HY-DIV268N-5A two phase hybrid stepper motor drive manual

Similar documents
Avoidance of dust, oil mist and corrosive gas. Temperature. Service Environment. <80%RH, no condensation, no frosting Vibration 5.

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Datasheet of the Easy Servo Drive ES-D VDC, 8.2A Peak, Close-loop, No Tuning. Version

UIM2901-5A MACH3 breakout board

FASTERCNC CO,. LTD. FASTERCNC CO,. LTD.

mach3 cnc Stepper Motor Controller operation instruction ST6560-T3 3axis mach3 cnc

User s Manual. For DM542. Fully Digital Stepper Drive. Version All Rights Reserved

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Adjustment functions for both span and shift have been incorporated

POINTS POSITION INDICATOR PPI4

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

M860. User s Manual. High Performance Microstepping Drive. For. Version All Rights Reserved

MANUAL FOR BREAKOUT BOARD HG06

Smart DeviceNet Remote I/O Terminals

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Stepper motor I/O. Application Note DK Motion Control. A General information on stepper motors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

ABB Drives. User s Manual HTL Encoder Interface FEN-31

SYSTEM 4C. C R H Electronics Design

Micro-Step Driving for Stepper Motors: A Case Study

11. PROTECTIVE CIRCUITS, LED INDICATORS and FAULT CONDITIONS... 15

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Analog Servo Drive 25A8

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

The full wave rectifier consists of two diodes and a resister as shown in Figure

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

FRENIC5000MS5 for Machine Tool Spindle Drives

Incremental Rotary Encoder E6B2

SYSTEM 45. C R H Electronics Design

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Points Position Indicator (PPI1) for Points Motors with Common Ground

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Cross-beam scanning system to detect slim objects. 100 mm in

CQM1-SF200/CS1W-SF200

Next. Quick. Step. Setup 5HIHUHQFH 0LFURVWHSSLQJ 'ULYH. Industrial Devices Corporation. Twice the Power at Half the Size.

GLOLAB Two Wire Stepper Motor Positioner

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

650W Single Output Power Supply

How To Read A Pipe From A Sensor

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

A.3 ALARMS (SERIAL SPINDLE)

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

T0118 T2118 T3118. Instruction Manual

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

CNC-IN tel: Instruction

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

QR12 (1.22 ) Diameter Optical Encoder

User Manual for CH-PFC76810

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

revolution Contents: Introduction Power 28-pin Project Board with input/output cables

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Power Supplies 3. SDN-P DIN Rail Series

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Adding Heart to Your Technology

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Liquid Leakage Sensor Amplifier

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Absolute Rotary Encoder E6CP

A Practical Guide to Free Energy Devices

NX safety stand-alone

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Tina 2A/B Adaptor unit

Magnet field- and Radiation Tolerant New Power Supply System MARATON - Technical Overview. 22-Sep-03 1

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Unit 96: Marine Propulsion Power Plant

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

12 Volt 30 Amp Digital Solar Charge Controller

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

W150: Miniature photoelectric switch series with completely integrated electronics

Transcription:

Product Link: HY-DIV268N-5A two phase hybrid stepper motor drive manual http://www.thanksbuyer.com/cnc-single-axis-tb6600-0-2-5a-two-phase-hybrid-stepper-motor-driver-controller-24891

一, an overview HY-DIV268N-5A subdivision-type two-phase hybrid stepping motor drive using DC 12 ~ 48V power supply, suitable for drive Two-phase hybrid stepping motor dynamic voltage 12 to 48V, the current is less than 5A outer diameter of 35 to 86 mm. This drive using the drive's current loop subdivision control, the motor torque ripple is very small, low-speed running is very smooth, almost no vibration and noise. High-speed torque is much higher than other two-phase drive, high positioning accuracy. Widely used in the engraving machine, CNC machine tools, packaging machinery and other high resolution requirements on the device. The main features 1 average current control, two-phase sinusoidal current drive output 2 DC 12 ~ 48V power supply, the internal integration of 12V and 5V regulator 3 optically isolated signal input / output 4, overvoltage, undervoltage, overcurrent, and white short-circuit protection

5 4 file segmentation and automatic half-streaming capabilities up to 16 segments 4 file output phase current settings 7 high starting speed 8 high-speed torque 一, the electrical parameters Input voltage DC 12 ~ 48V input The input current of 1 to 5 amps, select the drive a stepper motor. Output current of 0.2A ~ 5A Temperature Operating Temperature -10 to 45 ; Storage temperature -40 to 70 Humidity not condensing, not drops Gas prohibit combustible gas and conductive dust Weight 200 grams 二 Control signal interface Figure 1 is a wiring schematic of the drive 1, the definition of control signals PUL +: step pulse signal is input side or the positive pulse signal input positive terminal PUL-: the negative input of the negative input pulse signal or a positive pulse signal DIR +: stepping direction signal input to the positive terminal or negative pulse signal input to the positive terminal DIR -: stepping direction signal input of the negative side or reverse step pulse signal input negative terminal EN +: offline can reset signal input side is EN-: offline can reset signal input negative terminal Offline enable signal is active, reset drive failure to prohibit any pulse, the output of the drive Power component is turned off, the motor holding torque. 2 Control signal connections PC control signal can be high, also can be low effective. When active high, the control signal The negative side together as a signal to active low, positive side of all control signals together as a signal common. For example, open-collector and PNP output interface circuit diagram is as follows:

Figure 2. Input interface circuit (common cathode connection) Note: the VCC is 5V, R short; VCC value of 12V, R 1K, more than 1/8W resistor; VCC value of 24V, R 2K, more than 1/8W resistor; R Must be connected to the controller output terminals. 三 Function selection (DIP switch on the drive panel) 1 Set the motor per revolution steps The drive to set the number of steps per motor revolution is 200 (whole step), 400 (2 segments), 1600 (8 segments), 3200 steps (16 segments). The user can drive the front panel DIP switch SW3 is SW4 bit of the drive to set the number of steps (such as Table 1): Table 1 2 Set the output phase current To drive torque stepper motor, the user can drive panel DIP switch SW1, SW2 is to set the drive output phase current (RMS) unit amperes, the switch position Corresponding to the output current, output current value corresponding different types of drive. Concrete are shown in Table 2. Output Current (A Table 2 3 Current setting 4, the semi-flow functionality The semi-flow function is a step pulse 200ms, the driver output current is automatically reduced to the rated output current 50%, used to prevent motor heating. Fourth, the power interface 1, DC +, DC-: to connect the drive power DC +: DC power level, power supply voltage DC 12 to 48V. The maximum current is 5A. The

DC-: DC power supply negative level. 2, A + A-B + B-: to connect the two-phase hybrid stepping motor Drive and two-phase hybrid stepper motor's connection with the four-wire system, the motor windings in parallel and series connection, and connection method, high-speed performance, but the drive current is large (for motor winding current of 1.73 times), Connected in series when the drive current is equal to the motor winding current. Five, the installation Around to have 20mm of space, can not be placed next to the other heating equipment, to avoid dust, oil mist, Corrosive gases, high humidity is too big and strong vibration. + Figure 3. Six fault diagnosis 1, the status light indicates RUN: green light in the normal work. ERR: red light, power, light, power indicator