtration applications: Return to return integrated with the forced air heating/cooling system. Central draw points using dedicated duct system Consult the manufacturer for other special applications. Ducting Flair System installation The Whole House HEPA Filtration system is designed to install directly onto the return air plenum of the forced air heating/cooling system. Choosing this type of installation eliminates the need to externally duct the HEPA filter unit to the plenum system. If you choose this type of installation, it is recommended that you run the fan on your forced air system continuously to maximize its cleaning ability. TIPS to installer The Whole House HEPA Filtration system does not replace the filter from the forced air heating/cooling system. Regular maintenance of this filter is necessary to permit the good operation of the forced air heating/cooling system. Return Air Plenum 2.2 Type of Installation: Return to Return Integrated System Ducting Flair System (Hepa Mounted on Duct) To living space Return Air Plenum Optional Collar System (Hepa Mounted on Wall) To living space Optional collar system installation Using kit no. CMK500 the Whole House HEPA Filtration system can be converted to use 8 inch round collars for application requiring ducting. The kit includes two, 8 inch round collars, two mounting brackets for wall or floor mounting, installation guide and fasteners. Forced AirHeating/CoolingSystem Forced AirHeating/CoolingSystem INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSION- AL. Consult your HVAC product manufacturer if the usage of this product will affect the performance of your forced air heating / cooling system. PAGE 4

Installation 2.3 Types of Installation: Stand-Alone Stand Alone Attic Installation Ideal for homes without a forced air heating / cooling system. Allows for air filtration and circulation throughout the home. HEPA system must be operated continuously whenever a part or all the system is located in an unconditioned space to avoid condensation in the ductwork below freezing (0 C, 32 F). Stand Alone Basement Installation Ducting will usually consist of one return with grille from one side of the home, and one supply with grille at the opposite end of the home. PAGE 5

Installation 2.4 Installing the unit Tools required Phillips #2 or Robertson #1 screwdriver 3/32 drill bit Tin snips or metal shear Power Drill Step by step Installation Steps involved in the preparation of the plenum mount system are as followed: Step 1: Preparing return air plenum Find a location that satisfies both service and maintenance requirements and proceed to cut holes as illustrated below. Step 2: Preparing ducting flairs Remove the door and filters and proceed to cut the insulation as illustrated below. Location Return side connections is to be installed after the last branch on the return air plenum and minimum 2 linear ft distance from furnace. figure2.2a- Cut the insulation along the inside edge of both inlet and outlet ports to remove the insulation from the port openings. A 5-ft power cord is supplied with the unit. If not available a 120VAC outlet needs to be supplied. figure 2.1a - Tape template to return air plenum. Cut opening with metal shears and predrill for the securing screws. Note: Refer to the Owner s Operation Guide (p.9) for details on how to remove the unit s door and filters figure 2.2b -One cut permits the clean removal of the insulation piece. figure 2.1b - Remove template. figure 2.2c -The unit should look like this when the foam piece is removed. PAGE 6

2.4 Installing the unit (Continued) Installation Tips to installer Interlocking the HEPA filtration unit with the forced air heating / cooling system is possible using an auxiliary relay. Refer to page 11 of this guide for example. Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. Step 2:(Continued) Cut the four metal tabs to release the mounting flairs for the inlet and outlet ports. figure 2.2d Step 2:(Continued) figure 2.2h - Apply plenum seal tape all around both openings on the back of the unit. figure 2.2e figure 2.2i figure 2.2f figure 2.2g figure 2.2j- Bend tabs outward approximately 90 degrees. PAGE 7

Installation 2.4 Installing the unit (Continued) Tips to installer It is recommended that the filtration unit have a devoted receptacle with 115V. It is not recommended to connect unit with an extension cord. If no receptacle is available please call an electrical contractor to have one installed. Step 3: Mount Hepa Step 3: (Continued) MAKE SURE TO INSTALL FILTERACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is located on the unit s motor plate. figure2.3a - Align unit into place. figure 2.3c - Install unit as usual using all supplied fastening hardware. Step 4: Finishing Stage 1&2: Pre-Filter & Carbon figure 2.3b - Unfold the ducting flairs completly to sandwich the return air plenum between the ducting flair and the filtration unit. Stage 3: HEPA Filter figure 2.4a - Remove protective plastic covers from all filters and replace them in their proper location (Stage 1, 2 and 3). figure 2.4b - Replace door and insert power cord into the receptacle of the filter units and the other end into wall outlet. PAGE 8

Owner s Operation 3. General Operating Information Door Switch Mode Selector II I Operations MaximumFiltration Normal Filtration Function The Whole House HEPA system is comprised of a ventilator, speed selection switch, 3 stages of filtration and the cabinet enclosure system. The ventilator pulls air through the pre-filter and pushes the same air threw the impregnated carbon pad for odor control and finally the last stage of filtration is the HEPA filter which removes 99.97% of particles 0.3µm in size. Operation Mode Options The unit features two speeds of operation for your convenience. The speed selection switch is located on the front of the motor assembly. At lowest speed the unit will provide 220 CFM of clean air while at highest speed, the unit will provide 300 CFM of clean air. It is recommended that the unit be operated on highest speed at all times to maximize the benefits of the HEPA filtration system. If for some reason the filtration needs are not as important then one might operate the unit at low speed. An access door is provided at the front of the unit to permit access to the filters and speed selection switch. Opening the latch on the right side of the unit will permit the door to swing open. A safety door interlock switch cuts the power to the motors for your safety. If needed the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently taping on the bottom edge of the door with the other hand to release the door from its hinges. Recommended Operation The return plenum mount model operates in conjunction with your forced air heating/cooling system. A forced air distribution system continuously circulates the same air inside your home. The whole house HEPA filtration system operates on the principal of bypass filtration, which means that a portion of the air being returned into the furnace is filtered on each pass. Over time all the air in the home gets cleaned. It is recommended that the furnace blower be in operation whenever the filtration system is in operation. For stand-alone attic installation, the HEPA filtration system must be operated continuously whenever a part of all the system is located in an unconditionned space to avoid condensation in the ductwork below freezing (32 F,0 C) Maintenance of the unit should be performed at regular interval to keep the benefits of the HEPA filtration unit. PAGE 9

Maintenance 4. General Maintenance Information When should I Service my Unit? service and accessories Detailed maintenance information is located on the front decal on motor plate. PRE-FILTER AND CARBON FILTER Replace filters every 6 months or as needed. HEPA FILTER Replace filter every 1 to 3 years or as needed. Check regularly to maintain maximum performance from your HVAC system. For replacement filters, contact your local HVAC contractor. Note to installer IMPORTANT : ALWAYS UNPLUG UNIT BEFORE SERVICING 4.1 Changing Filters After opening the unit s door, grasp both edges of filter and pull with equal force to slide out the filter. 4.2 Cleaning Once a year or as needed, clean the interior of the unit (Wall and motor plates) using mild non-abrasive soap and water. It is recommended to use products that are environmentally friendly. 4.3 Troubleshooting Troubleshooting Suggestions Unit does not operate Unit operates only on one speed. Unit vibrates Is power cord fully inserted in the unit s connector? Is outlet powered? Is door interlock switch operating? Possible loose wire inside electrical box, contact your local contractor. Check for excessive dust builup or missing balancing weight on the impeller wheel. Kits and Accessories COLLAR MOUNT ADAPTER KIT Part number: CMK500 REPLACEMENT H.E.P.A. FILTER Part number: RHF562 ANNUAL PRE-FILTERS (2) REPLACEMENT KIT Part number: ARK564 REPLACEMENT MOTOR ASSEMBLY Part number: 2RREU25 REPLACEMENT POWER CORD Part number: PWRC60 4.4 Electrical Wiring Diagram Black Blue M Brown 2.5uf Speed Selection 7.5uf Door Interlock L G N PAGE 10

Contact For Technical Support Toll Free: 1-800-578-7873 Mon.-Fri. 9am-5pm ET Wiring the Unit to an ICP80% or 90 % +%Furnace The wiring together of the unit onto an ICP electronic fan control (EFC) board is as simple as 1-2-3. Control boards on different brands of furnaces vary but in principal are all quite similar. Warning: Instructions listed for interlocking the filtration unit to a furnace is an example only. Actual wiring of interlock connection may vary depending on the system Step 1: Turn-off electric power to furnace and use a 120V coil SPST N/O relay. Mount relay to a _ knockout. Step 2: Wire the HOT EAC terminal on the furnace s EFC board to one side of the 120V coil on the relay. Wire the other side of the 120V coil back to a spare common terminal on the EFC board. Step 3: Wire 120V HOT from blower door safety switch (use a spade terminal splitter similar to Johnstone #G21-414) to one side of the open contact on the relay (red wires on L38-180). Wire from the relay to a receptacle you mount in a 2X4 handy-box on the outside of the furnace. Wire the common side of the receptacle to the common terminal on the furnace EFC board. PAGE 11

For Technical support call 1-800-578-7873 Form DYN-206 (03/12)