INSTANT HEATING FAUCET. InstructIon manual. Model no.: KDR-4E-3

Similar documents
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SERVICE MANUAL Order No.WH0911S001V0

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

SF15K SF05KSS, SF10KSS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Installation guide Nordic mixer taps. Before installing read this guide first

ELECTRIC INSTANTANEOUS WATER HEATER

Coolflo Safe Touch Shower Mixing Valve ST20015CP

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

MAC FAUCETS. Owner s Manual. Models: FA444

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)


Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Operation Manual Magic Bowling. Warning Please read this manual carefully before using this machine

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Triac Printed Circuit Board Replacement

EH-20 20m antenna. By VE3RGW

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Beam Laser Pointer Service Manual

Itho Products for Hot and Boiling water. product-

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

1 DESCRIPTION OF THE APPLIANCE

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS BL-8704

Economy Combo Heat Press Manual Model No.: ECH-800

SunMaxx Solar Filling Station Operating Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

INSTALLATION INSTRUCTIONS MK-8704

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Taurus Series YORK Window Air Conditioners

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Use and Care Manual. Model CPA12KH AIR CONDITIONER

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Dehumidifier D 850E. - Instruction manual version 02

ALL IN ONE. Heat Pump Water Heater

Please keep these operating instructions in a safe place.

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

SMD Rework Station TABLE OF CONTENTS

Assembly and instructions

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

PRESSURE REDUCING CONTROL VALVE

ELECTRIC CENTRAL HEATING FLOW BOILER

IH E Sigma Island 90

INSTANT HOT WATER RECIRCULATING SYSTEM

PLUMBING CARE AND REPAIR

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Operators manual Basic water heater

Portable Air Conditioner

Stenner Pump Chlorinator Installation & Start Up Guide

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Chill 4 Hole Bath Shower Mixer

Elson 10/15L Unvented Water Heater

Powers Controls TH 192 S Single Temperature Room Thermostat

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

RC HELICOPTER INSTRUCTION MANUAL

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

LUCCI AIRFUSION QUEST II CEILING FAN

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Stainless Steel Single and Dual Circulation Kits

Watts Pure Water Systems

Air Conditioner Water Heater Model ACWH18

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

INSTALLATION INSTRUCTIONS FOR VW MK5

LED Security Spotlight User Manual

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

This section gives you some helpful information and tips on running your home and the equipment in it.

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Reverse Cycle Inverter Split System Air Conditioner

Fully Automatic Washing Machine User manual

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

Alfa Romeo 147 On board instruments installation guide

Machine needle shut-off nozzle type-a

Transcription:

INSTANT HEATING FAUCET InstructIon manual Model no.: KDR-4E-3

product Introduction 3 Installation conditions 3 Installation methods of products 5 Installation method of downside-inlet machines 6 Key points in installation and adjustment 7 Operating method 8 Maintenance method 8 Attentions 9 Electrical diagram 10 Fault analysis and clearing methods 10 Packing list 11 Main accessories 11 Thank you for buying our Delimano Instant Heating Faucet. Please read the manual carefully before using and keep it for the future reference. 3

product IntroductIon this product can provide instant hot water within few seconds. faucet nozzle can be rotate left and right, which enables this machine to be used in single sink, double sinks and platform basin. type: Kdr-4e-3 application: kitchen, garage and the other appropriate environments water inlet style: side water inlet InstallatIon conditions Name KDR-2/3/4C-3/4 KDR-2/3/4E-3/4 Power (kw) 2 3 Indoor power source wire diameter (mm 2 ) 1.0 1.5 Air-break switch (A) 10 16 Ammeter (A) 10 20 Water pressure (Mpa) 0.04-0.6 0.04-0.6 4

the product is rated as a high power appliance - it should be checked whether electrical wiring satisfies the rated current of the product before installation (requirements stated in the chart above should be satisfied). grounding of this water heater should be ensured, i.e., there should be grounding wire in the socket and it should be connected to the grounding wire of power network. InstallatIon methods of products check the wire and water route. turn down the water gate before installation. take water heater from foam box and remove sealing paste (picture 1). Picture 1: schematic diagram of removing the sealing paste downside water inlet machine. side water inlet machine. 5

Check the position of rubber ring and circlip. (Picture 2) Picture 2: 1 - bent pipe 2 - bent pipe nut 3 - circlip 4 - rubber ring INSTALLATION METHOD OF DOWNSIDE-INLET MACHINES 1. Abut water outlet pipe with main engine and screw tight. (note: do not damage rubber ring during installation). 2. Embed sealing ring into base of main engine with crown upward. Then screw downsideinlet connecting piece into base of main engine and screw tight. 3. Insert the installed downside-inlet connecting piece into rubber ring of the base, and install them into the sink. Screw a fixing nut from below the sink to fasten main engine. 4. Connect water supply pipe with water inlet of downside-inlet connecting piece. 5. Open water gate, press down handle of main engine, rotate water outlet to left and right check and eliminate leakage before usage. 6. Insert plug into power source socket nearby. Picture 3: 1 - water outlet pipe 2 - main engine 3 - rubber ring of connecting piece 4 - downside-inlet connecting piece 5 - base rubber ring 6 - sink 7 - fixing nut 8 - water supply pipe 6

Rendering 1 Key points In InstallatIon and adjustment during decoration, please preserve 2.5-4 cm 2 power wire for water heater. If decoration is finished, with no sunk wire reserved in the wall, power wire qualified to required standards can be led-in from the nearest spot. If the position of water outlet reserved in the wall is not proper, please consult professional installer for scheme modification. planning the installation method and position in advance and careful reading of operating Instruction manual will contribute to a more efficient installation and maintenance. water supply should be turned on before electricity to ensure every joint from water leakage during adjustment when installation is done. when water supply is smooth, insert plug into socket, open hot water switch. output of water is normal; the red light of heat indicator is on; and the temperature climbs up. the red light is off when water switch is turn off. the adjustment of main engine is completed. preserved power wire 2,5 4 mm + 220-240V attention: sunk water route in the wall mind the size of the cabinet 7

Operating method As indicated in picture 5, nozzle and nozzle tube can offer a 360 degree rotation in horizontal plane, offering wash needs. Picture 4: As indicated in picture 6, there are 3 zones in index dial of the handle: cold water zone, stop zone, hot water zone. Customers can turn to different zones according to their needs. One can rotate handle up to increase flow rate of cold water, and rotate handle down to increase flow rate of hot water. Temperature of hot water will decrease with the increase of its flow rate. Temperature will gradually increase and reach balance point in 5 seconds after turning to the hot water zone. Picture 5: 1 - cold water zone 2 - stop zone 3 - hot water zone 4 - working status indicator Note: (There is automatic power switch inside this water heater, therefore, there is no need to connect and disconnect the power wire). Maintenance method Cleaning of water outlet: When water flow becomes disorder or smaller, the water outlet needs cleaning. Steps are as follows: unscrew the water outlet counterclockwise and out, flush the water outlet under high-pressure faucet upside down. Dig out and remove the adherent deposit from the hole in the water outlet with thin iron wire and then screw it back. 8

Picture 6: 1 - remove 3 - spool of nozzle 2 - install 4 - clean water outlet holes and jeep it unblocked Cleaning of water filter: If the water flow becomes small after being used for period of time, remove and clean filter as indicated in the picture below, and assemble back in turn. Picture 7: 1 - magnetic ring 2 - filter 3 - fixing ring Attentions Water supplly should be released connected to the power source. This water heater must be installed vertical, other angles are forbidden. Right installation method can be referred to in the installation diagram. If the volume of your power grid is small, please try not to use other high-power electric appliances (air conditioner, microwave, etc.) while using this water heater. Water outlet should not be connected to any faucet or joint except for required in this instruction manual. In long-term usage, if the flow rate becomes smaller, the water inlet filter should be cleaned. Nozzle should be cleaned regularly. If the water inside this heater may be iced, electrical supply to this water heater is forbidden. 9

If the flexible power wire is damaged, replacement can only be carried out in maintenance spot assigned by our company. this water heater must be safely grounded. this water heater cannot be installed in icy places. electrical diagram Picture 8: Water pressure switch. Red. Heat retaining (normal close). Heating tube. fault analysis and clearing methods 10 Phenomenon of breakdown the red light does not turn on and water does not become hot at the turning of hot water handle. the red light is on, but water temperature is low. water temperature is high, water flow rate is low red light of the indicator is on, but the water doesn t become hot. Reason of breakdown power source is not connected or water pressure is too low. water flow rate is too high. deposit blocks the filter and water outlet holes, or water pressure is low the breakdown of heating component Treatment method check power wire, check wire connecting, make sure the lowest water supply pressure is not less than 0.04mpa. adjust hot water handle and turn down water flow rate. check and clean deposits in water inlet filter and water outlet holes. turn up hot water flow rate. If this phenomenon continues, the reason is the low water pressure. please contact retailer or manufacturer.

packing list Name KDR-2C(E)-3/4 KDR-3/4(E)-3/4 Main engine 1 set Connecting piece (side inlet) 1 piece (downside inlet) 1 piece Fixing nut (side inlet) 1 piece (downside inlet) 1 piece Cushion of connecting piece Operating instructions manual 1 piece 1 copy main accessories accessories of type Kdr-3/4(e)-3/4 Cushion of connecting piece. Connecting piece (downside inlet). Base rubber ring. Fixing nut (downside inlet). 11

VISIT WWW.DELIMANO.AL