PyroPure Pure Steam Generators

Similar documents
FLASH TANK ECONOMIZER PRODUCT GUIDE

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Direct steam injection humidifiers

How To Clean Up A Reactor Water Cleanup

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

ASME Packaged Indirect Fired Water Heater

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Features and Benefits

Nirvana. Cycling Refrigerated Dryers

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Commercial Semi-Instantaneous Water Heaters

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Sanitary Type Electronic Flow Switches

Guidelines for Preparing for a Temporary Steam Plant

Desuperheater Online Program Sizing Guidance

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

SIOUX HYBRID WATER HEATER

IGEMA BOILER LEVEL & TDS CONTROLS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Steam System Best Practices Condensate System Piping

steam centre of excellence Steam Boiler System Optimization

Clean Steam in the Pharmaceutical Industry COURSE CONTENT

REGULATORS 175/153 Series

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Corrugated Tubular Heat Exchangers

In-Line Electronic Flow Switches

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

CLEAN STEAM PRODUCTS. CoMBo TEMPERATURE CONTROL PEAK CONDENSATE LOADS

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

In-Line Air Separators

MUELLER FALLING FILM CHILLERS

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Refrigerated Compressed Air Dryers

heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water

Technical Data Manual Model Nos. and pricing: see Price List

Questionnaire Pure Media Systems

Best Practice in Boiler Water Treatment

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

ice 3 FLUID TO FLUID HEAT PUMP

Commercial Gas Water Heaters

I. STEAM GENERATION, BOILER TYPES

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

"EC" Series Electric Humidifier

VAD. Variable Area Desuperheaters

REFRIGERATED COMPRESSED AIR DRYERS

In-Line Electronic Flow Switches

Laboratory & Scientific Line. Horizontal Steam Sterilizers

How To Clean Water From An Ammonia Refrigeration System

Transformer oil cooler ALFA A02

Chapter 2.2: Boilers

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Morrison Bros. Co. General Product Specifications

Electronic Flow Switches

How To Understand Evaporator

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

5.2. Vaporizers - Types and Usage

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Automatic Self-Cleaning Strainers

ECOCIAT. Domestic hot water heat recovery unit

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Characteristics of Evaporators

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

Originators of the Flexible Water Tube design

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Refrigeration Compressed Air Dryer Buran Ultrapulse

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Boiler Preparation, Start-Up and Shutdown

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Light Duty Commercial Electric Water Heater

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Commercial Gas Water Heaters

Commercial Electric Water Heater

Heating Water by Direct Steam Injection

CRAC Precision climate control units for data centres

James M. Pleasants Company

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Explosion-Proof Electric Unit Heaters

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

"ES" Series Electric Humidifier

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Power consumption (kw)

Vacuum drying oven for non-flammable solvents

CE6500 Energy Recovery Ventilator

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

VDL 53 - Vacuum drying oven for flammable solvents

GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System

Transcription:

Paul Mueller Company PyroPure Pure Steam Generators The Mueller PyroPure P7 Series Advantage Mueller PyroPure pure steam generators are capable of producing pyrogen-free pure steam that, when condensed, meets all U.S. Pharmacopoeia (USP) requirements for use in autoclaves, critical area humidification, and routine steamin-place (SIP) sterilization. Feedwater enters the system and flows through two level control valves and then into the tube side of the blowdown cooler. In the blowdown cooler, heat is transferred between the feedwater on the tube side and the blowdown exiting the system through the shell side. Correspondingly, the blowdown exits the system at a lower, safer temperature, and the feedwater enters the system at a higher, more efficient temperature. The heated feedwater flows into the steam separator while filling the lower part of the steam separator, the tube side of the evaporator, and the level indicator assembly to a factory-determined range controlled by level indicator switches. At the same time, utility steam enters the shell side of the evaporator. Latent heat from steam is rejected to the feedwater through the walls of the evaporator tubes. The feedwater is evaporated, and the resulting vapor is propelled from the evaporator into the steam separator where any impurities are removed from the steam by centrifugal force. Pyrogenfree steam exits from the top center of the separator and feeds the pure steam distribution system. Simple Design, Reliable Operation An external evaporator provides improved access for inspection and preventative maintenance on critical o-rings and gaskets. The separation column contains no internal components that require inspection or periodic maintenance. All maintenance (including replacement of critical components) can be performed with only 24" of space on all sides (including the top) of the equipment. Minimal instrumentation is required for equipment operation. Only one control loop is needed which minimizes the calibration required, as well as the potential for downtime. All components are fully drainable, including the feedwater pump. All elastomers in contact with feedwater and product are provided with USP Class VI certifications. ASME BPE certified fittings are used throughout the design. All product contact surfaces are polished to 2 Ra maximum and electropolished. Surfaces in contact with feedwater are polished to 25 Ra maximum. All surfaces in contact with feedwater and product are manufactured from 316/316L stainless steel. 3

System Components Evaporator. The natural circulation design of the PyroPure double-tubesheet evaporator ensures maximum surface wetting, eliminating the hot, dry areas that lead to the stress cr acking associated with other designs. The tube bundle creates a large heat transfer surface that vaporizes feedwater almost instantly to allow the unit to respond to large loads. Mueller PyroPure pure steam generators have a fully drainable external evaporator, eliminating the need for the excess headroom required for evaporator removal with other designs. All surfaces that come into contact with pure vapor or distillate are made of type 316L stainless steel, including the sanitary clamp-type connections and seamless tubes. Blowdown Cooler Assembly. The blowdown cooler assembly serves two functions in making the PyroPure pure steam generator as reliable and efficient as possible: pre-heating the feedwater and cooling blowdown. By transferring heat from blowdown to incoming feedwater, the blowdown cooler serves to preheat the feedwater while cooling wastewater and preventing it from flashing into steam as it exits the high-pressure separator. Blowdown temperatures are consistently less than 14 F (6 C) when constantly fed with ambient temperature feedwater. Steam Separator. As the mixture of water and vapor leaves the evaporator at high velocity and enters the steam separator through a tangential port, a natural vortex is formed. The centrifugal force of the vortex separates water droplets and contaminants out of the spiraling vapor. Pure vapor rises up through the steam separator and out of the pure steam outlet at the top of the generator. Because the separator has no baffles or demister, there are no auxiliary surfaces for condensation to accumulate and stagnate. Consequently, concerns over potential bacterial growth are eliminated. Controls. The standard control system is an Allen Bradley PLC with an Allen Bradley operator interface mounted in a NEMA rated panel. Ethernet is provided on the standard control system to facilitate communications with adjacent equipment or data archiving systems. Mueller can also provide other Allen Bradley control components, as well as control systems from Siemens and Mitsubishi. Control and electrical panels are supplied with a UL 58a label. Options Feedwater Pump System. The feedwater pump system enhances feedwater pressure and should be installed if feedwater supply pressure does not exceed the desired pure steam operating pressure by 15 3 psig (1 2 bar). When furnished, the feedwater pump system will be installed on the pure steam generator framework. Pure Steam Condensate Sampling System. Regular product testing for regulatory compliance. The sampling system will simplify your sampling methods and enab le you to draw samples for testing. The sample valve is located near the control box for easy access. Pure Steam Analyzer. This option works mutually with the pure steam condensate sampling system to measure and record the temperature and conductivity of the condensed pure steam. If the conductivity rises above the user-selected setpoint, the analyzer will signal an alarm on the operator interface. Stainless Steel Sheathing and Frame. Sheathing made entirely of Type 34 stainless steel enhances the general appearance of your unit and adds value to any facility. The sturdy Type 34 stainless steel frame enhances the generator s overall appearance, as well as improves the resistance to corrosion. Standard equipment includes a painted carbon steel frame and embossed aluminum insulation sheathing. Feedwater Analyzer. The feedwater analyzer option continuously measures and records the conductivity of the feedwater. If the conductivity rises above the userselected setpoint, the analyzer will signal the operator interface. Degasser. To ensure compliance with regulations limiting the non-condensable gas content in pure steam the degasser may be desired. The degasser uses steam from the steam separator to heat the feedwater. As the feedwater is heated the non-condensable gases are expelled and vented from the equipment. WFI Production. A pure steam condenser may be included with the pure steam generator to produce up to 15 gallons per hour (568 LPH) of WFI. The condenser may be provided integral to the pure steam generator skid or as a separate skid. 4

Paul Mueller Company The Mueller PyroPure P7 Series Advantage Schematic of Operation Optional equipment indicated: Degasser Pure steam condensate sampling system with analyzer Feedwater analyzer Pure steam out Steam supply in Condensate out Feedwater in Degasser vent out Sample port Coolant out Coolant in Waste out 5

Specifications Model Nos. P76 P714 P7145 P731 P7315 P75 P755 P799 P7995 Capacity (lb/hr) 1 6(272 kg/hr) 1,3 (59) 1,85(839) 2,3 (1,43) 2,9(1,315) 4,(1,814) 5,7(2,586) 7,3(3,311) 1,5 (4,763) FW Inlet 2,5 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC 1.5" TC 1.5" TC Plant Steam Inlet (15psig max.) 3 1" Flange 1.5" Flange 1.5" Flange 2" Flange 2" Flange 3" Flange 3" Flange 4" Flange 4" Flange Pure Steam Outlet 1.5" TC 2" TC 2" TC 3" TC 3" TC 4" TC 4" TC 6" TC 6" TC Condensate Outlet 4.75" FNPT 1" FNPT 1" FNPT 1.25" FNPT 1.25" FNPT 1.5" NPT 1.5" NPT 2" Flange 2" Flange Drain 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC 1" TC Instrument Air.25" FNPT.25" FNPT.25" FNPT.25" FNPT.25" FNPT.25" FNPT.25" FNPT.25 FNPT.25" FNPT FW Pressure/ Quantity Req d. 5 Maximum of 15 psig/maximum of 1 ppm silica or total hardness. No chlorine, chlorides, or amines. Elec. Srv. (Std.) 6 Without Pump: 115 VAC, 1 phase, 5/6 Hz.; With Pump: 46 VAC, 3 phase, 6 Hz. ( Other voltages available upon request.) Height 7 94"(239 cm) 17"(272 cm) 17"(272 cm) 115"(292 cm) 115"(292 cm) 126"(32 cm) 126"(32 cm) 143"(363 cm) 167"(424 cm) Width 7 48"(122cm) 48"(122 cm) 48"(122 cm) 5"(127 cm) 5"(127 cm) 5"(127 cm) 5"(127 cm) 61"(155 cm 61"(155 cm) Depth 7 46.5"(118 cm) 46.5"(118 cm) 46.5"(118 cm) 54.5"(138 cm) 54.5"(138 cm) 61.5"(156 cm) 61.5"(156 cm) 63.5"(161 cm) 63"(161 cm) Operating/ 1,5 lbs 2,15 lbs 2,35 lbs 2,7 lbs 2,8 lbs 5,1 lbs 5,7 lbs 819 lbs 92 lbs Shipping Wt. (68 kg) (98 kg) (1,7 kg) (1,23 kg) (1,27 kg) (2,313 kg) (2,58 kg) (371 kg) (387 kg) 1 Capacity is based on a steam supply pressure of 12 psig, a pure steam header pressure of 5 psig, and a feedwater temperature of 7 F. 2 Feedwater flow rate must be 5 to 1 percent greater than the pure steam volume produced to allow for blowdown (e.g., 1 lb/hr [12 gph] pure steam requires 11 lb/hr [13.8 gph] feedwater). 3 If feedwater temperature is at least 16 F (71 C) then plant steam must be 2 percent greater than pure steam capacity (e.g., 1 lb/hr pure steam requires 12 lb/hr plant steam). If feedwater temperature is approximately 7 F, then plant steam must be 3 percent greater than pure steam capacity. 4 Generator performance curves assume no back pressure on the condensate outlet. Any back pressure must be subtracted from the inlet supply steam pressure to figure the net effective inlet steam pressure and actual unit performance. 5 If a feedwater pump is used, feedwater must be supplied at a minimum pressure of 1 psig and connection size may be larger than indicated. 6 Other electrical services must be specified at time of order. 7 Dimensions and weights do not include options. All specifications subject to change without notice. 6

Paul Mueller Company Pressure and Temperature Charts PyroPure Pure Steam Generator Capacity Curves 1. Select the chart(s) with pure steam capacities closest to the one you need. 2. Locate your supply steam pressure on the vertical axis. 3. Follow that line across to the point where it intersects with the curve representing your required pure steam pressure. 4. Drop down from this point to the horizontal axis to determine the model s pure steam capacity. 5. Select the model which most closely fits your capacity needs given your pressure requirements. Note: Capacities shown are approximate and do not include an allowance for pure steam sampling. 14 14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P76 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P714 25 5 1 15 2 3 35 4 45 5 55 6 65 7 75 (23) (45) (68) (91) (136) (159) (182) (24) (227) (25) (272) (295) (318) (341) (114) 2 4 6 8 1 12 14 16 (91) (181) (272) (363) (454) (545) (636) (726) 14 14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P7145 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P731 2 4 6 8 1 12 14 16 (91) (182) (272) (363) (454) (545) (636) (726) 4 8 12 16 2 24 28 32 36 (182) (363) (545) (726) (98) (19) (1271) (1453) (1634) 7

14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 1 psig (.7 bar) 24 F (116 C) 2 psig (1.4 bar) Model P7315 14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P75 4 8 12 16 2 24 28 32 36 (182) (363) (545) (726) (98) (19) (1271) (1453) (1634) 5 1 15 25 2 35 45 3 4 55 5 6 (2268) (2722) (227) (454) (68) (1134) (97) (1588) (241) (1361) (1814) (2495) 14 14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 1 psig (.7 bar) 24 F (116 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) Model P755 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 3 psig (2.1 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) 4 psig (2.8 bar) Model P799 5 1 15 25 2 35 45 3 4 55 5 6 (2268) (2722) (227) (454) (68) (1134) (9 7) (1588) (241) (1361) (1814) (2495) 7 9 6 8 1, 1 2 3 4 5 11, (3175) (482) (2722) (3629) (4536) (454) (97) (1361) (1814) (2268) (499) 14 13 (9.) 12 11 1 9 8 7 6 5 4 3 2 1 (.7) 1 psig (6.9 bar) 338 F (17 C) 9 psig (6.2 bar) 8 psig (5.5 bar) 7 psig (4.8 bar) 6 psig (4.1 bar) 37 F (153 C) 5 psig (3.5 bar) 4 psig (2.8 bar) 3 psig (2.1 bar) 2 psig (1.4 bar) 1 psig (.7 bar) 24 F (116 C) Model P7995 7 9 6 8 1, 1 2 3 4 5 11, (3175) (482) (2722) (3629) (4536) (454) (97) (1361) (1814) (2268) (499) 8