ALPHANUMERIC DISPLAY BOARD HL 980 / V2

Similar documents
Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

User s Manual Before using the inverter, you need to read and save the safety instructions.

Cable Plug acc. to DIN EN , Form A

Manual. Solar Fountain Mobile Phone Charger

Cable Tester Pro ORDERCODE D1909

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

PD 100A. Printing data system

User Guide Reflow Toaster Oven Controller

Keep it Simple Timing

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

=============================== WARNING

s!nus-elektrotechnikai bt. Industrial IT & Automation

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

Application/Connection Examples

RC2200DK Demonstration Kit User Manual

UPS Network Interface. Quick InstallationGuide

1. SAFETY INFORMATION

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

LDG DTS-4/4R Desktop Coaxial Switch / Remote

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Bluetooth HC-06 with serial port module Easy guide

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Rev GSM base station. Installation instructions

DOSISYS. Hands Free Reader LDM LDM 220. User Manual A

Bluetooth UART/RS232 Module

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Harris IRT Enterprises Digital Resistance Tester Model XR

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

Fuel Alert FA-KRS-P21. Mounting instruction

User Manual Revision English

MANUAL PC1000R

AR-721U/721K/661U User s Guide

Duct Humidity Transmitter

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC WattsVIEWTM. Models: DC Serial DC-1000 USB DC-25000

Using HyperTerminal with Agilent General Purpose Instruments

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Application Note. Positioning with Dimetix distance sensor and SEW inverter FLS-C

Solar Controller / Battery Charger User s Manual

The $25 Son of a cheap timer This is not suitable for a beginner. You must have soldering skills in order to build this kit.

with Electronic Assistant

L Firmware And FPGA Configuration Upgrade

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

RS - SPM. Serial parallel translator module

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Advantium 2 Plus Alarm

s!nus-elektrotechnikai bt. Industrial IT & Automation

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

How To Use A Power Supply Unit (Upu)

INTRODUCTION FEATURES OF THE ICM

VOICE RECORDING SYSTEM ISDN PRI / BRI

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

HP UPS R1500 Generation 3

Wind Sensor W-RS485 with RS485 Interface

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

12 Volt 30 Amp Digital Solar Charge Controller

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

TP- 051 GPS RECEIVER

is then retained absolutely without interruption.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

BMW CAR-PC MONITOR MODEL SPECIFICATION BMW3/5 SERIES. Model Name : BMW-100P Paper Version : Ver 1.0

O C M III. Open Channel Flow Monitor

MTX-D, Oil Temperature/Pressure Gauge

Advanced Data Capture and Control Systems

Temperature & Humidity SMS Alert Controller

Bluetooth to Serial Adapter

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

CYMAQ Marking System AS200 + DS7050 N-14

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

Installation and Operating Instructions (for chargers shown below)

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

DK40 Datasheet & Hardware manual Version 2

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

Charge Regulator SCR 12 Marine

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

MiniTimer HL 440 User Manual. Version 06/2014

PixelController II Art-Net controller for LED pixels

1 Serial RS232 to Ethernet Adapter Installation Guide

EDI Distributor Control Interface Wiring and Setup Instructions

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

GV- RK1352 Card Reader

version 3.1. Security modem with USB port user guide

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Transcription:

ALPHANUMERIC DISPLAY BOARD HL 980 / V2 USER S MANUAL 1. Concept Page 2 2. DISPLAY BOARD DESCRIPTION Page 2 3. DISPLAY BOARD IDENTIFICATION Page 3 4. USAGE RECOMMENDATIONS Page 4 5. CARACTERISTIQUES TECHNIQUES Page 4 6. DATA LINK Page 4 7. CONNECTIONS Page 5 8. MOUNTING Page 5 9. WARRANTY Page 5 070206 Page 1 / 5

1. Concept A display board specifically designed to meet the needs of Sports Timing. This is the phrase that sparked the development of the TAG Heuer HL 980. The HL 980 now allows you the ability to display text messages (competitor names, country) as well as numeric data (points, running time ) all with a reaction time of less than 1/10 th second. Using the most recently developed LED (Light Emitting Diode) technology for maximum visibility, the RS232 interface allows for a non-multiplexed array meaning that every character is driven by its own microprocessor. Here is an example of an assembled array for Equestrian Jumping. Nine HL 980 display cases are used to form 3 lines of 24 characters: 2. DISPLAY BOARD DESCRIPTION Mounting Insert Points Front View Identification Label Rear View Multi-line Joining Points Multi-line Joining Points Data and Power Connectors DATAS OUTPUT DATAS INPUT POWER SUPPLY 070206 Page 2 / 5

3. DISPLAY BOARD IDENTIFICATION TAG HEUER s sport event management software (available separately) sends various timing data and event information to the display board from the RS232 serial port of your computer (PC). Each piece of information destined for a particular display is addressed with a tag number at the start of each data frame, known as the display number. It is therefore crucial that the correct parameter to address and route data to connected display(s) be correctly set in the display itself. The shipped factory default setting for the display number is 1. If this must be changed you can download display management software at: www.tagheuer-timing.com Display management software (CA8_15_util) for the HL 980 allows you access to the following procedure: 1 - Attach data (RS232) and power (12vdc) to the display board 2 - Close all other Windows applications and launch CA8_15_util 3 - Select the COM port to which the display is connected to your PC 4 - Click on «Program a line» 5 - You are asked if the Display is On (power) and connected to the data port (COM), if so, click on Yes 6 - Enter the new Display ( line ) number value that you wish to use with the display and then click on OK NOTE: When the display is correctly programmed and the display number has been changed to a new value, a message of: Line x (x=new number of the display) will be shown on your PC screen. If this does not happen, power off the display, check you data connections and retry to process again. 070206 Page 3 / 5

4. USAGE RECOMMENDATIONS Installation: HL 980 displays use LED technology and thus are considered as lights. The best visibility is achieved by placing the display in a shadowed position or out of direct sunlight. The display should also be protected from overheating in the same manner and by making sure the ventilation ducts are not blocked. The display is designed to withstand some rain and water spray, but is never to be immersed. Important: A display board set in direct sunlight for a few hours can become very hot. We recommend handling precautions such as gloves at all times. 5. CARACTERISTIQUES TECHNIQUES - Power Requirements: External 12 VDC (battery) @ 6 Amperes - Voltage/Current protection: 8A internal fuse - Power consumption: Standby : 200mA (no characters displayed) 5A with all characters on at max. intensity ( T amb = 20 C ) - Temperature Range: 20 C to +60 C - Weight: 4.5 Kg - Dimensions : 1140 x 45 x 240 mm 6. DATA LINK - Data Protocol: Protocol RS232 / 9600 Baud / 8 Data bits / 1 Stop bit / No Parity - Data Frame Structure: <STX>NLXXXXXXXX<LF> <STX> : Start of text ( code <02>) N : Display number / 1 to 9 L : Intensity / 1 to 3 X : Character to display <LF> :End of Frame ( code <0A>) - Character List: ABCDEFGHIJKLMNOPQRSTUVWXYZ1234567890/ \ ( ) :. * - + abcdefghijklmnopqrstuvwxyz 070206 Page 4 / 5

7. CONNECTIONS - Connections to data and power should be done in a non-powered state - Power polarity must be strictly respected: Red +12VDC Black GND (O Volts) POWER CABLE FOR HL 980 Display HL 980 1 2 Banana Plugs GND (0V) +12VDC Recommendation: Use min 16 gauge able for power connections 8. MOUNTING The display is delivered with 2 mounting type M8 rings. There are 4 insert locations located on the top and bottom for these rings. If displays are to be joined together, 4 insert points are situated at each end of the display 9. WARRANTY 1 year from date of purchase. Transport charges are charged to the customer. Warranty is valid for Normal use. Damage caused by physical shock, over voltage, inverted polarity of power connections, etc. are excluded. TAG-Heuer Professional Timing Switzerland www.tagheuer-timing.com 070206 Page 5 / 5