Standard Viscosity-Temperature Chart for Asphalts 1

Similar documents
Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Standard Test Methods for Viscosity of Adhesives 1

Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications 1

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1

Standard Practice for Evaluating Response Robot Capabilities: Logistics: Packaging for Urban Search and Rescue Task Force Equipment Caches 1

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

Asphalt Institute Technical Bulletin. Laboratory Mixing and Compaction Temperatures

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Standard Specification for Stainless Steel Bars and Shapes 1

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1

for Rubber property Durometer hardness

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

PHYSICS FUNDAMENTALS-Viscosity and flow

SIZE OF A MOLECULE FROM A VISCOSITY MEASUREMENT

PUMPS STEAM TURBINES BUILDING & FIRE WASTEWATER SERVICE PUMP CLINIC 22 VISCOSITY

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Rheological Properties of Topical Formulations

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

Determination of Viscosity Using A Brookfield Viscometer for Conditioning Polymers

3.3. Rheological Behavior of Vinyl Ester Resins

PENETRATION OF BITUMINOUS MATERIALS

Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1

Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes 1

Hello viewers welcome to lesson 4.7 which is on pavement materials part IV and in this lesson we will be covering bituminous binders.

Evaluation of Rheological Measurements for Unmodified and Modified Asphalt Cements

Temperature Scales. The metric system that we are now using includes a unit that is specific for the representation of measured temperatures.

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT


Standard Specification for Flat Glass 1

Putting the Simple Back into Viscosity. Written by John Sander Vice President of Technology Lubrication Engineers, Inc.

Manual of Petroleum Measurement Standards Chapter 11 Physical Properties Data

TEMPERATURE, CONCENTRATION, AND PUMPING EFFECTS ON PAM VISCOSITY

MINERAL OIL (MEDIUM VISCOSITY)

Standard Test Method for Vapor Pressure 1

Notes on Polymer Rheology Outline

Ch 2 Properties of Fluids - II. Ideal Fluids. Real Fluids. Viscosity (1) Viscosity (3) Viscosity (2)

Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids

INNOVATIVE PLASTICS HIGH & LOW SHEAR RATE RHEOLOGY

Temperature Dependence of the Viscosity of Hydrocarbon Fractions

VISCOSITY INDEX TABLES FOR CELSIUS TEMPERATURES

Standard Practice for Evaluating the Cache Packaging Weight and Volume of Robots for Urban Search and Rescue 1

Viscosity Cup Reference Table 1

American Society of Agricultural and Biological Engineers

LABORATORY.

Standard Specification for Tool Steel High Speed 1

Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Selecting a Centrifugal Pump to Handle a Viscous Liquid

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

Characterisation and Modelling of Asphalt Mastics and Their Effect on Workability

VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied.

AP Physics 1 and 2 Lab Investigations

The Correlation Coefficient

Operating Instructions, version Manual No. M/ F699

Long term performance of polymers

VISCOSITY CLASSIFICATIONS

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Shelf Life Prediction Of Medical Gloves

Performance Graded Asphalt Binders Bob Horan, P.E. Consulting Engineer Mechanicsville, VA

Comparison of Results of SHRP and Conventional Binder Tests on Paving Asphalts

Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES

Operating Instructions. Manual No. M02-312

Solutions of Equations in Two Variables

INVESTIGATION OF VISCOELASTICITY AND CURE SHRINKAGE IN AN EPOXY RESIN DURING PROCESSING

Using Excel (Microsoft Office 2007 Version) for Graphical Analysis of Data

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

precision glass capillary viscometers

The Viscosity of Fluids

MODELING THE EFFECT OF TEMPERATURE AND FREQUENCY ON BITUMEN-COATED HELICAL CABLE ELEMENTS

Standard Test Method for Measuring the Thermal Insulation of Clothing Using a Heated Manikin 1

Scientific Graphing in Excel 2010

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids

Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2

Operating Instructions. Manual No. M B0315

Straightening Data in a Scatterplot Selecting a Good Re-Expression Model

Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) 1

FLUID DYNAMICS. Intrinsic properties of fluids. Fluids behavior under various conditions

Simple linear regression

CBE 6333, R. Levicky 1 Review of Fluid Mechanics Terminology

MOLECULAR WEIGHT BY BOILING POINT ELEVATION

LOW TEMPERATURE TESTING OF ELASTOMERS

INTRODUCTION TO FLUID MECHANICS

Standard Specification for Tool Steels Alloy 1

The Viscosity of Fluids

NorthEast Transportation Training and Certification Program (NETTCP) Course Registration Form

RHEOLOGICAL PROPERTIES OF WASTEWATER SLUDGE

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Formula for Viscosity of Glycerol-Water Mixture. Nian-Sheng Cheng. School of Civil and Environmental Engineering, Nanyang Technological University,

Thickeners + Rheology Guide

Acceptance Criteria for Durability Tests

HEAVY OIL FLOW MEASUREMENT CHALLENGES

Transcription:

Designation: D2493/D2493M 09 Standard Viscosity-Temperature Chart for Asphalts 1 This standard is issued under the fixed designation D2493/D2493M; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon ( ) indicates an editorial change since the last revision or reapproval. 1. Scope 1.1 The viscosity-temperature chart covered by this standard is a convenient means of plotting data for estimating the viscosity of asphalts at any temperature within a limited range. Conversely, the chart may be used to ascertain the temperature at which a desired viscosity is attained. 1.2 The chart is suitable for original asphalt cements and for asphalts recovered from laboratory aging tests or extracted from pavements. 1.3 The chart is based on a viscosity temperature relationship that can be plotted using any appropriate set of units. For convenience, charts based on both conventional and SI units are provided. 1.4 The range of the chart is sufficient for roofing asphalts. 1.5 The range of the chart is sufficient for liquid asphalts (bitumens) whose viscosity exceeds 0.01 Pa.S (10 centipoise). 1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 2. Referenced Documents 2.1 ASTM Standards: 2 D341 Practice for Viscosity-Temperature Charts for Liquid Petroleum Products D2170 Test Method for Kinematic Viscosity of Asphalts (Bitumens) D2171 Test Method for Viscosity of Asphalts by Vacuum Capillary Viscometer D3205 Test Method for Viscosity of Asphalt with Cone and Plate Viscometer 3 1 This chart is under the jurisdiction of ASTM Committee D04 on Road and Paving Materials and is the direct responsibility of Subcommittee D04.44 on Rheological Tests. Current edition approved Dec. 1, 2009. Published January 2010. Originally approved in 1966. Last previous edition approved in 2001 as D2493 01 1. DOI: 10.1520/D2493_D2493M-09. 2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard s Document Summary page on the ASTM website. 3 Withdrawn. The last approved version of this historical standard is referenced on www.astm.org. D4402 Test Method for Viscosity Determination of Asphalt at Elevated Temperatures Using a Rotational Viscometer D4957 Test Method for Apparent Viscosity of Asphalt Emulsion Residues and Non-Newtonian Bitumens by Vacuum Capillary Viscometer 3. Significance and Use 3.1 The viscosity-temperature chart is a convenient means of plotting the viscosity data for estimating the viscosity of asphalts, recovered asphalts, and roofing asphalts at any temperature within a limited range. It is also a convenient means to estimate the temperature at which a desired viscosity is attained. Charts may be constructed manually or using computer graphing software. 3.2 Kinematic viscosity-temperature charts are described in Charts D341. 4. Description 4.1 For Fig. 1, the chart coordinates are logarithm of the logarithm of the viscosity in mpa.s as the ordinate, and logarithm of the absolute temperature in degrees Kelvin (degrees C + 273.2) as the abscissa. However, the viscosity in Pa.S and the temperature in degrees Celsius is shown in the chart for convenience. ~1 Pa.s 5 mpa.s 3 10 3! (1) 4.2 For Fig. 2, the chart coordinates are logarithm of the logarithm of the viscosity in centipoise as the ordinate, and logarithm of the absolute temperature in degrees Rankine (degrees F + 459.7) as the abscissa. However, viscosity in poise, and the temperature in degrees Fahrenheit is shown in the chart for convenience. 4.3 The temperature range of the charts may be extended or abbreviated as necessary. 5. Procedure 5.1 If the viscosities are not known they should be determined in accordance with Test Methods D2170, D2171, D3205, D4402, or D4957. Viscosities determined at temperatures other than the temperatures specified in each of these test methods may be used. 5.2 For temperatures above 60 C [140 F], plot two viscosity-temperature points and carefully draw a straight line through the points. Plot at least three viscosity-temperature Copyright ASTM International, 100 Barr Harbor Drive, PO Box C-700 West Conshohocken, Pennsylvania 19428-2959, United States 1

FIG. 1 Viscosity-Temperature Chart for Asphalts on Which a Typical Experimental Curve Has Been Plotted points if the included temperature range is below 60 C [140 F]. Carefully draw a straight line or curve through the points. A point on this line, within the temperature range of the points plotted, shows the viscosity at the corresponding desired temperature. NOTE 1 These charts are appropriate for use at higher temperatures, where asphalts are primarily viscous. At lower temperatures most asphalts become viscoelastic. When this occurs, viscosity alone is insufficient to describe an asphalt s flow properties. Most asphalts are primarily viscous at temperatures above 60 C [140 F]. Caution should be used when applying this standard below that temperature. NOTE 2 Some asphalts have viscosity-temperature relationships too complex to be represented by only three points, as shown in Fig. 1. In this case determine the viscosity at sufficient temperatures to produce a curve adequate for the purpose intended. NOTE 3 Viscosities determined by extrapolation of data may be unreliable 5.3 The viscosity values represented by the data points may have been obtained at different shear rates. This chart does not reflect the shear rate at which the viscosities were determined. 6. Keywords 6.1 asphalt; rheology; viscosity; viscosity-temperature chart 2

FIG. 2 Viscosity-Temperature Chart for Asphalts on Which a Typical Experimental Curve Has Been Plotted APPENDIX (Nonmandatory Information) X1. SUGGESTIONS FOR DATA ANALYSIS X1.1 The chart in Fig. 1 includes the region where the viscosity of asphalts depends not only on the temperature, but also on the shearing conditions. Therefore, the data plotted on the viscosity-temperature chart must be obtained under standardized shearing conditions, for example, at the same shear rate, or the same shear stress. Constant shearing conditions also implies the use of the same viscometer, or viscometers of the same type and size, to avoid differences in viscosity values caused by differences in the extent of breakdown of the micellar structure of the asphalt due to shearing in the measurement process. X1.2 Asphalt viscosities are often reported at an arbitrary shear rate of 0.05 s 1. Interpolation or extrapolation of measured viscosity data is often required to obtain values for this shear rate. A useful model for interpolating or extrapolating asphalt rheological measurements is the empirical Power Law relationship: t5h 1 ġ c (X1.1) where: t = the shearing stress, ġ = the rate of shear, h 1 = the apparent viscosity at a shear rate of 1 s 1, and c = the slope of a plot of log t versus log ġ. The parameter c is called the Complex Flow Index, and is an indicator of the rheological character of the material. For Newtonian liquids, whose viscosity does not vary with shear 3

rate, c = 1. If c < 1, the apparent viscosity decreases with increasing shear rate, and if c > 1, the apparent viscosity increases with shear rate. X1.3 Because a small error in the value of c can cause a large error in an extrapolated viscosity value, it is recommended that the Power Law slope be determined using replicate tests on the material. The average value of c can be determined by regression analysis of the log t versus log ġ data. If the data for replicate tests do not superimpose on a plot of all the data on the same chart, the calibration and operating procedure for the viscometer should be checked before proceeding further with the data analysis. If there are a small number of outliers, these can be discarded, and the remainder of the data used in the regression analysis. Fig. X1.1 shows an example of data containing outliers that should be ignored. X1.3.1 The objective of screening for outliers should be to retain all data that legitimately belong in the population of results characteristic of the test method used, and to eliminate only those that differ so drastically that their inclusion distorts the shear stress versus shear rate relationship. Therefore, the criterion for rejecting data should be conservative. If a statistical technique is used, the significance level of the test should be no greater than one percent. X1.4 Large extrapolations of rheological data to obtain values at constant shear rate are often unavoidable because most viscometers allow a limited range of shear stress, and the large variation in viscosity over a range of temperatures results in large differences in observed shear rate at different test temperatures. A procedure which circumvents this problem is to plot the apparent viscosity at constant power input per unit volume as a function of temperature. This avoids long extrapolations of the shear stress/shear rate relationships. H. E. Schweyer and others have recommended that apparent viscosities at a constant power input of 100 W/m 3 be used. However, this value has no theoretical significance, and may not be appropriate for all viscometers. A value which minimizes the amount of extrapolation needed to estimate the apparent viscosities in the temperature range of interest should be selected. or more temperatures on the chart in Fig. 1. Because of the non-linearity of the scales on this chart, the viscosities must be plotted in the units shown. Many asphalts will have a straight line viscosity versus temperature relationship on the chart. However, a minimum of 3 points should be plotted, to ensure that the nature of the relationship is shown. Because of the possibility of curvature, particularly at very high viscosity levels, extrapolation is not recommended. X1.7 Alternatively, a regression analysis of log log h versus log T (absolute temperature) can be performed. To be consistent with Fig. 1, the viscosity values must be converted to mpa.s or cp before taking the logarithms. A straight regression line of this type is shown in Fig. X1.2. FIG. X1.1 Power Law Shear Stress versus Shear Rate Relationship X1.5 To estimate the apparent viscosity at constant power input, first determine the Power Law constants h 1 and c from a plot or regression analysis of log shear stress versus log shear rate. Calculate the apparent viscosity at power input P from: h P 5h 1F P h 1 G c 2 1 c 1 1 where: h P = apparent viscosity, Pa.s at power input P, W/m 3, h 1 = apparent viscosity, Pa.s at 1 s 1 shear rate, and c = complex flow index. (X1.2) X1.6 The effect of temperature on apparent viscosity can be shown by plotting the constant power input viscosities at two FIG. X1.2 Viscosity versus Temperature Relationship 4

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/ COPYRIGHT/). 5