Legionella and cooling towers

Similar documents
CONTROL OF LEGIONELLA AUDIT PROFORMA

FINAL EVENT LIFE+ BIOMOMI BIO-MONITORING AND AUTOMATIC MICROBIOLOGICAL CONTAMINATION CONTROL SYSTEM OF INDUSTRIAL HYDRAULIC CIRCUITS

Control of legionella bacteria in water systems

A guide for employers

A Guide to Trouble-Free Cooling Towers

Controlling Legionella in Plumbing Systems. Presented by: Julius Ballanco, P.E. President, JB Engineering and Code Consulting, P.C.

A guide to developing risk management plans for cooling tower systems

Legionella: The Invisible Killer

Legionnaires disease. A brief guide for dutyholders. Who is this leaflet for? What is legionnaires disease? Where are legionella bacteria found?

U.S. Department of Labor

EUROVENT 9/7 RECOMMENDED CODE OF PRACTICE TO KEEP YOUR COOLING SYSTEM EFFICIENT AND SAFE

THE USE OF OZONE IN COOLING TOWERS

Ozone in Cooling Towers : Hygiene for us

Thermo Siphon Solar Systems

Outbreak of Legionnaires disease in a hotel in Calpe, Spain December 2011 January February 2012

Guidelines for Control of Legionella in Ornamental Water Features

Guidance Note on Flushing

An Overview of Legionella Analyses By Diane Miskowski, MPH EMSL Analytical, Inc. October 2014

CODE OF PRACTICE FOR THE CONTROL OF LEGIONELLA BACTERIA IN COOLING TOWERS

Legionella Risk Management

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems

Innovation and Progress in Water Treatment Technology

Guide to Legionella control in cooling water systems, including cooling towers

T.P. Technology plc. (Tarn-Pure TM )

Indoor Air Quality Issues for Hotels

European Guidelines for Control and Prevention of Travel Associated Legionnaires Disease

Preventing Legionellosis

AIR CONDITIONING MAINTENANCE

Outbreak of Legionnaires disease in Lazise, Italy, July August 2011

Operations & Maintenance. Manual. For Series TCI Cooling Towers

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems

Ultra Violet Disinfection

Maintenance for Energy Efficiency

Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

Legionella Managing Risk. Judith Richardson Director Qube Environmental Asbestos & Legionella Management

2014 Service Technician Training Program Closed Loop Systems

Troubleshooting tips Key. What colour is the water? Reddish-orange. Yellowish-brown or tea-coloured

GUIDE TO LCA STANDARDS FOR SERVICE DELIVERY

SILVER BULLET SUMMARY

Legionnaires disease. Part 2: The control of legionella bacteria in hot and cold water systems

HVAC Checklist - Long Form

Domestic Chemical Water Treatment Manufacturers Association

Best practice guidelines Cooling towers

Water systems Health Technical Memorandum 04-01: The control of Legionella, hygiene, safe hot water, cold water and drinking water systems

Cooling Towers: Understanding Key Components of Cooling Towers and How to Improve Water Efficiency

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos

MAINTAINING YOUR SPA WATER

Trichloramine and Asthma in Swimming pools & spas Problem solved

COOLING WATER MANAGEMENT

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

Repair and Disinfection of Water Mains Water Protection Program fact sheet

INTAC PARTS & SERVICES ( H)

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

cooling tower inspection tips

Food Protection Services

By: Jaap Hoogland SPX Cooling Technologies GmbH. CW /Jaap Hoogland/ Seawater Cooling Tower Circuits 1

PHYSICAL, CHEMICAL AND BIOLOGICAL ASPECTS OF WATER -An Overview of Fouling - T. Reg. Bott

Alfa Laval Abatigo. Redefining adiabatic cooling

Anti-Microbial Pest Control

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

Optimization of Cleaning-In- Place (CIP) processes in bottled water industry

SAMPLING AND CONTROLLING LEGIONELLA BACTERIA IN DOMESTIC WATER SYSTEMS

Stenner Pump Chlorinator Installation & Start Up Guide

Environmentally Friendly Solutions for Industry MEXEL 432 CASE STUDY - GEOTHERMAL POWER GENERATION

SECTION IV-2 THE BASICS OF CLEANING MILKING EQUIPMENT

Guidance for the control of Legionella

WASTEWATER TREATMENT OBJECTIVES

Chapter 7 Hydraulic System Troubleshooting

Housing Solutions Group. Water Hygiene & Legionella Safety Policy and Management System HOUSING SOLUTIONS GROUP TITLE: PAGE: 1 OF 27 VERSION: 2.

Storage-stable Aqueous Solutions of Chlorine Dioxide

AIR CONDITIONING TECHNOLOGY

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

CHILDCARE SETTINGS. Childcare Settings

CARE HOMES AND NURSING HOMES

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

Chemical incompatibility may cause dramatic filter plugging. This may happen when fuels with incompatible additive packages are mixed.

Elements of an integrated anti-fouling strategy with emphasis on MONITORING

Ion Exchange Softening

Fuel Polishing Frequently Ask Questions.

Chapter 14 Quiz. Multiple Choice Identify the choice that best completes the statement or answers the question.

ACO Cleaning principles for drainage

Increasing Cooling Tower Water Efficiency Chang Sub Kim Mentor: Melany Hunt Co-Mentors: Jim Cowell, John Onderdonk, Matthew Berbee

AIR PUMPS & ACCESSORIES

Filtration Guide. Introduction. Benefits of Clean Water

The uses of chlorine dioxide exploit the advantages over chlorine. The main applications are detailed below, along with any additional information.

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TECHNICAL DOCUMENT. European Legionnaires Disease Surveillance Network (ELDSNet) Operating procedures.

Restoring bore pump performance

Introducing an All New Line of Cleaning Chemicals

DRAFT July, 2006 Page 1 of 18

Legionella (associated) risk management. Andrew Vickers Health Protection Programs Public Health Services SA Health

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

HVAC Design Requirements

Action Plan Template HVAC Page 1

Iron and Manganese BACTERIA AND IRON AND MANGANESE

PRINCIPLES OF FLUE GAS WATER RECOVERY SYSTEM

MILKING SYSTEM CLEANING AND SANITIZING: TROUBLESHOOTING MILK BACTERIA COUNTS. Alan Monken and Winston Ingalls West Agro, Inc. Kansas City, Missouri

Transcription:

Legionella and cooling towers The following recommendations should not be interpreted to guarantee the absence of Legionella bacteria or any other particular pathogen.

What s Legionella? Aerobic Bacteria (39 species identified) among which legionella pneumophila: most commonly associated with disease outbreak (legionellosis)

What s Legionella? Living conditions: Natural aquatic bodies Man-made water systems Transmission to human beings Via air only; inhalation of contaminated water under the form of aerosol smaller than 5 µm; aspiration (people who smokes or who have lung problems) Risk factors: cigarette smoking, chronic lung disease, immuno-depression, organ transplantation, regular use of corticosteroid medicines, age over 55.

Factors favouring the presence of Legionella Stagnating water (tanks, reservoirs, dead legs in piping systems, poor flow areas) Temperature between 20 and 45 C (under 20 C they survive over 60 they are killed) ph 5.5 to 8.1 Presence of ferrous ions (from corrosion, from ferruginous water (biocide treatments like chlorine or ozone corrode materials) Presence of zinc, calcium, scale and magnesium Death rate: 100% Rapid death Death rate: 90% - 2 mn. Deat rate: 90% -2 hours growth Presence of viable bacteria

Factors favouring the presence of Legionella Presence of sediment, sludge, scale, organic materials Biofilm (layer of micro organisms contained in a matrix that may form a thin layer of slime on surfaces in contact with water). Optimal conditions for biofilm: Roughness of the support Corrosion of the material Wall scaling

Factors favouring the presence of Legionella Presence of microorganisms (algae, amoebae, other bacteria) that can host legionella. Rubber, silicone and some plastics Absence of biocides (attention to low performance of chlorine against biofilm)

Permanent water streaming Temperature under 20 and over 50 C Silver and copper ions Brominate Factors preventing the presence of Legionella

Sources for Legionnaire Disease Major source: water distribution systems of large buildings (incl. hospitals and hotels) Mist machine, humidifiers, whirlpool spas, showers Cooling towers: long been considered as an important source but new data have contradicted this prejudice

Flows in a cooling tower

Cooling tower Motor Group Fan stack Drift Eliminators Fill film packing Water Distribution Fill grids Louvres

Prevention in CT Prevention must be considered at two levels : Minimizing the legionella amplification Preventing the bacteria diffusion

General : Minimizing amplification in cooling towers Water quality evaluation Minimizing water stagnation Minimizing process leaks into the cooling system that provide nutrients to bacteria Maintaining overall system cleanliness Applying scale and corrosion inhibitors as appropriate Controlling the overall microbiological population

Minimizing amplification in cooling towers New cooling tower : Following items must be taken into account when building a new tower: Minimizing corrosion in the installation (material choice) Choice of appropriate fill (depending on water quality) Minimizing scaling and fouling Avoiding water stagnation Access to the basin, water distribution and drift eliminators have to be foreseen

Minimizing amplification in cooling towers Appropriate maintenance of towers : Maintaining a clean water circuit does not only prove its medical interest but also assures an optimal performance of the tower Mud That can have formed a deposit in the basin must be removed Make-up system Sump Piping Pumps must be maintained and cleanliness of the hydrant must be controlled Control the good water drainage and clean the debris Check the cleanliness and if necessary clean Water treatment System must be regularly checked and maintained

Minimizing amplification in cooling towers Before Cleaning After cleaning

Preventing bacteria diffusion General : Use of high-efficiency drift eliminators at air inlet (to prevent blow-off) At air outlet (plume) Natural draft tower Height of the tower High dilution of the plume

New cooling tower : Preventing bacteria diffusion Use of high-efficiency drift eliminators at air inlet (to prevent blow-off) At air outlet (plume) Presence of inhabitated buildings in the neighbourhood and orientation of winds should be taken into account

Sources of problems Breach of drift eliminators Scaling or partly filling of the spaces between the drift eliminator waves An increased or decreased water flow, which is no more conform to the capacity of the tower A deterioration of the water distribution and sprayers An increased or decreased fan power (change of the wind velocity through the drift eliminator can cause

CT Maitenance A CT tower in bad condition can contaminate 50 x more than one which is perfectly designed and maintained. Water distribution and sprayers must be in good state and function optimally If sprayers are damaged they have to be replaced Drift eliminators Must be clean, in good state, without apparent deformation They must cover the whole air outlet surface If dirty they must be cleaned If damaged they must be replaced by the same type or an equivalent, ackwowledged by the CT supplier.

Fill Must be clean, free of scale and fouling CT Maintenance If possible, it must be cleaned by vibrations, ultrasonic system or high pressure water system. If not possible, it must be replaced

Replacement of worn or broken parts CT Maintenance The spare parts of a CT must be replaced by identical parts by specialists who know the water distribution type drift eliminator type aerodynamic characteristics of the fill (pressure loss) heterogeneities of the repartition of air velocity on the drift eliminator Any inappropriate replacement of those parts can generate drift increases