Ice Maker Trouble Shooting Procedures. Problem/Probable Cause/Remedy

Similar documents
Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Air Conditioning Sign-Off Sheet

ICER-ETTE. MODEL 84 and 85 AUTOMATIC ICE CUBE MAKER INSTALLATION, OPERATION, MAINTENANCE AND TROUBLESHOOTING

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Ice Maker. User Manual HI6LMK. Haier America New York, NY Haier America Trading, LLC.

Troubleshooting Your Refrigerator

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

12.0 cu.ft., 2-way, 4-door, R.V. refrigerator with ice maker.

For N61X models: 6 cu.ft., 2-way, R.V. refrigerators. For N81X models: 8 cu.ft., 2-way, R.V. refrigerators.

TROUBLESHOOTING GUIDE

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

SERVICE TIPS. Dometic. AMES/AES/ROYALE/ELlTE REFRIGERATORS. Models. Refrigerator Start-Up Information

TEMPERATURE CONTROLS/ THERMOMETER/TIMERS

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt

PWC-500/1000/1010/1500

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

MP-4000 Alarm List (Software version or later)

Table Z. Troubleshooting Chart for Air Conditioners. Cause

USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN

Trouble Shooting. Pump

Electric Water Heater

Oil and Coolant Circulating Heating System. Model - OCSM

COMMERCIAL GAS DRYER

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Heat Pump Water Heater IOM Manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

E2 Series Electric Furnaces

AFE424 SERVICE PARTS

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

LOBOY 16 AIR CONDITIONERS

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Compressor Service & Maintenance Manual

Line to Refrigerator Ice/Water Dispenser

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

COMMERCIAL GAS DRYER

ENGINE COOLING SYSTEM

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

Installation Instructions

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

COMMERCIAL GAS DRYER

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

GAS/ELECTRIC REFRIGERATOR

MAC FAUCETS. Owner s Manual. Models: FA444

High kw Electric Tankless Water Heater Troubleshooting Guide

AHE S SERVICE MANUAL

TS93 EMR T/PT/TDE. Surface applied door closer

GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

900 & 9100 Series. Service Manual & Parts List for Models Contents

Aquamax Australia Pty Ltd ABN

Install Guide CT101. Caution. Caution

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

CARING FOR YOUR FCB (FROZEN CARBONATED) BEVERAGE DISPENSER AND POST-MIX DISPENSING SYSTEM

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

INSTALLATION & SERVICE MANUAL. Display Panel

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Please keep these operating instructions in a safe place.

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

SMD Rework Station TABLE OF CONTENTS

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

3.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR350BE HMBR350SE

How To Check A Freezer

Commercial Refrigeration Temperature and Defrost Controls

Draft of Service Manual NDA/NDE 1402


SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

BOSCH D-JETRONIC Volkswagen: Type 3 & 4

Your safety and the safety of others are very important.

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Ice Maker Trouble Shooting Procedures Ice Maker Specifications Volts: 120 volts AC Amp Draw - cycle on, heater off:.03 amps Amp Draw - cycle on, heater on: 1.6 amps Amp Draw - cycle off: 0 amps Inlet water pressure: 15-125 psi. Duration of 1 cycle: 3.5 to 7 minutes Ice Yield: 3 lbs./24 hours Ice Maker Requirements: 1. Cold potable water supply at pressures between 15 psi and 125 psi. 2. 120 Volts AC supply - 108 VAC min -132 VAC max. 3. 1/4" O.D. cooper tubing (compression nut, compression sleeve, and 90 degree tubing adapter supplied with refrig erator) or an approved plastic tubing. 4. 1/4" Shut-off valve in water supply line. (Should be accessible when the lower vent door is open.) Problem/Probable Cause/Remedy Problem Probable Cause Remedy 1. Refrigerator Cooling: No ice in bin 1. A/C power disconnected. 2. Broken wire or loose connection. 3. Shut off arm in storage position. 4. Water supply shut off. 5. Inoperative water valve. 6. Excessive frost build-up causing Shut-off arm to hang up. 1. Connect A/C power. 2. Locate and repair. 3. Place in normal operation position. 4. Restore water supply. 5. Check valve and inlet filter for restrictions or solenoid coil failure. Repair or replace. 6. Defrost unit - inspect for door gasket leak. 2. Low ice yield. 1. Ventilation of refrigeration not in accordance with Norcold s Venting Requirements. See Section 2. 2. Insufficient refrigeration. 3. Not enough water supply pressure. 4. Thermostat setting too warm. 1. Install in accordance with Section 2 of this manual. 2. Check 120 VAC power 108 VAC min. - 132 max. 12 VDC Power 10.5 VDC min. - 15.4 VDC max. 3. A. Check for restrictions in water lines or water valve. B. Check for correct water pressure. min. 15 PSI; max. 125 PSI 4. Adjust Thermostat setting. 3. Excessive water dripping on ice cubes or from Ice Maker mold. 1. Excessive water pressure. 2. Water valve sticking open. 1. Correct water pressure min. 15 PSI max. 125 PSI 2. Check for contaminated inlet filter or replace water valve. 4. Ice maker mold overfilling with water. 1. Defective water valve. 1. Replace water valve. 5. Ice cubes are milky or have taste. 1. Water hardness or food stored in ice bin. 1. Advise customer to have water supply inspected and refrain from storing food in the ice bin. 1

Trouble Shooting Procedures These check-out procedures are based on: * 12 Volts DC (Control Voltage) is available to the Refrigerator. * 120 Volts AC is available to the refrigerator and to the Ice Maker. * Water pressure to the Ice Maker is at 15 psi min. - 125 psi max. * Thermostat is set at mid-range setting or higher. * Refrigerator is performing satisfactory and has been operating long enough to reach ice making temperatures. * The Ice Maker s shut-off arm in the down ON position. Location of Test Test Points 5/16" Mounting Screws Test points are located behind the white cover plate. To gain acccess to the test point, the ice maker is required to be moved from the freezer. Ice Maker Removal White Cover Plate Ice Bin Shelf 1. Remove the ice bin and shelf. 2. Remove the two 5/16" mounting screws. 3. With a Phillips screwdriver, remove the 2 screws under the Ice Maker. 4. Pull Ice Maker forward to remove. 5. Remove white cover plate. 6.Follow Check Out procedures. FIGURE 1 Note: The wire harness is equipped with a thermal fuse. The fuse protects the ice maker mold from overheating. If the fuse is open, the wire harness rerquires repplacement. Wire Harness Check - Figure 6 The wire harness has a thermal fuse. The fuse protects the ice maker mold from overheating. If the fuse is open, the wire harness requires replacement. Use a volt ohmmeter and check for 120 volts AC between test points L and N. Note: Insure your meter leads contact the surfaces of the test points. If 120 volts is present, proceed to "Water Valve" check out. If 120 volts is not present, replace the ice maker s wiring harness. FIGURE 2 2

Water Valve Check Energizing the Water Valve Caution: To prevent an electrical shock, use an insulated jumper wire. Note: If water is available to the water valve, performing the procedure below may overflow the ice maker s mold. Insert an insulated jumper wire between test points L & V to energize the water valve. If an audible click or buzzing is observed, the water valve is functional. Ohm Readings If the water valve is not functional: 1. Disconnect the refrigerator s AC power cord from the wall receptacle. 2. Use a volt ohmmeter; insert meter leads into test points V & N. 3. Reading between 295 and 360 ohms indicate water valve is functional. 4. Reading is infinity (maximum reading) there is a loose wire connection at the water valve s terminals or the water valve is defective. Repair loose connection or replace water valve. 5. Reading of "0" indicates a short in the wiring from the ice maker to the water valve or a defective water valve Repair the short or replace the water valve. FIGURE 3 F1GURE 4 Mold Heater Use a volt ohmmeter and insert meter leads into test points L&H. 1. 75 ohm reading indicates the mold heater is functional. 2. Reading either an open or a short requires replacement of the ice maker assembly. F1GURE 5 3

Motor Check-Out - Figure 10 Use a volt ohmmeter and insert meter leads into test points M & N. 120 volts should be present. If 120 volts is not present, replace the Ice Maker assembly. FIGURE 6 Testing Motor and Cycle Function Figure 11 FIGURE 7 This test procedure is to be performed while the ice maker is dry and at room temperature. The test cycle will take approximately 3-7 minutes to complete. During the cycle the shut-off arm will raise and lower slowly while the mold heater is on and the ejector mechanism simulates ejecting the ice. Approximately 3/4 through the cycle, the water valve will energize for 7 seconds, allowing water (if available to the valve) to fill the ice maker mold cavity. Note: If water is available to the water valve, performing the procedure below may overflow the ice maker s mold. To perform this test: Caution: To prevent an electrical shock, use an insulated jumper wire. 1. Insert an insulated jumper wire between and into test points T & H. Within 15-20 seconds an audible click will be observed indicating the start of the ice ejection cycle. Remove the insulated jumper wire once the cycle begins. 2.If an audible click is not heard, start with the "Wire Harness Check" procedure to locate the problem. 3. If an audible click is heard, the ice maker assembly is functional and does not require repair. 4

Pictorial Before July 1, 1995 Pictorial Beginning July 1, 1995 Ice Maker Wiring Pictorial 5