Germicidal Lamp Definition. A germicidal lamp is a special type of lamp which produces ultraviolet light (UVC).

Similar documents
The photoionization detector (PID) utilizes ultraviolet

3 - Atomic Absorption Spectroscopy

T5 LongLast. GE Lighting DATA SHEET

(Refer Slide Time: 00:01:43 min)

UV-Lamps for Disinfection and Advanced

Introduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?

T5 Watt-Miser Linear Fluorescent lamps

Most of this article will be about the lowpressure mercury vapor UV lamps and how

Sap Steady UV Unit for Maple Sap

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Power consumption (kw)

Experiment #5: Qualitative Absorption Spectroscopy

The Great Internet Light Bulb Book, Part I

Vacuum Evaporation Recap

Halogen Lamps. Lamp Construction

UVC LEDs for. Environmental Monitoring

Coating Technology: Evaporation Vs Sputtering

E/M Experiment: Electrons in a Magnetic Field.

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

PPL Electric Utilities Energy Efficiency and Conservation Program

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

ConstantColor CMH MR16

A. Kinetic Molecular Theory (KMT) = the idea that particles of matter are always in motion and that this motion has consequences.

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

UV, An Effective Approved Method of Disinfection

CERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS

X-ray Imaging Systems

A Look at Accelerated Photostability Testing for Packaged Food and Drinks

Multi-Vapor Metal Halide Lamps

Energy Pathways in Earth s Atmosphere

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

X-ray Imaging Systems

POROUS BURNER - A New Approach to Infrared

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

Kolorlux. GE Lighting DATA SHEET

FILM CAPACITORS FOR ELECTRONIC LIGHTING

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

Basics of UV Disinfection

AQUADA UV Eliminate Bacteria in Your Drinking Water!

13C NMR Spectroscopy

STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

Copyright by Mark Brandt, Ph.D. 12

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Types of Light Emission

Module 2.2. Heat transfer mechanisms

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

Lasers Design and Laser Systems

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

This Little Light of Mine: Understanding Light Bulbs By Tracy Empson

Application Note AN1

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Energy. Mechanical Energy

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

What is Solar Control?

TRANSPORT OF DANGEROUS GOODS

GE ConstantColor CMH Precise MR16 20 & 35W

ENERGY EFFICIENT LIGHTING

Principle of Thermal Imaging

Electricity. Investigating spontaneous gas discharge in air as a function of pressure. LD Physics Leaflets P Sel

Dimming LFL Systems By: Shelli Sedlak, LC, Senior Specification Engineer Mike Smith, GE Lighting and Electrical Institute Specialist

BB-18 Black Body High Vacuum System Technical Description

Chapter 5 - Aircraft Welding

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Spectra of Lights: An Interactive Demonstration with Diffraction Gratings

How to keep your digital projector performing optimally over its lifetime

Tech Bulletin. Understanding Solar Performance

Interested in conducting your own webinar?

COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION

Make your home a healthier home

TO _ nothing special M A UVA ISO90 TO Lens concentr. Lens D B UVB 24.

CONSERVATION AND LIGHTING

The Three Heat Transfer Modes in Reflow Soldering

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Rusty Walker, Corporate Trainer Hill PHOENIX

Today, healthcare facilities must be prepared to face

Absorption by atmospheric gases in the IR, visible and UV spectral regions.

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

MADP T. Non Magnetic MELF PIN Diode

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Forms of Energy. Freshman Seminar

Rated Lumen [lm] Nominal. Volts [V] [lm]

Preview of Period 3: Electromagnetic Waves Radiant Energy II

Applications. Architectural

Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING

LicensedArchitect. $6.00 Volume 15, No. 3 Fall Association of Licensed Architects

Energy efficient lighting for your home find out more.

`ÉàÉÜvçvÄxÅxàtÄAvÉÅ \ÇvA 5490 S.W. 42nd St. Davie, FL Toll free Local

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Aesthetic Plus LASER TRAINING MANUAL FOR MEDICAL PROFESSIONALS. presents

ENERGY & ENVIRONMENT

Treasure Hunt. Lecture 2 How does Light Interact with the Environment? EMR Principles and Properties. EMR and Remote Sensing

Noble Gases. Outline Nobel Gas Elements Radon and Health Chemistry Homework

Guide to Starters Guide to Starters Page 1 of 17

Photons. ConcepTest ) red light 2) yellow light 3) green light 4) blue light 5) all have the same energy. Which has more energy, a photon of:

ARTIFICIAL LIGHTING lecture notes

Transcription:

1

Germicidal Lamp Basics

Outline 1. Background Germicidal Lamp Definition What does a Germicidal Lamp do? Germicidal Lamp Types Lamp Nomenclature Lamp Diameter 2. Germicidal Lamp Components Glass Filament Mount S/A Fill Gas Mercury Final Assembly 3. Germicidal Lamp Performance UVC Output vs. Temperature Optimum Hg Vapor Pressure The Cold Spot Hg Vapor Pressure Control 90-90 Region 4. Lamp Summary 5. Lamp Ballast Options

Germicidal Lamp Definition A germicidal lamp is a special type of lamp which produces ultraviolet light (UVC).

Germicidal Lamp Definition A UV (ultra-violet) lamp that emits a significant portion of its radiative power in the UV-C Band (100 to 280nm) A UV lamp that generates energy at 185nm which is particularly effective in producing ozone. An ozone producing UV lamp that produces UV energy of wavelengths shorter than 220nm that decomposes oxygen, O², producing ozone, O³. A low-pressure mercury lamp in which the envelope has high transmittance for 254nm radiation

What does a Germicidal Lamp Do? Generates energy in the UV spectrum to destroy bacteria, fungi and viruses (microorganisms). Microorganisms include several distinct groups of disease causing germs (Viruses, Bacteria, Fungi, Algae and Protozoa. ) The target of UV disinfection is the genetic material, nucleic acid. As the UV penetrates through the cell and is absorbed by the nucleic acids, a rearrangement of the genetic information occurs, interfering with the cell's ability to reproduce. A cell that can not reproduce is considered dead; since it is unable to multiply to infectious numbers within a host. The maximum absorption of UV light by the nucleic acid, DNA, occurs at a wavelength of 260nm. The germicidal lamp emitting UV at 254nm is operating very close to the optimized wavelength for maximum absorption by nucleic acids.

Two Main Types of Germicidal Lamps Low-Pressure Mercury Discharge The most common form of germicidal lamp looks similar to an ordinary fluorescent lamp but the tube contains no fluorescent phosphor. In addition, rather than being made of ordinary borosilicate glass, the tube is made of fused quartz or soda-lime glass which allow the 185nm and/or 253.7 nm ultraviolet light produced by the mercury arc to pass out of the lamp unmodified. Germicidal lamps still produce a small amount of visible light due to other mercury radiation bands. Medium Pressure Mercury Discharge Medium-pressure lamps are more similar to HID lamps than fluorescent lamps. These lamps radiate a broad-band UV-C radiation, rather than a single line. They are widely used in industrial water treatment, because they are very intense radiation sources. Medium-pressure lamps produces very bright bluish white light.

Standard Germicidal Lamp Types Standard Quartz Germicidal Lamps Oldest and most established designs 425mA operation Standard lengths and power Best electrical efficiency (Up to 40% of electrical power is converted to UV) Warm-up time approx. 30-60 sec. UVC output related to ambient temperature Ambient temperature is limited max. 40 C Over 40 C lamps will overheat UVC will decline

High Output Germicidal Lamp Types High-Output Quartz Germicidal Lamps Operate between 600 ma and 800 ma T5 or T6 configuration (15mm or 19mm OD) Approximately 2 times the UV output of standard germicidal lamps Same lengths as standard germicidal lamps available Same relationship and limitations in regard to ambient temperature as standard germicidal lamps

Amalgam Lamp Types Low Pressure Amalgam Lamps Offer 3 to 4 times higher power density Designed for stable operation over wide ambient temperature range; influence of ambient temperature is lower in contrast to standard and HO lamps Preferred lamp choice for long-term applications with low or no cycles Usable in universal orientation applications

Amalgam Lamp Types Spot & Pellet Amalgam Lamps Spot amalgam lamps have mercury amalgam applied on the inner surface of lamp. Pellet amalgam lamps have the mercury amalgam outside of the lamp arc. Lamp designs contain more robust filaments to withstand higher current operation Warm-up time: 3-5 minutes Use of amalgam allows higher lamp current and power 1-5+ A Vapor pressure controlled by amalgam composition and location Amalgam spot

Typical Germicidal Lamp Nomenclature Designation Lamp Type Length Shape Diameter Glass Type Base Type G AAAAA BBBB C DD EEE FFFF Denotes "Germicidal" Lamp Up to Five Characters Denotes "Lamp Type" Up to Four Characters Denotes "Lamp Length" T = Tubular Two Characters Denote Diameter Up to Three Characters Denotes Glass Type Up to Four Characters Denotes Base Type PH = Preheat Two digits = Length in inches Expressed in eighths of an inch L = Low ozone producing 2P = 2-pin HO = High Output Four digits = Length in mm VH = Very-high ozone producing 4P = 4-pin CL = Cell Lamp LV(H) = Spliced Lamp SL = Slimline or Single Pin U = U Lamp MNBP = MINI Bi-Pin SL = Slimline (Single Pin) MDBP - MEDIUM Bi-Pin PHA = Preheat Amalgam PHHA = Preheat Amalgam Horizontal High Output PHVA = Preheat Amalgam Vertical PHHVA = Preheat Amalgam Vertical High Output

Typical Germicidal Lamp Diameter Tube diameter designations Soft-Glass Dimensions Quartz Dimensions Inches mm mm T2 0.250 6.35 6 T4 0.500 12.70 13 T5 0.625 15.88 15 T6 0.750 19.05 19 T8 1.000 25.40 25 T9 1.125 28.58 28 T10 1.250 31.75 32 T12 1.500 38.10 38

Components of a Germicidal Lamp All germicidal lamps contain the following components Glass Quartz Glass Soft Glass Filament Mount S/A Lead Wires Filament Emission Coating Fill Gas Argon Neon Xenon Helium Mercury Liquid Hg Solid Hg Amalgam Final Assembly Ceramic Bases Plastic Base Return Wire/Lead Wires Patented Solutions

Components of a Germicidal Lamp Glass Lamps are produced using three main glass types: Fused Quartz, Synthetic Fused Quartz and Soft Glass Fused Quartz L Type Fused quartz is doped with titanium to block 185nm transmission and is used for low ozone producing applications. VH Type Fused (natural) quartz is not doped and therefore transmits in both the 185nm and 254nm region and is used for very high ozone producing applications. Synthetic Fused Quartz Synthetic fused quartz is used for very high ozone producing applications due to superior transmittance at 185nm but at significantly higher cost. Soft Glass Soda-lime glass Transmits in 254nm region only Lower Cost

Components of a Germicidal Lamp Comparison of Quartz vs. Soft Glass Glass Quartz Transmission of UVC is approximately 9% higher than soft glass, thus leading to higher initial UVC output than comparable soft glass lamps. Quartz germicidal UVC lamps can produce both 254nm wavelength (killing wave) and 185nm wavelength (Ozone). UVC maintenance over the life of the lamp is much higher over the life of the lamps. Quartz lamps can maintain 85% of their output at 16,000hrs. Quartz glass allows high current, high-powered lamp designs. (i.e., Amalgam lamps) Soft glass will not allow the transmission of UVC wavelengths below 200nm and therefore can not be used to produce ozone at 185nm. UVC transmission maintenance over the life of the uncoated soft glass lamp is approximately 30% worse than that of quartz germicidal UVC lamps. Considerable advances in internal glass coatings have extended the life time of soft glass lamps to 9,000hrs with 80% UVC output maintenance. Soft glass germicidal UVC lamps are limited to operating currents of less than or equal to 850mA.

Components of a Germicidal Lamp Glass SPECTRAL IRRADIANCE [%] 100 90 80 70 60 50 40 30 20 10 VH (TOC) / Germicidal Lamp Relative Spectral Energy Distribution Ozone generating lamp 185nm line generates ozone. Ozone is required for some specific applications to oxidize organic compounds. 0 175 185 195 205 215 225 235 245 255 265 275 285 295 305 315 325 335 345 355 365 375 385 395 405 415 425 435 445 455 465 WAVELENGTH (nm) Ozone Free Germicidal Lamp Relative Spectral Energy Distribution 100 Ozone free lamp For simple disinfection applications only 254nm line is required. 254nm line can also used for ozone destruction. SPECTRAL IRRADIANCE [%] 90 80 70 60 50 40 30 20 10 0 175 185 195 205 215 225 235 245 255 265 275 285 295 305 315 325 335 345 355 365 375 385 395 405 415 425 435 445 455 465 WAVELENGTH (nm)

Components of a Germicidal Lamp Filament Mount Sub-Assembly Lead Wires: Provide electrical connection from ballast leads to lamp filament Lamp Filament (Coil) Standard = Nominal 425mA High Output = Nominal 600-800mA Amalgam Lamp = Nominal 1.0 5.0 A Special Construction Emission Coating

Components of a Germicidal Lamp Fill Gas All are essentially high vacuum lamps, filled to a very low pressure with one or more inert gases. The gas performs several key functions in lamp operation: Reduces the required starting voltage for the discharge, such that it can be easily struck on simple ballasts. Different gases have different effects - for instance with Argon the starting is very easy but with Krypton it is somewhat more difficult. It acts as a buffer gas to protect the electrodes, reducing the impact of ions which bombard them during the anode phase, and thereby reducing erosion of the electrode by sputtering and evaporation. This very greatly extends lamp life, the gases of higher molecular weight offering the greatest degree of protection of the electrodes. It is adjusted to provide the right balance between rate of ionization of mercury atoms (required to maintain the current flow through the lamp) and the excitation of mercury atoms so as to optimize the UV generation efficiency. Its presence randomizes the direction of motion of free elections in the discharge to control their mean free path length and velocity. Depending on the lamp design and its intended application, the gas employed may be Argon, Neon or Xenon and/or a mixture of at least two of these components.

Components of a Germicidal Lamp Mercury Mercury is useful in lighting because it contributes to the bulbs' efficient operation and life expectancy. While the bulbs are being used, the mercury within them poses no health risk. Germicidal lamps operate at a very low gas pressure. They produce light when an electric current passes between two electrodes (also called cathodes) in a tube filled with low-pressure mercury vapor and inert gases. The electric current excites the mercury vapor in the tube, generating radiant energy, primarily in the ultraviolet (UV) range. Mercury Levels (determined by dose levels) Liquid Mercury: Solid Mercury: Amalgam: Spot: Pellet: 10 to 50mg per lamp < 10 mg per lamp (Mercury containing alloy) ~ 30mg per lamp < 10mg per lamp

Components of a Germicidal Lamp Finished Assembly /4P /MNBP /MDBP /SP

Components of a Germicidal Lamp Finished Assembly Custom Bases Customer Proprietary Patent Protection Security for aftermarket

Germicidal Lamp Performance Characteristic LP (Quartz) LP (Softglass) LP Amalgam MP Emission 185+254nm 254nm 185+254nm polychromatic Gas vapor pressure 1-10 mbar 1-10 mbar 1-10 mbar 1-5 bar Hg Operating Temperatures 30-50 C 30-50 C 90-120 C 600-800 C Arc length 5-155 cm 7-148 cm 27-200 cm 5-150 cm Lifetime 16000h ¹ 13000h ¹ 16000h ¹ 3000-5000 h Germicidal efficiency (200-300 nm) 30-40% 30% 30-35% 12-16% Power density (W/cm) 0.3-0.5 0.25-0.3 1.0-2.0 50-250 Influence of ambient temp. HIGH VERY HIGH LOW NEGLIGIBLE ¹ With Longlife Coating

Relative UVC Output vs. Temperature 120% 100% Amalgam Lamp Relative Output (%) 80% 60% Standard Lamp 90-90 Line High Output Lamp 40% 20% 0% 4 8 12 16 20 24 28 32 36 40 Temp (C)

Optimum Mercury Vapor Pressure The concentration of mercury atoms in the discharge (the mercury vapor pressure) must be controlled in order to optimize the conversion of electrical power to UV radiation. The lamp will produce its maximum output when the mercury vapor pressure is approx. 6 microns (.006 Torr). At low vapor pressures the lamp output is low since there aren t many atoms available for the e - to excite! At high vapor pressures, the majority of available atoms are in the ground state (not excited) and can absorb whatever 254nm photons are produced.

The Cold Spot Only 1% of the lamp surface needs to be held at ~45º C (this is when the lamp will produce it s maximum output.) Lightly-loaded lamps: no definite cold spot (still air operation) Highly-loaded lamps: Cold spot behind cathode in region shielded from positive column. Now temperature of cold spot dependant on: The infrared radiation falling on it from (1) the inner wall of the lamp, (2) the positive column directly, and (3) the filament. One filament may also be mounted on extended leads to provide for more isolation from filament heat. Location of cold spot in highly-loaded lamp

Mercury Vapor Pressure Control One way to control mercury vapor pressure is to incorporate an amalgam into the lamp structure: Amalgams are alloys of mercury and other metals such as indium, lead or zinc and can be formulated to act as a reservoirs for mercury Amalgams release only enough mercury to hold mercury vapor pressure Ideally, the amalgam lamp design will stabilize the lamp mercury vapor pressure in the so-called 90/90 region (optimum operation) The range of bulb wall temperatures where the lamp output drops to no more than 90% of it s peak value.

Mercury Vapor Pressure Control Early amalgam germicidal lamp designs would place the amalgam spot or spots on a location at the inside wall of the lamp fully exposed to the positive column: Locations have advantage of rapid warm up and stabilization since mercury vapor can diffuse readily throughout the volume of the lamp. Major disadvantage: Portions of the lamp envelope adjacent to the positive column are exposed to widest temperature variations from varying ambient and lamp operating conditions. Temperature variations can overwhelm the best amalgam composition s ability to hold lamp output in the 90/90 region. Newer lamp designs shield amalgam from positive column by placing it outside discharge volume at one end of lamp: Temperatures can be up to 20 C lower than on the lamp wall

90-90 Range for LP vs. Amalgam Lamps

Bulb Wall vs. Pellet Amalgam Temperature

Factors Affecting Lamp Performance Lamp Design Ambient Temperature (Temp. of Gas or Liquid around lamp); Thermal Conductivity of Medium; Age of Lamp; Operating Frequency of Ballast; Frequency of On / Off cycles

Which Germicidal Lamp Do I Choose Standard Lamps: Applications where flow rates are lower, and exposure time can be longer. HO Lamps: Applications where higher flow rates or dosages are required while maintaining a limited footprint Amalgam Lamps: Applications where very high output is required and/or ambient temperature is an issue.

Lamp Ballast Options Preheat Start The cathodes of the lamp are preheated electrically for a few seconds before a high voltage is applied to start the lamp. The preheating is accomplished by applying current to the cathodes for sufficient time to heat them. The preheat lamps have two connections at each end. This lamp type results in a slight delay in lamp starting Pre-heat ballasts tend to be more expensive Required for high current lamps (>300W) Required in applications with multiple lamp starts per day

Lamp Ballast Options Instant Start The instant start lamp requires a high starting voltage, which is supplied by the ballast. Since there is no preheating of the cathodes, there is no need for a starter circuit Electrode heating is provided by the arc once it has been established. The instant start lamps have a single pin base at each end of the bulb. A few instant start lamps have bi pin bases, with the pins connected together inside the base.

Lamp Ballast Options Programmed Start Lamps The programmed start ballast incorporates a starting method which is gentler on the lamp than either the rapid or instant start ballasts. Program start ballasts incorporate a precise starting scenario which breaks the process into unique and well defined steps that eliminate the pitfalls of the other starting methods. The first step in the series is the application of cathode heat. While this heat is being applied (preheat interval), voltage across the lamp is reduced to a level that reduces damaging glow current. The duration of this step is pre-programmed into the ballast circuitry. Since the lamp voltage is kept very low, the lamps cannot ignite until the cathodes are heated to optimal temperature and the ballast program moves to the second step. The second step of the starting process is the application of lamp voltage. After the programmed time of step one has been reached, a voltage is applied across the lamps, igniting them with minimal loss of the emissive material. Minimal loss of the emissive material equates to gentle treatment of and prolonged life for the lamp.

Questions Thank you for your attention!