DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M M18

Similar documents
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

How To Read A Pipe From A Sensor

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

CQM1-SF200/CS1W-SF200

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Capacitive Prox E2K-X

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Proximity Sensor with All-stainless Housing

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Cross-beam scanning system to detect slim objects. 100 mm in

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Tina 2A/B Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit

E2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors

pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1

Liquid Leakage Sensor Amplifier

Absolute Rotary Encoder E6CP

Smile 11 AS-i Emergency stop with safe AS-i input node

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Ordering Information. Specifications. Electrode Holder Electrode Holders. Accessories (Order Separately)

Incremental Rotary Encoder E6B2

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Color Mark Sensor with Red or Green LED E3S-VS

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Safety Manual BT50(T) Safety relay / Expansion relay

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

CMOS Laser Sensor with Built-in Amplifier

Cylindrical Proximity Sensor

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Inductive sensor NI10-M18-Y1X-H1141

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Cylindrical Proximity Sensor

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

U-shaped Micro Photoelectric Sensor

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Adjustment functions for both span and shift have been incorporated

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Solid-State Timer H3G

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Surface Mounting Relay

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Universal Voltage Terminal Photoelectric E3JM

Inductive Proximity Sensors

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SPST-NO SPDT DPST-NO DPDT

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Type Supply voltage Output Connection Sensing range Standard target Timer function Part number Polarized VDC NPN/PNP Pre-leaded 500 mm to 10 m

Phase-sequence Phase-loss Relay

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Conductive Level Controller

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Preset Counter signo 721

RY2 miniature industrial relays

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

General-purpose Relays

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Manual. Solar Fountain Mobile Phone Charger

Knob Potentiometer with Switch

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

Solid State Relays for Heaters

38 Series - Relay interface modules A

Transparent Object Detection Photoelectric Sensor

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Transcription:

Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Capacitive Sensor Product lineup with M1, M1, and M models. Fixed sensing distance requires no sensitivity adjustment. Be sure to read Safety Precautions on page. Ordering Information Sensors [Refer to Dimensions on page.] Appearance Sensing distance Output configuration Operation mode DC -wire, NPN EK-ME1 M EK-ME M M1 mm DC -wire, PNP EK-MF1 M EK-MF M AC -wire EK-MY1 M EK-MY M Unshielded DC -wire, NPN EK-ME1 M EK-ME M M1 mm DC -wire, PNP EK-MF1 M EK-MF M AC -wire EK-MY1 M EK-MY M DC -wire, NPN EK-1ME1 M EK-1ME M M 1 mm DC -wire, PNP EK-1MF1 M EK-1MF M AC -wire EK-1MY1 M EK-1MY M Accessories (Order Separately) Mounting Brackets Refer to Y9@ for details. 1

Ratings and Specifications EK- Item EK-ME@, EK-MF@, EK-MY@ EK-ME@, EK-MF@, EK-MY@ Sensing distance mm ±1% mm ±1% 1 mm ±1% Set distance *1 to. mm to. mm to 1 mm Differential travel Detectable object Standard sensing object Response frequency Power supply voltage* (operating voltage range) Current consumption % to % of sensing distance Conductors and dielectrics plate: 1 mm E and F s: 1 Hz, Y s: 1 Hz E and F s: 1 to VDC (1 to VDC) Y s: 1 to VAC (9 to VAC) E and F s: 1 ma max. *1. The above values are sensing distances for the standard sensing object. Refer to Engineering Data on page for other materials. *. E and F s (DC switching models): A full-wave rectification power supply of VDC ±% (average value) can be used. EK-1ME@, EK-1MF@, EK-1MY@ Leakage current Y s:. ma max. (Refer to page.) current E and F s: ma max.*, Y s: 1 to ma Control output E and F s: 1 V max. ( current: ma, Cable length: m), Y s: Refer to Engineering Data on Residual voltage page. Indicators E and F s: Detection indicator (red), Y s: Operation indicator (red) Operation mode (with sensing object approaching) Protection circuits Ambient temperature range Ambient humidity range Temperature influence E1, F1, and Y1 s: E, F, and Y s: Refer to the timing charts under I/O Circuit Diagrams on page for details. E and F s: Reverse polarity protection, Surge suppressor, Y s: Surge suppressor Operating/Storage: to 7 C (with no icing or condensation) Operating/Storage: 1 to C (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) ±% max. of sensing distance at C in the operating temperature range Voltage influence E and F s: ±% max. of sensing distance at rated voltage at rated voltage ±% Y s: ±% max. of sensing distance at rated voltage at rated voltage ±1% Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength E and F s: 1, VAC, / Hz for 1 min between current-carrying parts and case Y s:, VAC, / Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 1 to Hz, 1.-mm double amplitude for hours each in, Y, and Z directions Shock resistance Destruction: m/s times each in, Y, and Z directions Degree of protection IP (IEC), in-house standards: oil-resistant Connection method Pre-wired s (Standard cable length: m) Weight (packed state) Approx. g Approx. 1 g Approx. g Case Materials Heat-resistant ABS Sensing surface Clamping nuts Polyacetal Accessories Instruction manual

Engineering Data (Reference Value) EK- Sensing Area (Grounded Metal Plate) EK-M 1 1 1 1 1 Y EK-1M Standard sensing object Grounded metal plate 1 mm EK-M EK-M 1 1 EK-M Sensing 1 EK-M Sensing Head EK-1M Sensing Head 1 Distance Y (mm) Influence of Sensing Object Size and Material EK-M EK-M EK-1M 1 d d 1 t = mm 7 Side length of sensing object: d (mm) Sensing Object Thickness and Material vs. Sensing Distance 1 EK-M EK-M EK-1M d d 1 t = mm 7 Side length of sensing object: d (mm) 1 1 d d 1 t = mm 7 Side length of sensing object: d (mm) 1 t 1 t 1 1 t 1 1 Thickness of sensing object: t (mm) 1 1 Thickness of sensing object: t (mm) 1 1 Thickness of sensing object: t (mm)

EK- Leakage Current Residual Output Voltage EK-@MY EK-@MY@ at 1 VAC EK-@MY@ at VAC Leakage current (ma). 1. 1. () ma Protective resistance V AC power, /Hz voltage VL (V) 1 1 Residual output voltage V VL A 1 VAC voltage VL (V) 1 1 Residual output voltage A V VL VAC 1 Power supply voltage (V) Residual Voltage 1 1 current (ma) Residual Voltage 1 1 current (ma) I/O Circuit Diagrams DC -Wire s (NPN) Operation Timing chart Output circuit mode EK-ME1 EK-ME1 EK-1ME1 EK-ME EK-ME EK-1ME Sensing object (between brown Output voltage (between High black and blue leads) Low Detection indicator (red) Sensing object (between brown Output voltage (between black and blue leads) Detection indicator (red) High Low Proximity Sensor main circuit 1 Ω.7 kω. Ω Brown Black *1 Output * Blue *1. current: ma max. *. When a transistor is connected. Tr +V V DC -Wire s (PNP) Operation Timing chart Output circuit mode EK-MF1 EK-MF1 EK-1MF1 EK-MF EK-MF EK-1MF Sensing object (between blue Output voltage (between black and brown leads) Detection indicator (red) High Low High Low AC -Wire s Operation Timing chart Output circuit mode EK-MY1 EK-MY1 EK-1MY1 EK-MY EK-MY EK-1MY Sensing object (between blue Output voltage (between black and brown leads) Detection indicator (red) Sensing object Operation indicator (red) Sensing object Operation indicator (red) Proximity Sensor main circuit.9 kω 7 kω. Ω Brown * Black *1 Blue *1. current: ma max. *. When a transistor is connected. Proximity Sensor main circuit Brown Blue +V V

Safety Precautions EK- Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Ambient Environment The Sensor may malfunction if subjected to water, oil, chemicals, or condensation by falsely detecting these as sensing objects. The EK-1M is highly sensitive to inductive objects and can thus be affected even by small quantities of water drops. Influence of Surrounding Objects If the Sensor is embedded in metal, maintain at least the following distances between the Sensor and the metal. The Sensor is also affected by other materials, such as resins. Separate the Sensor from other materials by the same distance as for metal. l Sensing Objects The maximum sensing distance will decrease if the sensing object is a non-grounded metal object or dielectric object. Sensing Object Material The EK- can detect almost any type of object. The sensing distance of the EK-, however, will vary with the electrical characteristics of the object, such as the conductance and inductance of the object, and the water content and capacity of the object. The maximum sensing distance of the EK- will be obtained if the object is made of grounded metal. There are objects that cannot be detected indirectly. Therefore, be sure to test the EK- in a trial operation with the objects before using the EK- in actual applications. Effects of a High-frequency Electromagnetic Field The EK- may malfunction if there is an ultrasonic washer, highfrequency generator, transceiver, or inverter nearby. For major measures, refer to Noise of Warranty and Limitations of Liability for Photoelectric Sensors. Mounting Do not tighten the nut with excessive force. Always use washers when tightening the nuts and do not exceed the torque in the following table. d dia. n m * Be sure to ground. Metal object * Be sure to ground the metal object, otherwise Sensor operation will not be stable. Influence of Surrounding Metal (Unit: mm) Dimension l d m n EK-M EK-M 1 EK-1M 1 If a mounting bracket is used, be sure that at least the following distances are maintained. Influence of Surrounding Metal (Unit: mm) G Dimension G H EK-M EK-M EK-1M 1 H EK-M EK-M EK-1M Torque.7 N m N m Miscellaneous Organic Solvents The Sensor has a case made of heat-resistant ABS resin. Be sure that the case is free from organic solvents or solutions containing organic solvents. Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. A B Mutual Interference (Unit: mm) Dimension A B EK-M 7 EK-M 1 11 EK-1M

Dimensions EK-ME@ EK-MF@ EK-MY@ EK- (Unit: mm) Tolerance class IT1 applies to dimensions in this data sheet unless otherwise specified. EK-ME@ EK-MF@ EK-MY@ 1 dia. 17 1.7 dia. Indicator * M1 1 Two clamping nuts Two washers *1. E and F s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1. mm), Standard length: m Y s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1. mm), Standard length: m *. E and F s: Detection indicator (red) Y s: Operation indicator (red) *1 9 dia. 1. dia. M1 1 Two clamping nuts Two washers *1. E and F s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1.9 mm), Standard length: m Y s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1.9 mm), Standard length: m *. E and F s: Detection indicator (red) Y s: Operation indicator (red) Indicator * *1 EK-1ME@ EK-1MF@ EK-1MY@ Mounting Hole Dimensions F (mm) EK-M@@ +. 1. dia. dia. 1 Indicator * F EK-M@@ +. 1. dia. EK-1M@@ +.. dia..1 dia. *1 M 1. Two clamping nuts Two washers *1. E and F s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1.9 mm), Standard length: m Y s: -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter: 1.9 mm), Standard length: m *. E and F s: Detection indicator (red) Y s: Operation indicator (red)

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMR's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMR. OMR MAKES WARRANTY OR REPRESENTATI, EPRESS OR IMPLIED, REGARDING N-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKWLEDGES THAT THE BUYER OR USER ALE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMR DISCLAIMS ALL OTHER WARRANTIES, EPRESS OR IMPLIED. LIMITATIS OF LIABILITY OMR SHALL T BE RESPSIBLE FOR SPECIAL, INDIRECT, OR CSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED CTRACT, WARRANTY, NEGLIGEE, OR STRICT LIABILITY. In no event shall the responsibility of OMR for any act exceed the individual price of the product on which liability is asserted. IN EVENT SHALL OMR BE RESPSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMR'S ANALYSIS CFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND T SUBJECT TO CTAMINATI, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATI OR REPAIR. Application Considerations SUITABILITY FOR USE OMR shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMR will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATI INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMR PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMR shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMR representative at any time to confirm actual specifications of purchased products. DIMENSIS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMAE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMR s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMR Warranty and Limitations of Liability. ERRORS AND OMISSIS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMR Corporation Industrial Automation Company http://www.ia.omron.com/ 1.1 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMR Corporation 1 All Right Reserved.