SRT screw removal tool

Similar documents
Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

White Industries Rear Hub Instructions

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Guidance for implant removal. Straumann Dental Implant System

S&G Model 2937 Group 1 Combination Lock

How To Use A Phoenix Retrograde Femoral Nail

CALIBRATION FOR LAL20X & LAL24X

Cable Drum Installation

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

1.8 CRANKSHAFT OIL SEALS

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

Zimmer Small Fragment Universal Locking System. Surgical Technique

Product Catalog. ERA Mini TM Dental Implant System

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

3/4 PIPE CLAMP WITH STAND

NARROW DIAMETER implant

TRI-CAM Implant System

DUBOX TM LOOSE PIECE HAND TOOL

Assembly and Usage Instructions

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

SAFETY & OPERATING INSTRUCTIONS

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

HT-0095 Mini PV Receptacles AWG Crimping Hand Tool. Tool P/N HT-0095

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Dental Implant Options in Atrophic Jaws

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Zimmer Periarticular Proximal Tibial Locking Plate

Zimmer Periarticular Elbow Locking Plate System

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Front brakes (FN- 3), servicing

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Regular C/X Prosthetics. Prosthetics

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installation Instructions S

Written By: Sam Lionheart

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

Dissolved Oxygen Sensors

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Technical Information

Restorative Manual Impression Transfer System

Lentur Cable System. Surgical Technique

INTRODUCTION INTERLOCK KIT K-8110

HUMULIN 70/30 KwikPen

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

BOWIE PUMPS OPERATION - MAINTENANCE

Strut Spring Compressor

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Metasul LDH Large Diameter Head

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Step-by-step instructions:

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

MyoSure Hysteroscopic Tissue Removal System MyoSure XL Tissue Removal Device Instructions for Use

UV100A Ultraviolet Air Treatment System

HEAD BOLT THREAD REPAIR SYSTEM M11X1.5 head bolt thread repair for Cadillac Northstar 4.6L V8 & Oldsmobile Aurora 4.

Gl GinGival level implant

Assembly and instructions

Stainless Steel Single and Dual Circulation Kits

procedures & products NOBELESTHETICS including Procera

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS


TwinFix Cannulated Compression Screw

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

V-TEK IVP System 2.7 System 4.0

NCB Distal Femur System. Surgical Technique

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Speed-Mat Rectangle Cutter

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Replacing the Gateway M320 Keyboard

AMPSEAL* Automotive Plug Connector and Header Assembly

Posterior Referencing. Surgical Technique

KAWAI VERTICAL PIANO REGULATION MANUAL

Determine the desired location fixture and center the coaxial cord location to the electrical box.

Mani Silk: A new and novel means of predictable canal shaping

LOCATOR BAR ATTACHMENT SYSTEM

HAIR CLIPPER. Model No. HC5150 HC

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Achilles Tendon Repair, Operative Technique

Instructions and care

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

MINI ELECTRIC SEWING MACHINE OPERATION MANUAL

Mini multi-purpose sewing machine

PRODUCT: 3/8 RIVET NUT INSTALL INSTRUCTIONS READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 8:00 AM 5:00 PM PST

Transcription:

SRT screw removal tool As far as the SRT tool, the clinician will place the tip of it in the screw so it lines up into the screw hole opening. They will turn the tool slowly about ¼ of a turn clockwise, then immediately screw counterclockwise. As the doctor turns in a COUNTER-CLOCKWISE direction, the tip of the tool will burrow into the screw opening while at the same time unscrew it out of the implant. SRT screw removal tool Once the screw is out, to remove the tool from the removed screw, they will have to turn the tool CLOCKWISE. Remember the SRT is for a stripped internal hex of the screw that the.050 hex tool will not engage

Thread Tap (Ref. #0493 & 0494) Use the thread tap to repair damaged internal threads. Thread Tap 0493 is used to retap internal threads on the following implants: Integral 3.25mm, Omniloc 3.25mm, Omniloc 4.0mm Thread Tap 0494 is used to retap internal threads on the following implants: Integral 4.0mm. NOTE: Extreme caution should be exercised while using the tap. Since the tap is very small in diameter and the metal is brittle, too much force can cause the tap to break off in the implant. Tapping will generate titanium particles; water irrigation and suction is advisable THREAD TAP Detailed Instruction : 1. Expose the implant thread 2. Carefully start screwing in the tap it must start without force to ensure that it has not started to cross-thread. Continue to gently turn (clockwise) until resistance is felt. Turn gently, approximately 1/8 turn, then completely, remove tap and flush-out-hole. 3. Screw in the abutment and see if it will now seat properly. If not, remove and go to step 4. 4. 4. Using water irrigation and suction, begin tapping the hole again as outlined above. When resistance is felt, turn in 1/8 turn and back off one turn. Screw in 1/8 turn past the point of resistance and out one turn repeatedly 5. Remove tap, flush and check depth with abutment. If not seated, go on step 6. 6. Continue steps 4 and 5 until sufficient thread is achieved. DO NOT FORCE 7. after ensuring the abutment seats properly, remove it and completely flush out the hole and continue with the standard procedure

Retriever Drill P/N 2224 and Guide Sleeves P/Ns 2220, 2221, 2222, 2223 Guide sleeve and retriever drill to remove fractured abutment screw remnants from the implant body. When used properly, the system will remove a fractured screw without damaging internal screw threads and interface of an integrated implant. Retriever Drill and Guide Sleeves 2220 Retriever Drill and Sleeve P/N 2220: For use with Spline Twist and 3.25mm Spline RELIANCE Implants 2221 Retriever Drill and Sleeve P/N 2221: For use with 3.75mm and 5.0mm Spline Twist, 4.0 and 5.0mm Spline RELIANCE, and Taper Lock Implants 2222 Retriever Drill and Sleeve P/N 2222: For use with Advent, 6.0mm Tapered Screw Vent, SwissPlus standard and wide diameter (4.8mm platform), and 6.0 Micro Vent implants 2223 Retriever Drill and Sleeve P/N 2223: For use with 3.7 and 4.7mm Tapered Screw Vent, Screw Vent, SwissPlus mini (3.8mm platform), 3.25 Integral, Omniloc and 3.7 and 4.7mm Micro Vent Implants Sterility: The retriever drill and guide sleeve are sold non-sterile. Follow sterilization guidelines below prior to use in patients Sterilization/ Resterilization: Steam autoclave should be performed at 121 C/250 F, 15-20 psig for 30 min. Dry heat sterilization should be performed at 160 C/320 F for 2 hours.

Retriever Drill P/N 2224 and Guide Sleeves P/Ns 2220, 2221, 2222, 2223 Warning: Due to the very small diameter of the retriever drill, it is essential that no lateral forces be applied during its use. Procedure: A. Place the guide sleeve over the implant body, engaging the guide sleeve with the implant. The guide sleeve may be held in place with a hemostat. The guide sleeve will center the retriever drill over the fractured screw. NOTE: The guide sleeve is used to ensure that the retriever drill starts the hole in the center of the fractured screw and away from the internal thread of the implant. B. Insert the retriever drill into a reversible handpiece. Carefully place the retriever drill through the guide sleeve. NOTE: Due to the very small diameter of the retriever drill, it is essential that no lateral forces be applied during its use C. Keeping the retriever drill straight, apply moderate pressure and begin rotating in a reverse direction at a speed between 35-50 rpm. Continue drilling until the drill grabs the broken screw and backs it out. Retriever Drill and Guide Sleeves

IRT removal tool for screw-type implants As far as the IRT tool, the clinician will place the tip of it in the implant so it lines up into the screw hole opening. They will turn the tool slowly about ¼ of a turn clockwise, then immediately screw counterclockwise. As the doctor turns in a COUNTER-CLOCKWISE direction, the tip of the tool will engage into the screw opening while at the same time unscrew the implant. If more force is needed, place the Ratchet on top of the IRT IRT removal tool for screw-type implants Please remember this tool is intended for an implant that is loose in the bone, with little bone contact around it. If the implant is still firmly in bone contact, the IRT can break. Once the implant is out, to remove the tool from the removed implant they will have to turn the tool CLOCKWISE.